TABLE 3.5-1 TABLE 2 CONTAINMENTS, STRUCTURES, AND COMPONENT SUPPORT Component Commodity Group Constituents:

Component/Commodity Group Structure No 8010S01 Bldg 200: Reactor Containment Building Bellows

2. Penetration sleeves, bellows, and dissimilar metal welds.

Mechanical Penetrations.

Component Commodity Group Constituents:

Component/Commodity Group Structure No 8010S01 Bldg 200: Reactor Containment Building Bellows

3. Penetration sleeves, penetration bellows, and dissimilar metal welds Electrical Penetrations.

Fuel transfer tube.

Mechanical Penetrations.

Component Commodity Group Constituents:

Component/Commodity Group Structure No 8010S01 Bldg 200: Reactor Containment Building Equipment Hatch

4. Personnel airlock and equipment hatch Personnel Airlock Component Commodity Group Constituents:

Component/Commodity Group Structure No 8010S01 Bldg 200: Reactor Containment Building Equipment Hatch

5. Personnel airlock and equipment hatch Personnel Airlock Component Commodity Group Constituents:

Component/Commodity Group Structure No 8010S01 Bldg 200: Reactor Containment Building Moisture barrier.

6. Seals, gaskets, and moisture barriers Seals & gaskets.

Component Commodity Group Constituents:

Component/Commodity Group Structure No 8010S01 Bldg 200: Reactor Containment Building Concrete Sump

7. Concrete elements:foundation, walls, dome.

Reinforced Concrete (Cylinder Wall, Dome, Basemat).

Component Commodity Group Constituents:

Component/Commodity Group Structure No 8010S01 Bldg 200: Reactor Containment Building Containment liner plate (includes liner attachments and liner anchors).

12. Steel elements: liner plate, containment shell Wednesday, October 23, 2002 Page 1 of 16 NRC: Table 3-x-1 Table 2 w/ Union Query

TABLE 3.5-1 TABLE 2 CONTAINMENTS, STRUCTURES, AND COMPONENT SUPPORT Component Commodity Group Constituents:

Component/Commodity Group Structure No 2080S01 Tank: Refueling Water Storage Anchor bolt chair for tank foundation

16. All Groups except Group 6:

accessible interior/exterior concrete & steel components Structure No 3010S01 Tank: Steam Generator Blowdown Structural steel (beams, plates, connectors, column)

16. All Groups except Group 6:

accessible interior/exterior concrete & steel components Structure No 3070S01 Tank: Condensate Storage Anchor bolt chair for tank foundation

16. All Groups except Group 6:

accessible interior/exterior concrete & steel components Structure No 4015S02 Bldg N/A: Intake Structure Electrical & Instrument Panels and Enclosures.

16. All Groups except Group 6:

accessible interior/exterior concrete & steel components Manhole covers Protective Enclosure.

Siding.

Structural steel (beams, plates, connectors, column)

Structure No 4060S01 Bldg N/A: North Service Water Header Enclosure Electrical & Instrument Panels and Enclosures.

16. All Groups except Group 6:

accessible interior/exterior concrete & steel components Structural steel (beams, plates, connectors, column)

Structure No 5100S01 Tank: Diesel Generator Fuel Oil Storage Anchor bolt chair for tank foundation

16. All Groups except Group 6:

accessible interior/exterior concrete & steel components Structural steel (beams, plates, connectors, column)

Structure No 5100S02 Tank: DS Diesel Fuel Oil Miscellaneous steel (Stairs & Ladders, platforms & connectors, grating &

checker

16. All Groups except Group 6:

accessible interior/exterior concrete & steel components Structural steel (beams, plates, connectors, column)

Structure No 5100S03 Tank: Diesel Fire Pump Fuel Oil Miscellaneous steel (Stairs & Ladders, platforms & connectors, grating &

checker

16. All Groups except Group 6:

accessible interior/exterior concrete & steel components Wednesday, October 23, 2002 Page 2 of 16 NRC: Table 3-x-1 Table 2 w/ Union Query

TABLE 3.5-1 TABLE 2 CONTAINMENTS, STRUCTURES, AND COMPONENT SUPPORT Component Commodity Group Constituents:

Component/Commodity Group Structural steel (beams, plates, connectors, column)

16. All Groups except Group 6:

accessible interior/exterior concrete & steel components Structure No 6082S01 Bldg 310: EOF/TSC Security Emergency Diesel Generator Bldg Doors

16. All Groups except Group 6:

accessible interior/exterior concrete & steel components Electrical & Instrument Panels and Enclosures.

