August 29, 2002 Mr. M. S. Tuckman Executive Vice-President Nuclear Generation Duke Energy Corporation P.O. Box 1006 EC07H Charlotte, NC 28201-1006

SUBJECT:

REVISED SCHEDULE FOR THE STAFFS REVIEW OF THE LICENSE RENEWAL APPLICATION FOR FOR MCGUIRE, UNITS 1 AND 2, AND CATAWBA, UNITS 1 AND 2

Dear Mr. Tuckman:

By a letter dated August 14, 2002, the Nuclear Regulatory Commission (NRC) transmitted the license renewal safety evaluation report (SER) with open items for McGuire, Units 1 and 2, and Catawba, Units 1 and 2. In the letter, the NRC requested a response to the open and confirmatory items identified in the SER by October 27, 2002. However, since that date is not a business day, a response by October 28, 2002, is requested. The letter also erroneously stated that a complete and revised SER will be issued by January 6, 2002 - the correct date is January 6, 2003.

Enclosed is a revised review schedule that reflects the change in date (from October 25, 2002, to October 28, 2002) for your response to the open and confirmatory items in the SER.

Additionally, a change in the dates for the ACRS subcommittee meeting (from October 2, 2002, to October 8, 2002) and full committee meeting (from October 9, 2002, to October 10, 2002) is indicated in the revised schedule. If you have any questions regarding this matter, please call me at 301-415-1868.

Sincerely,

/RA/

Rani Franovich, Project Manager License Renewal and Environmental Impacts Program Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket Nos. 50-369, 50-370, 50-413, and 50-414

Enclosure:

As stated cc w/encl: See next page

Mr. M. S. Tuckman Executive Vice-President Nuclear Generation Duke Energy Corporation P.O. Box 1006 EC07H Charlotte, NC 28201-1006

SUBJECT:

REVISED SCHEDULE FOR THE STAFFS REVIEW OF THE LICENSE RENEWAL APPLICATION FOR FOR MCGUIRE, UNITS 1 AND 2, AND CATAWBA, UNITS 1 AND 2

Dear Mr. Tuckman:

By a letter dated August 14, 2002, the Nuclear Regulatory Commission (NRC) transmitted the license renewal safety evaluation report (SER) with open items for McGuire, Units 1 and 2, and Catawba, Units 1 and 2. In the letter, the NRC requested a response to the open and confirmatory items identified in the SER by October 27, 2002. However, since that date is not a business day, a response by October 28, 2002, is requested. The letter also erroneously stated that a complete and revised SER will be issued by January 6, 2002 - the correct date is January 6, 2003.

Enclosed is a revised review schedule that reflects the change in date (from October 25, 2002, to October 28, 2002) for your response to the open and confirmatory items in the SER.

Additionally, a change in the dates for the ACRS subcommittee meeting (from October 2, 2002, to October 8, 2002) and full committee meeting (from October 9, 2002, to October 10, 2002) is indicated in the revised schedule. If you have any questions regarding this matter, please call me at 301-415-1868.

Sincerely,

/RA/

Rani Franovich, Project Manager License Renewal and Environmental Impacts Program Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket Nos. 50-369, 50-370, 50-413, and 50-414

Enclosure:

As stated cc w/encl: See next page DISTRIBUTION:

See next page Document Name: C:\\ORPCheckout\\FileNET\\ML022410304.wpd OFFICE PM:RLEP:DRIP LA SC:RLEP:DRIP NAME RFranovich HBerilla SLee DATE 08/29/02 08/28/02 08/29/02 OFFICIAL RECORD COPY

DISTRIBUTION: Letter to M.S. Tuckman, Dated: August 29, 2002 HARD COPY RLEP RF R. Franovich E-MAIL:

