ML022530234
| ML022530234 | |
| Person / Time | |
|---|---|
| Site: | Fermi |
| Issue date: | 09/05/2002 |
| From: | Kim T NRC/NRR/DLPM/LPD3 |
| To: | O'Connor W Detroit Edison |
| References | |
| TAC MB5169 | |
| Download: ML022530234 (2) | |
Text
Programs and Manuals 5.5 5.5 Programs and Manuals 5.5.1
- a.
Preventive maintenance.and periodic visual requirements; and
- b.
Integrated leak test requirements for refueling cycle intervals or less.
inspection each system at Not Used (continued)
Amendment No. #/.
150 FERMI - UNIT 2 Offsite Dose Calculation Manual (ODCM)
(continued)
- 3.
Shall be submitted to the NRC in the form of a complete, legible copy of the entire ODCM as a part of or concurrent with the Radioactive Effluent Release Report for the period of the report in which any change in the ODCM was made.
Each change shall be identified by markings in the margin of the affected pages, clearly indicating the area of the page that was changed, and shall indicate the date (i.e..
month and year) the change was implemented.
Primary Coolant Sources Outside Containment This program provides controls to minimize leakage from those portions of systems outside containment that could contain highly radioactive fluids during a serious transient or accident to levels as low as practicable.
The systems include Core Spray, High Pressure Coolant Injection, Residual Heat Removal, Reactor Core Isolation Cooling, reactor water sampling, Post Accident Sampling, reactor water cleanup, Hydrogen Recombiners, Primary Containment Monitoring, control rod drive discharge headers, and Standby Gas Treatment.
The program shall include the following:
5.5.2 5.5.3 5.0-8
Programs and Manuals 5.5 5.5 Programs and Manuals 5.5.4 Radioactive Effluent Controls Program This program conforms to 10 CFR 50.36a for the control of radioactive effluents and for maintaining the doses to members of the public from radioactive effluents as low as reasonably achievable.
The program shall be contained in the ODCM, shall be implemented by procedures, and shall include remedial actions to be taken whenever the program limits are exceeded.
The program shall include the following elements:
- a.
Limitations on the functional capability of radioactive liquid and gaseous monitoring instrumentation including surveillance tests and setpoint determination in accordance with the methodology in the ODCM;
- b.
Limitations on the concentrations of radioactive material released in liquid effluents to unrestricted areas, conforming to ten times the concentration values in 10 CFR 20.1001 - 20.2402, Appendix B, Table 2, Column 2;
- c.
Monitoring, sampling, and analysis of radioactive liquid and gaseous effluents in accordance with 10 CFR 20.1302 and with the methodology and parameters in the ODCM;
- d.
Limitations on the annual and quarterly doses or dose commitment to a member of the public from radioactive materials in liquid effluents released to unrestricted areas, conforming to 10 CFR 50, Appendix I;
- e.
Determination of cumulative and projected dose contributions from radioactive effluents for the current calendar quarter and current calendar year in accordance with the methodology and parameters in the ODCM at least every 31 days; (continued)
Amendment No.#/*z, 150 5.0-9 FERMI -UNIT 2