Entergy Nuclear Vermont Yankee, LLC Entergy Nuclear Operations, Inc.

S Entergy 185 Old Ferry Road Brattleboro, VT 05302-0500 October 22, 2002 BVY 02-83 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555

Reference:

(a) Letter, Vermont Yankee to USNRC, "Request for Relief from the American Society of Mechanical Engineers Code for Repair of a Pin-Hole Leak in a Lube Oil Cooler," BVY 02-59, dated August 22, 2002

Subject:

Vermont Yankee Nuclear Power Station License No. DPR-28 (Docket No. 50-271)

Withdrawal of Request for Relief from the American Society of Mechanical Engineers Code for Repair of a Pin-Hole Leak in a Lube Oil Cooler In Reference (a) Vermont Yankee (VY) requested, pursuant to 10CFR50.55a(a)(3)(ii), to delay the repair of a minor pin-hole leak on the Service Water side of the "A" Emergency Diesel Generator (EDG) lube oil cooler until the 2002 refuel outage. VY has replaced the subject component and therefore relief from the code is no longer required. This letter serves to withdraw the request made via Reference (a).

We trust that this information is adequate; however, should you need additional information please contact Mr. Jim DeVincentis at (802) 258-4236.

Sincerely, Glautam Sen Manager, Licensing cc: USNRC Region I Administrator USNRC Resident Inspector - VYNPS USNRC Project Manager - VYNPS Vermont Department of Public Service _AoQ1j

SUMMARY

OF VERMONT YANKEE COMMITMENTS BVY NO.: 02-83 Withdrawal or Request for Relief from the American Society of Mechanical Enaineers Code for Repair of a Pin-Hole Leak in a Lube Oil Cooler The following table identifies commitments made in this document by Vermont Yankee.

Any other actions discussed in the submittal represent intended or planned actions by Vermont Yankee. They are described to the NRC for the NRC's information and are not regulatory commitments. Please notify the Licensing Manager of any questions regarding this document or any associated commitments.

COMMITMENT COMMITTED DATE

_ OR "OUTAGE" None N/A 1*

  • 1-

+

-t 4

VYAPF 0058.04 AP 0058 Rev. 1 Page 1 of I