Protective Enclosure.

Structural steel (beams, plates, connectors, column)

Structure No 6110S01 Bldg N/A: Security Lighting Manhole covers

16. All Groups except Group 6:

accessible interior/exterior concrete & steel components Siding.

Structure No 8010S01 Bldg 200: Reactor Containment Building Electrical & Instrument Panels and Enclosures.

16. All Groups except Group 6:

accessible interior/exterior concrete & steel components Fire Hose Station.

Floor Drains.

Miscellaneous steel (Stairs & Ladders, platforms & connectors, grating &

checker Protective Enclosure.

Reactor Vessel Missile Shield Frame.

Structural steel (beams, plates, connectors, column)

Sump screens.

Structure No 8300S09 Bldg 210: Radwaste Building Structural steel (beams, plates, connectors, column)

16. All Groups except Group 6:

accessible interior/exterior concrete & steel components Structure No 8300S18 Bldg 340: Dedicated Shutdown (DS) Diesel Generator Building Anchor bolt chair for tank foundation

16. All Groups except Group 6:

accessible interior/exterior concrete & steel components Electrical & Instrument Panels and Enclosures.

Structural steel (beams, plates, connectors, column)

Structure No 8300S36 Bldg 350: Turbine Building Wednesday, October 23, 2002 Page 3 of 16 NRC: Table 3-x-1 Table 2 w/ Union Query

TABLE 3.5-1 TABLE 2 CONTAINMENTS, STRUCTURES, AND COMPONENT SUPPORT Component Commodity Group Constituents:

Component/Commodity Group Doors

16. All Groups except Group 6:

accessible interior/exterior concrete & steel components Electrical & Instrument Panels and Enclosures.

Louvers Miscellaneous steel (Stairs & Ladders, platforms & connectors, grating &

checker Protective Enclosure.

Siding.

Spray shields Structural steel (beams, plates, connectors, column)

Structure No 8300S44 Electrical Manholes and Duct Banks Electrical & Instrument Panels and Enclosures.

16. All Groups except Group 6:

accessible interior/exterior concrete & steel components Manhole covers Structure No 8300S46 Bldgs 215, 220 and 225: Fuel Handling Building Doors

16. All Groups except Group 6:

accessible interior/exterior concrete & steel components Electrical & Instrument Panels and Enclosures.

Miscellaneous steel (Stairs & Ladders, platforms & connectors, grating &

checker Siding.

Structural steel (beams, plates, connectors, column)

Structure No 8300S48 Pipe Restraint Tower Electrical & Instrument Panels and Enclosures.

16. All Groups except Group 6:

accessible interior/exterior concrete & steel components Miscellaneous steel (Stairs & Ladders, platforms & connectors, grating &

checker Structural steel (beams, plates, connectors, column)

Structure No 8300S49 Concrete Trenches Miscellaneous steel (Stairs & Ladders, platforms & connectors, grating &

checker

16. All Groups except Group 6:

accessible interior/exterior concrete & steel components Structure No 8300S55 Bldg N/A: Miscellaneous Yard Structures Electrical & Instrument Panels and Enclosures.

16. All Groups except Group 6:

accessible interior/exterior concrete & steel components Wednesday, October 23, 2002 Page 4 of 16 NRC: Table 3-x-1 Table 2 w/ Union Query

TABLE 3.5-1 TABLE 2 CONTAINMENTS, STRUCTURES, AND COMPONENT SUPPORT Component Commodity Group Constituents:

Component/Commodity Group Protective Enclosure.

16. All Groups except Group 6:

accessible interior/exterior concrete & steel components Structure No 8320S01 Bldg 205: Reactor Auxiliary Building Doors

16. All Groups except Group 6:

accessible interior/exterior concrete & steel components Electrical & Instrument Panels and Enclosures.

