ML021620144

From kanterella
Jump to navigation Jump to search
Constellation Nuclear, Nine Mile Point Unit 2 License NPF-69, Cycle 9 Core Operating License Report, Rev. 0
ML021620144
Person / Time
Site: Nine Mile Point 
(NPF-069)
Issue date: 05/23/2002
From: Montgomery B
Constellation Nuclear
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NMP2L 2059
Download: ML021620144 (24)


Text

P.O. Box 63 Lycoming, New York 13093 0

Constellation Nuclear Nine Mile Point Nuclear Station A Member of the May 23, 2002 Constellation Energy Group NMP2L 2059 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 RE:

Nine Mile Point Unit 2 Docket No. 50-410 NPF-69

Subject:

Cycle 9 Core Operating Limits Report,Revision 0 Gentlemen:

Attached is a copy of the Cycle 9 Core Operating Limits Report, Revision 0, for Nine Mile Point Unit 2 (NMP2). This report is being submitted pursuant to NMP2 Technical Specification 5.6.5.d.

Very truly yours, "l

fc aS., Mon gomery General Manager Nucl Engineering BSM/IAA/jm Attachment cc:

Mr. H.J. Miller, NRC Regional Administrator, Region I Mr. G.K. Hunegs, NRC Senior Resident Inspector Mr. P.S. Tam, Senior Project Manager, NRR (2 copies)

Records Management

ORIGINAL NINE MILE POINT UNIT 2 CORE OPERA TING LIMITS REPORT Document No.: COLR2-9 Revision 0, Cycle 9 Name CONTROLLED Date Prepared by:

15 2S 2d-2 C. LepineZ-Fuel Engineer Checked by:

Independently Reviewed by:

Approved by:

Approved by:

Approved by:

R. Bodily OF 1 E neer eP Ed)ann - Fuel Engineer M. Armenta - Supervisor, Fuels J. Darweesh - Supervisor, Reactor Engineering Engineering S rvices (N

A--

31 25-1.2

OL 3

2C/ol-3 A 5-!7ZO This Controlled Document provides cycle specific core operating limits for use in conjunction with the Nine Mile Point Unit 2 Technical Specifications. Document pages may only be changed through a reissue of the entire document.

. NINTE MILE POINT UNIT 2 COLR2-9, Revision 0 Cycle 9 CORE OPERA TING LIMITS REPORT Table of Contents Page 1.0 AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)................... 1 1.1 Limits for Technical Specification 3.2.1...............................................................

1 2.0 MINIMUM CRITICAL POWER RATIO (ODYN OPTION B)................................

10 2.1 Limits for Technical Specification 3.2.2...............................................................

10 3.0 LINEAR HEAT GENERATION RATE (LHGR).......................................................

14 3.1 Limits for Technical Specifications.3.2.3...............................

14 4.0 AVERAGE POWER RANGE MONITOR SETPOINTS............................................

16 4.1 Limits for Technical Specification Table 3.3.1.1-1 (OPRM Upscale).............. 16 5.0 ROD BLOCK MONITOR (RBM).....................................

17 5.1 Allowable Value for Technical Specification Table 3.3.2.1-1.............................

17

6.0 REFERENCES

FOR TECHNICAL SPECIFICATIONS...........................................

18

7.0 REFERENCES

FOR TECHNICAL SPECIFICATION BASES................................

19 8.0 SOURCE DOCUM ENTS...............................................................................................

20 Page i

- NINE MILE POINT UNIT 2 COLR2-9, Revision 0 Cycle 9 CORE OPERATING LIMITS REPORT 1.0 AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR) 1.1 Limits for Technical Specification 3.2.1 The APLHGR(s) for each type of fuel as a function of AVERAGE PLANAR EXPOSURE shall not exceed the limits shown in Tables la through 1g.

The limits of Tables 1 a through lh shall be reduced to a value of.78 times the two recirculation loop operation limit when in single recirculation loop operation.

