.4 NUCLEAR REACTOR LABORATORY AN INTERDEPARTMENTAL CENTER OF MASSACHUSETTS INSTITUTE OF TECHNOLOGY JOHN A. BERNARD Director Director of Reactor Operations Pnncipal Research Engineer 138 Albany Street, Cambridge, MA 02139-4296 Telefax No (617)253-7300 Telephone No (617) 253-4202 Activation Analysis Coolant Chemistry Nuclear Medicine Reactor Engineering 22 August 2002 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20555

Subject:

License Amendment for MIT Research Reactor, License No. R-37, Docket No. 50-20, "Technical Specification No. 6.7 - Experiments Involving In-Core Irradiation of Fissile Materials"

Dear Sir or Madam:

On November 21, 2001, the Massachusetts Institute of Technology submitted the above referenced license amendment. That request has now been reviewed following discussion comments, and we believe that the amendment can be improved by further specifying more of the planned safety aspects.

Accordingly, the amendment request submitted as of November 21, 2001, is hereby withdrawn and the enclosed request is submitted.

Please contact either of the undersigned should further information be required.

Sincerely, Lin-Wen Hu, Ph.D.

Utilization Engineer A. Bernard, Ph.D Director I declare under penalty of perjury tJ t the foregoing is true and correct.

Executed

- 2.-o3 o,

' (A-L, Date Signature cc:

USNRC USNRC C)

Senior Project Manager NRR/ONDD Region 1 - Project Scientist, Effluents Radiation Protection Section (ERPS)

Safety Review #-0-01-1 1 A.

TS #6.1.7 "Radioactive Releases" The current wording of TS #6.1.7 (b) is overly conservative. It states that "the total radioactive materials inventory of an experiment or credibly coupled experiments shall be limited such that the dose in unrestricted areas resulting from release of this inventory at its calculated maximum value shall not exceed that of the Design Basis Accident." In reality, release of radioactive materials is limited by both the initiating event and its associated release path. The current wording implies the assumption that the maximum radioactive inventory is released regardless of the initiating event and its release path.

The proposed wording for the revised TS #6.1.7 is attached. The new wording sets the limit of offsite dose resulting from an experiment malfunction to be that of the 10 CFR 20.

B.

TS #6.7 "Experiments Involving In-Core Irradiation of Fissile Materials"

1.

Description of Change The MITR currently does not have a technical specification (TS) for in-core irradiation of fissile materials. The purpose of the proposed TS amendment is to provide general requirements for in-core irradiation of fissile materials. Each new type of fissile material irradiation experiment will be analyzed and reviewed/approved individually by the MIT Reactor Safeguards Committee (MITRSC) because the reactivity effects, heat transfer characteristics, etc., can vary significantly depending on the type of fissile material, its enrichment, and its geometry.

SR#-0-01-11 OCT 03 2001

2.

Limitations on In-Core Irradiation of Fissile Materials for Research Reactors The MITR is licensed as a research reactor. The limitations on in-core irradiation of fissile materials for research reactors are imposed by the definition of a research reactor.

Code of Federal Regulations 10 Part 50.2 defines a non-power reactor as a research or test reactor licensed under 10 CFR 50.21(c) or 50.22 for research and development. A test facility is defined in 10 CFR 50.2 as a nuclear reactor for which "...an application has been filed for a license authorizing operation at: (1) a thermal power level in excess of 10 megawatts; or (2) a thermal power level in excess of 1 megawatt, if the reactor is to contain: (i) a circulating loop through the core in which the applicant proposes to conduct fuel experiments; or (ii) a liquid fuel loading; or (iii) an experimental facility in the core in excess of 16 square inches in cross-section." Therefore, it is possible to irradiate fissile materials in the MITR core if the conditions of provisions 10 CFR 50.2(2) (i) through (iii) are avoided.

3.