Fire Hose Station.

Floor Drains.

Louvers Miscellaneous steel (Stairs & Ladders, platforms & connectors, grating &

checker Protective Enclosure.

Siding.

Spray shields Structural steel (beams, plates, connectors, column)

Component Commodity Group Constituents:

Component/Commodity Group Structure No 2080S01 Tank: Refueling Water Storage Concrete Tank Foundation

17. Groups 1-3, 5, 7-9:

inaccessible concrete components, such as exterior walls below grade and foundation Structure No 3010S01 Tank: Steam Generator Blowdown Concrete Tank Foundation

17. Groups 1-3, 5, 7-9:

inaccessible concrete components, such as exterior walls below grade and foundation Reinforced Concrete (beams, walls, floors, columns, etc.)

Structure No 3070S01 Tank: Condensate Storage Concrete Tank Foundation

17. Groups 1-3, 5, 7-9:

inaccessible concrete components, such as exterior walls below grade and foundation Reinforced Concrete (beams, walls, floors, columns, etc.)

Structure No 4015S02 Bldg N/A: Intake Structure Concrete Fill

17. Groups 1-3, 5, 7-9:

inaccessible concrete components, such as exterior walls below grade and foundation Reinforced Concrete (beams, walls, floors, columns, etc.)

Wednesday, October 23, 2002 Page 5 of 16 NRC: Table 3-x-1 Table 2 w/ Union Query

TABLE 3.5-1 TABLE 2 CONTAINMENTS, STRUCTURES, AND COMPONENT SUPPORT Component Commodity Group Constituents:

Component/Commodity Group Structure No 4060S01 Bldg N/A: North Service Water Header Enclosure Concrete Fill

17. Groups 1-3, 5, 7-9:

inaccessible concrete components, such as exterior walls below grade and foundation Structure No 5100S01 Tank: Diesel Generator Fuel Oil Storage Concrete Tank Foundation

17. Groups 1-3, 5, 7-9:

inaccessible concrete components, such as exterior walls below grade and foundation Reinforced Concrete (beams, walls, floors, columns, etc.)

Structure No 5100S02 Tank: DS Diesel Fuel Oil Reinforced Concrete (beams, walls, floors, columns, etc.)

17. Groups 1-3, 5, 7-9:

inaccessible concrete components, such as exterior walls below grade and foundation Structure No 5100S03 Tank: Diesel Fire Pump Fuel Oil Reinforced Concrete (beams, walls, floors, columns, etc.)

17. Groups 1-3, 5, 7-9:

inaccessible concrete components, such as exterior walls below grade and foundation Structure No 5100S04 Tanks: Unit 1 IC Fuel Oil Storage Facility Concrete Tank Foundation

17. Groups 1-3, 5, 7-9:

inaccessible concrete components, such as exterior walls below grade and foundation Structure No 5114S01 Bldg N/A: DSS-Main-XFMR Reinforced Concrete (beams, walls, floors, columns, etc.)

17. Groups 1-3, 5, 7-9:

inaccessible concrete components, such as exterior walls below grade and foundation Structure No 6082S01 Bldg 310: EOF/TSC Security Emergency Diesel Generator Bldg Reinforced Concrete (beams, walls, floors, columns, etc.)

17. Groups 1-3, 5, 7-9:

inaccessible concrete components, such as exterior walls below grade and foundation Structure No 6110S01 Bldg N/A: Security Lighting Electrical Manhole

17. Groups 1-3, 5, 7-9:

inaccessible concrete components, such as exterior walls below grade and foundation Wednesday, October 23, 2002 Page 6 of 16 NRC: Table 3-x-1 Table 2 w/ Union Query

TABLE 3.5-1 TABLE 2 CONTAINMENTS, STRUCTURES, AND COMPONENT SUPPORT Component Commodity Group Constituents:

Component/Commodity Group Reinforced Concrete (beams, walls, floors, columns, etc.)

17. Groups 1-3, 5, 7-9:

inaccessible concrete components, such as exterior walls below grade and foundation Underground Conduit Duct bank Structure No 8010S01 Bldg 200: Reactor Containment Building External Reinforced Concrete Components (Missile Shield slabs, walls, roof slabs

17. Groups 1-3, 5, 7-9:

inaccessible concrete components, such as exterior walls below grade and foundation Structure No 8300S09 Bldg 210: Radwaste Building Reinforced Concrete (beams, walls, floors, columns, etc.)