PUBLIC J. Johnson W. Borchardt D. Matthews F. Gillespie RidsNrrDe R. Barrett E. Imbro G. Bagchi K. Manoly W. Bateman J. Calvo C. Holden P. Shemanski H. Nieh G. Holahan H. Walker S. Black B. Boger D. Thatcher G. Galletti C. Li J. Moore R. Weisman M. Mayfield A. Murphy W. McDowell S. Droggitis T. Kobetz C. Munson RLEP Staff H. Walker R. Martin C. Patel C. Julian (RII)

R. Haag (RII)

S. Uttal (OGC)

M. Khanna

DUKE: McGuire and Catawba MILESTONE SCHEDULE DATE ACTUAL DATE Receive Duke Joint LRA 6/14/01 6/14/01 Application is accessible 7/3/01 6/28/01 FRN published for receipt & acceptability review 7/16/01 7/16/01 Press Release describing FRN 7/17/01 7/16/01 FRN published describing acc./rejection 8/15/01 8/15/01 FRN published for opportunity for hearing 8/15/01 8/15/01 Press Release describing FRN 8/16/01 8/15/01 FRN published for Intent/Env Scoping mtg (McGuire) 8/22/01 8/23/01 FRN published for Intent/Env Scoping mtg (Catawba) 9/13/01 9/20/01 Deadline for Filing Hearing Requests 9/14/01 9/14/01 Environmental Scoping Meeting (McGuire) 9/25/01 9/25/01 Scoping and Screening Methodology Audit Complete 10/19/01 10/19/01 EIS Scoping Period Ends (McGuire) 10/21/01 10/21/01 Environmental Scoping Meeting (Catawba) 10/23/01 10/23/01 EIS Scoping Period Ends (Catawba) 11/22/01 11/22/01 Env. RAIs Issued to Applicant (McGuire) 11/23/01 11/19/01 Env. RAIs Issued to Applicant (Catawba) 12/14/01 12/12/01 Env. RAIs Responses Issued to NRC (McGuire) 2/1/02 1/31/02 Safety RAIs issued by RLSB 1/30/02 1/30/02 Env. RAIs Responses Issued to NRC (Catawba) 2/11/02 2/8/02 Scoping Inspection Complete 3/29/02 3/22/02 Responses to Safety RAIs received 4/15/02 4/15/02 Draft SEIS to EPA, Issue Notice of Availability (McGuire) 5/17/02 5/06/02 & 5/10/02 Draft SEIS to EPA, Issue Notice of Availability (Catawba) 6/7/02 5/13/02 & 5/17/02 Public Meeting to Discuss DEIS (McGuire) 6/12/02 6/12/02 Public Meeting to Discuss DEIS (Catawba) 6/27/02 6/27/02 AMR Inspections Complete 7/26/02 7/26/02 End of DEIS Comment Period (McGuire) 8/2/02 8/2/02 SER w/OI issued by RLSB 8/12/02 8/14/02 End of DEIS Comment Period (Catawba) 8/9/02 8/9/02 ACRS Subcommittee of SER OI 10/8/02 ACRS Full committee of SER OI 10/10/02 Responses to SER OI received 10/28/02 Optional Final Inspection complete 11/29/02 SER issued by RLSB 1/6/03 Regional Administrators Letter 1/17/03 Final SEIS issued to EPA/Issue Notice of Availability (McGuire) 1/17/03 Final SEIS issued to EPA/Issue Notice of Availability (Catawba) 1/17/03 ACRS of full committee of SER 2/6/03 ACRS Letter 2/14/03 SER issued as NUREG 2/20/03 Commission Paper W/Staff Recommendations 9/8/03 Commission Decision 12/12/03 Enclosure

McGuire & Catawba Nuclear Stations, Units 1 and 2 cc:

Mr. G. R. Peterson Site Vice President Catawba Nuclear Station Duke Energy Corporation 4800 Concord Rd.

York, SC 29745 Mr. H. B. Barron Vice President, McGuire Site Duke Energy Corporation 12700 Hagers Ferry Rd.

Huntersville, NC 28078 Ms. Lisa F. Vaughn Legal Department (PBO5E)

Duke Energy Corporation 422 South Church St.

