Summary of 10/02/2002 Meeting on Severe Accident Management Alternatives to Support Review of License Renewal Application of H.B. Robinson Steam Electric Plant, Unit 2
ML022910114
Person / Time
Site: Robinson Duke Energy icon.png
Issue date: 10/11/2002
From: Emch R
Division of Regulatory Improvement Programs
To:
Emch, R L, NRR/DRIP/RLEP/415-1590
Shared Package
ML022910175 List:
References
Download: ML022910114 (8)


Text

October 11, 2002 APPLICANT: Carolina Power and Light Company FACILITY:

H. B. Robinson, Unit 2

SUBJECT:

SUMMARY

OF MEETING ON SEVERE ACCIDENT MANAGEMENT ALTERNATIVES TO SUPPORT REVIEW OF LICENSE RENEWAL APPLICATION OF H. B. ROBINSON STEAM ELECTRIC PLANT, UNIT 2 On October 2, 2002, staff conducted a meeting with Carolina Power and Light Company (CP&L) to discuss the Severe Accident Management Alternatives (SAMA) submittal made as part of the license renewal application for H. B. Robinson Steam Electric Plant, Unit 2 (Robinson). The meeting was conducted at the Robinson plant because the documentation for the plant risk and SAMA analyses are available there. Enclosure 1 is the list of attendees.

Staff opened the meeting by indicating that it wanted to concentrate on understanding:

1. The current Robinson risk profile and how it was developed and reviewed.
2. How the list of SAMAs was developed.
3. How external events were addressed.
4. How uncertainties were addressed.

CP&L agreed to provide probabilistic risk assessment (PRA) summary results based on the latest Robinson PRA. The staff asked about any efforts made by the applicant to identify SAMAs which might provide significant reductions in risk at a lower cost than the 270 SAMAs already evaluated in the Robinson submittal. The staff pointed out that SAMAs do not have to rely only on safety grade equipment. The staff indicated that information is needed about the three such potential SAMAS identified by the staff:

1. Automatic safety injection pump trip on low refueling water storage tank level to protect the pumps for being damaged if the tank empties before manual swap-over to recirculation can be implemented.
2. Portable battery chargers which could be used to recharge batteries in station blackout sequences (SBO).
3. A direct drive diesel-powered auxiliary feedwater pump that could provide another source of feedwater during SBO sequences.

2 Also, additional information and justification will be needed concerning the treatment of external events and the seal loss of coolant accident model used in the Robinson analysis. contains the documents given to the staff during the meeting.

/RA/

Richard L. Emch, Jr., Senior Project Manager Environmental Section License Renewal and Environmental Impacts Program Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket No. 50-261

Enclosures:

As Stated cc w/encls: See next page

2 Also, additional information and justification will be needed concerning the treatment of external events and the seal loss of coolant accident model used in the Robinson analysis. contains the documents given to the staff during the meeting.

/RA/

Richard L. Emch, Jr., Senior Project Manager Environmental Section License Renewal and Environmental Impacts Program Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket No. 50-261

Enclosures:

As Stated cc w/encls: See next page Accession Package no.:

1. Note to Applicant w/Encl. 1& 2: ML022910114
2. Changes made to MOR97 to Produce MOR99: ML022940141
3. H. B. Robinson Probabilistic Safety Assessment Peer Review Report, Draft Report, Dated December 31, 2001: ML022940150
4. Package: ML022910175 DISTRIBUTION:

PUBLIC P.T. Kuo RLEP R/F T. Narcizo S. K. Mitra J. Tappert M. Rubin R. Palla A. Fernandez R. Emch B. Bonser (RII)

D. Matthews/F. Gillespie R. Subbaratnam R. Hannah (RII)

RLEP/Environmental R/F

  • See previous concurrence DOCUMENT NAME: C:\\ORPCheckout\\FileNET\\ML022910114.wpd OFFICE RLEP:DRIP LA:RLEP:DRIP SC:RLEP:DRIP NAME REmch HBerilla JTappert DATE 10/10/02 10/09/02 10/11/02 OFFICIAL RECORD COPY

