ML022400036

From kanterella
Jump to navigation Jump to search
Request for Amendment to the Technical Specifications Changes to Post-Accident Monitoring Instrumentation Requirements
ML022400036
Person / Time
Site: Pilgrim
Issue date: 08/19/2002
From: Ronald Bellamy
Entergy Nuclear Generation Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
2.02.072
Download: ML022400036 (36)


Text

Entergy Entergy Nuclear Generation Co.

Pilgrim Nuclear Power Station 600 Rocky Hill Road Plymouth, MA 02360 Mike Bellamy Site Vice President August 19,2002 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Mail Station O-P1-17 Washington, DC 20555-0001

SUBJECT:

Entergy Nuclear Operations, Inc.

Pilgrim Nuclear Power Station Docket No. 50-293 License No. DPR-35

REFERENCE:

LETTER NUMBER:

Dear Sir or Madam:

Request for Amendment to the Technical Specifications Changes to Post-Accident Monitoring Instrumentation Requirements NUREG 1433, Standard Technical Specifications for General Electric Plants, BWR/4 2.02.072 In accordance with the provisions of 10 CFR 50.90, Entergy Nuclear Operations, Inc. (Entergy) is submitting a request for an amendment to the Technical Specifications (TS) for Pilgrim Nuclear Power Station. This request is to change the requirements associated with post accident monitoring (PAM) instrumentation and make Pilgrim's Technical Specifications more consistent with the requirements in the standard technical specifications for boiling water reactors.

The Enclosure contains supporting information and a safety assessment of the proposed changes, including a determination of no significant hazards consideration. Attachment 1 is a marked-up version of the current technical specifications.

Entergy has reviewed the proposed changes using the criteria of 10 CFR 50.92 and concludes that the proposed changes do not involve a significant hazards consideration.

Entergy requests approval of the proposed amendment by March 1, 2003 to support Pilgrim's upcoming refueling outage (scheduled to commence on April 19, 2003). Once approved, the amendment will be implemented within 60 days.

202072

Entergy Nuclear Operations,'In'c' Pilgrim Nuclear Power Station

%Letter Number: 2.02.072 SPage 2 if you have any questions, please contact Mr. Bryan Ford at (508) 830-8403.

I declare under penalty of perjury that the foregoing is true and correct. Executed cn the z,4lL day of August 2002.

Sinzerely, Vobe~r meZy

Enclosure:

Attachment Evaluation of the Proposed Changes -11 pages 1: Marked-up Proposed Technical Specifications and Bases Changes 20 pages

2. List of Regulatory Commitments - 1 Page cc:

Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Mr. Travis Tate, Project Manager Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Mail Stop: O-8B-1 Washington, DC 20555-0001 Senior Resident Inspector U. S. Nuclear Regulatory Commission Pilgrim Nuclear Power Station 600 Rocky Hill Road M/S 66 Plymouth, MA 02360 Mr. Robert Hallisey Radiation Control Program Commonwealth of Massachusetts Executive Offices of Health and Human Services 174 Portland Street Boston, MA 02114 Mr. Steve McGrail, Director Massachusetts Emergency Management Agency 400 Worcester Road Framingham, MA 01702 202072

ENCLOSURE Evaluation of the Proposed Changes

Subject:

Changes to Post-Accident Monitoring Instrumentation Requirements

1.

DESCRIPTION

2.

PROPOSED CHANGES

3.

BACKGROUND 3.1 Post-Accident Monitoring Instrumentation 3.2 10 CFR 50.36(c)(2)(ii) and NRC Final Policy on the Improved Technical Specifications

4.

TECHNICAL ANALYSIS

5.

REGULATORY SAFETY ANALYSIS 5.1 No Significant Hazards Consideration

6.

ENVIRONMENTAL CONSIDERATION

7.

COORDINATION WITH OTHER PENDING CHANGES

8.

REFERENCES

1.

DESCRIPTION Entergy Nuclear Operations, Inc. (Entergy) proposes to amend the Technical Specifications (TS) to change the requirements associated with post-accident monitoring (PAM) instrumentation.

Entergy proposes to update the TS to:

a.

reflect post-accident instrumentation for the TS funct;ons meet.ng the guidance of NRC Regulatory Guide 1.97; and

b.

adopt standard limiting conditions for operations, action statements, allowable outage times, surveillance requirements, and reporting requirements for PAM instrumentation.

These changes will make Pilgrim's TS more consistent with the requirements in the Standard Technical Specifications for General Electric Plants, BWR/4, NUREG-1433 (Reference 1).

2.

PROPOSED CHANGES The following changes are proposed as part of this TS amendment.

A.

Titles Change the title of Specification 3/4.2.F from "Surveillance Information Readouts" to "Post-Accident Monitoring Instrumentation." Modify instrument function names.

B.

Applicability of the Requirements Change the conditions during which the requirements of Specification 3/4.2.F are applicable to when the unit is in the Run Mode or the Startup Mode.

C.

Changes to Columns on Table 3.2.F Delete the "Instrument #" and "Type Indication and Range" Columns from Table 3.2.F.

Also add an identifying number to each Function and move the "Minimum # of Operable Instrument Channels" column to following the Function name column.

D.

Required Action for One Inoperable Channel out of Two Channels (Excluding the Drywell High Radiation Function)

Change the required Action for one of two requircd channels of a Function being inoperable. The current Actions (current Table 3.2.F Notes (1) and (3)) require restoring the inoperable channel to operable status within 30 days or placing the unit in Cold Shutdown within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> while Specification 3.7.A.7.c requires restoration within 7 days or placing the unit in Hot Shutdown within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />. These Actions are changed in proposed Table 3.2.F Note (1) to restoring the inoperable channel to operable status within 30 days or submitting a special report within 14 days.

E.

Required Action for One Inoperable Channel out of Two Channels for the Drywell High Radiation Function Change the required Action for one of two required channels of the Drywell High Radiation Function being inoperable. The current Action (current Table 3.2.F Note (7))

requires restoring the inoperable channel to operable status within 7 days or submitting 1

a special report within" 14 days. This Action is changed in proposed Table 3.2.F Note (1) to restoring the inoperable channel to operable statusiwithin 30 days or submitting a special report within 14 days. Two inoperable Drywell High Radiation Function channels are addressed by the proposed Note (3).

F.

Required Action for No Control Room Indication of a Funct;on (Excluding the Containment H2 Analyzer and Drywell High Radiation Functions)

Change the required Action for having no indication in the control room for a Function.

The current Actions (current Table 3.2.F Notes (2) and (3)) require restoring control room indication within 7 days or placing the unit in Cold Shutdown within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. This Action is changed in proposed Table 3.2.F Note (2) to restoring control room indication within 7 days or placing the unit in Hot Shutdown within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

G.

