Retake Exam - 07/2002 - Draft Exam Comments, ES-401-9
ML030340540
Person / Time
Site: Waterford 
(NPF-038)
Issue date: 05/23/2002
From: Gody A
Division of Reactor Safety IV
To: Venable J
Entergy Operations
References
50-382/02-302, ES-401-9 50-382/02-302
Download: ML030340540 (3)


Text

WATERFORD - JULY 2002 ES-401 Written Examination Form ES-401-9 (R8, S1)

Review Worksheet Q#

1.

LOK (F/H) 2.

LOD (1-5)

3. Psychometric Flaws
4. Job Content Flaws
5. Other 6.

U/E/S 7.

Explanation Stem Focus Cues T/F Cred.

Dist.

Partial Job-Link Minutia

  1. /

units Back-ward Q=

K/A SRO Only 1

H 3

S

^

2 H

3 S

^

3 H

4 S

4 H

4 S

5 H

4 S

6 F

2 S

7 H

3 S

8 F

2 S

9 H

4 S

10 H

4 S

^

Instructions

[Refer to Section D of ES-401 and Appendix B for additional information regarding each of the following concepts.]

1.

Enter the level of knowledge (LOK) of each question as either (F)undamental or (H)igher cognitive level.

2.

Enter the level of difficulty (LOD) of each question using a 1 - 5 (easy - difficult) rating scale (questions in the 2 - 4 range are acceptable).

3.

Check the appropriate box if a psychometric flaw is identified:

The stem lacks sufficient focus to elicit the correct answer (e.g., unclear intent, more information is needed, or too much needless information).

The stem or distractors contain cues (i.e., clues, specific determiners, phrasing, length, etc).

The answer choices are a collection of unrelated true/false statements.

More than one distractor is not credible.

One or more distractors is (are) partially correct (e.g., if the applicant can make unstated assumptions that are not contradicted by stem).

4.

Check the appropriate box if a job content error is identified:

The question is not linked to the job requirements (i.e., the question has a valid K/A but, as written, is not operational in content).

The question requires the recall of knowledge that is too specific for the closed reference test mode (i.e., it is not required to be known from memory).

The question contains data with an unrealistic level of accuracy or inconsistent units (e.g., panel meter in percent with question in gallons).

The question requires reverse logic or application compared to the job requirements.

5.

Check questions that are sampled for conformance with the approved K/A and those that are designated SRO-only (K/A and license level mismatches are unacceptable).

6.

Based on the reviewers judgment, is the question as written (U)nacceptable (requiring repair or replacement), in need of (E)ditorial enhancement, or (S)atisfactory?

7.

At a minimum, explain any U ratings (e.g., how the Appendix B psychometric attributes are not being met).

ES-401 2

Form ES-401-9 (R8, S1)

Q#

1.

LOK (F/H) 2.

LOD (1-5)

3. Psychometric Flaws
4. Job Content Flaws
5. Other 6.

U/E/S 7.

Explanation Stem Focus Cues T/F Cred.

Dist.

Partial Job-Link Minutia

  1. /

units Back-ward Q=

K/A SRO Only 11 H

3 S

12 F

3 S

13 F

3 S

^

14 F

3 S

^

15 H

4 S

^

16 F

3 S

17 H

3 E

Answer given in key is not one of choices 18 F

2 S

19 H

3 S

20 H

3 S

21 H

3 S

22 H

3 S

23 H

3 S

24 H

3 S

25 H

3 S

26 H

3 S

^

27 H

3 S

^

28 H

3 S

^

29 H

3 S

30 H

3 S

^

31 H

3 S

^

32 F

3 S

^

33 H

3 S

34 H

3 S

Q#

1.

LOK (F/H) 2.

LOD (1-5)

3. Psychometric Flaws
4. Job Content Flaws
5. Other 6.

U/E/S 7.

Explanation Stem Focus Cues T/F Cred.

Dist.

Partial Job-Link Minutia

  1. /

units Back-ward Q=

K/A SRO Only 35 H

3 S

36 H

2 S

37 F

3 S

38 F

3 S

39 H

3 E

Reference provided does not support answer 40 H

3 S

41 F

2 S

42 H

3 S

43 H

4 S

^

44 F

2 S

^

45 F

3 S

^

46 H

3 S

47 H

4 S

48 F

3 S

49 H

4 S

50 H

3 S

51 H

4 U

E Per the reference, answer is true only if SGFPs are being supplied with reheat steam 52 F

3 S

53 H

3 S

54 H

3 S

55 F

3 S

56 F

3 S

^

57 H

3 S

^

58 H

2 S

^

59 H

3 S

60 H

3 S

^

Q#

1.

LOK (F/H) 2.

LOD (1-5)

3. Psychometric Flaws
4. Job Content Flaws
5. Other 6.

U/E/S 7.

Explanation Stem Focus Cues T/F Cred.

Dist.

Partial Job-Link Minutia

  1. /

units Back-ward Q=

K/A SRO Only 61 F

3 E

^NUREG-1021, Appendix B, Item C.2.e states that negatively worded stems should be avoided. Provide justification or rewrite.

62 F

3 S

63 F

3 S

64 H

3 S

65 H

3 S

66 H

3 S

67 H

2 U

U E

Stem should also solicit Tavg response. Use similar terminology in Distractors B and D.

68 F

1 U

U There are no credible distractors 69 F

3 E

^KA different than outline, but it is proper group and tier. Appropriately document change.

70 H

3 S

71 H

3 S

72 H

3 S

^

73 F

2 S

^

74 H

3 S

^

75 H

4 S

76 F

3 S

77 H

3 U

U E

Distractor C appears implausible in that auto close does not seem consistent with placing key switch in close position 78 F

3 U

E Reword last statement in stem similar to which of the following statements is valid concerning starting these pumps 79 H

3 E

References do not indicate that Door 170 must be verified operable by testing CVAS system as indicated in answer 80 F

3 S

81 H

3 S

82 H

3 S

83 F

3 S

Q#

1.

LOK (F/H) 2.

LOD (1-5)

3. Psychometric Flaws
4. Job Content Flaws
5. Other 6.

U/E/S 7.

Explanation Stem Focus Cues T/F Cred.

Dist.

Partial Job-Link Minutia

  1. /

units Back-ward Q=

K/A SRO Only 84 F

3 S

85 H

3 S

^

86 F

3 S

^

87 F

2 S

^

88 F

2 E

Reference provided does not justify answer 89 H

3 U

S Only valid if TS 3.0.3 is not provided 90 F

2 S

91 F

3 S

92 F

2 U

U Distractors C and D are invalid because plant is already in hot standby 93 F

2 S

94 F

3 E

KA changed from 2.3.1 to 2.3.10. Justify and document.

95 F

3 U

E Specify entry made by HP technician or personnel accompanied by HP technician 96 H

3 S

97 H

3 S

98 F

2 S

^

99 F

3 S

^

100 F

3 S

^

Part of 30 question sample NOTES:

1.

Reviewer rated average question difficulty at 2.94 with level of knowledge at the fundamental level for 40 questions.

2.

Because author provided very few solutions, some answers were accepted on faith. Reviewer did not solve every problem.