Other Limits Specific to MITR Other limits on the in-core irradiation of fissile materials specific to the MITR in core experiments are experiment reactivity worth limit and onset of nucleate boiling (ONB). Additional requirements such as weekly sampling of cover gas in the void space and over-temperature automatic reactor scram provide redundant protection against a potential malfunction of the fissile materials irradiation experiments. The limit on U-235 content in a fissile materials irradiation experiment is derived from the Design Basis Accident (DBA) of the reactor. The effect of actinides, which are produced from U-238, on off-site dose is analyzed. It is concluded that a limit on the initial amount of U-238 is not required.

SR#-0-01-11 OCT 03 2001 3.1 Off-Site Dose during DBA The Design Basis Accident (DBA) chosen for the MITR-II assumes a blockage of five coolant flow channels that results in four fuel plates completely melted. (Note: It is highly unlikely that a large piece of foreign material would block the coolant channels completely because it would have to have fallen through the upper grid hold down mechanism when a fuel element was removed.) Release of the fission products to the atmosphere was calculated assuming the fission product buildup achieved saturation Off site dose to the general public was then calculated from the released fission products. The maximum amount of fissile materials that can be accommodated in a fissile material experiment should result in a maximum fission product release below that of the DBA.

Hence the scope of the SAR is not altered by the in-core fissile material irradiation. Using a simple approximation based on the U-235 content, the maximum amount of U-235 would be 506 grams (mass of U-235 per element) x 4 (plates) / 15 (plates per element) =

135 grams. A limit of the total initial amount of 100 grams U-235 is conservatively chosen.

The off-site whole body dose resulting from actinides is calculated. Details of the calculation are included in the attached memo. Actinides are produced when U-238 is irradiated. The off-site whole body dose from actinides is calculated to be 2 mrem per kilogram of initial U-238. The maximum initial amount of U-238, which is set by the total off-site dose from both fission product and actinide releases of the fission materials experiment, is calculated to be 31 kilograms. This amount is significantly higher than that of natural uranium that contains 100 grams of U-235, 0.1 kgU-235x(O.993/0.007)=

14.2 kgU-238. Therefore, a limit on the initial amount ofU-238 is not required.

Simultaneous occurrence of the DBA and failure of an in-core fissile material experiment are not considered credible because coolant channel blockage of both a fissile material experiment and a fuel element is extremely unlikely.

SR#-0-01-1 1 OCT 03 2001 3.2 Reactivity Effect TS #6 1 "General Experiment Criteria" limits the maximum reactivity worth of a secured experiment to 1.8% AK/K (or 2.3 beta).

It was previously calculated that addition of one gram of U-235 (93% enriched) in the A-ring would result in a positive reactivity insertion of 8.29 mbeta, which was obtained in refueling calculations Therefore, the maximum amount of U-235 that can be added in the A-ring would be 2300 mbeta / 8.29 mbeta/gram = 277 grams of U-235. Since the reactivity effect could vary significantly by the type of material, geometry etc., each type of fissile material irradiation should be analyzed and reviewed.

3.3 Onset of Nucleate Boiling The limit on the thermal power generated from a fissile material experiment is primarily imposed by the onset of nucleate boiling (ONB) which is one of the criteria in TS 46.1 "General Experiment Criteria".

Each fissile material irradiation experiment facility design will be analyzed and reviewed to ensure that ONB would not occur during steady-state operation However, 200 kW, which is the average thermal power per element, is used to set an upper bound for any fissile material irradiation experiment.

3.4 Over-Temperature Automatic Scram The inner barrier of the double encapsulation is monitored for over-temperature.

The scram setpoint is experiment-dependent and will be chosen to avoid rapid mechanical and/or chemical degradation of the barrier. The scram setpoint will be documented in the safety review that is required by for each in-core fissile materials irradiation experiment.

4.