17. Groups 1-3, 5, 7-9:

inaccessible concrete components, such as exterior walls below grade and foundation Structure No 8300S18 Bldg 340: Dedicated Shutdown (DS) Diesel Generator Building Reinforced Concrete (beams, walls, floors, columns, etc.)

17. Groups 1-3, 5, 7-9:

inaccessible concrete components, such as exterior walls below grade and foundation Structure No 8300S36 Bldg 350: Turbine Building Reinforced Concrete (beams, walls, floors, columns, etc.)

17. Groups 1-3, 5, 7-9:

inaccessible concrete components, such as exterior walls below grade and foundation Structure No 8300S44 Electrical Manholes and Duct Banks Grout

17. Groups 1-3, 5, 7-9:

inaccessible concrete components, such as exterior walls below grade and foundation Reinforced Concrete (beams, walls, floors, columns, etc.)

Structure No 8300S46 Bldgs 215, 220 and 225: Fuel Handling Building Reinforced Concrete (beams, walls, floors, columns, etc.)

17. Groups 1-3, 5, 7-9:

inaccessible concrete components, such as exterior walls below grade and foundation Structure No 8300S48 Pipe Restraint Tower Reinforced Concrete (beams, walls, floors, columns, etc.)

17. Groups 1-3, 5, 7-9:

inaccessible concrete components, such as exterior walls below grade and foundation Wednesday, October 23, 2002 Page 7 of 16 NRC: Table 3-x-1 Table 2 w/ Union Query

TABLE 3.5-1 TABLE 2 CONTAINMENTS, STRUCTURES, AND COMPONENT SUPPORT Component Commodity Group Constituents:

Component/Commodity Group Structure No 8300S49 Concrete Trenches Reinforced Concrete (beams, walls, floors, columns, etc.)

17. Groups 1-3, 5, 7-9:

inaccessible concrete components, such as exterior walls below grade and foundation Structure No 8300S55 Bldg N/A: Miscellaneous Yard Structures Reinforced Concrete (beams, walls, floors, columns, etc.)

17. Groups 1-3, 5, 7-9:

inaccessible concrete components, such as exterior walls below grade and foundation Structure No 8320S01 Bldg 205: Reactor Auxiliary Building Concrete Sump

17. Groups 1-3, 5, 7-9:

inaccessible concrete components, such as exterior walls below grade and foundation Reinforced Concrete (beams, walls, floors, columns, etc.)

Component Commodity Group Constituents:

Component/Commodity Group Structure No 4045S01 Reservoir and Dam Anchorage/ Embedments - Exposed Surfaces

18. Group 6: all accessible/inacce-ssible concrete, steel, and earthen components Lake Dam Spillway for Dam Structure Structural steel (beams, plates, connectors, column)

Tainter Gate (Dam)

Threaded fasteners.

Component Commodity Group Constituents:

Component/Commodity Group Structure No 8010S01 Bldg 200: Reactor Containment Building Bellows

19. Group 5:liners Cavity Seal Ring Plate Fuel transfer tube.

NIS Detector Cover.

Reactor Cavity Liner Plate Reactor manway covers.

Structure No 8300S46 Bldgs 215, 220 and 225: Fuel Handling Building Bellows

19. Group 5:liners SF Pool Liner Component Commodity Group Constituents:

Component/Commodity Group Wednesday, October 23, 2002 Page 8 of 16 NRC: Table 3-x-1 Table 2 w/ Union Query

TABLE 3.5-1 TABLE 2 CONTAINMENTS, STRUCTURES, AND COMPONENT SUPPORT Component Commodity Group Constituents:

Component/Commodity Group Structure No 2080S01 Tank: Refueling Water Storage Anchorage/ Embedments - Exposed Surfaces

25. All Groups: support members: anchor bolts, concrete surrounding anchor bolts, welds, grout pad, bolted connections, etc.