NOTE:

When hand calculations are required, the APLHGR for fuel types P9CUB413, P9CUB414, P9CUB407-2382, P9CUB407-2383, P9CUB407-2503, P9CUB407-2502 and P9CUB404-2501 as a function of average planar exposure shall not exceed the limits shown in Table lh during two recirculation loop operation.

Page 1 of 21

NINE MILE POINT UNIT 2 COLR2-9, Revision 0 Cycle 9 Table la MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE Bundle Type: GEl 1-P9CUB413-12GZ-120T-146-T (GEl 1)

Average Planar Exposure, MAPLHGR Limits (kw/ft)

GWd/ST Lattice Lattice Lattice Lattice 2275 2545 2549 2274 0.00 12.78 11.43 11.45 13.38 0.20 12.72 11.46 11.49 13.35 1.00 12.55 11.53 11.57 13.26 2.00 12.49 11.61 11.68 13.23 3.00 12.49 11.69 11.78 13.24 4.00 12.52 11.77 11.89 13.27 5.00 12.55 11.86 12.01 13.29 6.00 12.58 11.94 12.12 13.32 7.00 12.60 12.03 12.24 13.34 8.00 12.63 12.11 12.36 13.35 9.00 12.64 12.20 12.48 13.36 10.00 12.65 12.29 1Z.60 13.37 12.50 12.51 12.26 12.65 13.33 15.00 12.12 12.11 12.44 12.94 17.50 11.72 11.90 12.13 12.54 20.00 11.33 11.61 11.80 12.15 25.00 10.62 11.08 11.09 11.36 30.00 10.13 10.75 10.44 10.88 35.00 9.65 10.29 9.96 10.40 40.00 9.18 9.82 9.52 9.93 45.00 8.71 9.40 9.14 9.46 50.00 8.24 8.99 8.80 9.00 54.96 7.78 55.00 8.62 8.48 8.53 58.06 8.41 58.32 8.22 58.66 8.30 NOTE: A indicates that there is no entry for this box and the limit can be determined by linearly interpolating between the previous and next point in each column. MAPLHGRs are interpolated between exposure points for which explicit values are given. The exposure for the last MAPLHUR listed for a lattice is the maximum allowed nodal exposure for that lattice.

Page 2 of 21

NINE MILE POINT UNIT 2 Table lb MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE Bundle Type: GEll-P9CUB414-13GZ-120T-146-T (GEll)

Average Planar Exposure, MAPLHGR Limits (kw/ft)

GWd/ST Lattice Lattice Lattice Lattice Lattice 2275 2545 2546 2547 2548 0.00 12.78 11.43 11.25 11.41 13.42 0.20 12.72 11.46 11.30 11.45 13.39 1.00 12.55 11.53 11.39 11.52 13.30 2.00 12.49 11.61 11.50 11.61 13.27 3.00 12.49 11.69 11.62 11.71 13.28 4.00 12.52 11.77 11.74 11.80 13.30 5.00 12.55 11.86 11.87 11.90 13.33 6.00 12.58 11.94 11.99 12.01 13.35 7.00 12.60 12.03 12.10 12.11 13.37 8.00 12.63 12.11 12.21 12.22 13.38 9.00 12.64 12.20 12.32 12.33 13.39 10.00 12.65 12.29 12.44 12.44 13.40 12.50 12.51 12.26 12.48 12.49 13.36 15.00 12.12 12.11 12.36 12.36 12.97 17.50 11.72 11.90 12.11 12.12 12.57 20.00 11.33 11.61 11.79 11.80 12.17 25.00 10.62 11.02 11.08 11.08 11.39 30.00 10.13 10.55 10.43 10.43 10.90 35.00 9.65 10.09 9.95 9.96 10.43 40.00 9.18 9.63 9.52 9.52 9.95 45.00 8.71 9.17 9.13 9.14 9.49 50.00 8.24 8.72 8.79 8.79 9.02 54.96 7.78 55.00 8.27 8.47 8.44 8.55 57.19 8.08

8.

