Virginia Electric and Power Co., (Dominion) North Anna Power Station Unit 2 Final Inservice Inspection Summary Report
ML022190627
Person / Time
Site: North Anna 
(NPF-007)
Issue date: 07/30/2002
From: Hartz L
Virginia Electric & Power Co (VEPCO)
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
02-467, NLOS/ETS
Download: ML022190627 (15)


Text

VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 July 30, 2002 U.S. Nuclear Regulatory Commission Serial No.:

02-467 Attention: Document Control Desk NLOS/ETS Washington, D.C. 20555 Docket No.:

50-339 License No.:

NPF-7 Gentlemen:

VIRGINIA ELECTRIC AND POWER COMPANY (DOMINION)

NORTH ANNA POWER STATION UNIT 2 FINAL INSERVICE INSPECTION

SUMMARY

REPORT As set forth in the provisions of ASME Section XI, Paragraph IWA-6230, attached is the final Inservice Inspection Summary Report for the second quarter inservice inspection interval of North Anna Power Station Unit 2. This report provides a summary of the examinations performed between the Spring 2001 refueling outage and the end of the interval.

In accordance with IWA-6220 of ASME Section XI, the attachment to this letter includes a NIS-1 Form, "Owner's Report for Inservice Inspections," an examination summary, abstracts of examinations performed, and NIS-2 Forms, "Owner's Report for Repairs or Replacements."

The entire report will be maintained on file at the corporate office.

If you have any questions or require additional information, please contact us.

Very truly yours, Leslie N. Hartz Vice President - Nuclear Engineering Attachment Commitments made in this letter: None Aoy/

cc:

U.S. Nuclear Regulatory Commission Region II Sam Nunn Atlanta Federal Center 61 Forsyth Street, SW Suite 23T85 Atlanta, Georgia 30303-8931 Mr. M. J. Morgan NRC Senior Resident Inspector North Anna Power Station Mr. M. Grace Authorized Nuclear Inspector North Anna Power Station Mr. J. E. Reasor, Jr.

Old Dominion Electric Cooperative Innsbrook Corporate Center 4201 Dominion Blvd.

Suite 300 Glen Allen, Virginia 23060

Attachment Final Inservice Inspection Summary Report North Anna Power Station Unit 2 P.O. Box 402 Mineral, Virginia 23117 Owner's Report Of Inservice Inspections For Interval 2 Commercial Service Date 12-14-80 Virginia Electric and Power Company 5000 Dominion Boulevard Glen Allen, Virginia 23060

Attachment SN 02-467 Page* 1 of 12 Examination Summary Virginia Electric and Power Company North Anna Power Station Unit 2 2 nd Interval, 3rd Period System Pressure Tests This report covers two System Pressure Tests that were conducted at North Anna Power Station Unit 2 on October 21, 2001 and October 27, 2001. These System Pressure Tests were performed beyond start up due to scheduling. The tests were conducted to meet the requirements of ASME Section Xl, 1986 Edition, of the ASME Boiler and Pressure Vessel Code.

Test procedures were approved prior to signing the final documentation. Certification documents relative to personnel, equipment, and materials were reviewed and determined to be satisfactory.

Personnel from the Hartford Steam Boiler Inspection and Insurance Company of Connecticut, One State Street, Hartford, Connecticut 06102 (Mr. Mark Grace), and North Anna technical staff conducted inspections, witnessing and surveillance of the tests.

Abstract of Examination Performed System Pressure Test Program Zone Number 12050-SPM-095B-1-5 12050-SPM-095B-1-3 12050-SPM-070B-1-1 12050-SPM-070B-2-1 12050-SPM-070B-3-1 SPT Number Description 2-FC-001 Makeup lines to the Spent Fuel Pool 2-CH-001 Makeup lines to the RWST and Spent Fuel Pool 2-MS-001 Main Steam outside containment from A Steam Generator 2-MS-001 Main steam outside containment from B Steam Generator 2-MS-001 Main steam outside containment from C Steam Generator ASME Category Item Class Number 2

D-C D3.10 2

C-H C7.40 C7.80 2

C-H C7.80 C7.40 2

C-H C7.40 C7.80 2

C-H C7.40 C7.80 Completion 10/21/01 10/21/01 10/27/01 10/27/01 10/27/01

Attachment SN 02-467 Page 2 of 12 Intentionally left blank

Attachment SN 02-467 Page 3 of 12 FORM NIS-1 OWNERS' REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1. Owner Virginia Electric & Power Company, 5000 Dominion Boulevard, Glen Allen, VA. 23060 (Name and Address of Owner)
2. Plant North Anna Power Station, P. 0. Box 402, Mineral, VA. 23117 (Name and Address of Plant)
3. Plant Unit 2
4. Owner Certificate of Authorization (if required) N/A
5. Commercial Service Date 12/14/80
6. National Board Number for Unit N/A
7. Components Inspected Component or Manufacturer Manufacturer State or National Appurtenance or Installer or Installer Serial No.