Structure No 3010S01 Tank: Steam Generator Blowdown Anchorage/ Embedments - Exposed Surfaces

25. All Groups: support members: anchor bolts, concrete surrounding anchor bolts, welds, grout pad, bolted connections, etc.

Pipe Supports Threaded fasteners.

Structure No 3070S01 Tank: Condensate Storage Anchorage/ Embedments - Exposed Surfaces

25. All Groups: support members: anchor bolts, concrete surrounding anchor bolts, welds, grout pad, bolted connections, etc.

Electrical component supports.

Pipe Supports Structure No 4015S02 Bldg N/A: Intake Structure Anchorage/ Embedments - Exposed Surfaces

25. All Groups: support members: anchor bolts, concrete surrounding anchor bolts, welds, grout pad, bolted connections, etc.

Battery Rack Electrical component supports.

Expansion Anchors Instrument Racks and Frames.

Pipe Supports Structure No 4060S01 Bldg N/A: North Service Water Header Enclosure Anchorage/ Embedments - Exposed Surfaces

25. All Groups: support members: anchor bolts, concrete surrounding anchor bolts, welds, grout pad, bolted connections, etc.

Electrical component supports.

Expansion Anchors Instrument Line Supports.

Wednesday, October 23, 2002 Page 9 of 16 NRC: Table 3-x-1 Table 2 w/ Union Query

TABLE 3.5-1 TABLE 2 CONTAINMENTS, STRUCTURES, AND COMPONENT SUPPORT Component Commodity Group Constituents:

Component/Commodity Group Pipe Supports

25. All Groups: support members: anchor bolts, concrete surrounding anchor bolts, welds, grout pad, bolted connections, etc.

Threaded fasteners.

Structure No 5100S01 Tank: Diesel Generator Fuel Oil Storage Anchorage/ Embedments - Exposed Surfaces

25. All Groups: support members: anchor bolts, concrete surrounding anchor bolts, welds, grout pad, bolted connections, etc.

Electrical component supports.

Expansion Anchors Pipe Supports Structure No 5100S02 Tank: DS Diesel Fuel Oil Anchorage/ Embedments - Exposed Surfaces

25. All Groups: support members: anchor bolts, concrete surrounding anchor bolts, welds, grout pad, bolted connections, etc.

Electrical component supports.

Expansion Anchors Pipe Supports Structure No 5100S03 Tank: Diesel Fire Pump Fuel Oil Anchorage/ Embedments - Exposed Surfaces

25. All Groups: support members: anchor bolts, concrete surrounding anchor bolts, welds, grout pad, bolted connections, etc.

Expansion Anchors Pipe Supports Structure No 5100S04 Tanks: Unit 1 IC Fuel Oil Storage Facility Anchorage/ Embedments - Exposed Surfaces

25. All Groups: support members: anchor bolts, concrete surrounding anchor bolts, welds, grout pad, bolted connections, etc.

Structure No 5114S01 Bldg N/A: DSS-Main-XFMR Wednesday, October 23, 2002 Page 10 of 16 NRC: Table 3-x-1 Table 2 w/ Union Query

TABLE 3.5-1 TABLE 2 CONTAINMENTS, STRUCTURES, AND COMPONENT SUPPORT Component Commodity Group Constituents:

Component/Commodity Group Anchorage/ Embedments - Exposed Surfaces

25. All Groups: support members: anchor bolts, concrete surrounding anchor bolts, welds, grout pad, bolted connections, etc.

Electrical component supports.

Structure No 6082S01 Bldg 310: EOF/TSC Security Emergency Diesel Generator Bldg Anchorage/ Embedments - Exposed Surfaces

25. All Groups: support members: anchor bolts, concrete surrounding anchor bolts, welds, grout pad, bolted connections, etc.

Battery Rack Electrical component supports.

Expansion Anchors Pipe Supports Threaded fasteners.

Vibration Isolators.

Structure No 6110S01 Bldg N/A: Security Lighting Anchorage/ Embedments - Exposed Surfaces

25. All Groups: support members: anchor bolts, concrete surrounding anchor bolts, welds, grout pad, bolted connections, etc.

Electrical component supports.

