U-603568, June 2002 Monthly Operating Report for Clinton Power Station

From kanterella
(Redirected from ML022000337)
Jump to navigation Jump to search
June 2002 Monthly Operating Report for Clinton Power Station
ML022000337
Person / Time
Site: Clinton 
Issue date: 07/11/2002
From: Iliff W
AmerGen Energy Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
U-603568
Download: ML022000337 (5)


Text

AmerGen An Exelon/British Energy Company Clinton Power Station R.R. 3 Box 228 Clinton, IL 61727-9351 10CFR50.36 U-603568 July 11, 2002 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Clinton Power Station Facility Operating License No. NPF-62 NRC Docket No. 50-461

Subject:

June 2002 Monthly Operating Report Please find in Attachment 1 the Monthly Operating Report for Clinton Power Station, Unit 1, for the period ending June 30, 2002.

Respectfully, W.

W. S. IlIf Regulatory Assurance Manager Clinton Power Station MJS/blf Attachments cc:

Regional Administrator - NRC Region III NRC Senior Resident Inspector - Clinton Power Station Office of Nuclear Facility Safety - Illinois Department of Nuclear Safety

" ý' ý

ý")2' ý +

ATTACHMENT 1 CHALLENGES TO MAIN STEAM SAFETY/RELIEF VALVES Month June 2002 None

ATTACHMENT 2 AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.

UNIT DATE COMPLETED BY TELEPHONE 50-461 Clinton 1 06/30/02 M. J. Sloan (217)937-3280 June 2002 17 18 19 20 21 22 23 24 25 26 27 28 29 30 1034 1023 1025 1026 1026 1026 1027 1025 1025 1027 1028 1031 1030 1029 MONTH 1013 1014 1

2 3

4 5

6 7

8 9

10 11 12 13 14 15 16 1012 1010 1012 1013 1013 1012 1013 1011 1012 1014 1016 1018 1020 1011

ATTACHMENT 3 OPERATING DATA REPORT DOCKET NO.

50-461 UNIT Clinton 1 DATE 06/30/02 COMPLETED BY TELEPHONE M. J. Sloan (217)937-3280 OPERATING STATUS

1.

REPORTING PERIOD:

June 2002 GROSS HOURS IN REPORT PERIOD: 720

2.

CURRENTLY AUTHORIZED POWER LEVEL (MWt):

3473 MAX. DEPEND. CAPACITY (MDC) (MWe-Net):

1022 DESIGN ELECTRICAL RATING (MWe-Gross):

1062

3.

POWER LEVEL TO WHICH RESTRICTED (IF ANY) (MWe-Net):

None

4.

REASONS FOR RESTRICTION (IF ANY):

N/A NUMBER OF HOURS REACTOR WAS CRITICAL REACTOR RESERVE SHUTDOWN HOURS HOURS GENERATOR ON LINE UNIT RESERVE SHUTDOWN HOURS GROSS THERMAL ENERGY GENERATED (MWH)

GROSS ELECTRICAL ENERGY GENERATED (MWH)

NET ELECTRICAL ENERGY GENERATED (MWH)

REACTOR SERVICE FACTOR REACTOR AVAILABILITY FACTOR UNIT SERVICE FACTOR UNIT AVAILABILITY FACTOR UNIT CAPACITY FACTOR (Using MDC)

UNIT CAPACITY FACTOR (Using Design MWe)

UNIT FORCED OUTAGE RATE THIS MONTH 720.0 0.0 720.0 0.0 2,336,265.0 764,434.0 734,215 100.0%

100.0%

100.0%

100.0%

109.6%

100.3%

0.0%

YR TO DATE CUMULATIVE 3534.4 0.0 3429.3 0.0 10,094,633 3,335,794.0 3,192,997.3 81.4%

81.4%

78.9%

78.9%

79.0%

77.6%

2.1%

84,345.6 0.0 82,213.0 4.0 225,611,972.6 74,781,424 71,360,435 65.9%

65.9%

64.2%

64.2%

60.0%

54.8%

7.1%

19.

SHUTDOWNS SCHEDULED OVER NEXT SIX MONTHS (TYPE, DATE, DURATION OF EACH):

TYPE DATE DURATION NONE

20.

IF SHUT DOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP:

N/A

5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.

18.

ATTACHMENT 4 UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO.

UNIT DATE REPORT MONTH June 2002 TYPE FORCED NO.

DATE F:

SCHEDULED DURATION (HOURS)

REASON (1)

COMPLETED BY METHOD OF SHUTTING DOWN THE REACTOR OR REDUCING POWER (2) 50-461 Clinton 1 06/30/02 M. J. Sloan CORRECTIVE ACTIONS/COMMENTS NONE (1)

Reason A - Equipment Failure (explain), B - Maintenance or Test, C - Refueling, D - Regulatory Restriction E - Operator training & License Examination, F - Administrative, G - Operational Error (explain)

(2)

Method 1 - Manual, 2 - Manual Scram, 3 - Automatic Scram, 4 - Other (explain)