Province No.

Board No.

Class 2 Piping Stone & Webster N/A N/A N/A Nonserialized Engineering Corp.

Reactor Vessel RDM Rotterdam 30662 VA61445 N/A 2-RC-R-1

.4.

4 4

.4.

4

4.

1 1-1 1

L

-4.

+

+

+

t

1

t t

T 4

4 4

4 4

4 I.

4 4

4 4

1 1

J J

Note: Supplemental sheets in form of lists, sketches, or drawings may be used provided (1) size is 8'/, in. X 11 in.,

(2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Attachment SN 02-467 Page 4 of 12 FORIM NIS-1 (back)

8.

Examination Dates 4/9/01 to 12/13/01

9.

Inspection Period Identification Third Period (12/14/97 to 12/13/01)

10. Inspection Interval Identification Second Interval (12/14/90 to 12/13/01
11. Applicable Edition of Section XI 1986 Addenda None
12. Date/Revision of Inspection Plan July 7, 2002 (Revision 5 - Change 12)
13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for Inspection Plan.

See Attachment 14 Abstract of Results of Examinations and Tests.

None

15. Abstract of Corrective Measures.

None We certify that a) the statements made in this report are correct b) the examinations and tests meet the Inspection Plan as required by ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. (if applicable) N/A Date May 14, 2002 Signed Virginia Electric & Power Co.

By Owner Expiration Date NIA4 Date July 15,2002 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Viginia and employed by HSB-CT of Hartford, CT have inspected the components described in this Owners' Data Report during the period 4/9/01 to 12/13/01, and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, and tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__Commissions VA 424-R Inspector's Signature National Board, State, Province and Endorsements

Attachment SN 02-467 Page 5 o' 12 Repair and Replacements Repairs and replacements completed since the Spring 2001 refueling outage were performed in accordance with Section Xl of the ASME Boiler and Pressure Vessel Code, 1986 Edition.

The following paragraphs and the attached NIS-2 forms represent those repairs and replacements performed on Class 1 and 2 systems.

RR# 2001-256 Rev. 3, Repaired Reactor Vessel CRDM penetration 63 by excavating flaws, performing tempered bead repair and using embedded flaw repair technique. This repair was performed under Work Order 459825 -01 & 09, and completed on 12/7/01.

RR# 2001-260 Rev. 1, Repaired Reactor Vessel CRDM penetration 62 after obtaining boat sample by performing tempered bead repair and using embedded flaw repair technique. The repair was performed under Work Order 457775-09 and 13, and was completed on 12/7/01.

RR# 2001-261, Repaired Reactor Vessel CRDM penetration 51 by performing a weld overlay repair. This repair was performed under Work Order 457775-09, and was completed on 12/7/01.

Statement of Interval Status Virginia Electric and Power Company has completed 100 percent of the third period system pressure test examinations and 100 percent of the second interval system pressure test examinations.

Attachment SN 02-467 Page 6 of 12 Intentionally left blank

Attachment SN 02-467 Page 7-of 12 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Virginia Electric & Power Company Name 5000 Dominion Blvd., Glen Allen, VA 23060 Address
2. Plant North Anna Power Station Name P.O. Box 402, Mineral, VA 23117 Address
3. Work Performed By Virginia Electric & Power Company Name 5000 Dominion Blvd., Glen Allen. VA 23060 Date January 10, 2002 Sheet 1

of 1

Unit:

2 41W 1,1

-i" R/R 2001-256 Work Order 459825-01 & 09 Repair O(rganization P.O. No. Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date N/A Address

4. Identification of System Reactor Coolant, Class 1
5.

(a) Applicable Construction Code ASME III 1968 Edition, winter 69 Addenda, Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1992 w 92 Add.

6.

Identification of Components Repaired or Replaced and Replacement Components ASME Code National

Repaired, Stamped Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No)

Unit 2 Reactor Rotterdam 30662 N/A 2-RC-R-1 1972 Repair No Vessel (Pent. 63)

7. Description of Work Excavated indications, performed tempered bead repair and then performed embedded flaw repair of penetration 63.
8. Tests Conducted: Hydrostatic[] Pneumatic E]

Nominal Operating Pressure X 0 OtheC]

Pressure 2235 psi Test Temp. 547 OF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8'/z in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017

Attachment SN 02-467 Page 8 of 12 FORM NIS-2 (Back)

9. Remarks Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and thisrepair conforms to the rules of the ASME Code,Section XI.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization 0~o.