Structure No 8010S01 Bldg 200: Reactor Containment Building Anchorage/ Embedments - Exposed Surfaces

25. All Groups: support members: anchor bolts, concrete surrounding anchor bolts, welds, grout pad, bolted connections, etc.

Electrical component supports.

Equipment Supports.

Expansion Anchors HVAC Duct Supports.

Instrument Line Supports.

Instrument Racks and Frames.

Pipe Supports Pipe whip restraints Slide bearing plates Threaded fasteners.

Tube Track Supports.

Wednesday, October 23, 2002 Page 11 of 16 NRC: Table 3-x-1 Table 2 w/ Union Query

TABLE 3.5-1 TABLE 2 CONTAINMENTS, STRUCTURES, AND COMPONENT SUPPORT Component Commodity Group Constituents:

Component/Commodity Group Vibration Isolators.

25. All Groups: support members: anchor bolts, concrete surrounding anchor bolts, welds, grout pad, bolted connections, etc.

Structure No 8300S09 Bldg 210: Radwaste Building Anchorage/ Embedments - Exposed Surfaces

25. All Groups: support members: anchor bolts, concrete surrounding anchor bolts, welds, grout pad, bolted connections, etc.

Expansion Anchors Pipe Supports Threaded fasteners.

Structure No 8300S18 Bldg 340: Dedicated Shutdown (DS) Diesel Generator Building Anchorage/ Embedments - Exposed Surfaces

25. All Groups: support members: anchor bolts, concrete surrounding anchor bolts, welds, grout pad, bolted connections, etc.

Battery Rack Electrical component supports.

Equipment Supports.

Expansion Anchors Instrument Racks and Frames.

Pipe Supports Threaded fasteners.

Structure No 8300S36 Bldg 350: Turbine Building Anchorage/ Embedments - Exposed Surfaces

25. All Groups: support members: anchor bolts, concrete surrounding anchor bolts, welds, grout pad, bolted connections, etc.

Battery Rack Cable tray and conduit.

Electrical Bus Duct (Enclosure)

Electrical component supports.

Equipment Supports.

Expansion Anchors Instrument Line Supports.

Instrument Racks and Frames.

Pipe Supports Wednesday, October 23, 2002 Page 12 of 16 NRC: Table 3-x-1 Table 2 w/ Union Query

TABLE 3.5-1 TABLE 2 CONTAINMENTS, STRUCTURES, AND COMPONENT SUPPORT Component Commodity Group Constituents:

Component/Commodity Group Pipe whip restraints

25. All Groups: support members: anchor bolts, concrete surrounding anchor bolts, welds, grout pad, bolted connections, etc.

Threaded fasteners.

Tube Track Supports.

Structure No 8300S44 Electrical Manholes and Duct Banks Anchorage/ Embedments - Exposed Surfaces

25. All Groups: support members: anchor bolts, concrete surrounding anchor bolts, welds, grout pad, bolted connections, etc.

Expansion Anchors Pipe Supports Structure No 8300S46 Bldgs 215, 220 and 225: Fuel Handling Building Anchorage/ Embedments - Exposed Surfaces

25. All Groups: support members: anchor bolts, concrete surrounding anchor bolts, welds, grout pad, bolted connections, etc.

Electrical component supports.

Expansion Anchors HVAC Duct Supports.

Instrument Line Supports.

Instrument Racks and Frames.

Pipe Supports Tube Track Supports.

Structure No 8300S48 Pipe Restraint Tower Anchorage/ Embedments - Exposed Surfaces

25. All Groups: support members: anchor bolts, concrete surrounding anchor bolts, welds, grout pad, bolted connections, etc.

Electrical component supports.

Instrument Line Supports.

Pipe Supports Pipe whip restraints Threaded fasteners.

Structure No 8300S49 Concrete Trenches Wednesday, October 23, 2002 Page 13 of 16 NRC: Table 3-x-1 Table 2 w/ Union Query

TABLE 3.5-1 TABLE 2 CONTAINMENTS, STRUCTURES, AND COMPONENT SUPPORT Component Commodity Group Constituents:

Component/Commodity Group Anchorage/ Embedments - Exposed Surfaces

25. All Groups: support members: anchor bolts, concrete surrounding anchor bolts, welds, grout pad, bolted connections, etc.

