ML021710130
| ML021710130 | |
| Person / Time | |
|---|---|
| Site: | Vermont Yankee File:NorthStar Vermont Yankee icon.png |
| Issue date: | 06/10/2002 |
| From: | Bronson K Vermont Yankee |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| BVY-02-39 | |
| Download: ML021710130 (6) | |
Text
VERMONT YANKEE NUCLEAR POWER STATION P.O. Box 157, Governor Hunt Road Vernon, Vermont 05354-0157 (802) 257-7711 June 10, 2002 BVY-02-39 United States Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555
Reference:
(a) License No. DPR-28 (Docket No. 50-271)
In accordance with section 6.6.B of the Vermont Yankee Technical Specifications, submitted herewith is the Monthly Statistical Report for the Vermont Yankee Nuclear Power Station for the month of May, 2002.
Sincerely, VERMOY YANKEE NUCLEAR POWER STATION Kevin H. Bronson Plant Manager cc: USNRC Region I Administrator USNRC Resident Inspector - VYNPS USNRC Project Manager - VYNPS
VERMONT YANKEE NUCLEAR POWER STATION MONTHLY STATISTICAL REPORT 02-05 FOR THE MONTH OF MAY 2002
OPERATING DATA REPORT DOCKET NO.50-271 DATE 020610 COMPLETED BY G.A. WALLIN TELEPHONE (802)258-5414 OPERATING STATUS
- 1. Unit Name:
Vermont Yankee
- 2. Reporting Period:
May
- 3. Licensed Thermal Power(MWt):1593
- 4. Nameplate Rating(Gross MWe): 540
- 5. Design Electrical Rating(Net MWe):
522
- 6. Maximum Dependable Capacity(Gross MWe):
535
- 7. Maximum Dependable Capacity(Net MWe):
510
- 8. If changes, occur in capacity ratings(Items Number 3 through 7) since last report, give reasons:
- 9.
Power level to which restricted, if any(Net MWe):
N/A
- 10. Reasons for restrictions, if any:
N/A This Month Yr-to-Date Cumulative
- 11. Hours in Reporting Period 744.00 3623.00 257831.00
- 12. Number Of Hours Reactor was Critical 487.88 3366.88 218482.30
- 13. Reactor Reserve Shutdown Hours 0.00 0.00 0.00
- 14. Hours Generator On-Line 460.70 3339.70 214886.14
- 15. Unit Reserve Shutdown Hours 0.00 0.00 0.00
- 16. Gross Thermal Energy Generated(MWH) 645131.15 4958251.70 325148335.91
- 17. Gross Electrical Energy Generated(MWH) 219181.00 1700969.00 109130558.00
- 18. Net Electrical Energy Generated(MWH) 209953.00 1633782.00 103853525.00
- 19. Unit Service Factor 61.90 92.20 82.30
- 20. Unit Availability Factor 61.90 92.20 82.30
- 21. Unit Capacity Factor(Using MDC Net) 55.30 88.40 78.70
- 22. Unit Capacity Factor(Using DER Net) 54.10 86.40 77.10
- 23. Unit Forced Outage Rate 0.00 0.00 4.02
- 24. Shutdowns scheduled over next 6 months(Type, Date, and Duration of Each:
- 25.
If shut down at end of report period, estimated date of startup: N/A
- 26. Units In Test Status(prior to commercial operation): N/A Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION VYDPF 0411.01 (Sample)
DP 0411 Rev.
7 Page 1 of 1 RT No.
13.F01.19F
AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.
50-271 UNIT Vermont Yankee DATE 020610 COMPLETED BY G.A. WALLIN TELEPHONE (802)258-5414 MONTH May DAY AVERAGE DAILY POWER LEVEL (MWe-Net) 1.
- 2.
- 3.
- 4.
- 5.
6.
7.
476 476 476 476 476 458 474 474
- 8.
9.
- 10.
- 11.
- 12.
- 13.
- 14.
- 15.
16.
474 474 222 0
0 0
0 0
DAY AVERAGE DAILY POWER LEVEL (MWe-Net)
- 17.
