AmerGen, M AmerGen Energy Company, LLC www.exeloncorp.com An Exelon/British Energy Company 2o0 Exelon Way Suite 345 Kennett Square, PA 19348 10 CFR 50.46 (a)(3)(i) and (ii)

December 18, 2002 2130-02-20349 U. S. Nuclear Regulatory Commission Attn.: Document Control Desk Washington, DC 20555 Oyster Creek Generating Station Facility License No. DPR-16 Docket No. 50-219

Subject:

10 CFR 50.46 Reporting Requirements

Dear Sir/Madam:

In accordance with 10 CFR 50.46 (a)(3)(i) and (ii), the following is a report of the licensing basis Loss-of-Coolant Accident (LOCA) peak clad temperature (PCT) for Oyster Creek Generating Station (OCGS). Table 1 (attached) provides the licensing basis PCT values and the PCT error accumulations for Oyster Creek.

No ECCS model errors applicable to Oyster Creek have occurred since the last report. The baseline PCT for the new GEl 1 fuel type is being included in this report. The GEl 1 fuel type was introduced during the Fall 2002 outage.

Table 1 provides the baseline PCT, the PCT error accumulations, and the resultant estimated licensing basis PCT for both the GE9 and GEl 1 fuel types. The estimated licensing basis PCT remains at 21830F, based on the GE9 fuel type. The licensing basis PCT remains within the 10 CFR 50.46 acceptance limit of 22000F. The current MAPLHGR limits therefore remain bounding, and no additional action is required.

If you have any questions, please contact Mr. Michael Gallagher at 610-765-5664.

Very truly yours, Michael P. Gallagher Director, Licensing and Regulatory Affairs Mid Atlantic Regional Operating Group Attachment cc: H. J. Miller, Administrator, USNRC Region I R. J. Summers, USNRC Senior Resident Inspector, Oyster Creek P. Tam, USNRC Senior Project Manager, Oyster Creek File No. 02088 "A

)

10 CFR 50.46 Reporting Requirements Attachment December 18,2002 TABLE 1 CURRENT BASELINE PCT (1F) VALUES AND ERROR ACCUMULATION OYSTER CREEK GENERATING STATION GE9 GEl I BASELINE PCT 2190 2150 Prior PCT Error Accumulation

-7 N/A PCT Impact of Errors Since Last Report 0

0 TOTAL

-7 0

NEW ESTIMATED LICENSING 2183 2150 BASIS PCT VALUE v,