0 to EP-PS-207, Site Support Manager: Emergency Plan - Position Specific Procedure
ML022460434
Person / Time
Site: Susquehanna  Talen Energy icon.png
Issue date: 08/23/2002
From:
Susquehanna
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
EP-PS-207-7
Download: ML022460434 (8)


Text

Aug.

23, 2002 Page 1

oft MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2002-39 5

USER INFORMATION:

PLAIJA÷LAUREL 1B EMPL#:23244 CA#:

0363

  • rss U:UCZA2 Phone#: 254-3658 TRANSMITTAL INFORMATION:

TO.

r)------

M.

lýf B

08/23/2002 LOCATION:

DOCUMENT CONTROL DESK FROM:

NUCLEAR RECORDS DOCUMENT CONTROL CENTER (NUCSA-2)

'_THE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU:

207 207 SITE SUPPORT MANAGER:

EMERGENCY PLAN POSITION SPECIFIC PROCEDURE REMOVE MANUAL TABLE OF CONTENTS DATE:

08/08/2002 ADD MANUAL TABLE OF CONTENTS DATE:

08/22/2002 CATEGORY:

PROCEDURES TYPE:

EP ID:

EP-PS-207 REPLACE:

REV:10 REPLACE:

REV:10 UPDATES FOR HARD COPY MANUALS WILL BE DISTRIBUTED WITHIN 5 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES.

PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON RECEIPT OF HARD COPY.

FOR ELECTRONIC MANUAL USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX.

_ 1 REM TEDE OR>

5 REM CDE CHILD THYROID AT A DISTANCE OF

> 2 MILES?

0 YES - If the projected doses at 2 miles are >_ 1 REM TEDE or Ž5 REM CDE child thyroid, then full evacuation (0-10 miles) is recommended.

(Go to PA-5) 0 NO/UNKNOWN- (Go to PA-4)

EP-AD-000-126, Revision 9, Page 3 of 6

TAB 7 EP-PS-207-7 0-I PA-4 RECOMMEND EVACUATION 0-2 MILES; SHELTER 2-10 MILES Limited Evacuation (0-2 miles) and sheltering is appropriate for events that are significant enough to cause a General Emergency classification and dose projections are low, unknown, or below full evacuation guidelines.

01 PA-5 EVACUATE 0-10 MILES Full evacuation of members of the general public is recommended at this point based on the emergency classification and dose projections.

EP-AD-000-1 26, Revision 9, Page 4 of 6

TAB 7 EP-PS-207-7 LIQUID

-:" PL-1 ENTRY This section is entered when there are indications of a potential radioactive liquid release.

Indications of potential releases include:

"* an unisolable radwaste tank release.

"* leaks to cooling tower basin

"* leak to spray pond (Go to PL-2) 0 PL-2 CHEMISTRY/ENVIRONMENTAL SAMPLING DIRECTOR (ESD) TAKES AND ANALYZES SAMPLE (Go to PL-3)

PL-3 IS RELEASE _Ž TECHNICAL REQUIREMENTS LIMITS (AT THE RELEASE POINT)?

El YES - Releases are at or greater than Technical Requirements limits when Chemistry determines that the limits are exceeded based on methodologies described in the ODCM and applicable Chemistry procedures.

El NO - If the release is < Technical Requirements limits, then no notifications are required and monitoring should continue.

(Go to PL-4)

D1 PL-4 RAD PERSONNEL NOTIFY DANVILLE AND BRP THAT A RELEASE HAS OCCURRED Depending on which facility is activated, the notification to Danville and BRP will be made by the RPC (TSC) or the Radiological Liaison (EOF).

DO NOT MAKE ANY PROTECTIVE ACTIONS RECOMMENDATIONS AT THIS TIME.

EP-AD-000-126, Revision 9, Page 5 of 6

TAB 7 EP-PS-207-7 0l PL-5 CHEM/FTD*EVALUATES RELEASE VERSUS PAGs The results of the sample analysis are compared to the PAGs for radionuclides in drinking water. The analysis calculates the expected concentration at Danville, taking into account the dilution afforded by the river.

PL-6 DOES RELEASE EXCEED PAGs (AT DANVILLE)?

o YES - If a single isotope exceeds the PAG or the sum of the fractions exceeds 1.0, then a protective action recommendation should be made for Danville to DIVERT its DRINKING WATER supply to a backup supply until the release has passed.

(Go to PL-7) o NO - If the PAGs are not exceeded, monitoring should continue and the State should be notified that no PAR for the liquid release is required. (Go to PL-8)

"o PL-7 RAD PERSONNEL NOTIFY DEP/BRP OF PAR Depending on which facility is activated, the PAR notification to DEP/BRP will be made by the RPC (TSC) or the Radiological Liaison (EOF). The PAR FORM shall be used to document the PAR.

DO NOT COMMUNICATE THE PROTECTIVE ACTION RECOMMENDATION TO DANVILLE. THE DEP/BRP IS RESPONSIBLE FOR THIS COMMUNICATION.

"0 PL-8 RAD PERSONNEL NOTIFY DEP/BRP No PAR is required. Depending on which facility is activated, the RPC (TSC) or the Radiological Liaison (EOF) shall notify DEP/BRP that no PAR is required.

EP-AD-000-126, Revision 9, Page 6 of 6