TABLE 3.3-1 (Continued)

REACTOR TRIP SYSTEM INSTRUMENTATION FUNCTIONAL UNIT TOTAL NO.

OF CHANNELS MINIMUM CHANNELS CHANNELS TO TRIP OPERABLE ALLOWABLE VALUE APPLICABLE MODES

21.

Reactor Trip Breakers

22.

Automatic Trip Logic

23.

Reactor Trip System Interlocks A. Intermediate Range Neutron Flux, P-6 B.

Power Range Neutron Flux, P-8 C.

Power Range Neutron Flux, P-9 D. Power Range Neutron Flux, P-10 E. Turbine First Stage Pressure, P-13 2

2 2

1 1

1 2

1 2

4 4

4 2

1 2

2 2

1 2

2 2

2 1

3 3

3 1

Not Applicable Not Applicable Not Applicable Not Applicable

Ž 9.0 x 10-11 Amps

30.5% RATED THERMAL POWER
  • 49.5% RATED THERMAL POWER

Ž 9.5% RATED THERMAL POWER on increasing power and

  • 10.5% RATED THERMAL POWER on decreasing power
  • 10.5% of RTP Turbine First Stage Pressure Equivalent 1, 2 3(3),

4(3),

5(3) 1, 2 3(3),

4(3) 5(3) 2 1

1 1

BEAVER VALLEY -

UNIT 1 3/4 3-4a Amendment No..23T 252 ACTION 40 39 1

39 3

12 12 12 12

-4 1'

CONTAINMENT SYSTEMS SURVEILLANCE REQUIREMENTS (Continued)

c.

At least once per 18 months during shutdown, by:

1.

Cycling each power operated (excluding automatic) valve in the flow path that is not testable during plant operation, through at least one complete cycle of full travel.

2.

Verifying that each automatic valve in the flow path actuates to its correct position on a test signal.

3.

Verifying that each spray pump starts automatically on a test signal.

d.

Following maintenance which results in the potential for nozzle blockage, as determined by engineering evaluation, by verifying each spray nozzle is unobstructed.

BEAVER VALLEY - UNIT 1 Amendment No. _.3-252 3/4 6-12

CONTAINMENT SYSTEMS SURVEILLANCE REQUIREMENTS (Continued)

d.

Verify, at the frequency specified in the Inservice Testing

Program, that each recirculation spray pump's developed head at the flow test point is greater than or equal to the required developed head as specified in the Inservice Testing Program and the Containment Integrity Safety Analysis.
e.

At least once per 18 months during shutdown, by:

1. Cycling each power operated (excluding automatic) valve in the flow path not testable during plant operation, through at least one complete cycle of full travel.
2.

Verifying that each automatic valve in the flow path actuates to its correct position on a test signal.

f.

Following maintenance which results in the potential for nozzle blockage, as determined by engineering evaluation, by verifying each spray nozzle is unobstructed.

BEAVER VALLEY -

UNIT 1 Amendment No

"",252 3/4 6-14