58.28 8.17 58.42 8.23 58.58 8.30 NOTE: A "---' indicates that there is no entry for this box and the limit can be determined by linearly interpolating between the previous and next point in each column. MAPLHGRs are interpolated between exposure points for which explicit values are given. The exposure for the last MAPLHGR listed for a lattice is the maximum allowed nodal exposure for that lattice.

Page 3 of 21 COLR2-9, Revision 0 Cycle 9

NINE MILE POINT UNIT 2 Table 1c COLR2-9, Revision 0 Cycle 9 MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE Bundle Type: GE11-P9CUB407-14GZ-120T-146-T-2382 (GEl1)

Average Planar Exposure, MAPLHGR Limits (kw/ft)

GWd/ST Lattice Lattice Lattice Lattice Lattice 2887 2888 2889 2890 2891 0.00 12.76 10.97 11.19 11.10 13.38 0.20 12.69 11.02 11.23 11.14 13.35 1.00 12.52 11.10 11.30 11.23 13.26 2.00 12.46 11.19 11.39 11.33 13.23 3.00 12.46 11.29 11.48 11.44 13.24 4.00 12.49 11.38 11.57 11.54 13.27 5.00 12.52 11.48 11.66 11.64 13.29 6.00 12.55 11.58 11.75 11.75 13.32 7.00 12.58 11.69 11.84 11.86 13.34 8.00 12.60 11.79 11.93 11.97 13.36 9.00 12.62 11.90 12.03 12.09 13.37 10.00 12.63 12.00 12.13 12.21 13.37 12.50 12.48 11.96 12.10 12.25 13.33 15.00 12.09 11.84 11.98 12.17 12.94 17.50 11.70 11.71 11.80 11.96 12.54 20.00 11.30 11.49 11.52 11.65 12.14 25.00 10.59 11.01 11.01 11.10 11.36 30.00 10.10 10.68 10.68 10.54 10.87 35.00 9.62 10.35 10.36 10.07 10.40 40.00 9.15 9.89 9.92 9.63 9.93 45.00 8.68 9.46 9.49 9.24 9.46 50.00 8.21 9.07 9.07 8.87 8.99 54.80 7.77 55.00 8.66 8.67 8.53 8.52 57.55 8.48 57.64 8.48 57.97 8.36 58.26 8.22 NOTE: A indicates that there is no entry for this box and the limit can be determined by linearly interpolating between the previous and next point in each column. MAPLHGRs are interpolated between exposure points for which explicit values are given. The exposure for the last MAPLHGR listed for a lattice is the maximum allowed nodal exposure for that lattice.

Page 4 of 21

NINE MILE POINT UNIT 2 COLR2-9, Revision 0 Table ld Cycle 9 MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE Bundle Type: GE11-P9CUB407-14GZ-120T-146-T-2383 (GEl1)

Average Planar Exposure, MAPLHGR Limits (kw/ft)

GWd/ST Lattice Lattice Lattice Lattice Lattice 2887 2888 2892 2893 2891 0.00 12.76 10.97 11.03 10.93 13.38 0.20 12.69 11.02 11.08 10.98 13.35 1.00 12.52 11.10 11.17 11.08 13.26 2.00 12.46 11.19 11.28 11.21 13.23 3.00 12.46 11.29 11.40 11.35 13.24 4.00 12.49 11.38 11.51 11.49 13.27 5.00 12.52 11.48 11.63 11.62 13.29 6.00 12.55 11.58 11.74 11.74 13.32 7.00 12.58 11.69 11.84 11.86 13.34 8.00 12.60 11.79 11.94 11.98 13.36 9.00 12.62 11.90 12.03 12.10 13.37 10.00 12.63 12.00 12.13 12.22 13.37 12.50 12.48 11.96 12.10 12.26 13.33 15.00 12.09 11.84 11.98 12.17 12.94 17.50 11.70 11.71 11.79 11.95 12.54 20.00 11.30 11.49 11.51 11.65 12.14 25.00 10.59 11.01 11.01 11.10 11.36 30.00 10.10 10.68 10.68 10.54 10.87 35.00 9.62 10.35 10.36 10.07 10.40 40.00 9.15.