Expansion Anchors Pipe Supports Threaded fasteners.

Structure No 8300S55 Bldg N/A: Miscellaneous Yard Structures Anchorage/ Embedments - Exposed Surfaces

25. All Groups: support members: anchor bolts, concrete surrounding anchor bolts, welds, grout pad, bolted connections, etc.

Electrical component supports.

Expansion Anchors Pipe Supports Structure No 8320S01 Bldg 205: Reactor Auxiliary Building Anchorage/ Embedments - Exposed Surfaces

25. All Groups: support members: anchor bolts, concrete surrounding anchor bolts, welds, grout pad, bolted connections, etc.

Battery Rack Cable tray and conduit.

Damper mounting Electrical Bus Duct (Enclosure)

Electrical component supports.

Equipment Supports.

Expansion Anchors HVAC Duct Supports.

Instrument Line Supports.

Instrument Racks and Frames.

Pipe Supports Pipe whip restraints Threaded fasteners.

Tube Track Supports.

Vibration Isolators.

Component Commodity Group Constituents:

Component/Commodity Group Structure No 8010S01 Bldg 200: Reactor Containment Building Wednesday, October 23, 2002 Page 14 of 16 NRC: Table 3-x-1 Table 2 w/ Union Query

TABLE 3.5-1 TABLE 2 CONTAINMENTS, STRUCTURES, AND COMPONENT SUPPORT Component Commodity Group Constituents:

Component/Commodity Group Anchorage/ Embedments - Exposed Surfaces

27. All Groups: support members: anchor bolts, welds Electrical component supports.

Equipment Supports.

Expansion Anchors HVAC Duct Supports.

Instrument Line Supports.

Instrument Racks and Frames.

Pipe Supports Pipe whip restraints Pressurizer Support Pressurizer Surge Line Supports Reactor Coolant Pump Supports Slide bearing plates Steam Generator Supports Threaded fasteners.

Tube Track Supports.

Vibration Isolators.

Structure No 8300S46 Bldgs 215, 220 and 225: Fuel Handling Building Anchorage/ Embedments - Exposed Surfaces

27. All Groups: support members: anchor bolts, welds Electrical component supports.

Expansion Anchors HVAC Duct Supports.

Instrument Line Supports.

Pipe Supports Structure No 8320S01 Bldg 205: Reactor Auxiliary Building Anchorage/ Embedments - Exposed Surfaces

27. All Groups: support members: anchor bolts, welds Electrical component supports.

Equipment Supports.

Expansion Anchors Instrument Line Supports.

Pipe Supports Wednesday, October 23, 2002 Page 15 of 16 NRC: Table 3-x-1 Table 2 w/ Union Query

TABLE 3.5-1 TABLE 2 CONTAINMENTS, STRUCTURES, AND COMPONENT SUPPORT Component Commodity Group Constituents:

Component/Commodity Group Structure No 8010S01 Bldg 200: Reactor Containment Building Anchorage/ Embedments - Exposed Surfaces

28. Groups B1.1, B1.2, and B1.3: support members: anchor bolts, welds, spring hangers, guides, stops, and vibration isolators Expansion Anchors Pipe Supports Pressurizer Support Pressurizer Surge Line Supports Reactor Coolant Pump Supports Reactor Vessel Support Slide bearing plates Steam Generator Supports Threaded fasteners.

Structure No 8300S36 Bldg 350: Turbine Building Pipe Supports

28. Groups B1.1, B1.2, and B1.3: support members: anchor bolts, welds, spring hangers, guides, stops, and vibration isolators Structure No 8300S46 Bldgs 215, 220 and 225: Fuel Handling Building Pipe Supports
28. Groups B1.1, B1.2, and B1.3: support members: anchor bolts, welds, spring hangers, guides, stops, and vibration isolators Structure No 8320S01 Bldg 205: Reactor Auxiliary Building Pipe Supports
28. Groups B1.1, B1.2, and B1.3: support members: anchor bolts, welds, spring hangers, guides, stops, and vibration isolators Wednesday, October 23, 2002 Page 16 of 16 NRC: Table 3-x-1 Table 2 w/ Union Query