ML030150160

From kanterella
Jump to navigation Jump to search
Revision to EP-PS-130-9, Met/Vent Acquisition Options
ML030150160
Person / Time
Site: Susquehanna  
(NPF-014, NPF-022)
Issue date: 01/09/2003
From:
Susquehanna
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML030150160 (9)


Text

Jan.

09, 2003 SPage 1

of 1 MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2003-1 4

USER INFORMATION:

EMPL#:23244 CA#:

0363 TRANSMITTAL INFORMATION:

01/09/2003 LOCATION:

DOCUMENT CONTROL DESK PROM:

NUCLEAR RECORDS DOCUMENT CONTROL CENTER NUCSA-2)

K-P.HE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU:

130 130 -

HP II DOSE CALCULATOR:

EMERGENCY PLAN POSITION SPECIFIC PROCEDURE REMOVE MANUAL TABLE OF CONTENTS DATE:

09/25/2002 ADD MANUAL TABLE OF CONTENTS DATE:

01/08/2003 CATEGORY:

PROCEDURES TYPE:

EP ID:

EP-PS-130 REPLACE:

REV:14 REPLACE:

REV:14 REMOVE:

PCAF 2002-1478 REV:

N/A UPDATES FOR HARD COPY MANUALS WILL BE DISTRIBUTED WITHIN 5 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES.

PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON RECEIPT OF HARD COPY.

FOR ELECTRONIC MANUAL USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX.

Tab T ab ý9 EP-PS-1 30-9 METNENT DATA ACQUISITION OPTIONS The following are sources of meteorological and ventilation data at Susquehanna SES:

A. ACQUISITION OF METNENT DATA FROM THE PICSY TERMINAL

1. From the SSES LOGO display, select E-PLAN MENU or type EPM and

[ENTER].

2. All required meteorological and ventilation (METNENT) inputs for the MIDAS dose projections can be obtained by selecting the METNENT DATA display option on the E-PLAN menu.
a. Veht and Primary Met Tower Data is displayed on page 1 of this display.
b. Use the PAGE FORWARD command if the Back-up Tower data is required.
c. Should neither the Primary or Back-up Tower be available, obtain the Downriver Tower data as follows:
1)

Click on the E-PLAN MENU button at the top right hand corner of the METNENT DATA screen.

2)

On the E-Plan menu select and click on the MET DATA screen.

3)

Obtain the Downriver Tower wind speed (Point ID VMS05B), wind direction (Point ID VMX09B), and sigma theta (PointJlD VMX10B).

4)

Return to the E-Plan menu by clicking on the E-PLAN MENU button at the bottom right hand corner of the MET DATA screen.

d. Other options - see Step 6 below.
3. If the Primary Met Tower AT data is not available, determine the wind speed corrected stability class as follows:
a. Determine the initial (uncorrected) stability class using the measured value of sigma theta and the Supplemental Meteorological Information Table 1 (or page 2 of the PICSY screen).
b. Determine the wind speed corrected stability classification using the initial classification, the measured wind speed, and, as appropriate, either Table 2 or Table 3.

EP-AD-000-124, Revision 20, Page 1 of 8

Tab 9 EP-PS-1 30-9

4. The PICSY QUALITY CODES for the display colors are as follows:

YELLOW:

DATA ACCEPTABLE RED:

DATA EXCEEDS WARNING LIMIT MAGENTA:

DATA EXCEEDS ALARM SETPOINT WHITE:

DATA SUSPECT

5. If a hard copy printout of the information is required you may either:
a. Select the PRINT option using the pull down menu (screen copy takes approximately 3 minutes to complete); or
b. Initiate the METNENT DATA LOG option as follows:
1) -

On the E-PLAN menu, select the FREE FORMAT LOG MENU.

2)

To activate the TSC log, press [F1], [22], and [ENTER].

To activate the EOF log, press [F1], [9], and [ENTER].

NOTE: Be sure to read the log description because there are 2 logs for the TSC and 2 logs for the EOF.

3)

The log will start printing at the next quarter hour.

4)

To deactivate the TSC log, press [F3], [22], and [ENTER].

To deactivate the EOF log, press [F3], [9], and [ENTER].

6. If historical METNENT information is required, refer to the following instructions:
a. At command line, type: GD AMETVENT1 and [ENTER].
b. Group point display for that display file will come up. Press the [F3] key for history. (See bottom of screen for F key menu.) A dialog box will appear.
c. The work file name to be used is ARCHIVE.D, which is the default for that field.
d. Enter the desired retrieval time. (Enter 15 for the delta time to receive a fifteen-minute period. Click on OK.)
e. Group point display will return with 1 or 2 point values.