Charlotte, NC 28201-1006 County Manager of Mecklenburg County 720 East Fourth St.

Charlotte, NC 28202 Mr. Michael T. Cash Regulatory Compliance Manager Duke Energy Corporation McGuire Nuclear Site 12700 Hagers Ferry Rd.

Huntersville, NC 28078 Anne Cottingham, Esquire Winston and Strawn 1400 L Street, NW Washington, DC 20005 Senior Resident Inspector c/o U. S. Nuclear Regulatory Commission 12700 Hagers Ferry Rd.

Huntersville, NC 28078 Mr. Peter R. Harden, IV VP-Customer Relations and Sales Westinghouse Electric Company 6000 Fairview Rd., 12th Floor Charlotte, NC 28210 Dr. John M. Barry Mecklenburg County Department of Environmental Protection 700 N. Tryon St.

Charlotte, NC 28202 Mr. Richard M. Fry, Director Division of Radiation Protection North Carolina Department of Environment, Health, and Natural Resources 3825 Barrett Dr.

Raleigh, NC 27609-7721 Ms. Karen E. Long Assistant Attorney General North Carolina Department of Justice P. O. Box 629 Raleigh, NC 27602 Mr. C. Jeffrey Thomas Manager - Nuclear Regulatory Licensing Duke Energy Corporation 526 South Church St.

Charlotte, NC 28201-1006 Elaine Wathen Lead REP Planner Division of Emergency Management 116 West Jones St.

Raleigh, NC 27603-1335 Mr. T. Richard Puryear Owners Group (NCEMC)

Duke Energy Corporation 4800 Concord Rd.

York, SC 29745 Mr. Gary Gilbert Regulatory Compliance Manager Duke Energy Corporation 4800 Concord Rd.

York, SC 29745 North Carolina Municipal Power Agency Number 1 1427 Meadowwood Blvd.

P. O. Box 29513 Raleigh, NC 27626-0513 County Manager of York County York County Courthouse York, SC 29745 Piedmont Municipal Power Agency 121 Village Dr.

Greer, SC 29651 Saluda River Electric P. O. Box 929 Laurens, SC 29360 Virgil R. Autry, Director Division of Radioactive Waste Management Bureau of Solid and Hazardous Waste Department of Health and Environmental Control 2600 Bull St.

Columbia, SC 29201 North Carolina Electric Membership Corporation P. O. Box 27306 Raleigh, NC 27611 Senior Resident Inspector 4830 Concord Rd.

York, SC 29745 Lou Zeller Blue Ridge Environmental Defense League P.O. Box 88 Glendale Springs, NC 28629 Paul Gunter Nuclear Information &

Resource Service 1424 16th Street NW, Suite 404 Washington, DC 20036 Don Moniak Blue Ridge Environmental Defense League Aiken Office P.O. Box 3487 Aiken, SC 29802-3487 Mr. Kevin Cox The Huntersville Star P. O. Box 2542 Huntersville, NC 28070 Mr. Robert L. Gill, Jr.

Duke Energy Corporation Mail Stop EC-12R P. O. Box 1006 Charlotte, SC 28201-1006 Mr. Henry J. Porter, Assistant Director Division of Waste Management Bureau of Land & Waste Management S.C. Dept of Health and Environ. Control 2600 Bull St.

Columbia, SC 29201-1708 Mr. L. A. Keller Duke Energy Corporation 526 South Church St.

Charlotte, NC 28201-1006 Mr. Gregory D. Robison Duke Energy Corporation Mail Stop EC-12R 526 S. Church St.

Charlotte, NC 28201-1006 Mary Olson Nuclear Information & Resource Service Southeast Office P.O. Box 7586 Asheville, NC 28802 Mr. Alan P. Nelson Nuclear Energy Institute 1776 I Street, N.W., Suite 400 Washington, DC 20006-3708 APN@NEI.ORG