Off-Site Dose Calculations for Fission Product Gases Release Fission product gas release is an unlikely accident scenario because:

SR#-0-01-11 OCT 03 2001 a)

As shown in Section 3, the proposed technical specification requires weekly sampling of cover gas of a fissile materials irradiation experiment when the reactor power is at 100 kW or higher. This will detect any potential leakage of fission product gases from the barriers of a fissile materials irradiation experiment.

b)

The core purge monitor will detect a radioactivity release that is higher than normal. The core purge monitor reading is taken hourly by the on console operator. A higher than normal reading will be reported to the Reactor Radiation Protection staff and sampling of the core purge is required to identify the cause. A "High Core Purge Monitor" alarm will alert the operator if the reading exceeds the setpoint of 100 kcpm.

c)

If the fission gas release is caused by high temperature of the fissile materials/barriers, an over-temperature alarm will automatically scram the reactor and thus minimize all fission products release.

An analysis is performed assuming that, as a result of multiple failures, all fission product gases produced from a fissile materials irradiation experiment are released through the reactor ventilation system. The fission product gases analyzed here are the noble gas nuclides including Kr-85m, Kr-87, Kr-88, Xe-131m, Xe-133m, Xe-133, and Xe-135. The fission product gas inventory is assumed to be at equilibrium at 100 kW (maximum allowable power of a fissile materials irradiation experiment) and is released within one week.

The analysis concludes that a) the core purge monitor should detect a higher reading, 44 kcpm over background, if the fission product gases were to escape the barriers, an increase equivalent to approximately twice that of a normal background reading, and b) if the entire fission product gas inventory leaks from a fissile materials irradiation experiment and is released to the atmosphere through the stack, the total inhalation dose is calculated to be about 17 mrem. The inhalation dose of 17 mrem is much lower than the 100 mrem annual limit for general public defined by 10 CFR 20.

SR#-0-01-1 I OCT 03 2001 There will be no additional thyroid dose because none of the fission product gases affect the thyroid.

5.

Proposed Wording for TS.16.7 See attached.

S#-0-01-11 OCT 03 2001

NUCLEAR REACTOR LABORATORY AN INTERDEPARTMENTAL CENTER OF MASSACHUSETTS INSTITUTE OF TECHNOLOGY LIN-WEN HU Reactor Relicensing Engineer 138 Albany Street, Cambridge, MA 02139-4296 Telefax No (617)253-7300 Telephone No. (617)258-5860 Email. lwhu@mit.edu Activation Analysis Coolant Chemistry Nuclear Medicine Reactor Engineering MEMORANDUM TO:

MITR Safety Review #0-01-11 FROM: Lin-Wen Hu DATE: October 25, 2001 RE:

Actinides Off-Site Dose Calculations During DBA

1.

One question that was brought up during the review of TS 6.7 " Experiments Involving Irradiation of Fissile Materials" was the amount of U-238 that would be allowed in addition to the fissile material (i.e., U-235). Irradiation of U-238 produces a very small percentage of fissions (fast fission), however, the activities of the actinides, especially the alpha-emitters, may contribute to additional whole body dose during the design basis accident.

2.

The actinides that are produced during irradiation are summarized in the table below. The activities at end of cycle (EOC) correspond to an initial U-238 loading of 330 grams and a burnup of 100 MWd/kg iHM (iHM: initial heavy metal), or 520 effective full power days of irradiation in the MITR at 5 MW. Most of the actinides (the ones with shorter half lives) reach equilibrium quickly and therefore higher burnup will not affect these activities.

For actinides with longer half-lives, i.e. Pu-238, Pu-239, Pu-240, and Pu-241, their activities increase with burnup.

Activities of the Pu nuclides are calculated from extrapolating data at lower burnups, which were calculated using MONTEBURN by Pavel Hejzlar.