Required Action for No Control Room Indication of the Containment H2 Analyzer Function Revise the limiting condition for operation from 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> to 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />, consistent with standard Technical Specifications. Move the current rGquiAd Action for having no indication in the control room (both required channels inoperable) of the Containment H2 Analyzer Function from Specification 3.7.A.7.c to proposed Note (4).

H.

-Deletion of Containment H2 Analyzer Function from TS 3/4.7.A.7.c Delete the Containment H2 Analyzer from Specification 3/4.3.7.A.7.c and add the requirements to Table 3/4.2.F.

1.

Non-Regulatory Guide 1.97, Type A or Category 1, non -Type A, Variables Delete the Suppression Chamber Air Temperature, Drywell/Torus Differential Pressure, Safety/Relief Valve Position, Safety Valve Position Indicator, Tail Pipe Temperature Indication, Reactor Building Vent, Main Stack Vent, and Tuibine Building Vent Functions

-from Specification 3/4.2.F.

J.

Instrument Check Frequency Change the required frequency of instrument checks to once per 31 days.

K.

Calibration Frequency Presentation Present the calibration frequencies consistently as once per 24 months for those functions with current requirements that effectively require the cal;bration once per 24 months.

L.

Number of Required Neutron Monitoring Channels The number of required neutron monitoring channels is Increased from 1 to 2.

M.

Instrument Channels Addressed b-y the Specification 3/4.2.F requirements With the removal of the "Instrument #" column from Table 3.2.F, the TS will no longer control the specific instrument numbers comprising each required Function. The specific instruments comprising each required Function is proposed to be modified as necessary 2

to reflect the currently credited Regulatory Guide 1.97, Type A or Category 1, non-Type A, instruments.

N.

Delete Note (2) on page 3/4.2-41 Delete Note (2) on TS page 3/4.2-41 to reflect that it is no lon.or used.

These proposed TS changes are indicated in Attachment 1. Also included in Attachment 1 for information are the conforming Bases chat iges, which will be made aftei approval of the proposed changes.

3.

BACKGROUND

1.

Post-Accident Monitoring Instrumentation The primary purpose of the PAM instrumentation is to display plantvariables that provide information required by the control room operators during accid&-nt situations. This information provides the necessary support for the operator to take the manual actions for which no automatic control is provided and that are required for safety systems to accomplish their safety functions for design basis events.

The purpose of PAM instrumentation for Regulatory Guide 1.97, Type A variables is to provide information so that the control room operating staff can:

Perform the diagnosis specified in the Emergency Operating Procedures (EOPs).

These variables are restricted to preplanned actions for the primary success path of Design Basis Accidents (DBAs), (e.g., loss of coolant accident (LOCA)), and

  • Take the specified, preplanned, manually controlled actions for which no automatic cor'trol is providod, which are required for safety systems to accomplish their safety function.

The purpose of PAM instrumentation for Regulatory Guide 1.97, Category 1, non-Type A, variables is to provide information so that the control room operating staff can:

"* Determine whether systems important to safety are performing their intended functions;

"* Determine the potential for causing a gross breach of the barriers to radioactivity release;

"* Determine whether a oross breach-&ofa barrier has occurred; and

"* Initiate action necessary to protect the public and for an estimate of the magnitude of any impending threat.

Information on Pilgrim's post-accident monitoring instrumentation can be found in Pilgrim's Final Safety Analysis Rerort (FSAR) Section 7.8.10, "Post-Accident Monitoring."

FSAR Table 7.8-3 lists PAM panel instrument specifications. The NRC issued two SERs 3

for Pilgrim regardirng 'post-accident instrumentation bihb'Regulatory Guide 1.97 (References 2 and 3).

The operability of the accident monitor~ng instrumentation ensures th3t there is sufficient information available on selected plant parameters to monitor and asses. Olant status and behavior following an accident. This capability is consistent with thi.

recommendations of Regulatory Guide 1.97.

2.

10 CFR 50.36(c)(2)(ii) and NRC Final Po'icy Statement The NRC Final Policy Statement on the Improved Technical Specifications (ITS), states that the purpose o the technical specifications is to impose those conditions or limitations on reactor operations necessary to obviate the possibility of an abnormal situation or event giving rise to an immediate threat to the public health and safety by identifying those featuies which are of controlling importance to safety and establishing on them certain conditions of operation which cannot be changed without prior Commission approval. To achieve that purpose, the final policy statement provides four criteria that delineate those constraints on design and operaiion of nuclear power plants that must be retained in the technical specifications. These criteria were subsequently incorporated into 10 CFR 50.36(c)(2)(ii).

Criterion 1 - Installed instrumentation that is usea to detect, and indicate in the control room, a significant abnormal degradation of the reactor coolant pressure boundary. (10 CFR 50.36(c)(2)(ii)(A))

Criterion 2-A process variable, design featuru, or operating restriction that is an initial condition of a design basis accident (DBA) or transient analysis that either assumes the failure of or presents a challenge to ihe intsgrity of a fission product barrier. (10 CFR 50.36(c)(2)(ii)(1.))

Criterion 2-A structuro, syv.tem, or component that is part of the primary success path and which functions or actuates to mitigate a DBA or tr insient that either assumes the failure of or presents a challenge to the integrity of a fission product barrier. (10 CFR 50.36(c)(2)(ii)(C))

Criterion 4-A structure or component which operating experience o," probabilistic safety assessment has shown to be significant to public h',aith and safety. (10 CFR 50.36(c)(2)(ii)(D))

As discussed in NUREG-1433, the PAM instrumentation th.A mo;titors the Regulatory Guide 1.97, Type A and Category 1, non-Type A, vari-.ble. is the monitoring instrumentation which meets thi qcreening criteria in the final po:icy statement and 10 CFR 50.36(c)(2)(ii).

4.

TECHNICAL ANALYSIS The following is the justification for the changes propr3C,,: `:- part of this TS amendment.

A. Titles The changes in the title of Specification 3/4.2.F from Surveillance Information Readouts to Post-Accident Monitoring Instrumentation and function names are editorial changes to reflect the function of the instruments controlled. These changes do not result in any change in requirements.

4

B. Applicability of the Requirements The current Specifications have various implied conditions during which the requirements were applicable by having different required Action end states for different Functions. These various implied applicabilities are made consistent and changed,o requ::. §:Ie Functions to be operable when the unit is in the Run Mode or the Startup Mode.

