ML030090122

From kanterella
Jump to navigation Jump to search
License Renewal Safety Evaluation Report for Mcguire, Units 1 and 2, and Catawba, Units 1 and 2
ML030090122
Person / Time
Site: Mcguire, Catawba, McGuire  
(NPF-009, NPF-017, NPF-035, NPF-052)
Issue date: 01/06/2003
From: Kuo P
NRC/NRR/DRIP/RLEP
To: Tuckman M
Duke Energy Corp
Franovich R, NRR/DRIP/RLEP, 415-1868
References
Download: ML030090122 (8)


Text

January 6, 2003 Mr. M. S. Tuckman Executive Vice-President Nuclear Generation Duke Energy Corporation P.O. Box 1006 EC07H Charlotte, NC 28201-1006

SUBJECT:

LICENSE RENEWAL SAFETY EVALUATION REPORT FOR MCGUIRE, UNITS 1 AND 2, AND CATAWBA, UNITS 1 AND 2

Dear Mr. Tuckman:

By a letter dated June 13, 2001, Duke Energy Corporation (Duke) submitted an application to the U.S. Nuclear Regulatory Commission (NRC) for renewal of the McGuire, Units 1 and 2, and Catawba, Units 1 and 2, operating licenses for up to an additional 20 years. The license renewal application (LRA) was submitted pursuant to Title 10 of the Code of Federal Regulations Part 54. The NRC determined that the LRA was complete and acceptable for docketing on August 15, 2001. Since that time, the NRC staff has reviewed the LRA, issued requests for additional information (RAIs), reviewed Dukes responses to the staffs RAIs, developed a safety evaluation report (SER) with open items (issued August 14, 2002), and reviewed Dukes responses to the open items. On the basis of this review, the staff has prepared the enclosed SER to document the findings of the safety review of the LRA and supporting documentation for McGuire, Units 1 and 2, and Catawba, Units 1 and 2.

If you have any questions regarding this matter, please contact the project manager, Rani Franovich, at 301-415-1868.

Sincerely,

/RA/

Pao-Tsin Kuo, Program Director License Renewal and Environmental Impacts Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket Nos.: 50-369, 50-370, 50-413 and 50-414

Enclosure:

As stated cc w/encl: See next page

Mr. M. S. Tuckman Executive Vice-President Nuclear Generation Duke Energy Corporation P.O. Box 1006 EC07H Charlotte, NC 28201-1006

SUBJECT:

LICENSE RENEWAL SAFETY EVALUATION REPORT FOR MCGUIRE, UNITS 1 AND 2, AND CATAWBA, UNITS 1 AND 2

Dear Mr. Tuckman:

By a letter dated June 13, 2001, Duke Energy Corporation (Duke) submitted an application to the U.S. Nuclear Regulatory Commission (NRC) for renewal of the McGuire, Units 1 and 2, and Catawba, Units 1 and 2, operating licenses for up to an additional 20 years. The license renewal application (LRA) was submitted pursuant to Title 10 of the Code of Federal Regulations Part 54. The NRC determined that the LRA was complete and acceptable for docketing on August 15, 2001. Since that time, the NRC staff has reviewed the LRA, issued requests for additional information (RAIs), reviewed Dukes responses to the staffs RAIs, developed a safety evaluation report (SER) with open items (issued August 14, 2002), and reviewed Dukes responses to the open items. On the basis of this review, the staff has prepared the enclosed SER to document the findings of the safety review of the LRA and supporting documentation for McGuire, Units 1 and 2, and Catawba, Units 1 and 2.

If you have any questions regarding this matter, please contact the project manager, Rani Franovich, at 301-415-1868.

Sincerely,

/RA/

Pao-Tsin Kuo, Program Director License Renewal and Environmental Impacts Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket Nos. 50-369, 50-370, 50-413 and 50-414

Enclosure:

As stated cc w/encl. See next page DISTRIBUTION:

See next page Package: ML023640366

1. Letter to M. Tuckman from PTKuo:
2. SER Related to McGuire and Catawba License Renewal Application:

Document Name: C:\\ORPCheckout\\FileNET\\ML030090122.wpd OFFICE PM:RLEP:DRIP Tech Editor BC:SRLB:DSSA BC:SRXS:DSSA NAME RFranovich PKleene JNHannon JSWermiel DATE 01/02/2003 01/02/2003 01/02/2003 01/02/2003 OFFICE BC:IQMB:DIPM BC:EEIB:DE BC:EMEB:DE BC:EMCB:DE NAME TRQuay (DFT for)

JACalvo EVImbro WHBateman DATE 12/31/2002 01/06/2003 01/02/2003 01/06/2003 OFFICE D:DSSA D:DIPM D:DE OGC (NLO)

