| Site: | Hatch, Dresden, Peach Bottom, Browns Ferry, Nine Mile Point, Fermi, Hope Creek, Susquehanna, Columbia, Brunswick, Limerick, Clinton, Quad Cities, LaSalle (DPR-019, DPR-025, DPR-029, DPR-030, DPR-033, DPR-044, DPR-052, DPR-056, DPR-057, DPR-062, DPR-068, DPR-071, NPF-005, NPF-011, NPF-014, NPF-018, NPF-021, NPF-022, NPF-037, NPF-039, NPF-043, NPF-057, NPF-062, NPF-066, NPF-069, NPF-085) |
| Issue date: | 10/01/2002 |
| From: | Post J General Electric Co |
| To: | Burgess S, Bill Dean, Eselgroth P, Henson J, Hodge C, Kennedy K Office of Nuclear Reactor Regulation, NRC Region 1, NRC/RGN-II, NRC/RGN-III, NRC Region 4 |
| References | |
| 02-07NRC.DOC, MFN 02-063 | |
| Download: ML022830278 (8) | |
Text
U.S. Nuclear Regulatory Commission Operations Center Event Report General Information or Other (PAR)
Event #
39236 Rep Org: GENERAL ELECTRIC COMPANY Notification Date /Time: 10/01/2002 20:24 (EDT)
Supplier: GENERAL ELECTRIC COMPANY Event Date/ Time: 16101/2002 (PDT)
Last Modification: 10/01/2002 Region: 4 Docket #:
City: San Jose Agreement State: Yes County:
License #:
State: CA NRC Notified by: JASON S. POST Notifications: PETE ESELGROTH RI HQ Ops Officer: MIKE NORRIS JAY HENSON R2 Emergency Class: NON EMERGENCY SONIA BURGESS R3 10 CFR Section:
KRISS KENNEDY R4 21.21 UNSPECIFIED PARAGRAPH WILLIAM DEAN NRR VERN HODGE NRR PART 21.21 REPORT INVOLVING STABILITY OPTION III
Subject:
Stability Option II: Possible Successive Confirmation Count Resets "This letter provides notification of a 60 Day Interim Report per § 21.21 (a)(2) for plants that have selected stability long-term solution Option Ill. The basis for this notification is that GE Nuclear Energy (GE) has not completed the evaluation of a potential problem with the algorithm that provides the licensing basis Minimum Critical Power Ratio (MCPR) Safety Limit protection for stability Option III. The algorithm determines Successive Confirmation Count (SCC) of an oscillating power signal. A reactor trip is generated when SCC and oscillation amplitude reach their trip setpoints in accordance with the Option III and reactor protection system configuration. The concern is that the oscillation period could change for an oscillation that initiates while reactor state conditions are changing rapidly (e.g., during a two-recirculation pump trip event) and cause the SCC to reset, thus delaying the reactor scram.
"GE believes that there is low potential for the MCPR Safety Limit to be violated as a result of this concern.
However, a 60 Day Interim Report is required since the evaluation has not been completed. Further information is provided in the attached notification.
"(ii) Identification of the facility, the activity, or the basic component supplied for such facility or such activity within the United States which fails to comply or contains a defect:
"The affected basic component is the Period Based Detection Algorithm (PBDA) of stability long-term solution Option III. The PEDA provides the licensing basis MCPR Safety Limit protection for anticipated coupled thermal hydraulic-neutronic reactor,instabilities. The concern is that the Successive Confirmation Count (SCC) could reset if an oscillation develops while reactor state conditions are changing rapidly (e.g., during a two recirculation pump trip event) and delay a reactor scram beyond that assumed in the licensing basis analysis. The algorithm is more susceptible to SCC resets with a period tolerance th'it is near to the minimum allowed by licensing documents (e.g., 50 msec). SCC resets are less likely with higher period tolerance values (e.g., 100 to 300 msec).