Having the PAM instrumentation required to be operable in the Run and Startup Modes provides the appropriate controls on the instrumentation. These variables ame related to the diagnosis and preplanned actions required to mitigate DBAs.jThe applicable DBAs are assumed to occur in Run or Startup Modes. In the other plant operational modes, plant conditions are such that the likelihood of an event that would requir3 PAM instrumentation is extremely low; therefore, PAM instrumentation should not be required to be operable in these modes.

C. Columns on Table 3.2.F Deleting the "Instrument #" and "Type Indication and Ranger Columns from Table 3.2.F removes design details which are more appropriately controlled by plant procedures.

Removal of these details is consistent with NUREG-1433.

Adding an identifying number to each Function and moving the "Minimum # of Operable Instrument Channels" column following the Function name column are editorial changes.

These changes do not result in any changes in the TS requirements.

D. Required Action for One Inoperable Channel out of Two Channels (Excluding the Drywell High Radiation Function)

The proposed 30-day allowed out-of-service time for one inoperable channel out of two required channels for a Function with subsequent reporting to the NRC provides the appropriate required Action for the condition. The 30-day completion time is appropriate based on operating experience and takes into account the remaining operable channel, the passive nature of the instrument (no critical automatic action is assumed to occur from these instruments), and the low probability of an event requiring PAM instrumentation during this interval. The required action of submitting a report in lieu of the current shutdown requirement is appropriate, since alternative actions are identified as part of the report, there is no loss of functional capability, and given the likelihood of plant conditions that would require information provided by this instrumentation.

E. Required Action for One Inoperable Channel out of Two Channels for the Drywell High Radiation Function The proposed 30-day allowed out-of-service time for one inoperable channel out of two required channels for the Drywell High Radiation Function instead of the current 7 days prior to reporting the condition to the NRC provides the appropriate roquired Action for the condition. The 30-day completion time is appropriate based on operating experience and takes into account the remaining operable channel, the passive nature of the instrument (no critical automatic action is assumed to occur from these instruments), and the low probability of an event requiring PAM instrumentation during this interval.

5

FRueAi Z

F. Required Action for No Control Room Indication of a Function (Excluding the Containment H2 Analyzer and Drywell High Radiation Functions)

The proposed required Actions modify the end state of the unit if there is nc indication in the con~rol room for a Function and contro: room indication is not r6stored within 7 days. The current required Actions require placing the unit in Cold Shutdown within 21. hours while the proposed required Action is to place the unit in Hot Shutdown within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />. This change is consistent with the proposed change in when the PAM instrumentation is required to be operable.

Having the unit exit the Run and Startup Modes provides the appropriate controls for the subject conditions. These variables are related to the diagnosis and preplanned actions required to mitigate DBAs. The applicable DBAs are assumed to occur in Run or Startup Modes. In the other plant operational modes, plant conditions are such that the likelihood of an event that would require PAM instrumentation is extremely low; therefore, exiting the Run and Startup Modes provides the appropriate action under the evaluated conditions.

G. Required Action for No Control Room Indication of the Containment H2 Analyzer Function This revision changes the LCO from 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> to 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />, consistent with standard technical specifications 3.3.3.1 and B 3.3.3.1 D.1. The 72-hour Completion Time is based on the low piobability of the occurrence of a LOCA that wculd generate hydrogen ii amounts capable of exceeding the flammability limit.

H. Deletion of Conta;nment H2 Analyzer from TS 3/4.7.A.7.c This is an editorial chp.ngc only. Any non-editorial changes are discussed in other sections.

I. Non-Reguiatory Guide 1.*7, Type A or Category 1, non-Type A, Variables The Functions proposed to bc deleted are not instrumentation that monitors the Regulatory Guide 1.97, Type A and Category 1 non-Typc A, variables. Therefore, this instrumentation does not meet the screening criteria in the final policy statement and 10 CFR 50.36(c)(2)(ii) and removal from the TS is appropriate.

J. Instrument Check Frequency The current TS requirements have various frequencies identified for performing the required Instrument Check (i.e., each shift, once each day, once every 30 days, and once per month).

These required frequencies are made consistent with NUREG-1 433.

Performance of the Instrument Check once every 31 days ensures that a gross failure of instrumentation has not occurred. An Instrument Check is normally a comparison of the parameter indicated on one channel against a similar parameter on other channels. It is based on the assumption that instrument channels monitoring the same parameter should read approximately the same value. Significant deviations between instrument channels could be an indication of excessive instrument drift in one of the channels or something even more serious. An Instrument Check will d&-0c" gro:s channel failure; thus, it is key to verifying the instrumentation continues to operate properly between calibrations. The proposed Frequency of 31 days is based uporn plant operating experience, with regard to channel operability and drift, which demonstrates that failure of more than one channel of a given Function in any 31-day interval is rare. The Instrument Check supplements less 6

formal, but more frequerit, checks of channels during normal operational use of those displays associated with required channels.

K. Calibration Frequency Presentation The current TS requirements have various presentations of the rcequired ce libration frequencies all of which effectively require the calibration a minimum of once per 24 months (i.e., each refueling outage, once each operating cycle, and each start jp,. The presentation of these required frequencies are made consistent with NUREG--,433 as once per 24 months. This change in presentation of the required interval does not change the maximum interval between calibrations required by the TS for these instruments because the current refueling interval for Pilgrim is 24 months. This change in presentation does remove restrictions on the plant conditions under which the calibration can be performed. Removal of these restrictions is acceptable because implementation of the controls of 10 CFR 50.65 will continue to provide the necessary assurance that the calibrations are not performed during inappropriate plant conditions.

L. Number of Required Neutron Monitoring Channels Increasing the number of required neutron monitoring channels from 1 to 2 is a more restrictive TS requirement. This change does not modify the design or operation of the plant but only results in more conservative TS requirements.

M. Instrument Channels Addressed by the Specification 3/4.2.F requirements With the removal of the "Instrument #" column from Table 3.2.F the TS will no longer control the specific instrument numbers comprising each required Function. But only instrumentation that meets the design requirements for Regulatory Guide 1.97, Type A or Category 1, non-Type A, instruments should be used to meet the minimum required channels requirements of the TS. Therefore, the specific instruments comprising each required Function is proposed to be modified as necessary to reflect the credited Regulatory Guide 1.97, Type A or Category 1 non Type A instruments. The following are the credited Regulatory Guide 1.97, Type A or Category 1, non-Type A, instruments for the proposed TS required Functions.

Function Current TS Regulatory Guide i.97 Instruments Instrumentr,

1.

Reactor Water Level 640-29A LI-263-100A 640-292

!-1-263-100B LI-263-106A

-I-263-106B LI-1001-650A LI-1 001-650B LR-1001-604A LR-1001-604B

2.