List of Attendees for SAMA Meeting on October 2, 2002, at the H. B. Robinson Plant Name Organization Talmage Clements CP&L Roger Stewart CP&L Jon Cudworth Tetra Tech NUS (CP&L Contractor)

Bruce Morgen CP&L Steven Laur CP&L Brad Dolan CP&L Rich Emch NRC Mark Rubin NRC Bob Palla NRC Jim Meyer ISL (NRC Contractor)

Jan Kozyra CP&L Don MacLeod Erin Engineering (CP&L Contractor)

Documents given to NRC during SAMA Meeting on October 2, 2002

1. List of changes made to MOR97 to produce MOR99 (most current Robinson PRA model)
2. Robinson Nuclear Plant Certification Summary (pages 1 & 2) dated 06/26/2002
3. Summary table indicating status of issues from Robinson Nuclear Plant PSA Peer Certification dated 09/02/2002
4. H. B. Robinson Probabilistic Safety Assessment Peer Review Report (Draft Report -

12/31/2001) (Cover Page, Pages 2-3, 4-1, 4-2, B-14, B-17, B-18, B-27, B-31, B-32, B-35, B-44 thru B-48, B-51 thru B-53, B-72, B-76 thru B-80, B-92 thru B-99, B-101 thru B-103, B-114, B-139 thru B-147, B-150, B-162, and B-168)

Mr. J. W. Moyer H. B. Robinson Steam Electric Carolina Power & Light Company Plant, Unit No. 2 cc:

Mr. William D. Johnson Vice President and Corporate Secretary Carolina Power & Light Company Post Office Box 1551 Raleigh, NC 27602 Ms. Karen E. Long Assistant Attorney General State of North Carolina Post Office Box 629 Raleigh, NC 27602 U.S. Nuclear Regulatory Commission Resident Inspectors Office H. B. Robinson Steam Electric Plant 2112 Old Camden Road Hartsville, SC 29550 Mr. T. P. Cleary Plant General Manager Carolina Power & Light Company H. B. Robinson Steam Electric Plant, Unit No. 2 3581 West Entrance Road Hartsville, SC 29550 Mr. Chris L. Burton Director of Site Operations Carolina Power & Light Company H. B. Robinson Steam Electric Plant, Unit No. 2 3581 West Entrance Road Hartsville, SC 29550 Public Service Commission Post Office Drawer 11649 State of South Carolina Columbia, SC 29211 Mr. C. T. Baucom Supervisor, Licensing/Regulatory Programs Carolina Power & Light Company H. B. Robinson Steam Electric Plant Unit No. 2 3581 West Entrance Road Hartsville, SC 29550 Ms. Beverly Hall, Acting Director N.C. Department of Environment and Natural Resources Division of Radiation Protection 3825 Barrett Dr.

Raleigh, NC 27609-7721 Mr. Robert P. Gruber Executive Director Public Staff - NCUC 4326 Mail Service Center Raleigh, NC 27699-4326 Mr. Virgil R. Autry, Director South Carolina Department of Health Bureau of Land & Waste Management Division of Radioactive Waste 2600 Bull Street Columbia, SC 29201 Mr. Terry C. Morton, Manager Performance Evaluation and Regulatory Affairs CPB 7 Carolina Power & Light Company Post Office Box 1551 Raleigh, NC 27602-1551 Mr. John H. ONeill, Jr.

Shaw, Pittman, Potts & Trowbridge 2300 N Street, NW.

Washington, DC 20037-1128 Mr. B. L. Fletcher III Manager - Regulatory Affairs Carolina Power & Light Company H. B. Robinson Steam Electric Plant Unit No. 2 3581 West Entrance Road Hartsville, SC 29550-0790 Mr. Alan P. Nelson Nuclear Energy Institute 1776 I Street, NW., Suite 400 Washington, DC 20006-3708 Talmage B. Clements Manager - License Renewal Carolina Power and Light Company 410 South Wilmington Street Raleigh, NC 27602 Mr. Roger A. Stewart Carolina Power and Light Company H. B. Robinson Steam Electric Plant, Unit No. 2 3581 West Entrance Road Hartsville, SC 29550