Meeting Handouts - Meeting with Strategic Teaming and Resources Sharing - Integrated Regulatory Affairs Group
ML023120024
Person / Time
Site: Wolf Creek, Diablo Canyon, Callaway, Comanche Peak  
Issue date: 11/07/2002
From: Donohew J
NRC/NRR/DLPM/LPD4
To:
References
Download: ML023120024 (13)


Text

NRC FORM 658 U.S. NUCLEAR REGULATORY COMMISSION (9-1999)

TRANSMITTAL OF MEETING HANDOUT MATERIALS FOR IMMEDIATE PLACEMENT IN THE PUBLIC DOMAIN This form is to be filled out (typed or hand-printed) by the person who announced the meeting (i.e., the person who issued the meeting notice). The completed form, and the attached copy of meeting handout materials, will be sent to the Document Control Desk on the same day of the meeting; under no circumstances will this be done later than the working day after the meeting.

Do not include proprietary materials.

DATE OF MEETING The attached document(s), which was/were handed out in this meeting, is/are to be placed 11/07/2002 in the public domain as soon as possible. The minutes of the meeting will be issued in the near future. Following are administrative details regarding this meeting:

Docket Number(s) 50-483, 50-445, 50-446, 50-275, 50-323, 50-482 Plant/Facility Name Callaway, Comanche Peak, Diablo Canyon, Wolf Creek TAC Number(s) (if available)

Not Applicable Reference Meeting Notice ML022740090 dated October 10, 2002 Purpose of Meeting (copy from meeting notice)

Meeting with Strategic Teaming and Resources Sharing Integrated Regulatory Affairs Group NAME OF PERSON WHO ISSUED MEETING NOTICE TITLE Jack Donohew Senior Project Manager OFFICE Office of Nuclear Reactor Regulation DIVISION Division of Licensing Project Management BRANCH Project Directorate IV Distribution of this form and attachments:

Docket File/Central File PUBLIC

This form was designed using InForms

0 0

0 I

0 U

0 0

U H

Ct) 0 0

0 S

0 0

S S

S S

Ct cn 0

(f

0)
  • 0 0

CO rz CO

0)

I C)

CO Cl) 0 40 0

0

.3 I :kz

c(NI CIA ct

Strategic Teaming and Resource Sharing

"* Common Licensing Actions Submitted

- Review Savings

- Burden Reduction

"* Generic Regulatory Issues

- Review of rulemaking, draft regulatory guides, etc.

- Bulletin 2002-01 and 2002-02 Responses

  • Security Order Response 10/31/2002 Successes 3

A

'ff

Strategic Teaming and Resource Sharing Common Licensing Actions

  • Past Common Submittals

- Bases Control Program (50.59 Rule) - TSTF-364

- Risk Informed Inservice Inspection (ISI)

- Elimination of PASS Requirements - TSTF-366

- Low Power Calorimetric - TSTF-371

- Positive Flux Rate Trip 10/31/2002 rI, 4

Strategic Teaming and Resource Sharing Common Licensing Actions

  • Common LARs under review

- Equipment Hatch Open during Fuel Movement (DC)

- Deletion of License Condition for 24 Hour Report (CP)

- Positive Reactivity Additions (DC)

- Reduced NIS Channels (CA, WC) 10/31/2002 5

Strategic Teaming and Resource Shanng Project Description Deletion of TS 5 5 3, Post Accident Sampling (TSTF 366)

STARS Projects NRC Cost Savings Risk Informed Inservice Inspection (Code Case N-578)

Allow the containment equipment hatch open during fuel movement Revision to TS 5.5.14, Bases Control Program (TSTF-364)

Expanded COLOR (TSTF 339

& 363)

Missed Surveillance Requirements SR 3 0 3 (TSTF 358)

Revised Low Power Calorimetric Surveillance (SR 3.3.1.2)

Revision to TS Regarding Suspension of Positive Reactivity Additions NRC Cost Saving Est.

NRC Cost Saving Est.

NRC Cost Saving Est.

NRC Cost Saving Est.

NRC Cost Saving Est.

NRC Cost (4)

Saving Est.

NRC Cost Saving Est NRC Cost Saving Est.

AmerenUE

$99360

$1,556 00

$9,083 40

$25,446 60

$2,670 00

$2,520 00

$1,512 00

$2,232 00 WCNOC

$734 40 NA

$16,985 40

$17,544 60

$4,703 40

$487 60

$691.20

$3,052.80 (2)

$11,18400

$000

$2,250.00

$0.00

$1,500 00

$0.00

$9,105 00

$000

$1,035 00

$1,215 00 (4)

$5,295 00

$3,810 00 LICENSEE TXU

$2,550 00

$000

$34,530 00

$000

$5,190 00

$0.00

$3,744.00

$000 (3)

$1,200 00

$1,050 00 NA (2)

PG&E

$1,152.00

$1398.00

$9,374.40

$25,155.60

$10,215 00 NA

$1,440 00

$2,304 00 (2)

$2,550 00

($300 00)

(2)

(4)

STP APS

$450 00

$210000

$5,423 60

$29,106 40

$10,740 00 NA NA NA (3)

$2,100.00

$150.00 NA (4)

$2,245 00 NA NA NA

$6,255.00 NA

$2,300.00

$1,444.00 NA NA

$1,200 00

$1,050 00 Est. Proiect Cost Savings

$2.550.00

$5,054.40

$34,530.00 TXU

$97,253.20 (1)

