For Information Only.

CR3 Crystal River Nuclear Facility Summary Report - NCRs Initiated Since 2127102 I

Sorted by Origination Date, Ar Number, Prionty Selection Cnteria: AR Type = NCR and AR Status not = Canceled with Attribute of 1A POTL OPER/REPORT, AR #

Originator AR Subject OrIg. Date AR Status Priority Potential OperlReport NCR Owner 00056666

-HOYT KOON MUV-452 FAILED ITS PMT AFTER PM-20020301 APPROVED 2

N CR3 MAINTENANCE 17 8A.

UNITEVALUATOR GROUP C-AFTER THE PERFORMANCE OF PM-178A ON MUV-452 VIA WR 364990, THE PMT FAILED.

THE'MOVAT OPERATOR SUCCESSFULLY OPENS THE VkLVE, BUT1 DURING THE STROKE TO CLOSE THE VALVE, AT 40% CLO SED, THE TORQUE SWITC9 OPENED.

WE ENGAGED THE OPERATOR MAN UALLY AND FINISHED CLOSING THE VALVE.

AS A RESULT, WE INIT IATED PASSPORT WR 41213 FOR FOLLOWUP REPAIRS.

00056669 RICKY RAWLS GREEN SEA TURTLE RERCUED FROM CR3 20020301 APPROVED I

Y CR3 E&RC RADIATION INTAKE AREA CONTROL UNIT EVAL GRP THE 66TH LIVE SEA TURTLE RESCUED FROM CRYSTAL RIVER SITE, THE MARACULTURE CENTER IDENTIFIED THE TURTLE AS A GREEN SE A TURTLE REQUIRING OFF SITE NOTIFICATION.

00056676 SHAWN SIMON D1 AND DID DAMPER SURVEILLANCE 20020301 INPROG N

CR3 UNITEVAL COMMITMENT QUESTION DURING A PROCEDURE CHANGE )?OR SP-338 IT WAS DISCOVERED THAT A DAMPER CHECK THAT SUPPORTED A COMMITMENT TO GENERIC LETT ER 96-01 MAY HAVE BEEN INADVERTENTLY DELETED.

PT-366 & 367 HAD CONTAINED THE STPES TO INDEPENDENTLY TEST THE CC DAMPE RS D-1 AND DID.

THESE CHECKS WERE TIED TO ITS 3.3.16.

ITS 3.3.16 WAS REMOVED FROM THE TECH SPECS.

THE QUESTION IS WH ETHER OR NOT THE TRUE TIE SHOULD BE CREVS ITS 3.7.18 AND TH E CHECKS ADDED BACK TO SP-353 OR ANOTHER PROCEDURE.

00056680 FAIRMAN BOCKHORST ISR SCREENING NEEDS IMPROVEMENT 20020301 APPROVED 2

N CR3 ASSESSMENT UNIT EVALUATOR GROUP DOCUMENTATION OF THE INDEPENDENT SAFETY REVIEW ENGINEER'S

( ISRE)

SCREENING OF REPORTS THAT EXPAND,

CLARIFY, OR CORRECT PREVIOUSLY SUBMITTED LICENSE AMENDMENT REQUESTS (LAR)

AND THE BASIS FOR DETERMINING IF THE REPORTS REQUIRE A NEW INDE PENDENT REVIEW NEEDS IMPROVEMENT.

00056684 PETER WHITE CONTAMINATION FOUND IN A CLEAN AREA 20020301 COMPLETE 2

N CR3 E&RCRAD PRO UNITEVAL GRP WHILE DOING AN IN DEPTH SURVEY OF THE HP SERVICE ROOM, AN A IR SAMPLE HEAD WAS FOUND CONTAMINATED.

SURVEY NUMBER 02-03 -08.'

THE AIR SAMPLE HEAD WAS DECONED TO <1000 DPM/100CM2.

Run Date/Time:

3/6/02 4:08:52 AM Page 9 of 16 Report Name: RptATNCRslnitLast7aCR3, Created from SrceTbl_ATNCRslnitLast7a GRP Page 9 of 16