1010112002 Page I
U.S. Nuclear Regulatory Commission Operations Center Event Report General Information or Other (PAR)
Event#
39236
"(iii) Identification of the firm constructing the facility or supplying the basic component which fails to comply or contains a defect:
"GE Nuclear Energy, San Jose, California
"(iv) Nature of the defect or failure to comply and safety hazard which is created or could be created by such defect or failure to comply:.
"A reactor scram is only initiated by the PBDA when the SCC exceeds the count setpoint and the oscillation amplitude exceeds the amplitude setpoint The licensing basis is that the SCC will exceed the count setpoint before the amplitude reaches the amplitude setpoint. If the SCC resets, then the amplitude could exceed the amplitude setpoint before SCC reaches the count setpoint. This could lead to violation of the MCPR Safety Limit.
"If scram is delayed, boiling transition could be experienced on a portion of some fuel bundles. This would be a violation of a Technical Specification Safety Limit and is reportable under 10 CFR 21. However, it would not produce a significant safety hazard or threat to public health and safety.
"(v) The date on which the information of such defect or failure to comply was obtained:
"(vi) In the case of a basic component which contains a defect or failure to comply, the number and locations of all such components in use at, supplied for, or being supplied for one or more facilities or activities subject to the regulations in this part:
"A defect has not been confirmed to exist. The potentially affected plants are listed in Attachment 2.
"(vii) The corrective action which has been, is being, or will be taken; the name of the individual or organization responsible for the action; and the length of time that has been or will be taken to complete the action (note, these are actions specifically associated with the identified Reportable Condition):
"GE has communicated this concern to the BWR Owners' Group Potential Issues Resolution Team (PIRT) and to the Stability Detect & Suppress Committee.
"GE is continuing to evaluate the potential for the SCC to be reset for current licensed reactor operating conditions.
This effort will be completed by November 18, 2002.
'(viii) Any advice related to the defect or failure to comply about the facility, activity, or basic component that has been, is being, or will be given to purchasers or licensees:
"It is recommended that potentially affected licensees keep informed through the BWR Owners' Group. No specific plant actions are recommended at this time.'
Plants listed on Attachment 2 Clinton, Brunswick 1 & 2, Nine Mile Point 2, Fermi 2, Columbia, Dresden 2 & 3, LaSalle 1 & 2, Limerick 1 & 2, Peach Bottom 2 & 3, Quad Cities 1 & 2, Perry 1, Susquehanna 1 & 2, Hope Creek, Hatch 1 & 2, and Browns Ferry 1, 2 & 3.
1010112002 Page 2
OCT 81'2*7'02 05: 1GPM GE NUCLERR ENERGY P. 1/5 GE Nuclear Energy General Electric Company 175 Curt'r Ave. San Jose. CA 95125 October 1, 2002 02-07NRC.DOC MFN 02-063 Document Control Desk United States Nuclear Regulatory Commission One White Flint North 11555 Rockville Pike Rockville, Maryland 20852-2738
Subject:
Stability Option III: Possible Successive Confirmation Count Resets This letterprovides notification of a 60 Day Interim Report per §21.21(a)(2) for plants that have selected stability long-term solution Option Ill. The basis for this notification is that GE Nuclear Energy (GE) has not completed the evaluation of a potential problem with the algorithm that provides the licensing basis Minimum Critical Power Ratio (MlCPR) Safety Limit protection for stability Option M. The algorithm determines Successive Confirmation Count (SCC) of an oscillating power signal. A reactor trip is generated when SCC and oscillation amplitude reach their trip setpoints in accordance with the Option III and reactor protection system configuration. The concern is that the oscillation period could change for an oscillation that initiates while reactor state conditions are changing rapidly (e.g., during a two-recirculation pump trip event) and cause the SCC to reset, thus delaying the reactor scram.
GE believes that there is low potential for the MCPR Safety Limit to be violated as a result of this concern. However, a 60 Day Interim Report is required since the evaluation has not been completed. Further information is provided in the attached notification.
If you have any questions, please call me at (408) 925-5362.