Reactor Pressure 640-25A PI-253-49A 640-25B PI-233-49B PR-1001-600A PR-1001-600B 7

Function

3.

Drywell Temperature

4.

Neutron Monitoring

5.

Suppression Chamber Water Temperature

6.

Suppression Chamber Bottom Pressure

7.

Suppression Chamber Water Level

8.

Drywell Pressure (Wide Range)

9.

Drywell Pressure (Narrow Range)

10.

Drywell High Radiation

11.

Containment H2 Analyzer Current TS.

Instruments TRU-9044 TI-9019 APRM IRM SRM TI-5021-2A TI-5022-2B PID-5067A PID-5067B LR-5038 LR-5049 PI-1001-600A PR-1001-600A PI-1001-600B PR-1001-600B

'PI-1001-601A PR-1001-600A PI-1001-601B PR-10G1-600B RIT-1001-606A RIT-1001-606B

-. RR-100i-606A RR-1001 606B AR-1001-612A APR-1001-612B Regulatory Guide 1.97 Instruments TRU-9044 TI-9019 APRM SRM TI 5021-02A TI 5022-02B TRU-5021-01A TRU-5022-01 B PI-1001-69A PI-1001-69B PR-1001-69 LI-1001 604A LI-1001 604B LR-1001-604A LR-1001-604B PI-1001-600A PR-1001-600A PI-1001-600B PR-100, -600B PI-1001-601A PR-1001-600A P1-1001-601B PR-1001-600B RIT-1001-606A RIT-1001 -606B RR-1001-606A RR-1001 606B AR 1001-612A AR-1001-612B Al-1 -5184A Al-'i-5184B N. Delete Note (2) on page 3/4.2-41 With the revised presentation of tho calibration frequency requirements, Note (2) is no longer used on Table 4.2.F. Deletion of this Note is dependant upon the prior approval of the proposed TS change concerning the relocation of certain Control Rod Block functions submitted via Reference 5. If the changes requested in Reference 5 are not approved prior to the approval of this proposed change, then Note (2) should not be deleted as part of this change.

In Reference 4, the NRC approved required actions similar to those proposed by this submittal.

8

As a result, there are no credible failures that could initiate a new or different kind of accident from'a6y accident previously evaluated.""

Therefore, this proposed amendment does not create the possibility of a new or different kind of accident from any previously analyzed.

3. Does the change involve a significant reduction in the margin o! sEý,Cty?

Response: No PAM instrumentation performs no automatic functions. PAM instruments help to ensure that operato.s take necessary manual actions to mitigate the consequences of an accident, and that operators have adequate information to confirm the operation of automati, accident mitigation functions have occurred. The proposed required actions, allowed out-of-service times, and surveillance intervals are appropriate based on operating experience, other instrumentation available, the passive nature of the instrument (no critical automatic action is assumed tc occur from these instruments), and the low probability of an event requiring PAM instrumentation.

Therefore, this proposed amendment does not involve a significant reduction in margin of safety.

Based on the above, Entergy concludes that the proposed amendment presents no significant hazards consideration under the standards set forth in 10 CFR 50.92(c), and accordingly, a finding of "no significant hazards consideration" is justified.

6.

ENVIRONMENTAL CONSIDERATION A review has determined that the proposed amendment would change a requirement with respect to installation or use of a facility component located within the restricted area, as defined in 10 CFR 20, or would change an inspection or surveillance requirement. However, the proposed amendment does not involve (i) a significant hazards consideration, (ii) a significant change in the types or significant increase in the amounts of any effluent that may be released offsite, or'(iii) a significant increase in individual or cumulative occupational radiation exposure.

Accordingly, the proposed amendment meets the eligibility criterion for categorical exclusion set forth in 10 CFR 51.22(c)(9). Therefore, pursuant to 10 CFR 51.22(b), no environmental impact statement or environmental assessment need to be prepared in connection with the proposed amendment.

7.

COORDINATION WITH OTHER PENDING TS CHANGES The markups of the TS submitted with this change delete Note (2) on TS page 3/4.2-41.

Deletion of this Note is dependant upon the prior approval of the proposed TS change concerning the relocation of certain Control Rod Block functions submitted via Refer6nce 5. If the changes requested in Reference 5 are not approved prior to the approval of this proposed change, then Note (2) should not be deleted as part of this change.

8.

REFERENCES

1. NUREG-1433, "Standard Technical Specifications General Electric Plants, BWR/4,"

Revision 2.

10

2. NRC letter, S. F. Shankman to G. W. Davis, dated March 13,1991 regarding "Safety Evaluation of the Pilg iim Nuclear Power Station Respohse to Conformance to Regulatory Guide 1.97 (TAC NO. 51119).
3. NRC letter, R. B. Eaton to R. A. Anderson, dated December 23, 1992 regarding "Supplemental Safety Evaluation of Conformance to Regulatory Guide (R. G.) 1.97 for Pilgrim Nuclear Power Station (PNPS) (TAC NO. M51119)."
4. NRC letter, R. M. Pulsifer to M. Balduzzi, dated May 10, 2002 regarding "Vermont Yankee Nuclear Power Station - Issuance of Amendment Re: Allowed Outage Times for Post Accident Monitoring Instrumentation (TAC No. MB3430)."
5. Entergy letter 2.02.064, R.M. Bellamy to NRC, dated August 19, 2002.

A 11

ATTACHMENT 1 PROPOSED TECHNICAL SPECIFICATION AND BASES CHANGES (MARK-UP)

LIMITING CONDITION FOR OPERATION 3.2 PROTECTIVE INSTRUMENTATION (Cont)

E.

Drywell Leak Detection SURVEILLANCE REQUIREMENT 4.2 PROTECTIVE INSTRUMENTATION (Cont)

E.

DrVwell Leak Detection The limiting conditions of Instrumentation shall be operation for the instrumentation functionally tested, calibrated that monitors drywell leak and checked as indicated in detection are given in Section, Section 4.6.C.

3.6.C.

F.

Surveillance Information Readouts eillance Information Readouts Instrumentation shall be The limiting conditions'or I calibrated and checked as Sinstrumentation that provides indict Nksurveillance information readouts regvnin Table 3.2.F.

1o

/~

Revision +/--7 Amendment No.

89;-11 3/4.2-3 "

INSERT 3/4.2-3A F.

Post-Accident Monitoring Instrumentation F.

Post-Accident Monitoring Instrumentation During the RUN MODE and the STARTUP Instrumentation shall be calibmated and MODE the limiting conditions for the checked as indicated in Table 4.2.F.

instrumentation that provides post-accident monitoring are given in Table 3.2.F.