N/A Expiration Date NZ/A Signed i

ISI Engineer Date _ ________

2002.

Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Virginia and employed by 11S5B C

of

Hartford, CT have insp cted the components described in this Owner's Report during the period

/

/! /

to

/ /Z XiOL

,- and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

4*7','*

s1-Z Commissions VA424-R Inspector's Signature National Board. State, Province, and Endorsements RX 2002 natp.

Attachment SN 02-467 Page 9 of 12 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Virginia Electric & Power Company Name 5000 Dominion Blvd., Glen Allen, VA 23060 Address
2. Plant North Anna Power Station Name P.O. Box 402, Mineral, VA 23117 Address
3. Work Performed By Virginia Electric & Power Company Name 5000 Dominion Blvd., Glen Allen, VA 23060 Address
4. Identification of System _Reactor Coolant, Class 1 Date January 10, 2002 Sheet 1

of Unit:

2 P,-

,1' R/R 2001-260_Work Order 457775-09 & 13 Repair Oiganization P.O. No. Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date N/A

5.

(a) Applicable Construction Code ASME 111 196.8 Edition, winter 69 Addenda, (b) ApplicableEdition of Section XI Utilized for Repairs or Replacements 1992 w 92 Add.

6.

Identification of Components Repaired or Replaced and Replacement Components Code Case ASME Code National

Repaired, Stamped Name of Name of Manufacturer Board Other Year Replaced.

(Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No)

Unit 2 Reactor Rotterdam 30662 N/A 2-RC-R-1 1972 Repair No Vessel (Pent. 62)

7. Description of Work Obtained boat sample, performed tempered bead repair of excavation & then performed embedded flaw repair of penetration 62.
8. Tests Conducted: Hydrostaticl-Pneumatic E]

Nominal Operating Pressure J1 Othelrl Pressure

- ".1 -2 t-i T-*f T.,-

fl7 NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used. provided (1) size is 811, in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017

.. (12/82)

FORM NIS-2 (Back)

Co ke CO.-s 5-JI-1Ilý I

Applicable Manufacturer's Data Reports to be attached 9 Remarks CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and thisrepair conforms to the rules of the ASME Code,Section X I.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed ISI Engineer Date__________

206,2 Owner or Owner's Des3gnee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectorseand the State or Province of Virginia and employed by HSP, -C*'

of

Hartford, CT have in spect I the components described in this Owner's Report during the period

/

0to_

t Z"

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

S, w

p.

-Commissions VA424-R Inspector's Signature National Board, State, Province, and Endorsements flati.

+w' ?nng2O~

I

  • O Attachment SN 02-467 Page 10 of 12

Attachment SN 02-467 Page II of 12 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Virginia Electric & Power Company Name 5000 Dominion Blvd., Glen Allen, VA 23060 Address
2. Plant North Anna Power Station Name P.O. Box 402, Mineral, VA 23117 Address
3. Work Performed By Virginia Electric & Power Company Name 5000 Dominion Blvd.. (Gln AIllen VA *3OR(

Date January 9, 2002 Sheet 1

of 1

Unit:

2 R/R 2001-261 Work Order 457775-09 Repair Organization P.O. No. Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Exoiration Date N/A Address

4. Identificaiion of System _Reactor Coolant, Class 1
5.

(a) Applicable Construction Code ASME III 1968 Edition, winter 69 Addenda, (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1992 w 92 Add.

6.

Identification of Components Repaired or Replaced and Replacement Components Code Case ASME Code National Repaired.

Stamped Name of Name of Manufacturer Board Other Year

Replaced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Replacement or No)

Unit 2 Reactor Rotterdam 30662 N/A 2-RC-R 1972 Repair No Vessel (Pent. 51)

7. Description of Work Performed a weld overlay repair to CRDM penetration #51 on the Reactor Head
8. Tests Conducted:

Hydrostatic[] Pneumatic []

Nominal Operating Pressure El OtheiC]

Pressure _psi Test Temp.

OF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017 5000 Dominion Blvd Glen Allen VA 23060

  • 1 FORM NIS-2 (Back)
9. Remarks Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and thisrepair conforms to the rules of the ASME Code,Section XI.

repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No.

N A Expiration Date N/A Signed IeC T

7 ISl Engineer Date I

)- [

2002, Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Virginia and employed by HSP" -Cr of
Hartford, CT

-have igspectyd the components described in this Owner's Report during the period 4to j/'j Z-'/

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

,oy" Commissions VA424-R Inspector's Signature National Board. State, Province, and Endorsements Attachment SN 02-467 Page 12 of 12