Actinides Half-Life Decay Mode Activity Inhalation EOC (Ci)

ALI (tCi)

U237 6.75 days 1-decay to Np237 2.41 x 102 2x 10' U239 23.5 minutes 0-decay to Np239 4.60 x 103 2 x 105 Np238 2.12 days 3-decay to Pu238 35.6 60 Np239 2.36 days P-decay to Pu239 4.58 x 10' 2 x 103 Pu238 87.7 yrs a-decay to U234 2.735 7 x 10-3 Pu239 24110 yrs a-decay to U235 0.313 6x 10" Pu240 6564 yrs a-decay to U236 0.315 6 x 10.7 Pu241 14.35 yrs P-decay to Am241 129.3 0.3 Cm242 162.8 days a-decay to Pu238 0.777 0.3

3.

The off-site whole body dose contributed by the actinides is calculated by using the thyroid dose components as a reference. The thyroid dose was previously calculated by Q. Li (1998) using atmospheric release models which take into account both release from the pressure relief system (stack) and release from containment leakage. The containment leakage was concluded to be the dominant term for the atmospheric release at the reactor boundary. The thyroid dose during 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of release was calculated to be 135 mrem for a reactor power of 6 MW. These results are summarized in the MITR-III SAR. The ratio, R, of the off-site whole body dose resulting from the actinides to the previously determined off-site thyroid dose can be calculated using the following equation:

)-Ai x Dwb x (*f. Fd.FRCS'),

R ALIi (1)

ZAj x Dthyroid x(Ff.Fd.FRCS)j j

ALIj where denotes actinide isotopes U-237, U-239, Np-238, Np-239, Pu-238, Pu 239, Pu-240, Pu-241, and Cm-242, denotes thyroid-seeking nuclides 1-131, 1-132, 1-133, 1-134, 1-135, and Te

132, A

is activity, ALI is the annual limit on intake; the inhalation limits for whole body are used for the actinides, and the inhalation limits for thyroid are used for I and Te; Dwb is the annual dose limit for whole body (5 rem),

Dty*noid is the annual dose limit for thyroid (50 rem),

Ff is 1 for containment leakage (no charcoal filter),

Fd is natural depletion in containment, and FRCS is release fraction from fuel to reactor coolant system.

The whole body dose resulting from actinides can then be calculated using the following equation:

Dwb,actinides = R x Dthyroid,DBA (2) where Dthyroid,DBA is the calculated thyroid dose for DBA The release fractions for Iodine, Tellurium and actinides are summarized as following:

I f Fd FRCS Iodine 1

0.3 0.9 Tellurium 1

1 0.23 Actinides 1

1 le-4*

The RCS release fraction for actinides is obtained from severe fuel damage tests

[NUREG/CP-0090, June 1988].

4.

The off-site whole body dose resulting from irradiation of U-238 is calculated using Eqs (1) and (2).

Using a bumup of 100 MWd/kgiHM, the off-site whole body dose is calculated to be 0.002 mrem per gram of initial U-238, or 2 mrem per kg of initial U-238.

Assuming 100 grams U-235 is used in the fissile material irradiation (proposed TS limit),

the off-site whole body and thyroid doses resulting from complete damage of the material can be calculated from those of the reactor's DBA. The second column in the following table contains the off-site dose calculated by Q. Li for the reactor's DBA. The off-site doses in the third column are calculated for 100 grams of U-235 (without U-238), which is the proposed upper limit of the fissile material experiment.

(a)

(b)

Dose (mrem) (a)

Component of the Dose DBA (4 plates melted)

DBA (fissile mat. exp.)

21m(a) 21m(a)

Whole body:

Containment Leakage 12 9

Steel Dome Penetration 25 19 Shadow Shield Penetration 21 16 Air Scattering 75 56 Steel Scattering 114 84 Total 247 184 Thyroid:

Containment Leakage 134 99 Nearest point of public occupancy Calculation assumes that radiation emergency plan for protection of the public will be implemented in less than two hours.

247mrem - 18S4mrem Thus, the maximum allowed U-238 can be determined from

= 31.5 2mrem / kgU23 8 kgU238. This amount is significantly higher than that of natural uranium with 100 grams of U235, 0.1 kgU-235x(0.993/0.007)= 14.2 kgU-238. Therefore, a limit on initial amount of U-238 is not required.