PNPS TABLE 3.2.F SURVEILLANCE INSTRUMENTATION Minirfu

  1. of Operable Insrument Instrument #

Parameter Channels 2

-29A & B Reactor Water Level 2

640-25A &Reactor Pressure 2

TRU-9044 ell Pressure TRU-9045 2

TRU-9044 Drywell Temper tuN TI-9019 2

TRU-9045 Suppression Chamt TI-9018 Temperature 2

LR-5038 Suppression Chamt LR-5049 Level 1

NA Neutron Monitoring

]er Air -"

er Water Type Indication and Range Notes Indicator 0-60" (1) (2) (3)

Indicator 0-1200 psig (1) (2) (3)

Recorder 0-80 psia (1) (2) (3)

Recorder, Indicator 0-400°F (1) (2) (3)

Recorder, Indicator 0-400°F (1) (2) (3)

Recorder o 0+7 inches (1) (2) (3)

SRM, IRM, LPRM (2) (3)(4) 0 to 100% power Revision 2 Amendment No. 1 t816-3/4.2-25 I

I

INSERT 3/4.2-25A PNPS TABLE 3.2.F Post-Accident Monitoring Instrumentation Minimum # of Operable Function Instrument Channels Reactor Water Level 2

Reactor Pressure 2

Drywell Temperature 2

Neutron Monitoring 2

Suppression Chamber Water Temperature 2

Suppression Chamber Bottom Pressure 2

Suppression Chamber Water Level 2

Drywell Pressure (Wide Range) 2 Drywell Pressure (Narrow Range) 2 Drywell High Radiation 2

Containment H2 Analyzer 2

2.
3.
4.
5.
6.

7

8.
9.
10.

11.

Notes (1) (2)

(1) (2)

(1) (2)

(1) (2)

(1) (2)

(1) (2)

(1) (2)

(1) (2)

(1) (2)

(1) (3)

(1) (4)

INSERi 3/4.2-25A Continued Notes for Table 3.2.F (1)

With less than the minimum number of instrument channels, restor3 the mnooerable channel(s) within 30 days. Ii the inoperable channel(s) are rict restoled, Vrepare and submit a special report to the Commission within 14 days of the event outlining i.i ac.tion taken, the cause of the inoperability and the plans and schedule for restoring the char.iiels to operable status.

(2)

With the instrument channel(s) providing no indication to the control room, restore the indication to the control room within 7 days. If the indication is not restorod, an orderly shutdown shall be initiated and the reactor shall be in the Hot Shutdown Condition within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

(3)

With the instrument channel(s) providing no indication to the control room, restore the indication to the control room within 7 days. If the indication is not restored, prepare and submit a special report to the Commission within 14 days of the event outlining the action taken, the cause of the inoperability and the plans and schedule for restoring the channels to operable status.

(4)

With the instrument channel providing no indication to the control room, restore the indication to the control room within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />. If the indication is not "'stored, an orderly shutdown shall be initiated and the reactor shall be in the Hot Shutdown Condition within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

- 11 1 -

PNPS TAELE 3.2.F7 (Cont)

.Tnse~rT '

SURVEILLANCE INSTRUMENTATION r

Revision 196 Amendment No. 56r-83-,172 3/4.2-26 "r

,Minimum # of Operable Instrument Parameter Type Indication Notes annels Instrument #

and Range TI-5021-2A Suppression Chamber Indicator/

TRU-5021-1A Water Temperature Multipoint Recorder (1) (2) (3) (4) 30-230°F (Bulk)

-2B Suppression Chamber Indicator/

TRU-11B Water Temperature Multipoint Recorder (1) (2) (3) (4)

"30-230°F (Bulk)

-0Drywell/Torus Diff.

Indicator -.25 - +3.0 psig (1) (2) (3) (4) 1 PID5021,Pressure 1

PID-5067A D;ý Pressure Indicator -.25 - +3.0 psig (1) (2) (3) (4)

PID-5067B Torus Pr ý,e Indicator - 1.0 - +2.0 psig 1Nalve (a)Primary Safety/Relief a

(a) Acoustic monitor (5) or Position (b) Thermocouple (b) Backup INalve (a)Primary Safety Valve Position (a

stic monitor (5) or Indicator (b) The o couple (b) Backup INalve See Note (6)

Tail Pipe Temperature Thermocouple Indication LI-1001-604A Torus Water Level Indicator/Multipoint (1)"3)

(4) 2 LR-1001-604A (Wide Range)

Recorder 0-300" H20 LI-1001-604B LR-1001-604B Torus Water Level Indicator/Multipoint (1) (2) (3) (4)

(Wide Range)

Recorder 0-300" H20

INSERT 3/4.2-25A Continued Pages 3/4.2-27 and 3/4.2-28 have been deleted.

PNPS TABLE 3.2.F (Cont)

C"D17W1TTTAUPV T?3CTDTtW1?JTArTTA)

Type Indication and Ranze (PI 1001-600A Containment Pressure, Indicator/Multipoint PR 1001-600A (High Range)

Recorder 0-225 psig (PI I 1-600B Containment Pressure, Indicator/Multipoint (PR 1001-OB (High Range)

Recorder 0-225 psig (PI 1001-601A ontainment Pressure, Indicator/Multipoint (PR 1001-600A (L

Range)

Recorder -5 to 5 psif (PI 1001-601B Containmen

ressure, Indicator/Multipoint (PR 1001-600B (Low Range)

Recorder -5 to 5 psi*

(RIT 1001-606A Containment High Radia n

Monitor/Multipoint (RIT 1001-606B (Drywell)

Recorder (RR 1001-606A to 1x10 7 R/hr (RR 1001-606B RI 1001-609 Reactor Building Vent Indicator/

ipoint RR 1001-608 Recorder 10-1 to 104 R/hr RI 1001-608 RR 1001-608 RI 1001-610 RR 1001-608 Main Stack Vent Turbine Building Vent Notes (4) (1) (2)

(3),"

(4)

(1) (2)

(3)

(4)

(1)

(2)

(3)

(4)

(7) (2)

(3)

(4)

(7)

(4)

(7) 7.

Indicator/Multipoint Recorder 10-1 to 104 R/hr Indicator/Multipoint Recorder 10-1 to 104 R/hr (7)

(4)

(7)

Revision W7 Amendment No.

567-837;t4"7

  1. of

!nt Instrument #

2 Parameter 2

2 3/4.2-27

NOTES FOR TABLE 3.2.F (1)

With less than, the minimum number of instrument channels, restore the inoperable channel(s) within 30 days.

