Part 12 of 17, CD-ROM Providing the Review Tool Supporting the Application for Renewal of Operating License
ML023170591
Person / Time
Site: Robinson Duke Energy icon.png
Issue date: 11/06/2002
From: Fletcher B
Carolina Power & Light Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
RNP-RA/02-0164
Download: ML023170591 (5)


Text

TABLE 3.4-1 TABLE 1 STEAM AND POWER CONVERSION SYSTEMS Steam and Power Conversion Systems Program Aging Effect/ Mechanism Material Environment

1. Piping and fittings in main feedwater line, steam line and AFW piping (PWR only)

System No 3010 Steam Generator Blowdown System Treated Water (including steam)

Fatigue is a TLAA to be evaluated Carbon Steel Cracking from Thermal Fatigue Treated Water (including steam)

Fatigue is a TLAA to be evaluated Stainless Steel Cracking from Thermal Fatigue System No 3015 Steam Generator Chemical Addition System Treated Water (including steam)

Fatigue is a TLAA to be evaluated Carbon Steel Cracking from Thermal Fatigue System No 3020 Main Steam (MS)

Treated Water (including steam)

Fatigue is a TLAA to be evaluated Carbon Steel Cracking from Thermal Fatigue Treated Water (including steam)

Fatigue is a TLAA to be evaluated Stainless Steel Cracking from Thermal Fatigue System No 3050 Feedwater System (FW)

Treated Water (including steam)

Fatigue is a TLAA to be evaluated Carbon Steel Cracking from Thermal Fatigue Treated Water (including steam)

Fatigue is a TLAA to be evaluated Stainless Steel Cracking from Thermal Fatigue System No 3065 Auxiliary Feedwater (AFW)

Treated Water (including steam)

Fatigue is a TLAA to be evaluated Carbon Steel Cracking from Thermal Fatigue

2. Piping and fittings, valve bodies and bonnets, pump casings, tanks, tubes, tubesheets, channel head and shell (except main steam system)

System No 3010 Steam Generator Blowdown System Treated Water (including steam)

Water Chemistry Program Carbon Steel Loss of Material from Crevice Corrosion Treated Water (including steam)

Water Chemistry Program Loss of Material from General Corrosion Treated Water (including steam)

Water Chemistry Program Loss of Material from Pitting Corrosion Treated Water (including steam)

Water Chemistry Program Stainless Steel Loss of Material from Crevice Corrosion Treated Water (including steam)

Water Chemistry Program Loss of Material from Pitting Corrosion Tuesday, October 08, 2002 Page 1 of 5 Rpt: NRC: Table 3-x-1 Table 1 w/ Union Query

TABLE 3.4-1 TABLE 1 STEAM AND POWER CONVERSION SYSTEMS Steam and Power Conversion Systems Program Aging Effect/ Mechanism Material Environment

2. Piping and fittings, valve bodies and bonnets, pump casings, tanks, tubes, tubesheets, channel head and shell (except main steam system)

System No 3015 Steam Generator Chemical Addition System Treated Water (including steam)

Water Chemistry Program Carbon Steel Loss of Material from Crevice Corrosion Treated Water (including steam)

Water Chemistry Program Loss of Material from General Corrosion Treated Water (including steam)

Water Chemistry Program Loss of Material from Pitting Corrosion System No 3050 Feedwater System (FW)

Treated Water (including steam)

Water Chemistry Program Carbon Steel Loss of Material from Crevice Corrosion Treated Water (including steam)

Water Chemistry Program Loss of Material from General Corrosion Treated Water (including steam)

Water Chemistry Program Loss of Material from Pitting Corrosion Treated Water (including steam)

Water Chemistry Program Stainless Steel Loss of Material from Crevice Corrosion Treated Water (including steam)

Water Chemistry Program Loss of Material from Pitting Corrosion System No 3065 Auxiliary Feedwater (AFW)

Treated Water (including steam)

Water Chemistry Program Carbon Steel Loss of Material from Crevice Corrosion Treated Water (including steam)

Water Chemistry Program Loss of Material from General Corrosion Treated Water (including steam)

Water Chemistry Program Loss of Material from Pitting Corrosion Treated Water (including steam)

Water Chemistry Program Stainless Steel Loss of Material from Crevice Corrosion Treated Water (including steam)

Water Chemistry Program Loss of Material from Pitting Corrosion System No 3070 Condensate System (C)

Treated Water (including steam)

Water Chemistry Program Carbon Steel Loss of Material from Crevice Corrosion Treated Water (including steam)

Water Chemistry Program Loss of Material from General Corrosion Treated Water (including steam)

Water Chemistry Program Loss of Material from Pitting Corrosion Treated Water (including steam)

Water Chemistry Program Stainless Steel Loss of Material from Crevice Corrosion Treated Water (including steam)

Water Chemistry Program Loss of Material from Pitting Corrosion Tuesday, October 08, 2002 Page 2 of 5 Rpt: NRC: Table 3-x-1 Table 1 w/ Union Query

TABLE 3.4-1 TABLE 1 STEAM AND POWER CONVERSION SYSTEMS Steam and Power Conversion Systems Program Aging Effect/ Mechanism Material Environment

5. External surface of carbon steel components System No 3010 Steam Generator Blowdown System Indoor - Not Air Conditioned, Outdoor Systems Monitoring Program (Site Specific)

Carbon Steel Loss of Material from General Corrosion System No 3015 Steam Generator Chemical Addition System Outdoor Systems Monitoring Program (Site Specific)

Carbon Steel Loss of Material from General Corrosion System No 3020 Main Steam (MS)