9.89 9.92 9.63 9.93 45.00 8.68 9.46 9.49 9.24 9.46 50.00 8.21 9.07 9.07 8.87 8.99 54.80 7.77 55.00 8.66 8.67 8.52 8.52 57.55 8.48 57.62 8.48 57.96 8.36 58.26 8.22 NOTE: A indicates that there is no entry for this box and the limit can be determined by linearly interpolating between the previous and next point in each column. MAPLHGRs are interpolated between exposure points for which explicit values are given. The exposure for the last MAPLHGR listed for a lattice is the maximum allowed nodal exposure for that lattice.

Page 5 of 21

NINE MILE POINT UNIT 2 COLR2-9, Revision 0

. Cycle 9 Table le MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE Bundle Type: GE11-P9CU1B404-12GZ-120T-146-T-2501 (GEl1)

Average Planar Exposure, MAPLHGR Limits (kw/ft)

GWd/ST Lattice Lattice Lattice Lattice Lattice 5230 5231 5232 5233 5234 0.00 12.76 11.12 11.14 10.93 13.36 0.20 12.69 11.17 11.19 11.00 13.33 1.00 12.52 11.26 11.29 11.13 13.24 2.00 12.46 11.39 11.42 11.32 13.21 3.00 12.46 11.54 11.57 11.53 13.22 4.00 12.49 11.66 11.69 11.74 13.25 5.00 12.52 11.73 11.77 11.87 13.27 6.00 12.55 11.80 11.85 11.98 13.30 7.00 12.58 11.88 11.93 12.09 13.32 8.00 12.60 11.96 12.02 12.19 13.34 9.00 12.62 12.04 12.10 12.29 13.35 10.00 12.63 12.12 12.18 12.40 13.36 12.50 12.48 12.05 12.14 12.44 13.31 15.00 12.09 11.89 11.98 12.24 12.92 17.50 11.70 11.73 11.77 11.94 12.53 20.00 11.30 11.47 11.48 11.61 12.13 25.00

  • 10.59 10.97 10.97 11.05 11.35 30.00 10.10 10.64 10.64 10.70 10.86 35.00 9.62 10.32 10.32 10.17 10.39 40.00 9.15 9.95 9.98 9.70 9.92 45.00 8.68 9.48 9.50 9.27 9.45 50.00 8.21 9.05 9.07 8.88 8.98 54.80 7.77 55.00 8.66 8.67 8.52 8.51 57.5 3 8.52 57.56 8.52 57.87 8.36 58.22 8.21 NOTE: A "---" indicates that there is no entry for this box and the limit can be determined by linearly interpolating between the previous and next point in each column. MAPLHGRs are interpolated between exposure points for which explicit values are given. The exposure for the last MAPLHGR listed for a lattice is the maximum allowed nodal exposure for that lattice.

Page 6 of 21

NINE MILE POINT UNIT 2 COLR2-9, Revision 0 Cycle 9 Table If MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE Bundle Type: GEl1-P9CUB407-14GZ-120T-146-T-2502 (GEl1)

Average Planar Exposure, MAPLHGR Limits (kw/ft)

GWd/ST Lattice Lattice Lattice Lattice Lattice 5230 5235 5236 5237 5238 0.00 12.76 10.98 11.19 11.10 13.38 0.20 12.69 11.03 11.23 11.15 13.35 1.00 12.52 11.10 11.30 11.23 13.26 2.00 12.46 11.19 11.39 11.33 13.23 3.00 12.46 11.29 11.48 11.44 13.24 4.00 12.49 11.38 11.57 11.54 13.27 5.00 12.52 11.48 11.66 11.64 13.29 6.00 12.55 11.58 11.75 11.75 13.32 7.00 12.58 11.68 11.84 11.86 13.34 8.00 12.60 11.79 11.93 11.97 13.36 9.00 12.62 11.89 12.03 12.09 13.37 10.00 12.63 12.00 12.12 12.21 13.37 12.50 12.48 11.96 12.10 12.25 13.33 15.00 12.09 11.83 11.97 12.16 12.94 17.50 11.70 11.71 11.79 11.95 12.54 20.00 11.30 11.49 11.51 11.65 12.14 25.00 10.59 11.01 11.00 11.10 11.36 30.00 10.10 10.68 10.68 10.54 10.87 35.00 9.62 10.36 10.35 10.07 10.40 40.00 9.15 9.89 9.93 9.63 9.93 45.00 8.68 9.46 9.49 9.24 9.46 50.00 8.21 9.07 9.07 8.87 8.99 5 4.8 0 7.7 7 55.00 8.66 8.67 8.53 8.52 57.53 8.48 8.48...