)

With the instrument channel(s) providing no indication to the control room, restore the indication to the control, room within seven days.

(3) f the requirements of notes (l)--or (2) cannot be met, an orderly shutdown s 11 be initiated and the reactor shall be in the'Cold Shutdown Condition

, wit *n-24 hours.

(4)

These urveillance instruments are considered to be red-ni-d~nt to each other.

(5)

At a minilnum, the primary or back-up* parameter indicators shall be operable for each vakve when the valves are required to be operable.

With both primar and backup* ih trument channels inoperable either return one (1) channel to operable status ithin 31 days or be in a shutdown mode within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

The following inst, ents are associated with the safety/relief and safety valves:

  • See Note (6)

(6)

At a minimum, for thermocouples providing SRV tail pipe tem erature, one of the dual thermocouples will be operable for each SRV when the valves are required to be operable.

If a thermocouple becomes inoperable, it shall be returned to an operable condition within 31 days or the reactor all be placed in a shutdown mode within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

(7)

With less than the minimum number of operable instrument channels, re tore the inoperable channels to operable status within 7 days or prepare and su\\it a

special report to the Commission within 14 days of the event outlining t e action taken, the cause of the inoperability and the plans and schedule f restoring the channels to operable status.

Revision 177 Amendment No.

4 8 T-8 3 T--I 3

3/4.2-28 Primary\\

Secondary Valve Acoustic Monii r

Tail Pipe Temperature Thermocouple 203-3A ZT-203-3A TE6271 203-3B ZT-203-3B TE6272 203-3C ZT-203-3C TE6273 203-3D ZT-203-3D TE6276 203-4A ZT-203-4A TE6274-B 203-4B ZT-203-4B 6275-B

PNPS TABLE 4.2.F PNP

,INIMUM TEST AND CALIBRATION FREQUENCY FOR SURVEILLANCE INSTRUMENTATION Instrument C nnel Calibration Frequency Instrument Check

1) Reactor Water Level Each Refueling Outage Each Shift
2) Reactor Pressure Each Refueling Outage Each Shift
3) Drywell Pressure Each Refueling Outage Each Shift
4) Drywell Temperature Once/6 Months Each Shift
5) Suppression Cham ber Tem perature O n-"Months Each Shift
6) Suppression Chamber Water Level Once/6 Mon h Each Shift
7) NA
8) Neutron Monitoring (2)

Each Shift

9) Drywell/Torus Differential Pressure Once/6 Months Each Shift
10) Drywell Pressure Once/6 Months Each Shift Torus Pressure Once/6 Months
11) Safety/Relief Valve Position Indicator Each refueling outage Onc ach day (Primary/Secondary)
  • 12) Safety Valve Position Indicator Each refueling outage Once each da (Primary/ Secondary)

Am endm ent No. 34-48 -,97, 3/4.2-37 1--1/

INSERT 3/4.2-37A PNPS TABLE 4.2.F MINIMUM TEST AND CALIBRATION FREQUENCY FOR Post-Accident Monitoring Instrumentation Function Reactor Water Level Reactor Pressure Drywell Temperature Neutron Monitoring Suppression Chamber Water Temperature Suppression Chamber Bottom Pressure Suppression Chamber Water Level Drywell Pressure (Wide Range)

Drywell Pressure (Narrow Range)

Drywell High Radiation Containment H2 Analyzer Calibration Frequency Once/24 Months Once/24 Months Once/6 Months Once/24 Monihs Once/6 Months Once/6 Months Once/24 Months Once/24 Months Once/24 Months Once/24 Months Once/6 Months Instrui.innt Che-ek Once/31 Days Once/31 Days Once/31 Days Ornc6/31 Dayv Once/31 Days Once/31 Days Once/31 Days Once/31 Days Once/31 Days Once/31 Days Once/31 Days

1.
2.
3.
4.

5

6.
7.
8.
9.
10.

11.

INSERI 3/4.2-37A Continued Page 3/4.2-37 has been deleied.

PupS TABLE 4.2.F (Cont)

MINIMUM TEST AND CALIBRATION FREQUENCY FOR SURVEILLANCE INSTRUMENTATION I-Qannel Calibration Frequency Instrument Check iter Level ( Wde e

Each refueling outage Once every 30 days ient Pressure Each refueling outage Once every 30 days ent High Radiation Once/Op Cycle Once every 30 days 3uilding Vent Radiation Monitor Once/Operating Cycle Once every 30 days ck Vent Radiation Monitor Once/Operating Cycle Onc 30 days

13)
14)
15)
16)
17) 18)

Once/Operating Cycle Once every 30 Revision 46 Amendment No. 42, 93, 4 3uilding Vent Radiation Monitor Containm Containm Reactor E Main Sta Turbine E

0' 3/4.2-38

/

NOTES FOR TABLES 4.2.A THROUGH 4.2.G

1.

Initially once per month until exposure hours (M as defined on Figure 4.1.1) is 2.0 x 105; thereafter, according to Figure 4.1.1 with an interval not less than one month nor more than three months.

SFunctional tests, calibrations and instrument checks are not required when Z:

these are not required to be operable or are tripped.

Functional

[

)

tests shall be performe--bef~r-e hn startup with a required frequency not to exceed once per week.

Calibrations o d SRMs shall be performed during each startup or during controlled shutdowns a required frequency not to exceed once per week.

Instrument checks shall be per d at least once per day during those periods when the instruments are required t operable.

3.

This instrumentation is excepted from the functional test definition.

The functional test will consist of injecting a simulated electrical signal into the measurement channel.

4.

Simulated automatic actuation shall be performed once each operating cycle.

Where possible, all logic system functional tests will be performed using the test jacks.

5.

Reactor low water level and high drywell pressure are not included on Table 4.2.A since they are tested on Tables 4.1.1 and 4.1.2.

6.

The logic system functional tests shall include a calibration of time delay relays and timers necessary for proper functioning of the trip systems.

7.

Calibration of analog trip units will be performed concurrent with functional testing.

The functional test will consist of injecting a simulated electrical signal into the measurement channel.

Calibration of associated analog transmitters will be performed each refueling outage.

Revision 4-7 Amendment No. 42;-99;-10-1477-I14 3/4.2-41

LIMITING CONDITIONS FOR OPERATION CONTAINMENT SYSTEMS (Cont)

Primarv Containment (Cont)

7.

Containment Atmosphere Dilution 4.7 CONTAINMENT SYSTEMS (Cont)

A.

Primary Containment (Cont)

7.

Containment Atmosphere Dilution

a. Within the 24-hour period after placing the reactor in the Run Mode the Post-LOCA Containment Atmosphere Dilution System must be operable and capable of supplying nitrogen to the containment for atmosphere dilution.

