From:

Peter Tam To:

INTernet:dosaj@nimo.com; internet:iftikhar.Abbasi@nmp.cn.com; internet:steven.leonard@nmp.cn.com; internet:wolniakd@nimo.com; Meena Khanna; Stephanie Coffin Date:

10/24/02 11:23AM

Subject:

NMP1 Conference Call: Stub Tube Rolling Who: Stephanie Coffin, Meena Khanna, Peter Tam (NRC)

Steve Leonard, et al. (Nine Mile Point)

When: 10/31/02 (Thursday), 2:00 p.m.

How: Call NRC bridge at 301-231-5539 or 1-800-638-8081. Listen to the complete greeting, then dial 2703#

What: See previous e-mail (reproduced below):

Items for Discussion with NMP in Regards to CRD Expansion Repairs

1. Discuss all of your rolled and rerolled repairs, i.e., to date, how many housings/stub tubes have been rolled and rerolled.
2. Verify that thirty-two of the thirty-three repaired housings at NMP-1have not leaked since repair in up to 18 years of service.
3. Discuss your last refueling outage inspection results of the subject CRD housings/stub tubes.
4. Discuss how the CRD roll repair is consistent with your Technical Specifications.
5. The staff only approved this alternative to the Code as a temporary fix. What do you consider temporary now that there is a permanent weld repair available?
6. With respect to the Code, what are your plans for performing a permanent weld repair?

Mail Envelope Properties (3DB8105D.4E6 : 10 : 20510)

Subject:

NMP1 Conference Call: Stub Tube Rolling Creation Date:

10/24/02 11:23AM From:

Peter Tam Created By:

PST@nrc.gov Recipients Action Date & Time nimo.com Transferred 10/24/02 11:23AM dosaj (INTernet:dosaj@nimo.com) wolniakd (internet:wolniakd@nimo.com)

iftikhar Transferred 10/24/02 11:23AM Abbasi (internet:iftikhar.Abbasi@nmp.cn.c steven Transferred 10/24/02 11:23AM leonard (internet:steven.leonard@nmp.cn.c nrc.gov owf2_po.OWFN_DO Delivered 10/24/02 11:23AM MKK (Meena Khanna)

Opened 10/24/02 12:57PM SMC1 (Stephanie Coffin)

Opened 10/24/02 04:44PM Post Office Delivered Route nimo.com INTernet iftikhar internet:nmp.cn.com steven internet:nmp.cn.com owf2_po.OWFN_DO 10/24/02 11:23AM nrc.gov Files Size Date & Time MESSAGE 2602 10/24/02 11:23AM Options Auto Delete:

No Expiration Date:

None Notify Recipients:

Yes Priority:

Standard Reply Requested:

No Return Notification:

Send Mail Receipt when Undeliverable Concealed

Subject:

No Security:

Standard To Be Delivered:

Immediate Status Tracking:

Delivered & Opened