- 18.
- 19.
- 20.
- 21.
- 22.
- 23.
- 24.
- 25.
- 26.
- 27.
- 28.
- 29.
- 30.
31.
0 0
0 0
0 0
93 312 430 419 481 524 524 525 524 INSTRUCTIONS:
On this format, list the average daily unit power level in MWE-Net for each day in the reporting month.
Compute to the nearest whole megawatt.
VYDPF 0411.02 (Sample)
DP 0411 Rev.
7 Page 1 of 1 RT No.
13.F01.18V
UNIT SHUTDOWNS AND POWER REDUCTIONS REPORT MONTH MAY 1
F: Forced S: Scheduled VYDPF 0411.03 DP 0411 Rev.
7 Page 1 of 1 DOCKET NO UNIT NAME DATE COMPLETED BY TELEPHONE 2 Reason:
3 Method:
A-Equipment Failure (Explain) 1 -
Manual B-Maintenance or Test 2 - Manual Scram C-Refueling 3 - Automatic Scram D-Regulatory Restriction 4 - Other (Explain)
E-Operator Training and License Examination F-Administrative G-Operational Error (Explain)
H-(Explain) -
Rod pattern exchange 50-271 Vermont Yankee 020610 G.A. Wallin (802)258-5414 4 Exhibit G-Instructions for Preparation of Data Entry Sheets for License Event Report (LER) File (NUREG 0161) 5 Exhibit I -
Same Source 1
2 3
4 5
No.
Date Type Duration Reason Method of License System Component Cause and Corrective (hours)
Shutting Event Code Code Action to Prevent Down Report #
Recurrence Reactor 02-09 020511 5
283.30 B,C 1
N/A RB CONROD Shutdown for Mid-Cycle Refueling outage 02-10 020526 S
0.00 H
4 N/A RB CONROD Rod pattern adjustment Power Reduction
DOCKET NO.
50-271 DATE 020610 COMPLETED BY G.A. WALLIN TELEPHONE (802)258-5414 REPORT MONTH May
SUMMARY
OF OPERATING EXPERIENCES Highlights Vermont Yankee operated at 54.4 of rated thermal power for the month.
Gross electrical generation was 219,181 MWHe or 53.9% design electrical capacity.
Operating Summary The following is a chronological description of plant operations including other pertinent items of interest for the month:
At the beginning of the reporting period the plant was operating at 90.9%
of rated thermal power.
020511 At 0807 hours0.00934 days <br />0.224 hours <br />0.00133 weeks <br />3.070635e-4 months <br />, commenced a plant shutdown for a mid-cycle refueling.
See Unit Shutdowns and Power Reductions) 020511 At 1522 hours0.0176 days <br />0.423 hours <br />0.00252 weeks <br />5.79121e-4 months <br />, the turbine-generator was removed from the grid.
020511 At 2326 hours0.0269 days <br />0.646 hours <br />0.00385 weeks <br />8.85043e-4 months <br />, the reactor was sub-critical.
020522 At 1533 hours0.0177 days <br />0.426 hours <br />0.00253 weeks <br />5.833065e-4 months <br />, the reactor was critical.
(See Unit Shutdowns and Power Reductions) 020523 At 1140 hours0.0132 days <br />0.317 hours <br />0.00188 weeks <br />4.3377e-4 months <br />, the turbine-generator was phased to the grid and began a return to full power.
020526 At 1000 hours0.0116 days <br />0.278 hours <br />0.00165 weeks <br />3.805e-4 months <br />, commenced a power reduction to 66% power for a rod pattern adjustment.
(See Unit Shutdowns and Power Reductions) 020526 At 1300 hours0.015 days <br />0.361 hours <br />0.00215 weeks <br />4.9465e-4 months <br />, began a return to full power following the rod pattern adjustment.
At the end of the reporting period the plant was operating at 99.9% of rated thermal power.
VYDPF 0411.04 (Sample)
DP 0411 Rev.
7 Page 1 of 1 RT No.
13.FO1.18X