NUCLEAR REACTOR LABORATORY IAN INTERDEPARTMENTAL CENTER OF "MASSACHUSETTS INSTITUTE OF TECHNOLOGY LIN-WEN HU 138 Albany Street, Cambridge, MA 02139-4296 Activation Analysis Reactor Relicensing Engineer Telefax No. (617)253-7300 Coolant Chemistry Telephone No (617)258-5860 Nuclear Medicine Email lwhu@mit edu Reactor Engineering MEMORANDUM TO:

MITR Safety Review #0-01-11 FROM: Lin-Wen Hu DATE: August 14, 2002 RE:

Off-Site Dose Calculations for Fission Product Gases Release I1.

Fission product gas release is an unlikely accident scenario because a) TS#6.7 requires weekly sampling of cover gas of a fissile materials irradiation experiment when the reactor power is at 100 kW or higher. This will detect any potential leakage of fission product gases from the barrier of a fissile materials experiment.

b) The core purge monitor will detect a radioactivity release that is significantly higher than normal.

The core purge monitor reading is taken hourly by the on-console operator. A higher than normal reading will be reported to the Reactor Radiation Protection staff and sampling of the core purge is required to identify the cause. A "High Core Purge Monitor" alarm will alert the operator if the reading exceeds the setpoint of 100 kcpm.

c) If the fission product gas release is caused by high temperature of the fissile materials/barriers, an over-temperature alarm will automatically scram the reactor and thus minimize all fission products release.

2.

An analysis is performed assuming that, as a result of multiple failures, all fission product gases produced from a fissile materials irradiation experiment are released through the reactor ventilation system. The fission product gases analyzed here are the noble gas nuclides including Kr-85m, Kr-87, Kr-88, Xe-13 Im, Xe-133m, Xe-133, and Xe-135. The fission product gas inventory is assumed to be at equilibrium at 100 kW (maximum allowable power of a fissile materials irradiation experiment) and is released within one week. The analysis concludes that a) The core purge monitor should detect a higher reading, 44 kcpm over background, if the fission product gases were to escape the barriers. The increase is approximately twice that of normal background.

b) If the entire fission product gas inventory leaks from a fissile materials irradiation experiment and is released to the atmosphere through the stack, the total inhalation dose is calculated to be about 17 mrem. There will be no additional thyroid dose because none of the fission product gases affects the thyroid.

Details of the above calculations can be found in the attached MathCAD worksheet.

Fission Product Gas Releases From Fissile Materials Irradiation Experiment (0: Kr85m, 1: Kr87, 2: Kr88, 3: Xel31m, 4: Xe133m, 5: Xe133, 6: Xe135) 100 Ratio 6000 (The fission product gas activities are proportional to power generation, fission product inventory obtained from calculations for MITR-4ll at 6 MW)

Ago := 0 7788.1O5.Ratio Ag,:= 1.404"10 5"Ratio Ag2 := 1.92"10 5"Ratio Ag3 := 00156.105 Ratio Ag4 := 0.083.10 5 Ratio Ag 5 := 3.37"10 5 Ratio Ag6 := 0.50.105.Ratio Ago = 1.298.103 Ag 1 =2 34.103 Ag 2 = 3.2.103 Ag3 = 26 Ag4 = 138.333 Ag5 = 5.617-103 Ag 6 = 833.333 Alimito0 := 1_1G-7 Alimiiti := 2.10" Alimit 2 := 9.10-9 Alimiit3 := 2.10-6 Alimit4 := 6.10-7 Alimit 5 := 5-10-7 Alimit6 := 7.10"'

ALIgo:= 0 7788-105.Ratio ALIgI := 1.404"10 5 'Ratio ALIg2 := 1.92"10 5 "Ratio ALIg 3 := 0.0156.10 5.Ratio ALIg 4 := 0083.105 Ratio ALIg 5 := 3.37-10 5"Ratio 5

ALIg96 : 0.50.10 *Ratio 6

SAgn = 1.345"104 n=0 i:= 0..6 Agi1.106 (Stack release concentration in microCi/cc for complete FP An

=[5000.40.(12.2.54)

.60.24.7 gas release over the duration of one week)

(Stack air flow rate -4000 cfm, 50000 is the dilution factor)

I

Ag =

1.298.10 3 2.34.103 3.2-103 26 138.333 5.617.103 833.333 Acono.