57.63 8.48 8.48 57.96 8.36 58.26 8.22 NOTE: A indicates that there is no entry for this box and the limit can be determined by linearly interpolating between the previous and next point in each column. MAPLHGRs are interpolated between exposure points for which explicit values are given. The exposure for the last MAPLHGR listed for a lattice is the maximum allowed nodal exposure for that lattice.

Page 7 of 21

NINE MILE POINT UNIT 2 Table lg COLR2-9, Revision 0 Cycle 9 MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE Bundle Type: GEl 1-P9CUB407-14GZ-120T-146-T-2503 (GEl 1)

Average Planar Exposure, MAPLHGR Limits (kw/ft)

GWd/ST Lattice Lattice Lattice Lattice Lattice 5230 5235 5239 5240 5238 0.00 12.76 10.98 11.04 10.93 13.38 0.20 12.69 11.03 11.08 10.99 13.35 1.00 12.52 11.10 11.17 11.08 13.26 2.00 12.46 11.19 11.28 11.21 13.23 3.00 12.46 11.29 11.40 11.35 13.24 4.00 12.49 11.38 11.51 11.48 13.27 5.00 12.52 11.48 11.63 11.62 13.29 6.00 12.55 11.58 11.74 11.74 13.32 7.00 12.58 11.68 1 i.84 11.86 13.34 8.00 12.60 11.79 11.93 11.98 13.36 9.00 12.62 11.89 12.03 12.09 13.37 10.00 12.63 12.00 12.13 12.22 13.37 12.50 12.48 11.96 12.10 12.25 13.33 15.00 12.09 11.83 11.97 12.16 12.94 17.50 11.70 11.71 11.79 11.95 12.54 20.00 11.30 11.49 11.51 11.65 12.14 25.00 10.59 11.01 11.00 11.10 11.36 30.00 10.10 10.68 10.68 10.54 10.87 35.00 9.62 10.36 10.35 10.07 10.40 40.00 9.15 9.89 9.93 9.64 9.93 45.00 8.68 9.46 9.49 9.24 9.46 50.00 8.21 9.07 9.07 8.87 8.99 54.80 7.77 55.00 8.66 8.67 8.53 8.52 57.53 8.48 57.61 8.48 8.48 57.95 8.36 58.26 8.22 NOTE: A indicates that there is no entry for this box and the limit can be determined by linearly interpolating between the previous and next point in each column. MAPLHGRs are interpolated between exposure points for which explicit values are given. The exposure for the last MAPLHGR listed for a lattice is the maximum allowed nodal exposure for that lattice.

Page 8 of 21

NINE MILE POINT UNIT 2 COLR2-9, Revision 0 Table lh Cycle 9 MOST LIMITING MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE Average MAPLHGR Limits (kw/ft)

Planar P9CUB4131 P9CUB414 P9CUB407-P9CUB407-P9CUB404-P9CUB407-P9CUB407

Exposure, (GEl1)

(GEl1) 2382 2383 2501 2502 2503 GWd/ST (GEl1)

(GEl1)

(GEl1)

(GEl1)

