ML023440302
| ML023440302 | |
| Person / Time | |
|---|---|
| Site: | Kewaunee |
| Issue date: | 11/25/2002 |
| From: | John Lamb NRC/NRR/DLPM/LPD3 |
| To: | Maloney T Nuclear Management Co |
| References | |
| Download: ML023440302 (3) | |
Text
From:
John Lamb To:
Maloney, Theodore L.
Date:
11/25/2002 1:20:36 PM
Subject:
RE: Kewaunee VANTAGE + RAI Conference Call December 2 - 6
- Ted, Attached are some additional RAI questions that I just received from the Tech Staff. Please pass them to the appropriate personnel.
Thanks.
John Additional Questions
- 1. Has the NRC approved the Westinghouse Best Estimate LBLOCA methodology for analyses of Framatome fuel in any other 2-loop upper plenum injection plant?
A. If so, provide a reference and justify that the reference applies to the Kewaunee reload.
B. If not:
- i. Identify and justify LBLOCA analyses that do apply to the Framatome fuel and justify that the analytical processes properly account for mixed fuel types, or ii. justify that the Westinghouse BE LBLOCA methodology applies to Framatome fuel co-resident with the Westinghouse fuel and the analytical processes properly account for mixed fuel types.
- 2. Discuss how the Kewaunee LBLOCA methodology(ies) account for the mixed fuel types.
- 3. Because it is possible for one fuel type to be PCT-limiting, and another to be oxidation-limiting, provide a commitment to report LOCA analysis results for all fuel types (represented in a significant number of assemblies), per 10 CFR 50.46 (a)(3).
>>> "Maloney, Theodore L." <Theodore.Maloney@nmcco.com> 11/22/02 11:33AM >>>
- John, I will be attending the WOG meetings the first week of December but Jerry will be back then. I will confirm with those involved as to what day and when the conference call could take place that week. I am in all next week and will get that information to you ASAP. As always, feel free to call or e-mail me for any information you may need.
Ted Maloney
Licensing Engineer Kewaunee Nuclear Power Plant Phone - 920-388-8863 Fax - 920-388-8333 Ted.Maloney@nmcco.com
Original Message-----
Sent: Friday, November 22, 2002 7:22 AM To: Maloney, Theodore L.
Subject:
Re: Kewaunee VANTAGE + RAI Conference Call December 2 - 6
- Ted, What is the availabilty the first week in December to have a conference call to discuss the VANTAGE + RAI questions that I sent you?
Thanks.
John
>>> "Maloney, Theodore L." <Theodore.Maloney@nmcco.com> 11/21/02 11:59AM >>>
Hi John, Jerry wanted me to make sure you had my correct email address. Here you go.
Ted Maloney Licensing Engineer Kewaunee Nuclear Power Plant Phone - 920-388-8863 Fax - 920-388-8333 Ted.Maloney@nmcco.com