Alimit.

0.227 2.05 6.228

.277.10 -4

.039-10 -3 0.197 0.209 6

Z Aconcn n=0 Aconc =

DAC1 :=

210 5.10-6 2.10-6

.10-4 1_10"4 1_10-4

= 2.356.10-7 24.7 Aconc.

Dose.:= -4 5000 I

1 2000 DAC.

Dose = 14.

0.477 3.443 11.772 782.10-4 0.01 0.413 0.613 2.274.10"s 4.099.10"'

5 606.10"'

4.554.10f"° 2.423.10-9 9.839.10"8 1.46.10"'

Almiit =

1.10-7 2.10-8 9.10-9 2.10-6 6.10-7 5.10-7 7.10-8 (Dose received from inhalation within a week)

(The doses are calculated using inhalation DAC (occupational values) in 10 CFR 20 deverived for 2000 hours0.0231 days <br />0.556 hours <br />0.00331 weeks <br />7.61e-4 months <br /> per working year)

(The doses for each isotope are in mR) 6 Z

Dose

= 16.729 n=0

Purge (100 - 20).1000 110I

.106 (core purge set point 100k cpm, assuming detector efficiency 20%

37.101o 02 Purge has the unit of microCi per minute, background normally at 20 kcpm)

(core purge activity in microCi per minutes corresponds to the set point) 6 E

Ag..106 FPgasrate n=0 F~gsrte =I 10-( 12 -2.54)']'-(60"-24"-7)

FPgasrate = 4.713 FPgasrate = 0.436 Purge (Here is an approximation of a constant FP gas activity in microCi per minute over a week in the air space (- 10 ftA3) of the upper core tank. Normal core purge flow rate is 4 cpm)

(The core purge monitor will be about 44 kcpm higher if fission product gases leak)

Purge = 10 811

Page 6.7 Experiments Involving In-Core Irradiation of Fissile M aterials........................ 6-65

7.

ADMINISTRATIVE CONTROLS 7.1 Responsibility......................................................................................................

7-1 7.2 Reactor Staff Organization...................................................................................

7-4 7.3 Reactor Staff Qualifications.................................................................................

7-6 7.4 Retraining and Replacement Training..................................................................

7-8 7.5 Review..................................................................................................................

7-9 7.6 Action to be Taken in the Event of an Abnormal Occurrence........................... 7-18 7.7 Action to be Taken if a Safety Limit is Exceeded..............................................

7-19 7.8 Operating Procedures.........................................................................................

7-20 7.9 Experiment Approval Procedures......................................................................

7-22 7.10 Radiation Protection Program............................................................................

7-24 7.11 Security Program................................................................................................

7-25 7.12 Records Retention..............................................................................................

7-26 7.13 Plant Reporting Requirements...........................................................................

7-28 iv

7.

Radioactive Releases Experiments shall be designed so that operation is not predicted to result in exposures in excess of the limits of 10 CFR 20 to either onsite or offsite personnel or in releases of radioactivity in excess of the 10 CFR 20 annual average concentration limits.

Basis Accidents resulting from the step insertion of reactivity have been discussed in the SAR.

