CR3 Crystal River Nuclear Facility F

,,,Summary Report - NCRs Initiated Since 3119102 Sorted by Origination Date, AR Number, and Priority Selection Cnteria: AR Type = NCR and AR Status not = Canceled with Attribute of 1A POTL OPER/REPORT AR#

Originator AR Subject Orig. Date Status Date Priority Potential OperlReport NCR Owner 00057794

'MARTIN WOLF A TURTLE RESCUED FROM THE 20020319 20020319 Y

CR3 UNITEVAL INTAKE.

GRP A HEALTHY TURTLE HAS BEEN RESCUED FROM THE INTAKE BAR RACKS AND TRANSPORTED TO THE MARICULTURE CENTER BY SITE SECURITY.

THE TURTLE IS IN A HOLDING TANK AT THE MARICULTURE CENTE R IAW AI-571.

THE NATURAL RESOURCES UNIT STAFF WILL IDENTI FY THE SPECIES AND EVALUATE NOTIFICATION REQUIREMENTS TO TH E NATIONAL MARINE FISHERIES SERVICE IN THE MORNING.

00057760 JEFFREY ENDSLEY CONTROL BOARD LABELING 20020319 20020319 N

CR3 UNITEVAL DISCREPANCIES GRP THE ACTUAL LABELING FOR MUV-53 AND MUV-257 ON THE MCB DO NO T MATCH MCB DRAWINGS (201-162 SHEET 11 AND 13).

EXAMPLE:

TH E FIRST LINE OF THE ACTUAL ESCUTCHEON PLATE FOR MUV-257 REA DS "MUP RECIRC 3B".

THE DRAWING READS "MUP'S RECIRC".

00057803 MARTIN WOLF EFP-2 ETO REMOVAL DELAYED TO 20020319 20020319 N

CR3 UNITEVAL PREPARE LIFT CHECKLIST THE EQUIPMENT TAGGING ORDER REMOVAL FOR EFP-2 WAS DELAYED F OR 3 HOURS WHILE THE LIFT CHECKLIST WAS PREPARED FOR THIS D ETAILED RESTORATION.

IMMEDIATE CORRECTIVE ACTIONS WERE TO COMPLETE THE CHECKLISST, RESTORE THE SYSTEM AND COMMUNICATE THE LESSON TO THE SSOS. THE CNO'S ARE NOT REQUIRED TO G* NERATE A LIFT CHECKLIST BY THE PROCEDURE OR THE PROGRAM PRI OR TO WORK COMPLETION.

FOR ETO'S THAT AFFECT LCO AND/OR MA INTENANCE RULE TIME, THE PRACTICE SHOULD BE TO COMPLE'TE THE LIFT CHECKLIST PRIOR TO WORK COMPLETION TO AVOID DELAYS.

00057711 WESLEY JOHNSON ES CH3 POWER SUPPLY RIPPLE VOLTAGE 20020319 20020319 N

CR3 UNITEVAL HIGH GRP ES CHANNEL 3 +/-15VDC POWER SUPPLY AC RIPPLE VOLTAGES FOUND OUTSIDE ACCEPTABLE RANGE (19.4MV AND 19.2MV RESPECTIVELY)

DURING PERFORMANCE OF SP-132C STEP 4.1.8. THE ACCEPTABLE RA NGE IS 0 TO 14MV.

00057753 FRANCIS O'NEAL INDICATORS FOUND OUT OF CALIBRATION 20020319 20020319 N

CR3 UNITEVAL IN SP-3491 GRP EF-5-PI WAS FOUND OUT OF CALIBRATION AT 0, 25, 50V INCREASI NG AND AT 0, 25, 50, ADN 75k DECREASING BY MORE THAN 0.5 PS IG.

THE INDICATOR WAS CALIBRATED AND RETURNED TO SERVICE.

EF-60-PI WAS FOUND OUT OF TOLERANCE AT 25t INC AND DEC, AND AT 96.67t BY GREATER THAN 15 PSIG.

THIS GAUGE WOULD NOT CALIBRATE AND WILL BE REPLACED.

00057780 JAMES PRITCHARD LOSS OF CONTROL OF SECURITY BADGE.

20020319 20020319 N

CR3 UNITEVAL SEL#23 GRP INDIVIDUAL #20020 LOSS CONTROL OF HIS SECURITY KEYCARD WHIL E MOVING EQUIPMENT.

SUPERVISOR'S BADGE# 20722.

RECOMMENDED OWNER MAINTENANCE Run Date'irme: