Summary of 11/14/2002 Meeting with FPL Energy Seabrook, LLC (Fple Seabrook) to Discuss the Root Cause Evaluation for Axial Outside Diameter Indications on Steam Generator Tubes
ML023300435
Person / Time
Site: Seabrook NextEra Energy icon.png
Issue date: 11/26/2002
From: Starkey R
NRC/NRR/DLPM/LPD1
To:
Starkey, D, NRR/DLPM, 415-1122
References
TAC MB5299
Download: ML023300435 (7)


Text

November 26, 2002 LICENSEE:

FPL Energy Seabrook, LLC FACILITY:

Seabrook Station, Unit No. 1

SUBJECT:

SUMMARY

OF NOVEMBER 14, 2002, MEETING WITH FPL ENERGY SEABROOK, LLC (FPLE SEABROOK) TO DISCUSS THE ROOT CAUSE EVALUATION FOR AXIAL OUTSIDE DIAMETER INDICATIONS ON STEAM GENERATOR TUBES AT SEABROOK STATION, UNIT NO. 1 This summary refers to the meeting with FPLE Seabrook which was conducted on November 14, 2002, at the U.S. Nuclear Regulatory Commission (NRC) offices in Rockville, Maryland. The meeting was held at the request of the NRC staff. The purpose of the meeting was to discuss the root cause evaluation for axial outside diameter indications identified on steam generator tubes at Seabrook Station during the May 2002 refueling outage. Find enclosed a list of the meeting attendees (Enclosure 1) and a copy of the meeting handout presented by FPLE Seabrook (Enclosed 2).

The FPLE Seabrook presentation closely followed the material provided in the meeting handout and was consistent with the discussion topics listed in the Meeting Notice (ADAMS Accession No. ML023090002).

/RA/

Robert D. Starkey, Project Manager, Section 2 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-443

Enclosures:

1. List of Meeting Attendees
2. Meeting Handout cc w/encls: See next page

November 26, 2002 LICENSEE:

FPL Energy Seabrook, LLC FACILITY:

Seabrook Station, Unit No. 1

SUBJECT:

SUMMARY

OF NOVEMBER 14, 2002, MEETING WITH FPL ENERGY SEABROOK, LLC (FPLE SEABROOK) TO DISCUSS THE ROOT CAUSE EVALUATION FOR AXIAL OUTSIDE DIAMETER INDICATIONS ON STEAM GENERATOR TUBES AT SEABROOK STATION, UNIT NO. 1 This summary refers to the meeting with FPLE Seabrook which was conducted on November 14, 2002, at the U.S. Nuclear Regulatory Commission (NRC) offices in Rockville, Maryland. The meeting was held at the request of the NRC staff. The purpose of the meeting was to discuss the root cause evaluation for axial outside diameter indications identified on steam generator tubes at Seabrook Station during the May 2002 refueling outage. Find enclosed a list of the meeting attendees (Enclosure 1) and a copy of the meeting handout presented by FPLE Seabrook (Enclosed 2).

The FPLE Seabrook presentation closely followed the material provided in the meeting handout and was consistent with the discussion topics listed in the Meeting Notice (ADAMS Accession No. ML023090002).

/RA/

Robert D. Starkey, Project Manager, Section 2 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-443

Enclosures:

1. List of Meeting Attendees
2. Meeting Handout cc w/encls: See next page DISTRIBUTION:

PUBLIC OGC BMcDermott, RGNI KKarwoski PDI-2 R/F ACRS SRichards MModes JZwolinski/TMarsh JAndersen HNieh, EDO CKhan DStarkey MKotzalas LCox JDavis OPA WBateman LLund MSwitzer MMurphy JTsao ZFu Accession Nos.: Letter:ML023300435,Enclosure 2:ML023260159,Package: ML023300457 OFFICE PDI-2/PM PDI-2/LA PDI-2/SC(A)

NAME DStarkey LCox JAndersen DATE 11-25-02 11/25/02 11/26/02 OFFICIAL RECORD COPY LIST OF MEETING ATTENDANCE Licensee:

FPL Energy Seabrook (FPLE Seabrook)

Plant:

Seabrook Station, Unit No. 1

Subject:

Steam Generator Tube Indications - Evaluation and Root Cause Determination Date:

November 14, 2002 Time: 9:00 a.m. - 11:00 a.m.

Location:

NRC Offices, OWFN, Room 04-B6 Name Title Organization NRC STAFF J. Andersen Section Chief (Acting)

NRR/DLPM/PDI-2 D. Starkey Project Manager NRR/DLPM/PDI-2 W. Bateman Chief, EMCB NRR/DE/EMCB M. Murphy Materials Engineer NRR/DE/EMCB J. Tsao Materials Engineer NRR/DE/EMCB L. Lund Section Chief NRR/DE/EMCB Z. Fu Materials Engineer NRR/DE/EMCB K. Karwoski Sr. Lvl Advisor for Steam Gen.

NRR/DE/EMCB M. Modes Sr. Reactor Engineer NRC/Region I C. Khan Sr. Materials Engineer NRR/DE/EMCB J. Davis Sr. Materials Engineer RES/DET/MEB M. Switzer Materials Engineer RES/DET/MEB FPLE SEABROOK M. Warner Site Vice President FPLE Seabrook J. Peschel Regulatory Programs Manager FPLE Seabrook J. Varga Director - Engineering FPLE Seabrook R. White Mechanical Eng. Manager FPLE Seabrook Name Title Organization FLORIDA POWER &

LIGHT (FPL)

G. Boyers FPL Steam Gen. Prog. Coord.

FPL WESTINGHOUSE L. Lagally Fellow Engineer Westinghouse G. Perini Sr. Engineer Westinghouse DUKE POWER D. Mayer no title given Duke Power EXELON S. Leshnoff Steam Gen. Prog. Manager Exelon PUBLIC R. Ballinger Professor MIT/Altran Corporation T. Esselman President Altran Corporation G. Henry Mgr. Steam Gen. NDE EPRI J. Harris Engineer Dominion Engineering J. Fowler Consultant Northeast Utilities D. Raleigh LIS Client Manager LIS, Scientech

Seabrook Station, Unit No. 1 cc:

Mr. J. A. Stall Senior Vice President, Nuclear and Chief Nuclear Officer Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420 Mr. Peter Brann Assistant Attorney General State House, Station #6 Augusta, ME 04333 Resident Inspector U.S. Nuclear Regulatory Commission Seabrook Nuclear Power Station P.O. Box 1149 Seabrook, NH 03874 Town of Exeter 10 Front Street Exeter, NH 03823 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Office of the Attorney General One Ashburton Place 20th Floor Boston, MA 02108 Board of Selectmen Town of Amesbury Town Hall Amesbury, MA 01913 Mr. Dan McElhinney Federal Emergency Management Agency Region I J.W. McCormack P.O. &

Courthouse Building, Room 401 Boston, MA 02109 Mr. Stephen McGrail, Director ATTN: James Muckerheide Massachusetts Emergency Management Agency 400 Worcester Road Framingham, MA 01702-5399 Philip T. McLaughlin, Attorney General Steven M. Houran, Deputy Attorney General 33 Capitol Street Concord, NH 03301 Mr. Donald Bliss, Director New Hampshire Office of Emergency Management State Office Park South 107 Pleasant Street Concord, NH 03301 Mr. Daniel G. Roy Nuclear Training Manager Seabrook Station FPL Energy Seabrook, LLC P.O. Box 300 Seabrook, NH 03874 Mr. James M. Peschel Regulatory Programs Manager Seabrook Station FPL Energy Seabrook, LLC P.O. Box 300 Seabrook, NH 03874 Mr. Gene F. St. Pierre Station Director Seabrook Station FPL Energy Seabrook, LLC P.O. Box 300 Seabrook, NH 03874 Mr. M. S. Ross, Attorney Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420

Seabrook Station, Unit No. 1 cc:

Mr. Rajiv S. Kundalkar Vice President - Nuclear Engineering Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420