If this specification cannot be met, the system must be restored to an operable condition within 30 days or the reactor must be at least in Hot Shutdown within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

b. Within the 24-hour period after placing the reactor in the Run Mode, the Nitrogen Storage Tank shall contain a minimum of 1500 gallons of liquid N2.

If this specification cannot be met the minimum volume will be restored within 30 days or the reactor must be in at least Hot Shutdown within 12

a.

The post-LOCA containment atmosphere dilution system shall be functionally tested once per operating cycle.

b. The level in the liquid N2 storage tank shall be recorded weekly.

The H2 analyzers shall be tes or operability on(

per month a all be calibrated once per 6..onths

d. Once per month each manual or power operated valve in the CAD system flow path not locked, sealed or otherwise secured in position shall be observed and recorded to be in its correct position.

hours.

/c.

There-are 2 H2-and yzersk k*

available to serve the drywell.

.th only 1 H2 analyzer op able, reactor operation is al ed for up to 7 days.

If the in erable analyzer is not made ly operable within 7 days, reactor shall be in a least Shutdown within the next hours.

Revision 4; Amendment No.

3/4.7-10 3.7 A.

SURVEILLANCE REQUIREMENTS

LIMITING CONDITIONS FOR'OPERATION 3.7 CONTAINMENT SYSTEMS (Cont.)

no H2 analyzer operable, reactor

\\ope ratift"r4ýalowed for up to 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br />. If Sone of the ino-p-"abbe analyzers is not made Sfully operable within Bhorthe reactor S shall be in at least Hot Shutdo-Zrwi"th!he S *next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

B.

Standby Gas Treatment System and Control Room High Efficiency Air Filtration System

1. Standby Gas Treatment System
a. Except as specified in 3.7.B.1.c or 3.7.B.1.e below, both trains of the standby gas treatment shall be operable when in the Run, Startup, and Hot Shutdown MODES, during movement of irradiated fuel assemblies in the secondary containment, and during movement of new fuel over the spent fuel pool, and during CORE ALTERATIONS, and during operations with a potential for draining the reactor vessel (OPDRVs),

or the reactor shall be in cold shutdown within the next 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />.

b. 1. The results of the in-place cold DOP tests on HEPA filters shall show >99% DOP removal. The results of halogenated hydrocarbon tests on charcoal adsorber banks shall show

>99.9% halogenated hydrocarbon removal.

/

Revision 4 Amendment No. 15, 42, 50, 51, 52,412,144,51,5161, 170,48.7 3/4.7-11

)

SURVEILLANCE REQUIREMENTS 4.7 CONTAINMENT SYSTEMS (Cont.)

B.

Standby Gas Treatment System and Control Room High Efficiency Air Filtration System

1. Standby Gas Treatment System
a. 1. At least once per operating cycle, it shall be demonstrated that pressure drop across the combined high efficiency filters and charcoal adsorber banks is less than 8 inches of water at 4000 cfm.
2. At least once per operating cycle, demonstrate that the inlet heaters on each train are operable and are capable of an output of at least 14 kW.
3. The tests and analysis of Specification 3.7.B.1.b. shall be performed at least once per operating cycle or following painting, fire or chemical release in any ventilation zone communicating with the system while the system is operating that could contaminate the HEPA filters or charcoal adsorbers.
4. At least once per operating cycle, automatic initiation of

BASES:

3.2 PROTECTIVE INSTRUMENTATION (Cont)

Trip settings of < 100 mr/hr,for the monitors in the refueling area ventilation exhaust ducts are based upon initiating normal ventilation isolation and standby gas treatment system operation so that none of the activity released during the refueling accident leaves the Reactor Building via the normal ventilation path but rather all the activity Wirocessed by the standby gas treatment system.

For*-mcs-t-parameters monitored, as listed in Table 3.2.F, there are two (2) channels of instrumentation.

By comparing readings between these two (2)

channels, a near continuous surveillance of instrument performance is available.

Meaningful deviation in comparative readings of these instruments will initiate an early recalibration, thereby maintaining the quality of the SSI instrument readings.

e Safety -

Safety/Relief Valve position indication instrumentation provides t e operator-with--n--oa-t-n-on-sale*-em-4Lan--parameze-rntea" mnitnd ssess these variables during and following an accident In response to NUREG-0737, modifications were made to the ADS logic to extend automatic ADS operation to a class of transients that involve slowly uncovering the core without depressurizing the vessel or pressurizing the drywell.

These transients were analyzed assuming no high pressure injection systems (feedwater, HPCI or RCIC) are available.

Only ADS is considered available to depressurize the vessel, permitting operation of LPCI.

The transients generally involve pipe breaks outside containment.

Automatic ADS would not occur on low water level because high drywell pressure would not be present and ADS logic has a high drywell pressure permissive.

The modification added a timer to the ADS logic which bypasses the high drywell pressure permissive, and a manual inhibit switch which allows the operator to inhibit automatic ADS initiation for events where automatic initiation is not desirable.

An analysis was performed to determine an upper time limit on the bypass timer.

The goal was to ensure ADS is automatically initiated in time to prevent peak clad temperature (PCT) from exceeding 1500°F for a limiting break, which was determined to be a Reactor Water Cleanup line break.

The analysis concluded that there are 18 minutes between the low water level initiation of the timer and the heatup of the cladding to the limit.

Since the logic includes a 2 minute delay already, the bypass timer upper limit can not be more than 16 minutes, which provides a conservative margin for PCT and allows sufficient time for operator intervention if required.

A minimum time delay is incorporated to allow RPV water level to recover, resetting the timer and preventing depressurization.

The choice of a timer setting of 11 minutes places the setting in the middle and provides maximum tolerance from either limit.

(

Reference:

GE Report "Bypass Timer Calculation for the ADS/ECCS Modification for Pilgrim Station" December 16, 1986).

Revision +/--7 Amendment No.

89;-1337-44-91 B3/4.2-5

INSERT B3/4.2-5A The following are the instruments which meet the~quality requirements of Regulatory Guide 1.97 and can be credited to meet the operability requirements of Specificaiion 3/4.2.F. Two channels of indication in the control room from the below list must be available to,nmeet the Specification requirements.

Specification 314.2.F Function

1.

Reactor Water Level

2.

Reactor Pressure

3.

Drywell Temperature

4.

Neutron Monitoring Regulatory Guide 1.97 Instrurnjcr.tsc LI 263-100A, LI 263-106A, LR 1001-604A LI 263-1bOB, LI 263-106B, LR 10O1 i -60,eB LI 1001-650A, LI 1001-65CB PI 263-49A, PR-1001-600A PI 263-49B, PR-1001-600B TRU-9044, TI-901 9 APRM, SRM

5.