EP-AD-000-124, Revision 20, Page 2 of 8

Tab 9 EP-PS-130-9

f. Press the [F4] key if you want to step slowly through the data. Press the [F5]

key-if you want to step quickly through the data. (See bottom of screen for F key menu for more options.)

g. The group point display will return to real time when history is complete. A message at the top of the screen will alert you that it is returning to real time.
6. To exit the menu, select the [ESC] key.

B. Site-specific meteorological information can be obtained by contacting either ABS Consulting or the National Weather Service (NWS).

1. ABS Consulting ABS Consulting is the primary meteorological contractor for the Susquehanna Steam Electric Station (SSES). ABS Consulting has the ability to interrogate the primary and backup meteorological towers on a real-time basis and provide short and long-term weather forecasts for the site and surrounding area.

ABS Consulting provides this emergency service to PPL ONLY during normal working hours. The SSES Project Manager's name, phone number and mailing address are as follows:

ABS Consulting Mark Abrams (301) 907-9100 (301) 907-0050 (Fax)

ABS Consulting Suite 620 East 7315 Wisconsin Avenue Bethesda, MD 20814

2. NATIONAL WEATHER SERVICE The National Weather Service's (NWS) primary meteorological support responsibility for a radiological emergency at SSES resides with the NWS office at Binghamton, New York. In the event the Binghamton office is unable to provide this support, the designated backup is the NWS office in State College, Pennsylvania.

The role of the local NWS office is to provide weather information and forecasts in support of emergency response activities at SSES. The NWS can be EP-AD-000-124, Revision 20, Page 3 of 8

Tab 9 EP-PS-1 30-9 consulted over the telephone if data interpretations, assessment, or forecasting assistance are needed.

This information will include the following:

"* Forecasts at current time and 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> of:

a. 10-meter and 60-meter wind speed and wind direction,
b. Precipitation rate in inches per 15 minutes, and,
c. Boundary layer atmospheric stability described as STABLE, UNSTABLE, or NEUTRAL.

"* Estimates of current 10-meter and 60-meter wind speed and wind direction in the event of complete loss of onsite and offsite meteorological instrumentation.

" General weather forecast from current time to 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> with special emphasis on significant weather occurrences such as major changes in wind speed, wind direction or synoptic weather patterns.

"* Periodic weather updates at time intervals dictated by the on-going weather and emergency situation.

NOTE: The NWS should ONLY be contacted when meteorological support from ABS Consulting is not available (i.e., weekends, holidays, and during the overnight hours).

Whenever contacting the NWS, be sure to provide the following information:

Name, Title, Facility, and Location

  • Reason for the call
  • Status of the Emergency
  • Return telephone number The following telephone numbers are UNLISTED and should only be used for EMERGENCY situations.

EP-AD-000-124, Revision 20, Page 4 of 8

Tab 9 EP-PS-1 30-9 EP-AD-000-124, Revision 20, Page 5 of 8 PRIMARY CONTACT NWS EMERGENCY METEOROLOGICAL SUPPORT OFFICE National Weather Service Office Binghamton Regional Airport 32 Dawes Drive Johnson City, NY 13795 (607) 798-6625 (607) 729-7629 (607) 798-6624 (Fax)

BACKUP CONTACT NWS EMERGENCY METEOROLOGICAL SUPPORT OFFICE National Weather Service Office 227 W. Beaver Avenue, Suite 402 State College, PA 16801 (814) 237-1152 (814) 237-1153 (814) 234-9703 (Fax)

Tab 9 EP-PS-1 30-9 PLANT COMPUTER DATA POINT METEOROLOGICAL IDENTIFIERS METEOROLOGICAL AVERAGING PARAMETER POINT ID*

UNITS PERIOD PRIMARY TOWER - east of the plant, 300' high red/white tower.

10m Wind Direction vma03 degrees 15 minutes 1Dm Wind Speed vma06 mph 15 minutes Delta T "A" vma01

°C/50m 15 minutes Delta T "B" vma02

°C/50m 15 minutes 6Dm Wind Direction vma04 degrees 15 minutes 6Dm Wind Speed vma07 mph 15 minutes 1Dm Sigma "lheta vmalO0 degrees 15 minutes 6Dm Sigma Theta vmx24 degrees 1f5 minutes Precipitation Rate vma09 in/hr 15 minutes Ambient Temperature vmt08b

°F1 hour

/v BACKUP TOWER - across from the SSES Learn inl Center.

