February 25, 2003 LICENSEE:

Tennessee Valley Authority FACILITY:

Sequoyah Nuclear Plant, Unit 1

SUBJECT:

SUMMARY

OF FEBRUARY 12, 2003, MEETING WITH TENNESSEE VALLEY AUTHORITY (TVA) TO DISCUSS THE SEQUOYAH, UNIT 1, STEAM GENERATOR COMPARTMENT ROOF MODIFICATIONS (TAC NO. MB5387)

On February 12, 2003, the U.S. Nuclear Regulatory Commission (NRC) staff met with representatives of TVA and Bechtel at the NRC Headquarters in Rockville, Maryland. TVA requested this meeting to discuss an alternative to the through-bolted splice-plated methodology proposed in Bechtels Topical Report No. 24370-TR-C-003. The licensee discussed the selected alternative for the repair of the steam generator (SG) compartment roof modifications during the replacement of the SG for Sequoyah Nuclear Plant, Unit 1. The alternative proposed uses steel reinforced beams to re-establish the SG compartment roofs.

TVA provided to the staff a draft copy of the revised Bechtels Topical Report dated February 7, 2003, for Sequoyah, Unit 1, SG Replacement Compartment Roof Modification.

The revised report addresses responses to the NRC staff requests for additional information.

The licensee discussed the selected alternative for the repair. The participants discussed the boundary condition analysis, the tensioning of the bolts, and the shim placement. TVA and Bechtel representatives answered the staffs questions. Bechtel will be revising the topical report to address the identified issues. The staff had no additional questions. TVA indicated that the final version of the topical report would be submitted to the NRC by February 14, 2003.

This meeting was classified as a Category 1 meeting, which provided an opportunity for members of the public to communicate with the NRC staff after the business portion, but before the meeting was adjourned. However, there were no members of the public in attendance. is a list of attendees, Attachment 2 is a copy of TVAs handout distributed during the meeting, and Attachment 3 is a copy of the draft Bechtels topical report.

The staff noted that the above meeting was beneficial in gaining an understanding of TVAs plans and activities regarding the pending SG replacement for Sequoyah, Unit 1.

Sincerely,

/RA/

Raj K. Anand, Project Manager, Section 2 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-327 Attachments: As stated cc w/Attachments: See next page

ML030560724 OFFICE PDII-2\\PM PDII-2\\LA PDII-2\\SC NAME RAnand BClayton AHowe DATE 2/19/03 2/19/03 2/23/03

Distribution:

PUBLIC PDII-2 R/F JZwolinski/LMarsh HBerkow AHowe RAnand EBrown BClayton (hard copy)

OGC ACRS MKotzalas (e-mail)

JMa GHarrity BSmith (e-mail)

SCahill, RII

ATTENDANCE LIST NUCLEAR REGULATORY COMMISSION (NRC) MEETING WITH TENNESSEE VALLEY AUTHORITY (TVA) AND BECHTEL AT NRC HEADQUARTERS FEBRUARY 12, 2003 NRC TVA Allen Howe Pedro Salas Raj Anand David Ryder Eva Brown Paul Trudel John Ma Michael Dudek Bechtel J. V. Smith Eugene Thomas Myron Anderson

Tennessee Valley Authority SEQUOYAH NUCLEAR PLANT cc:

Mr. J. A. Scalice Chief Nuclear Officer and Executive Vice President Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, Tennessee 37402-2801 Mr. Karl W. Singer, Senior Vice President Nuclear Operations Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. James E. Maddox, Acting Vice President Engineering & Technical Services Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. Richard T. Purcell Site Vice President Sequoyah Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Soddy Daisy, TN 37379 General Counsel Tennessee Valley Authority ET 11A 400 West Summit Hill Drive Knoxville, TN 37902 Mr. Robert J. Adney, General Manager Nuclear Assurance Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. Mark J. Burzynski, Manager Nuclear Licensing Tennessee Valley Authority 4X Blue Ridge 1101 Market Street Chattanooga, TN 37402-2801 Mr. Pedro Salas, Manager Licensing and Industry Affairs Sequoyah Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Soddy Daisy, TN 37379 Mr. D. L. Koehl, Plant Manager Sequoyah Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Soddy Daisy, TN 37379 Senior Resident Inspector Sequoyah Nuclear Plant U.S. Nuclear Regulatory Commission 2600 Igou Ferry Road Soddy Daisy, TN 37379 Mr. Lawrence E. Nanney, Director Division of Radiological Health Dept. of Environment & Conservation Third Floor, L and C Annex 401 Church Street Nashville, TN 37243-1532 County Executive Hamilton County Courthouse Chattanooga, TN 37402-2801 Ms. Ann P. Harris 341 Swing Loop Road Rockwood, Tennessee 37854