ML030060047
| ML030060047 | |
| Person / Time | |
|---|---|
| Site: | Sequoyah |
| Issue date: | 01/06/2003 |
| From: | Heman R NRC/NRR/DLPM/LPD2 |
| To: | Scalice J Tennessee Valley Authority |
| Hernan R W, NRR/NRC/DLPM,301-415-2010 | |
| References | |
| TAC MB5387 | |
| Download: ML030060047 (4) | |
Text
January 6, 2003 Mr. J. A. Scalice Chief Nuclear Officer and Executive Vice President Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801
SUBJECT:
SEQUOYAH NUCLEAR PLANT UNIT 1 STEAM GENERATOR COMPARTMENT ROOF MODIFICATION TOPICAL REPORT (TAC NO. MB5387)
Dear Mr. Scalice:
On March 28, 2002, the Tennessee Valley Authority (TVA, the licensee) submitted three topical reports to the U.S. Nuclear Regulatory Commission (NRC) for review and approval. The topical reports provide the technical basis for the methodology and associated modifications to be applied during the Sequoyah Nuclear Plant (SQN) Unit 1 steam generator (SG) replacement project. The NRC staff held a public meeting on October 24, 2002, to discuss questions associated with all three topical reports for the SG replacement project. A request for additional information (RAI) was issued on December 4, 2002.
The NRC staff has reviewed your report Topical Report No. 24370-TR-C-003, Steam Generator Compartment Roof Modification, which proposes the use of through-bolted splice-plate connections to reconstruct the SG compartment roofs. Based on the information provided in the submittal and technical discussions with your staff during a public meeting on October 24, 2002 and in a conference call on December 17, 2002, the staff finds that the design approach as currently proposed by TVA, to reconstruct the SG compartment modification roof using through-bolted splice-plate connections, is not acceptable.
The staffs assessment of the technical concerns with Topical Report No. 24370-TR-C-003 will be forwarded by correspondence within 30 days. As discussed with Mr. Pedro Salas on December 18, the NRC has scheduled a public meeting on December 23, 2002, to discuss the technical reasons for the denial of the topical report and proposed alternatives.
If you have any questions, please feel free to call Ms. Eva Brown at (301) 415-2315 or Mr. Allen Howe at (301) 415-2024.
Sincerely,
/RA/
Ronald W. Hernan, Senior Project Manager, Section 2 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-327 cc: See next page
ML030060047 DOCUMENT NAME: C:\\ORPCheckout\\FileNET\\ML030060047.wpd OFFICE PDII-2/PM PDII-2/PM PDII-2/PM PDII-2/LA PDII-2/SC NAME EBrown RAnand RHernan BClayton AHowe DATE 12/ 19 /02 12/ 19/ 02 12/ 19 /02 12/ 19/02 12/ 19/02
Mr. J. A. Scalice SEQUOYAH NUCLEAR PLANT Tennessee Valley Authority cc:
Mr. Karl W. Singer, Senior Vice President Nuclear Operations Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. James E. Maddox, Acting Vice President Engineering & Technical Services Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. Richard T. Purcell Site Vice President Sequoyah Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Soddy Daisy, TN 37379 General Counsel Tennessee Valley Authority ET 11A 400 West Summit Hill Drive Knoxville, TN 37902 Mr. Robert J. Adney, General Manager Nuclear Assurance Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. Mark J. Burzynski, Manager Nuclear Licensing Tennessee Valley Authority 4X Blue Ridge 1101 Market Street Chattanooga, TN 37402-2801 Mr. Pedro Salas, Manager Licensing and Industry Affairs Sequoyah Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Soddy Daisy, TN 37379 Mr. D. L. Koehl, Plant Manager Sequoyah Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Soddy Daisy, TN 37379 Senior Resident Inspector Sequoyah Nuclear Plant U.S. Nuclear Regulatory Commission 2600 Igou Ferry Road Soddy Daisy, TN 37379 Mr. Lawrence E. Nanney, Director Division of Radiological Health Dept. of Environment & Conservation Third Floor, L and C Annex 401 Church Street Nashville, TN 37243-1532 County Executive Hamilton County Courthouse Chattanooga, TN 37402-2801 Ms. Ann P. Harris 341 Swing Loop Road Rockwood, Tennessee 37854