It was determined that following a step increase of 1.8% AK/K, fuel plate temperatures would be below the clad melting temperature and significant core damage would not result. The 0.2% AK/K limit for movable experiments corresponds to a 20 second period, one which can be easily controlled by the reactor operator with little effect on reactor power. The limiting value for a single non-secured experiment, 0.5% AK/K is set conservatively below the prompt critical value for reactivity insertion and below the minimum shutdown margin. The sum of the magnitudes of the static reactivity worths of all non-secured experiments, 1.0% AK/K, does not exceed the minimum shutdown margin. The total worth of all movable and non-secured experiments will not reduce the minimum shutdown margin as the shutdown margin is determined with all movable experiments in the most positive reactive state.

Specifications 2, 3, 4, 5 and 6 are intended to minimize the probability of experiment failures.

Experiment capsules should be designed to withstand expected temperatures, pressures, chemical and radiochemical effects. The requirement for testing containers at twice the pressure or with twice the amount of explosive or metastable material to be irradiated provides a factor of 2 safety margin as allowance for experimental uncertainties.

Table 6.1-1 gives a summary of the requirements for specimen irradiations for ease of review and classification of the specifications.

The radiological consequences of experiment malfunctions must be considered as stated in Specification 7. Consistent with the Commission's regulations, predicted onsite 6-5

personnel exposures or offsite concentrations resulting from these malfunctions must not be in excess of those permitted by 10 CFR Part 20.

6-6

6.7 Experiments Involving In-Core Irradiation of Fissile Materials Applicability This specification applies to the in-core irradiation of fissile materials. It does not apply to out-of-core irradiations.

Objective To ensure that fissile materials experiments do not affect safe operation of the reactor and to provide for the protection of the public health and safety by ensuring the integrity of irradiated fissile materials.

Specification

1.

In-core fissile materials irradiation experiments shall not contain circulating loops.

2.

The physical form of the fissile materials shall be solid. The fissile materials shall be doubly encapsulated to preclude radionuclide leakage during irradiation.

3.

The cross section of an in-core fissile materials experiment facility shall not exceed 16 square inches.

4.

The total initial amount of U-235 in each in-core fissile materials experiment shall not exceed 100 grams. Any mixture of fissile materials is permitted provided that the off-site dose consequences are less than those of 100 grams of U-235.

5.

Thermal power generated from each fissile materials experiment shall not exceed' 100 kW during irradiation.

6.

Each fissile materials irradiation experiment shall be monitored so that over temperature protection is provided by automatic reactor scram.

7.

Any void space between the inner and outer barriers of the double encapsulation shall be sampled at least weekly for indication of fission products during any week that the experiment is in core and the reactor power exceeds 100 kW. The finding shall be compared to a baseline and the reactor power shall be made less than 100 kW if fission product activity exceeds three times baseline.

6-65

8.

Design of the fissile materials experiments shall conform to the provisions of TS #6.1 "General Experiment Criteria".

Each proposed in-core fissile materials experiment shall require a documented safety review and approval by the MIT Reactor Safeguards Committee (MvITRSC) or, if authorized by the MITRSC, by its Subcommittee for in-core experiments.

Basis The MITR is licensed as a research reactor. Code of Federal Regulations 10 Part 50.2 defines a non-power reactor as a research or test reactor licensed under 10 CFR 50.21(c) or 50.22 for research and development. A test facility is defined in 10 CFR 50.2 as a nuclear reactor for which "...an application has been filed for a license authorizing operation at: (1) a thermal power level in excess of 10 megawatts; or (2) a thermal power level in excess of 1 megawatt, if the reactor is to contain: (i) a circulating loop through the core in which the applicant proposes to conduct fuel experiments; or (ii) a liquid fuel loading; or (iii) an experimental facility in the core in excess of 16 square inches in cross section."

Therefore, Technical Specifications 6.7.1, 6.7.2, and 6.7.3 are based on 50.2(2)(i), 50.2(2)(ii), and 50.2(2)(iii), respectively.

Other limits on the in-core irradiation of fissile materials specific to the MITR in core experiments are experiment reactivity worth limit and onset of nucleate boiling (ONB).

