ML022630118

From kanterella
Jump to navigation Jump to search
NRC Administrative Topics Questions: Control Room Evacuation Due to Fire
ML022630118
Person / Time
Site: Summer 
Issue date: 09/16/2002
From:
NRC/RGN-II
To:
References
FOIA/PA-2002-0371
Download: ML022630118 (5)


Text

V. C. SUMMER NUCLEAR STATION NRC ADMINISTRATIVE TOPICS QUESTIONS CONTROL ROOM EVACUATION DUE TO FIRE Revision 0

Student Handout Sheet QUESTION 1 You are the NROATC. The Shift Supervisor has just directed evacuation of the control room due to a fire. There is thick smoke in the control room with visibility of less than two feet. What are your immediate actions?

Which station procedure directs the immediate actions for this event?

RETURN THIS SHEET TO YOUR EVALUATOR WHEN YOU FEEL THAT YOU HAVE SATISFACTORILY COMPLETED THE ASSIGNED TASK

QUESTION 1 You are the NROATC. The Shift Supervisor has just directed evacuation of the control room due to a fire. There is thick smoke in the control room with visibility of less than two feet. What are your immediate actions?

Which station procedure directs the immediate actions for this event?

ANSWER 1 Manually trip the reactor from the main control board Ensure the main turbine trips Trip all reactor coolant pumps FEP-4.0 directs the immediate actions for this event

Student Handout Sheet QUESTION 2 Following a control room evacuation due to a fire in the control room, where do the on-shift personnel report for their first duty following the evacuation of the control room?

Control Room Supervisor NROATC BOP IB Operator AB Upper Level Shift Engineer RETURN THIS SHEET TO YOUR EVALUATOR WHEN YOU FEEL THAT YOU HAVE SATISFACTORILY COMPLETED THE ASSIGNED TASK

QUESTION 2 Following a control room evacuation due to a fire in the control room, where do the on-shift personnel report for their first duty following the evacuation of the control room?

ANSWER 2

"* Control Room Supervisor reports to the CREP

"* NROATC reports to the XSW1DB switchgear room

"* BOP reports to the XSW1DA switchgear room 1B Operator reports to the "B" Diesel Generator room AB Upper Level Operator secures any release in progress on AB-412 hallway Shift Engineer reports to the CREP

  • Denotes required knowledge