$4,703 40

$3007.60

$3,744 00

$9,032 80

$11,184 00

$000

$2,250 00

$3,165 00 NA

$1,500 00

$000 (2)

$9,105 00

$3,810.00 WCNOC TXU WCNOC AUE AUE AUE (1) Estimate additional $50,000 saved (generic review costs spread out among applicants other than TXU)

(2)

Not yet submitted (3)

Approved pre-STARS (4)

More charges expected Lead Utility WCNOC 6

10/31/2002

Strategic Teaming and Resource Shanng Future LARs - Scheduled 2002/03 Licensing Action Participants/

Schedule Lead Plant Priority TSTF-283 Rev. 3, Mode restrictions for CA WC ST CP DC PV Last quarter of CP SRs in Electrical Specifications Y

Y N

Y Y

Y 2002 or early Doug 2003 Spalding TSTF-360, Revision of DC Electrical CA WC ST CP DC PV Last quarter of CP Specifications D

N Y

D 2002 or early Mike 2003 Riggcs TSTF-359 Rev. 7, "Allow mode CA WC ST CP DC PV Last quarter of DC changes when not meeting certain 2002

  • Ken LCOs" Y

Y Y

Y Y

Y Schrader TSTF-370, "Increase in Accumulator CA WC ST CP DC PV Last quarter CP-Bob Completion Time from 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> to 24 A

A A

Y Y

A 2002.

Dacko hours (WCAP-1 5049)," CLIIP Item.

SER in the FR 07/02 with comments due 08/02.

TSTF-411 WCAP-15376,"Risk-CA WC ST CP DC PV Submit end of WC/CA Informed Assessment of the RTS &

Y Y

Y Y

Y N

2nd quarter

- Bert ESFAS Surveillance Test Intervals 2003

Worked together, or back to back.

TSTF-418 WCAP-14333 Rev. 1, CA WC ST CP DC PV Submit end of WC/CA "Relaxation of RPS/ESF Completion Y

Y A

Y Y

N 2nd quarter

- Bert Times" and associated TSTF-418 2003

  • Yates submitted 9/01.
  • - Schedules are dependent on NRC approval of topical reports and/or TSTF.

"& S = submitted, N = No (Not Applicable), Y = Yes (Applies), A = Approved, ? =

Applicability undetermined, D = Deferred 10/31/2002 7

A Strategic Teaming and Resource Sharing Other Future LARs

"* S = submitted, N = No (Not Applicable), Y = Yes (Applies), A = Approved, ? =

10/31/2002 Applicability undetermined, D = Deferred Licensing Action Participants/

P Schedule Lead Plant Priority TSTF-417 WCAP-15622, Extend the CA WC ST CP DC PV H

To be CA - Mike AOTs for AC Electrical Power Systems Y

Y N

Y Y

N submitted by Riggs and supporting TSTF-417 end of 2003

CA WC ST CP DC PV H

Estimate -

CA - Tom Allows removal of the hydrogen y

y y

y y

y Sometime in Elwood recombiners and requirements for 2003 hydrogen (and oxygen) monitors from the TS. In addition will allow downgrading of the quality requirements for hydrogen monitors.

I TSTF-51, "Recently Irradiated Fuel" in CA WC ST CP DC PV M

Second PV place of "Irradiated Fuel" Remove y

y y

y y

y Quarter 2003 Rodney restriction during fuel movement Wilford TSTF-372 Rev. 2, New LCO 3.0.8 for CA WC ST CP DC PV M Third quarter CP Inoperability of Snubbers y

Y N

Y Y

Y 2003

Last half of DC-Ken Steam Supply to Turbine Driven AFW Y

Y N

Y Y

Y 2003 *. Do Schrader Pump Inoperable I

with TSTF-245 TSTF-245 Rev. 1, Operability of AFW CA WC ST CP DC PV M

Last half of DC - Ken System Y

Y A

Y Y

A 2003. Do with Schrader TSTF-412 TSTF-421 WCAP-1 5666, "RCP Flywheel CA WC ST CP DC PV M TBD (2003?)

  • First plant Inspection Elimination Risk Assessment" affected and supporting TSTF-421.

Y Y

Y Y

N Y

"* * - Schedules are dependent on NRC approval of topical reports and/or TSTF.

8

Strategic Teaming and Resource Sharing A

J

i.t o Regulatory Affairs Strategic Issues Group

"* First STARS Center of Business (COB)

"* Staff:

- Manager (IRAG Chairman) - Don Woodlan

- STARS Washington Representative - Rich Luckett

- Projects Manager - Diane Hooper 10/31/2002 RASIG 9

Strategic Teaming and Resource Sharing RASIG Products

"* Strategic Issue Summaries

"* Briefing papers for STARS management

"* Recommended strategies, priorities, actions or comments on regulatory issues in the form of white papers (position papers), draft letters, etc.

10/31/2002 10

(i Jff

Strategic Teaming and Resource Sharing STARS/NRC Licensing Workshop

"* Proposal STARS to host a joint NRC/STARS Region IV Licensing Workshop during 2003

"* Discussion

- Purpose & Goal of Workshop

- NRC Support

- Possible Dates and Locations 10/31/2002 I1I

T:

Strategic Teaming and Resource Sharing Challenges / Areas for Improvement / Lessons Learned

"* Challenges (Security Orders, Steam Generator Inspections, Reactor Vessel Head Inspections)

"* Areas for Improvement / Lessons Learned

- Formats, commonality, parallel versus staggered submittals, lead NRR PMs