Certificate of Compliance (CoC) No. 9196, Revision No. 19, (Model No. UX-30 Package) (Docket 71-9196) (TAC L23378)
ML022700346
Person / Time
Site: 07109196
Issue date: 09/26/2002
From: Brach E
NRC/NMSS/SFPO
To: Paquin P
Chem-Nuclear Systems
Tiktinsky D NRC/NMSS 301 415 8523
Shared Package
ML022700350 List:
References
-RFPFR, L23378
Download: ML022700346 (2)


Text

NRC FORM 618 (8-2000) 10 CFR 71 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES 1.

a. CERTIFICATE NUMBER
b. REVISION NUMBER
c. DOCKET NUMBER
d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9196 19 71-9196 USA/9196/AF-85 1

OF 3

2.

PREAMBLE

a. This certificate is issued to certify that the package (packaging and contents) described in Item 5 below meets the applicable safety standards set forth in Title 10, Code of Federal Regulations, Part 71, Packaging and Transportation of Radioactive Material.
b. This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported.

3.

THIS CERTIFICATE IS ISSUED ON THE BASIS OF A SAFETY ANALYSIS REPORT OF THE PACKAGE DESIGN OR APPLICATION

a. ISSUED TO (Name and Address)
b. TITLE AND IDENTIFICATION OF REPORT OR APPLICATION Duratek 140 Stoneridge Drive Columbia, South Carolina 29210 Chem-Nuclear Systems, LLC application dated February 17, 1999, as supplemented.
4. CONDITIONS This certificate is conditional upon fulfilling the requirements of 10 CFR Part 71, as applicable, and the conditions specified below.

5.

(a)

Packaging (1)

Model No.:

UX-30 (2)

Description Overpack for 30-inch enriched uranium hexafluoride (UF6) cylinders. The overpack is a right circular cylinder constructed of two stainless steel shells with the volume between the shells filled with 6-inch thick foam (7.8 - 9.8 PCF). A stepped and gasketed horizontal joint permits the top half of the overpack to be removed from the base. The package "halves" are secured with ten indexed, cross-locking "ball lock" pins. The overpack is 43.5" in diameter by 96" long. The maximum gross weight of the package is 8270 lbs.

Two types of 30 inch uranium hexafluoride cylinders may be carried in the UX-30 overpack.

These are (1) an ANSI N14.1 Standard 30B cylinder, or (2) a CBC Watertight' Model 195 cylinder.

The CBC Watertight' Model 195 cylinder is essentially a 30B cylinder equipped with a Valve Protective Cover (VPC) that bolts over and protects the cylinder valve during transport.

The VPC is a special design feature that provides additional assurance against the inleakage of water to the containment system and is an enclosure that retains any leakage.

NRC FORM 618 (8-2000) 10 CFR 71 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES 1.

a. CERTIFICATE NUMBER
b. REVISION NUMBER
c. DOCKET NUMBER
d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9196 19 71-9196 USA/9196/AF-85 2

OF 3

(3)

Drawings The Model No. UX-30 packaging is fabricated in accordance with Chem-Nuclear Systems LLC, Drawing No. C-110-B-57922-0002, Sheets 1 through 3, Rev. 2. The CBC Watertight' Model 195 Cylinder is fabricated in accordance with Columbiana Boiler Company drawings:

71800-C, Rev. 2, SK-71800-B-3, Rev. 1, SK-71800-B-4, Rev. 1, SK-71800-5, Rev. 0 and SK-71800-B-7, Rev. 0.

(b)

Contents (1)

Type and form of material UF6 enriched in the U-235 isotope.

(2)

Maximum quantity of material per package (i)

ANSI standard N14.1 30B cylinder or CBC Watertight' Model 195 cylinder: 5,020 pounds UF6 enriched to not more than 5 w/o in the U-235 isotope. The maximum H/U atomic ratio for the UF6 is 0.088.

(c)

Transport Index for Criticality Control (Criticality Safety Index)

Minimum criticality safety index for the UX-30 overpack containing a standard ANSI N14.1 30B cylinder 5.0 Minimum criticality safety index to be shown on the label for the UX-30 overpack containing a CBC Watertight' Model 195 Cylinder 0.0 6.

The ANSI standard 30B, 30-inch diameter UF6 cylinder, must be fabricated, inspected, tested and maintained in accordance with a) American National Standard N14.1-1995 or an earlier version of ANSI N14.1 in effect at the time of fabrication or b) American National Standard N14.1-1995 or an earlier version of ANSI N14.1 in effect at the time of fabrication and ISO 7195:1993(F). Cylinders must be fabricated in accordance with Section VIII, Division I, of the ASME (American Society of Mechanical Engineers) Boiler and Pressure Vessel Code and be ASME Code stamped.

7.

The CBC Watertight' Model 195 cylinder (new or retrofitted cylinders) must be fabricated, inspected, tested, and maintained in accordance with CBC Watertight' Model 195 cylinder specification no. CBC-WT-M195, Revision 2 dated April 5, 2002.

8.

When the optional 4 lid lifting clips are used instead of the top lugs, the top lid (cover) must be lifted with a spreader bar (saddle).

9.

In addition to the requirements of Subpart G of 10 CFR Part 71:

(a)

Prior to each shipment, the overpack gaskets must be inspected. These gaskets must be replaced if inspection shows any defects or every 12 months, whichever occurs first.

NRC FORM 618 (8-2000) 10 CFR 71 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES 1.

a. CERTIFICATE NUMBER
b. REVISION NUMBER
c. DOCKET NUMBER
d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9196 19 71-9196 USA/9196/AF-85 3

OF 3

(b)

Each packaging must meet the Acceptance Tests and Maintenance Program of Chapter 8 of the application, as supplemented.

(c)

The package shall be prepared for shipment and operated in accordance with the Operating Procedures of Chapter 7 of the application, as supplemented.

(d)

Prior to each shipment, the stainless steel components of the packaging must be visually inspected. Packagings in which stainless steel components show pitting, corrosion, cracking, or pinholes are not authorized for transport.

10.

The 30-inch diameter UF6 cylinder valve stem and plug may be tinned with ASTM B32, alloy 50A or Sn50 solder material, or a mixture of alloy 50A or Sn50 with alloy 40A or Sn40A material, provided the mixture has a minimum tin content of 45 percent.

11.

The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 71.12.

12.

Expiration date: February 28, 2006.

REFERENCES Chem-Nuclear Systems, LLC application dated February 17, 1999.

United States Enrichment Corporation supplement dated April 14, 1997. Chem-Nuclear Systems, LLC supplements dated May 10, 1999, April 14, June 22, October 31, and December 4, 2000, April 23, October 11, and October 19, 2001 and April 16, 2002.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION

/RA/ original signed by C Miller for /s/

E. William Brach, Director Spent Fuel Project Office Office of Nuclear Material Safety and Safeguards Date: September 26, 2002