Sincerely, Jason. S. Post, Manager Engineering Quality and Safety Evaluations
OCT 01 '02 05:17PM GE NUCLEPR ENERGY October 1, 2002 02-07NRC.DOC MFN 02-063 cc: S. D. Alexander (NRC-NRR/DISP/PSIB) Mail Stop 6 F2 G. C. Cwalina (NRC-NRR/DISP/PSIB) Mail Stop 6 F2 J. F. Klapproth (GE-NE)
H. 3. Neems (GE-NE)
PRC File Attachments:
- 1. 60 Day Interim Report per §21.21(a)(2)
- 2. Potentially Affected Plants 2
P. 2/5
OCT 01 'O0 05:17PM GE NUCLEAR ENERGY P. 3/5 October 1, 2002 02-07NRC.DOC MFN 02-063 - 60 Day Interim Report per §21.21 (a)(2)
(i)
Name and address of the individual informing the Commission:
Jason S. Post, Manager, Engineering Quality & Safety Evaluation, GE Nuclear Energy, 175 Curtner Avenue, San Jose, CA 95125 (ii)
Identification of the facility, the activity, or the basic component supplied for such facility or such activity within the United States which fails to comply or contains a defect:
The affected basic component is the Period Based Detection Algorithm (PBDA) of stability long-term solution Option MII. The PBDA provides the licensing basis MCPR Safety Limit protection for anticipated coupled thermal hydraulic-neutronic reactor instabilities. The concern is that the Successive Confirmation Count (SCC) could reset if an oscillation develops while reactor state conditions are changing rapidly (e.g., during a two recirculation pump trip event) and delay a reactor scram beyond that assumed in the licensing basis analysis. The algorithm is more susceptible to SCC resets with a period tolerance that is near to the minimum allowed by licensing documents (e.g., 50 msec). SCC resets are less likely with higher period tolerance values (e.g., 100 to 300 msec).
(iii)
Identification of the firm constructing the facility or supplying the basic component which fails to comply or contains a defect:
GE Nuclear Energy, San Jose, California (iv)
Nature of the defect or failure to comply and safety hazard which is created or could be created by such defect or failure to comply:
A reactor scram is only initiated by the PBDA when the SCO exceeds the count setpoint and the oscillation amplitude exceeds the amplitude setpoint.
The licensing basis is that the SCC will exceed the count setpoint before the amplitude reaches the amplitude setpoint. If the SCC resets, then the amplitude could exceed the amplitude setpoint before SCC reaches the count setpoint. This could lead to violation of the MCPR Safety Limit.
If scram is delayed, boiling transition could be experienced on a portion of some fuel bundles. This would be a violation of a Technical Specification Safety Limit and is reportable under 10CM1L2.
However, it would not produce a significant safety hazard or threat to public health and safety.
(v)
The date on which the information of such defect or failure to comply was obtained:
August 2, 2002 3
OCT 01 '02 05:17PM GE NUCLEAR ENERGY P.415 October 1, 2002 02-07NRC.DOC MFN 02-063 (vi)
In the case of a basic c6mponent which contains a defect or failure to comply, the number and locations of all such components in use at, supplied for, or being supplied for one or more facilities or activities subject to the regulations in this part:
A defect has not been confirmed to exist. The potentially affected plants are listed in Attachment 2.
(vii)
The corrective action which has been, is being, or will be taken; the name of the individual or organization responsible for the action; and the length of time that has been or will be taken to complete the action (note, these are actions specifically associated with the identified Reportable Condition):
GE has communicated this concern to the BWR Owners' Group Potential Issues Resolution Team (PIRT) and to the Stability Detect & Suppress Committee.
GE is continuing to evaluate the potential for the SCC to be reset for current licensed reactor operating conditions. This effort will be completed by November 18,2002.
(viii)
Any advice related to the defect or failure to comply about the facility, activity, or basic component that has been, is being, or will be given to purchasers or licensees:
It is recommended that potentially affected licensees keep informed through the BWR Owners' Group. No specific plant actions are recommended at this time.