NAME GMHolahan BABoger RJBarrett SUttal DATE 01/06/2003 12/31/2002 01/06/2003 01/06/2003 OFFICE SC:RLEP:DRIP PD:RLEP:DRIP NAME SSLee PTKuo DATE 01/02/2003 01/06/2003 OFFICIAL RECORD COPY

DISTRIBUTION: Letter to Mr. Michael S. Tuckman, Dated: January 6, 2003 Package: ML023640366 HARD COPY RLEP RF R. Franovich E-MAIL:

PUBLIC J. Johnson W. Borchardt D. Matthews F. Gillespie RidsNrrDe R. Barrett E. Imbro G. Bagchi K. Manoly W. Bateman J. Calvo C. Holden P. Shemanski H. Nieh G. Holahan H. Walker S. Black B. Boger D. Thatcher G. Galletti C. Li J. Moore R. Weisman M. Mayfield A. Murphy W. McDowell S. Smith (Srs3)

T. Kobetz R. Assa C. Munson RLEP Staff R. Martin C. Patel R. Haag C. Julian

McGuire & Catawba Nuclear Stations, Units 1 and 2 cc:

Ms. Lisa F. Vaughn Legal Department (PBO5E)

Duke Energy Corporation 422 South Church St.

Charlotte, NC 28201-1006 County Manager of Mecklenburg County 720 East Fourth St.

Charlotte, NC 28202 Mr. Michael T. Cash Regulatory Compliance Manager Duke Energy Corporation McGuire Nuclear Site 12700 Hagers Ferry Rd.

Huntersville, NC 28078 Anne Cottingham, Esquire Winston and Strawn 1400 L Street, NW Washington, DC 20005 Senior Resident Inspector c/o U. S. Nuclear Regulatory Commission 12700 Hagers Ferry Rd.

Huntersville, NC 28078 Mr. Peter R. Harden, IV VP-Customer Relations and Sales Westinghouse Electric Company 6000 Fairview Rd., 12th Floor Charlotte, NC 28210 Dr. John M. Barry Mecklenburg County Department of Environmental Protection 700 N. Tryon St.

Charlotte, NC 28202 County Manager of York County York County Courthouse York, SC 29745 Mr. Richard M. Fry, Director Division of Radiation Protection North Carolina Department of Environment, Health, and Natural Resources 3825 Barrett Dr.

Raleigh, NC 27609-7721 Ms. Karen E. Long Assistant Attorney General North Carolina Department of Justice P. O. Box 629 Raleigh, NC 27602 Mr. C. Jeffrey Thomas Manager - Nuclear Regulatory Licensing Duke Energy Corporation 526 South Church St.

Charlotte, NC 28201-1006 NCEM REP Program Manager 4713 Mail Service Center Raleigh, NC 27699-4713 Mr. T. Richard Puryear Owners Group (NCEMC)

Duke Energy Corporation 4800 Concord Rd.

York, SC 29745 Mr. Gary Gilbert Regulatory Compliance Manager Duke Energy Corporation 4800 Concord Rd.

York, SC 29745 North Carolina Municipal Power Agency Number 1 1427 Meadowwood Blvd.

P. O. Box 29513 Raleigh, NC 27626-0513 Piedmont Municipal Power Agency 121 Village Dr.

Greer, SC 29651 Saluda River Electric P. O. Box 929 Laurens, SC 29360 North Carolina Electric Membership Corporation P. O. Box 27306 Raleigh, NC 27611 Senior Resident Inspector 4830 Concord Rd.

York, SC 29745 Lou Zeller Blue Ridge Environmental Defense League P.O. Box 88 Glendale Springs, NC 28629 Paul Gunter Nuclear Information &

Resource Service 1424 16th Street NW, Suite 404 Washington, DC 20036 Don Moniak Blue Ridge Environmental Defense League Aiken Office P.O. Box 3487 Aiken, SC 29802-3487 Mr. Kevin Cox The Huntersville Star P. O. Box 2542 Huntersville, NC 28070 Mr. Robert L. Gill, Jr.

Duke Energy Corporation Mail Stop EC-12R P. O. Box 1006 Charlotte, SC 28201-1006 Mr. Henry J. Porter, Assistant Director Division of Waste Management Bureau of Land & Waste Management S.C. Dept of Health and Environ. Control 2600 Bull St.

Columbia, SC 29201-1708 Mr. L. A. Keller Duke Energy Corporation 526 South Church St.

Charlotte, NC 28201-1006 Mr. Gregory D. Robison Duke Energy Corporation Mail Stop EC-12R 526 S. Church St.

Charlotte, NC 28201-1006 Mary Olson Nuclear Information & Resource Service Southeast Office P.O. Box 7586 Asheville, NC 28802 Mr. Alan P. Nelson Nuclear Energy Institute 1776 I Street, N.W., Suite 400 Washington, DC 20006-3708