CRYSTAL RIVER NUCLEAR PLANT SUPERINTENDENT SHIFT OPERATIONS' LOG Tuesday, January 1, 2002 Leon Gagne/Max Hime 0700-1500 PLANT STATUS: Mode 1, 100% Power, 2544 MWTH, 888 MWE Primary: 579*F Tave, 2160 psig, 1602 ppmb, PZR 222" Secondary: 4 CWPs, OTSGs: 78/75%, 58*F UHS, 1.3"Hga Vacuum Rx Bldg.: 115'F Ave., -0.3 psig, AHF-1BI1C on SW Cooling

  • IL Time*

Item LAG 0809 Relief LAG 1050 Reportable Turtle LAG 1150 WDGA-1 LAC 1245 ENS Update Description Assumed the duties of the Superintendent Shift Operations. [0630] M. Hime assumes the duties of the Control Room Supervisor. [0630]

Received notification from Mariculture Center Staff (E. Latimer) that the turtle rescued from the intake area last night was a Green Sea Turtle. [0919] A 4 Hour Non-Emergency report has been made to the NRC per 10 CFR 50.72 for the offsite notification that is required (NMFS) related to capture of the latest turtle

(#62) this biennial period. (NRC Event 37902 Updated) [1008] This condition is documented on an NCR hard copy that will be added to the system when the system is returned to service. Notifications have been made to: NRC ENS, NRC Resident (S. Sanchez), PGM (D. Roderick), MSO (L. Clewett), and the Regulatory representative (J. Lind).

The H2/0 2 Monitor was out of service to support sampling of the MUT gas space by Chemistry. The compensatory actions of the ODCM, Section 2.16, were applicable during this time. [1012-1103] Face-to-face notification of valve alignment verification and return-to-service was performed by the Chemistry Technician (R. Vaughan).

Received a return call from ENS stating that the Event # for the latest and future turtle reports has been changed from #37902 to #38602. [1145]

(No Additional Entries This Shift)

SSO

  • Indicates time log entry was Initiated Page 6 FORIDA lpow A Prog-8 on-my ccq-any