July 2002 Monthly Operating Report for Nine Mile Point Unit 2
ML022380032
Person / Time
Site: Nine Mile Point 
Issue date: 08/06/2002
From: Peckham M
Constellation Generation Group
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NMP2L 2069
Download: ML022380032 (4)


Text

P.O. Box 63 Lycoming, New York 13093 Constellation Generation CkoW Nine Mile Point Nuclear Station August 6, 2002, NMP2L 2069 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 RE:

Subject:

Nine Mile Point Unit 2 Docket No. 50-410 NPF-69 Monthly Operating Report for July 2002 Gentlemen:

Submitted herewith is the Operating Data Report, the Unit Shutdowns, and Summary of Operating Experience for July, 2002.

Very truly yours, Michael F. Peckham Unit 2 Plant General Manager MFP/jm Attachments cc:

Mr. H. J. Miller, NRC Regional Administrator, Region I Mr. G. K. Hunegs, NRC Senior Resident Inspector Records Management

NIAGARA MOHAWK POWER CORPORATION NINE MILE POINT NUCLEAR STATION UNIT #2

SUMMARY

OF OPERATING EXPERIENCE Nine Mile Point Unit Two operated with a capacity factor (MDC) of 101.2% and an availability factor of 100% for the month of July, 2002.

On July 27, 2002, at 0730 hours0.00845 days <br />0.203 hours <br />0.00121 weeks <br />2.77765e-4 months <br />, a planned power reduction was initiated to support repair of minor leaks in the second point feedwater heater drain line. A Furmanite leak repair was performed while the unit was maintained at approximately 76% power. Following satisfactory completion of the leak repair, full power operation was resumed on July 27, 2002 at 2115 hours0.0245 days <br />0.588 hours <br />0.0035 weeks <br />8.047575e-4 months <br />.

There were no challenges to the safety relief valves during this reporting period.

OPERATING DATA REPORT DOCKET NO.

DATE:

COMPLETED BY:

TELEPHONE:

50410 08/01/2002 T. P. McMahon (315) 3494045 OPERATING STATUS Unit Name:

Reporting Period.

1. Design Electrical Rating (MWe)
2. Maximum Dependable Capacity (Net MWe)
3. Number of Hours Reactor was Critical:
4. Hours Generator On-Line:
5. Reactor Reserve Shutdown Hours:
6. Net Electrical Energy Gen. (MWH)

Nine Mile Point Unit #2 July 2002 1,143.3 1,119.8 This Month 744.0 744.0 0.0 843,097.0 Yr-to-Date 4,363.2 4,311.1 0.0 4,885,488.9 Cummulative 99,566.5 96,692.0 0.0 100,943,821.6

UNIT SHUTDOWNS APPENDIX B REPORTING PERIOD - JULY 2002 Reason:

A-Equipment Failure (Explain)

B-Maintenance or Test C-Refueling D-Regulatory Restriction E-Operator Training & License Exam F-Administrative G-Operational Error (Explain)

H-Other (Explain)

DOCKET NO: 50-410 UNIT NAME: NMP#2 DATE: 08/01/02 Prepared by: T. McMahon TELEPHONE: (315) 349-4045 Method:

1-Manual 2-Manual Trip/Scram 3-Automatic Trip/Scram 4-Continuation 5-Other (Explain)