Suppression Chamber Water Temperature

6.

Suppression Chamber Bottom Pressure

7.

Suppression Chamber Water Level

8.

Drywell Pressure (Wide Range)

9.

Drywell Pressure (Narrow Range)

10.

Drywell High Radiation

11.

Containment H2 Analyzer TI 5021-02A, TRU-5021-01A TI 5022-02B, TRU-5022-01 B PI 1001-69A, PI 1001-69B PR 1001-69 LI 1001 604A, LR 1001-604A LI 1001 604B, LR 1001-604B PI-1001-600A, PR-1001-600A PI-1001-600B, PR-1001-600B PI-1001-601A, PR-1001-600A PI-1001-601B, PR-1001-600B RIT-1001-606A, RR 1001-606A RIT-1001-606B, RR 1001-606B AI-1-5184A, AR 1001-612A Al-1-5184B, AR 100 1-612B

BASES:

3/4.7 CONTAINMENT SYSTEMS (Cont)

A.

Primary Containment (Cont) wetwell pressure differential to keep the suppression chamber downcomer legs clear of watei significantly reduced suppression chamber post LOCA hydrodynamic loads.

A pressure of 1.17 psid is required to sufficiently clear the water legs of the downcomers without bubbling nitrogen into the suppression chamber at the 3.00 ft.

downcomer submergence which corresponds to approximately 84,000 ft.

3 of water.

Maximum downcomer submergence is 3.25 ft.

at operating suppression chamber water level.

The above pressure differential and submergence number are used in the Pilgrim I Plant Unique Analysis.

Post LOCA Atmosphere Dilution In order to ensure that the containment atmosphere remains inerted, i.e.

the oxygen-hydrogen mixture below the flammable limit, the capability to inject nitrogen into the containment after a LOCA is provided.

A minimum of 1500 gallons of liquid N2 in the storage tank assures that a three-day supply of N2 for post-LOCA containment inerting is available.

Since the inerting makeup system is continually functioning, no periodic testing of the system is required.

The Post-LOCA Containment Atmospheric Dilution (CAD)

System is designed to meet the requirements of AEC Regulatory Guides 1.3, 1.7 and 1.29, ASME Section

III, Class 2 (except for code stamping) and seismic Class I as defined in the PNPS FSAR.

In summary, the limiting criteria are:

1.

Maintain hydrogen concentration in the containment during post-LOCA conditions to less than 4%.

2.

Limit the buildup in the containment pressure due to nitrogen addition to less than 28 psig.

3.

To limit the offsite dose due to containment venting (for pressure control) to less than 300 Rem to the thyroid.

By maintaining at least a 3-day supply of N2 on site there will be sufficient time after the occurrence of a LOCA for obtaining additional nitrogen supply from local commercial sources.(1)

The system design contains sufficient redundancy to ensure its reliability.

Thus, it is sufficient to test the eahlety of the whole system once per operating cycle./The2 analyze-r

""illvidereunancy for the drywe~

1.e.

nere are two H2 analyzers for the Unit.

By e

g-4:e.ctor operation for 7 days with one of the two H2 analyzers inoperable, redundancy of analyzing c ill be maintained) while not imposing an immediate interruption in plant operation.

(1)

As listed in Pilgrim Nuclear Power Station Procedure No. 5.4.6 "Post Accident Venting".

Revision t-7-+/-

Amendment No.

557;-44 z

DJ/4.1-0

BASES:

3/4.7 CONTAINMENT SYSTEMS (Cont) testing of the analyzers using H2 will be adequate to ensure the system's readiness ecause of the design. Since the analyzers are normally not in operation there will be little de- *maer u t

s.

n rd.r..to.. e me e H~2 concentration, the analyzers must be warmed up 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> prior to putting into service. This im tablefor accident conditions because 004% H level will not b ahed in the drwell until 16 hour1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> the accident. Due to nitrogen addition, the pressure in the containment atera LOCA will increase wit time. Under the worst expected conditions the containment pressure will reach 28 psig in approximately 45 days. If and when that pressure is reached, venting from the containment shall be manually initiated per the requirements of 10CFR50.44.

The venting path will be through the Standby Gas Treatment system in order to minimize the off site dose.

B.1 Standby Gas Treatment System The Standby Gas Treatment System is designed to filter and exhaust the reactor building atmosphere to the stack during secondary containment isolation conditions. Upon containment isolation, both standby gas treatment fans are designed to start to bring the reactor building pressure negative so that all leakage should be in leakage. After a preset time delay, the standby fan automatically shuts down so the reactor building pressure is maintained approximately 1/4 inch of water negative. Should one system fail to start, the redundant system is designed to start automatically. Each of the two trains has 100%

capacity.

High Efficiency Particulate Air (HEPA) filters are installed before and after the charcoal adsorbers to minimize potential release of particulates to the environment and to prevent clogging of the iodine adsorbers. The charcoal adsorbers are installed to reduce the potential release of radioiodine to the environment. The in-place test results should indicate a system leak tightness of less than 0.1% bypass leakage for the charcoal adsorbers and a HEPA filter efficiency of at least 99% removal of cold DOP particulates.

The laboratory carbon sample test results should indicate a methyl iodide removal efficiency of at least 97.5% for expected accident conditions. The specified efficiencies for the charcoal and particulate filters is sufficient to preclude exceeding 1nCFR100 guidelines for the accidents analyzed. The analysis of the loss of coolant accident assumed a charcoal adsorber efficiency of 95% and TID 14844 fission product source terms, hence, installing two banks of adsorbers and filters in each train provides adequate margin. A 14 kW heater maintains relative humidity below 70% in order to ensure the efficient removal of methyl iodide on the impregnated charcoal adsorbers. Considering the relative simplicity of the heating circuit,cthe test frequency of once/operating cycle is adequate to demonstrate operability.

Air flow through the filters and charcoal adsorbers for 15 minutes each month assures rperability of the system. Since the system heaters are automatically controlled, the air flowing through the filters and adsorbers will be <70% relative humidity and will have the desired drying effect.

Revision T 8" Amendment No. 42, 143,54-.,,-8-7 B3/4.7-9

ATTACHMENT 2 LIST OF REGULATORY COMMITMENTS

List of Regulatory Commitments The following table identified those actionq committed to by Pilgrim in this document. Any other statements in this submittal are provided for information purposes and are not considered to be regulatory commitments.

REGULATORY COMMITMENT DUE DATE Implement changes to the Technical 60 days following approval of the Specifications within 60 days of approval, amendment.