Indoor - Not Air Conditioned, Outdoor Systems Monitoring Program (Site Specific)

Carbon Steel Loss of Material from General Corrosion Outdoor Systems Monitoring Program (Site Specific)

Loss of Material from General Corrosion System No 3050 Feedwater System (FW)

Indoor - Not Air Conditioned, Outdoor Systems Monitoring Program (Site Specific)

Carbon Steel Loss of Material from General Corrosion Outdoor Systems Monitoring Program (Site Specific)

Loss of Material from General Corrosion System No 3070 Condensate System (C)

Outdoor Systems Monitoring Program (Site Specific)

Carbon Steel Loss of Material from General Corrosion

6. Carbon steel piping and valve bodies System No 3010 Steam Generator Blowdown System Treated Water (including steam)

Flow-Accelerated Corrosion Program Carbon Steel Loss of Material from FAC System No 3020 Main Steam (MS)

Treated Water (including steam)

Flow-Accelerated Corrosion Program Carbon Steel Loss of Material from FAC System No 3050 Feedwater System (FW)

Treated Water (including steam)

Flow-Accelerated Corrosion Program Carbon Steel Loss of Material from FAC System No 3065 Auxiliary Feedwater (AFW)

Tuesday, October 08, 2002 Page 3 of 5 Rpt: NRC: Table 3-x-1 Table 1 w/ Union Query

TABLE 3.4-1 TABLE 1 STEAM AND POWER CONVERSION SYSTEMS Steam and Power Conversion Systems Program Aging Effect/ Mechanism Material Environment

6. Carbon steel piping and valve bodies Treated Water (including steam)

Flow-Accelerated Corrosion Program Carbon Steel Loss of Material from FAC System No 3070 Condensate System (C)

Treated Water (including steam)

Flow-Accelerated Corrosion Program Carbon Steel Loss of Material from FAC

7. Carbon steel piping and valve bodies in main steam system System No 3020 Main Steam (MS)

Treated Water (including steam)

Water Chemistry Program Carbon Steel Loss of Material from Crevice Corrosion Treated Water (including steam)

Water Chemistry Program Loss of Material from Pitting Corrosion

9. Heat exchangers and coolers/ condensers serviced by open-cycle cooling water System No 3065 Auxiliary Feedwater (AFW)

Raw Water Open-Cycle Cooling Water System Program Carbon Steel Flow Blockage from Fouling Raw Water Open-Cycle Cooling Water System Program Loss of Material from Crevice Corrosion Raw Water Open-Cycle Cooling Water System Program Loss of Material from General Corrosion Raw Water Open-Cycle Cooling Water System Program Loss of Material from MIC Raw Water Open-Cycle Cooling Water System Program Loss of Material from Pitting Corrosion

10. Heat exchangers and coolers/ condensers serviced by closed-cycle cooling water System No 4080 Component/Closed Cooling Water System Treated Water (including steam)

Closed-Cycle Cooling Water System Program Carbon Steel Loss of Material from Crevice Corrosion Treated Water (including steam)

Closed-Cycle Cooling Water System Program Loss of Material from General Corrosion Treated Water (including steam)

Closed-Cycle Cooling Water System Program Loss of Material from Pitting Corrosion Treated Water (including steam)

Closed-Cycle Cooling Water System Program Stainless Steel Loss of Material from Crevice Corrosion Treated Water (including steam)

Closed-Cycle Cooling Water System Program Loss of Material from Pitting Corrosion Tuesday, October 08, 2002 Page 4 of 5 Rpt: NRC: Table 3-x-1 Table 1 w/ Union Query

TABLE 3.4-1 TABLE 1 STEAM AND POWER CONVERSION SYSTEMS Steam and Power Conversion Systems Program Aging Effect/ Mechanism Material Environment

13. External surface of carbon steel components System No 3010 Steam Generator Blowdown System Containment Air, Borated Water Leakage Boric Acid Corrosion Program Carbon Steel Loss of Material from Aggressive Chemical Attack Containment Air, Borated Water Leakage Boric Acid Corrosion Program Loss of Mechanical Closure Integrity from Loss of Material due to Aggressive Chemical Attack System No 3020 Main Steam (MS)

Containment Air, Borated Water Leakage Boric Acid Corrosion Program Carbon Steel Loss of Material from Aggressive Chemical Attack Containment Air, Borated Water Leakage Boric Acid Corrosion Program Loss of Mechanical Closure Integrity from Loss of Material due to Aggressive Chemical Attack System No 3050 Feedwater System (FW)

Containment Air, Borated Water Leakage Boric Acid Corrosion Program Carbon Steel Loss of Material from Aggressive Chemical Attack Containment Air, Borated Water Leakage Boric Acid Corrosion Program Loss of Mechanical Closure Integrity from Loss of Material due to Aggressive Chemical Attack System No 3065 Auxiliary Feedwater (AFW)

Containment Air, Borated Water Leakage Boric Acid Corrosion Program Carbon Steel Loss of Material from Aggressive Chemical Attack Containment Air, Borated Water Leakage Boric Acid Corrosion Program Loss of Mechanical Closure Integrity from Loss of Material due to Aggressive Chemical Attack System No 4080 Component/Closed Cooling Water System Indoor - Not Air Conditioned, Borated Water Leakage Boric Acid Corrosion Program Carbon Steel Loss of Material from Aggressive Chemical Attack Tuesday, October 08, 2002 Page 5 of 5 Rpt: NRC: Table 3-x-1 Table 1 w/ Union Query