4
OCT 01 '02 05:17PM GE NUCLEAR ENERGY P.5/5 October 1, 2002 02-07NRC.DOC MFN 02-063 - Potentially Affected Plants x
x x
x x x
x x
x x x x x x
x x x x
x x x
x x x x
me neitC AmerGen Energy Co.
AmerGen Energy Co.
Carolina Power & Light Co.
Carolina Power & Light Co.
Constellation Nuclear Constellation Nuclear.
Detroit Edison Co.
Dominion Generation Energy Northwest Entergy Nuclear Northeast Entergy Nuclear Northeast Entergy Operations, Inc.
Entergy Operations, Inc.
Entergy Nuclear Northeast Exelon Generation Co.
Exelon Generation Co.
Exelon Generation Co.
Exelon Generation Co.
Exelon Generation Co.
Exelon Generation Co.
Exelon Generation Co.
Exelon Generation Co.
Exelou Generation Co.
Exelon Generation Co.
Exelon Generation Co.
FirstEnergy Nuclear Operating Co.
Nebraska Public Power District Nuclear Management Co.
Nuclear Management Co.
Pooled Equipment Inventory Co.
PPL Susquehanna LLC Public Service Electric & Gas Co.
Southern Nuclear Operating Co.
Southern Nuclear Operating Co.
Tennessee Valley Authority Tennessee Valley Authority Tennessee Valley Authority 5
Clinton Oyster Creek Bnmswick I Bnmswick 2 Nine Mile Point 1 Nine Mile Point 2 Fermi 2 Millstone 1 Columbia FitzPatrick Pilgrim Grand Gulf River B end Vermont Yankee CRIT Facility Dresden 2 Dresden 3 LaSalle 1 LaSalle 2 Limerick 1 Limerick 2 Peach Bottom 2 Peach Bottom 3 Quad Cities I Quad Cities 2 Perry 1 Cooper Duane Arnold Monticello P1M Susquehanna 1 Susquehanna 2 Hope Creek Hatch 1 Hatch 2 Browns Ferry 1 Browns Ferzy 2 Browns Ferry 3
OCT 01 '02 05:17PM GE NUCLEAR ENERGY October 1, 2002 02-07NRC.DOC IFN 02-063 - Potentially Affected Plants x
x x
x x
x x
x x
x x
x x
x x x
x x x x
x x x x x
Utility AmerGen Energy Co.
ArnerGen Energy Co.
Carolina Power & Light Co.
Carolina Power & Light Co.
Constellation Nuclear Constellation Nuclear.
Detroit Edison Co.
Dominion Generation Energy Northwest Entergy Nuclear Northeast Entergy Nuclear Northeast Entergy Operations, Inc.
Entergy Operations, Inc.
Entergy Nuclear Northeast Exclon Generation Co.
Exelon Generation Co.
Exelon Generation Co.
Exelon Generation Co.
Exelon Generation Co.
Exelon Generation Co.
Exelon Generation Co.
Exelon Generation Co.
Exelon Generation Co.
Exelon Generation Co.
Exelon Generation Co.
FirstEnergy Nuclear Operating Co.
Nebraska Public Power District Nuclear Management Co.
Nuclear Management Co.
Pooled Equipment Inventory Co.
PPL Susquehanna LLC Public Service Electric & Gas Co.
Southern Nuclear Operating Co.
Southern Nuclear Operating Co.
Tennessee Valley Authority Tennessee Valley Authority Tennessee Valley Authority 5
P. 5/5 Clinton Oyster Creek Brunswick I Brunswick 2 Nine Mile Point I Nine Mile Point 2 Fermi 2 Millstone I Columbia FitzPatrick Pilgrim Grand Gulf River Bend Vermont Yankee CRIT Facility Dresden 2 Dresden 3 LaSalle 1 LaSalle 2 Limerick 1 Limerick 2 Peach Bottom 2 Peach Bottom 3 Quad Cities I Quad Cities 2 Perry 1 Cooper Duane Arnold Monticello PIM Susquehanna 1 Susquehanna 2 Hope Creek Hatch I Hatch 2 Browns Ferry I Browns Ferry 2 Browns Ferry 3