Additional requirements such as weekly sampling of cover gas in the void space and over temperature automatic reactor scram provide redundant protection against a potential malfunction of the fissile materials irradiation experiments. The limit on U-235 content in a fissile materials irradiation experiment is derived from the Design Basis Accident (DBA) of the reactor. The effect of actinides, which are produced from U-238, on off-site dose is analyzed. It is concluded that a limit on the initial amount ofU-238 is not required.

The Design Basis Accident (DBA) chosen for the MITR assumes a blockage of five coolant flow channels that results in four fuel plates completely melted [6.7-1]. Release of 6-66

the fission products to the atmosphere is calculated assuming that the fission product buildup achieved saturation. Off-site dose to the general public is then calculated from the released fission products.

The maximum amount of fissile materials that can be accommodated in a fissile materials experiment should result in a maximum fission product release below that of the DBA. Using an approximation based on the U-235 content, the maximum amount of U-235 would be 506 grams (mass of U-235 per fuel element) x 4 (plates) + 15 (plates per fuel element) = 135 grams. A limit of the total initial amount of 100 grams U-235 is conservatively chosen.

Actinides are produced when U-238 is irradiated. The off-site whole body dose from actinides was calculated to be 2 mrem per kilogram of initial U-238 [6.7-2]. The maximum initial amount of U-238, which is set by the total off-site dose from both fission products and actinides releases of the fissile materials experiment, was calculated to be 31 kilograms. This amount is significantly higher than that of natural uranium that contains 100 grams ofU-235, 0.1 kgU-235x(O.993/0.007)= 14.2 kgU-238. Therefore, a limit on the initial amount ofU-238 is not required.

The limit on the thermal power generated from the fissile materials experiment is primarily imposed by the onset of nucleate boiling (ONB), which is one of the criteria in TS

  1. 6.1. Each in-core fissile materials experiment design will be reviewed to ensure that ONB would not occur during steady-state operation. However, 100 kW, which is less than the average thermal power per fuel element of 200 kW, is used to set an upper bound for any fissile materials irradiation experiment.

The inner barrier of the double encapsulation is monitored for over-temperature.

The scram setpoint is experiment-dependent and will be chosen to avoid rapid mechanical and/or chemical degradation of the barrier. The scram setpoint will be documented in the safety review that is required by provision 8 of this technical specification.

Fission product gas release is an unlikely accident scenario An analysis is performed assuming that, as a result of multiple failures, the entire fission product gas inventory 6-67

produced from a fissile materials irradiation experiment is released through the reactor ventilation system. The fission product gases analyzed here are the noble gas nuclides including Kr-85m, Kr-87, Kr-88, Xe-131m, Xe-133m, Xe-133, and Xe-135. The fission product gas inventory is assumed to be at equilibrium at 100 kW (maximum allowable power of a fissile materials irradiation experiment) and is released within one week. The interval of one week is chosen because that is the frequency for the void space sampling.

This is a conservative assumption because a shorter interval will result in a much higher core purge monitor reading and hence increase the probability of detection. The analysis concludes that (a) the core purge monitor should detect a higher reading, 44 kcpm over background, if the fission product gases were to escape the barriers, an increase equivalent to approximately twice that of a normal background reading, and (b) if the entire fission product gas inventory leaks from a fissile materials irradiation experiment and is released to the atmosphere through the stack, the total inhalation dose is calculated to be about 17 mrem. The inhalation dose of 17 mrem is much lower than the 100 mrem annual limit for general public defined by 10 CFR 20. There will be no additional thyroid dose because none of the fission product gases affect the thyroid.

References 6.7-1 MITR Staff, "Safety Analysis Report for the MIT Research Reactor (MITR-II),"

Report No. MITNE-115, 22 Oct. 1970.

6.7-2 File Memo "Actinides Off-Site Dose Calculations During DBA, " Oct. 2001.

6.7-3 File Memo " Off-Site Dose Calculations for Fission Product Gases Release, August 2002.