1Dm Wind Direction vma05 degrees 15 minutes 1Dm Wind Speed vmaD8 mph 15 minutes 1Dm Si ma Theta vma12 de rees 15 minutes DOWNRIVER TOWER - on Route 93 just east of Nescopeck.

m=

1Dm Wind Direction

  • vmx09b
  • degrees 2 minutes**

10m Wind Speed vms05b mph 2 minutes**

1Dm Sigma Theta vmxlb degrees 12 minutes**

  • Letters are given here in lower case to differentiate the letter o from the number 0.

EP-AD-000-124, Revision 20, Page 6 of 8

Tab 9 EP-PS-1 30-9 SUPPLEMENTARY METEOROLOGICAL INFORMATION TABLES TABLE 1 Stability Class Delta (Alternate)

Plume Width Temperature Sigma Theta

@ 10 miles

% of Hrs at Code Title

(°C/50m)

(degrees)

(miles)

SSES A

Very Unstable

<-.95

>22.5 5.7 6

B Unstable

-.94 to -.85 17.5 to 22.4 4.3 3

C Slightly Unstable

-.84 to -.75 12.5 to 17.4 3.3 4

D Neutral

-.74 to -.25 7.5 to 12.4 2.3 35 E

Slightly Stable

-.24 to.75 3.8 to 7.4 1.6 32 F

Stable

.76 to 2.0 2.1 to 3.7 1.1 12 G

Very Stable

>2.0

<2.1

.75 8

- TABLE 2 DAYTIME (08:00 to 18:00 Initial Stability Class/

FINAL Wind Speed (MPH)

VALUE A

Wind Speed < 7 A

7 < Wind Speed < 9 B

9 <Wind Speed < 13 C

Wind Speed > 13 D

B Wind Speed < 9 B

9 <Wind Speed < 13 C

Wind Speed > 13 D

C Wind Speed < 13 C

Wind Speed > 13 D

D, E, F, G Any wind speed.

D Example: If wind speed is 9 mph and sigma theta is 18 degrees @ 10 a.m., the initial stability class from Table 1 is "B" and the wind speed corrected stability class from Table 2 is "COn.

TABLE 3 NIGHTTIME (18:00 to 08:00 Initial Stability Class/

FINAL Wind Speed (MPH)

VALUE A

Wind Speed < 6 F

6 < Wind Speed < 8 E

Wind Speed > 8 D

B Wind Speed <5 F

5 < Wind Speed < 7 E

Wind Speed _> 7 D

C Wind Speed < 5 E

Wind Speed > 5 D

D Any wind speed.

D E

Wind Speed < 11 E

Wind Speed > 11 D

F,G Wind Speed < 7 F

7< Wind Speed < 11 E

Wind Speed > 11 D

EP-AD-000-124, Revision 20, Page 7 of 8 ATMOSPHERIC STABILITY CLASSIFICATION

Tab 9 EP-PS-130-9 TABLE 4 WIND SECTORS AND DISTANCES Wind From Affected Affected EPB*

On-Site Team Site Boundary

% of Hrs Sector Degrees Sector Sector Distance (mi)

Distance (mi)

Distance Lmii Affected SSES 348-11 N

S 0.34 0.25 0.38 6

12 -33 NNE SSW 0.34 0.37 0.39 9

34-56 NE SW 0.34 0.33 061 12 57-78 ENE WSW 0.34 0.39 1.22 11 79-101 E

W 0.34 0.37 1.03 6

102 - 123 ESE WNW 0.34 0.41 0.61 4

124-146 SE NW 0.34 0.35 0.66 4

147-168 SSE NNW 0.34 0.29 0.59 4

169-191 S

N 0.34 0.29 0.59 5

192-213 SSW NNE 0.34 0.39 0.78 7

214-236 SW NE 0.34 0.42 0.58 11 237 - 258 WSW ENE 0.34 0.52 0.49 7

259-281 W

E 0.34 0.45 0.48 4

282-303 WNW ESE 0.34 0.18 0.50 3

304 - 326 NW SE 0.34 0.20 0.43 3

326 - 348 NNW SSE 0.34 0.20 0.41 5

  • EPB distances established at Exclusion Area Boundary distance of 1800 ft.

EP-AD-000-124, Revision 20, Page 8 of 8 2" *