(GEll) 0.00 11.43 11.25 10.97 10.93 10.93 10.98 10.93 0.20 11.46 11.30 11.02 10.98 11.00 11.03 10.99 1.00 11.53 11.39 11.10 11.08 11.13 11.10 11.08 2.00 11.61 11.50 11.19 11.19 11.32 11.19 11.19 3.00 11.69 11.62 11.29 11.29 11.53 11.29 11.29 4.00 11.77 11.74 11.38 11.38 11.66 11.38 11.38 5.00 11.86 11.86 11.48 11.48 11.73 11.48 11.48 6.00 11.94 11.94 11.58 11.58 11.80 11.58 11.58 7.00 12.03 12.03 11.69 11.69 11.88 11.68 11.68 8.00 12.11 12.11 11.79 11.79 11.96 11.79 11.79 9.00 12.20 12.20 11.90 11.90 12.04 11.89 11.89 10.00 12.29 12.29 12.00 12.00 12.12 -

12.00 12.00 12.50 12.26 12.26 11.96 11.96 12.05 11.96 11.96 15.00 12.11 12.11 11.84 11.84 11.89 11.83 11.83 17.50 11.90 1"1.90 11.71 11.71 11.73 11.71 11.71 20.00 11.61 11.61 11.49 11.49 11.47 11.49 11.49 25.00 11.08 11.02 11.01 11.01 10.97 11.00 11.00 30.00 10.44 10.43 10.54 10.54 10.64 10.54 10.54 35.00 9.96 9.95 10.07 10.07 10.17 10.07 10.07 40.00 9.52 9.52 9.63 9.63 9.70 9.63 9.64 45.00 9.14 9.13 9.24 9.24 9.27 9.24 9.24 50.00 8.80 8.72 8.87 8.87 8.88 8.87 8.87 55.00 8.48 8.27 8.53 8.52 8.52 8.53 8.53 57.19 8.08 57.53 8.38 8.38 8.38 57.55 8.38 8.38 58.06 8.33 NOTE: A indicates that there is no entry for this box and the limit can be determined by linearly interpolating between the previous and next point in each column. MAPLHGRs are interpolated between exposure points for which explicit values are given. Theexposure for the last MAPLHGR listed for a lattice is the maximum allowed nodal exposure for that lattice.

Page 9 of 21

NINE MILE POINT UNIT 2 COLR2-9, Revision 0 Cycle 9 2.0 MINIMUM CRITICAL POWER RATIO (ODYN OPTION B) 2.1 Limits for Technical Specification 3.2.2 The Minimum Critical Power Ratio (MCPR) shall be equal to or greater than the appropriate MCPR limit from Figure 2a times the K(f) shown in Figure 2b with tau (or "c") defined as follows:

"E =

(Uave

- TB)

(TA - TCB) where:

TA = 0.866 seconds, control rod average scram insertion time limit to notch 39 per Specification 3.1.4.

n TB =.672 + 1.65 * [ N1,

Ni ]112 *.016 i=1 n

n Tave (ZN 1 T 1 ) / (ZN 1 )

i=l i-I n = number of surveillance tests performed in cycle N1 = number of active control rods measured in the i' surveillance test "c= average scram time to notch 39 of all rods measured in the ii surveillance test N1 = total number of active rods measured in Specification SR 3.1.4.1.

NOTE:

The MCPR Operating Limits in Figure 2a are based on a 1.06 Safety Limit MCPR (SLMCPR) for two recirculation loop operation and a 1.07 Safety Limit MCPR for single loop operation.

"c = 1.0 prior to performance of the initial scram time measurements for the cycle.

The Operating Limit MCPR values for Turbine Bypass Out of Service and EOC-RPT Out of Service are higher (more limiting) than for the standard normal operation case, and are therefore specifically identified in Figure 2a. The OLMCPR values for all other analyzed EOOS transient events are bounded by the Normal Operation limits.

For operation between 30% and 90% RTP with a backup pressure regulator out of service, additional MCPR limit requirements have been established. For operation

>70% but < 90% RTP maintain MCPR > normal operation MCPR limit from Figure 2a divided by fraction of rated thermal power. For operation > 30% and < 70% RPT the additional requirements are established in Figure 2c. There are no additional MCPR limits required for operation < 30% and > 90% RTP with a backup pressure regulator out of service.

Page 10 of 21

NINE MILE POINT UNIT 2 Figure 2a COLR2-9, Revision 0 Cycle 9 1.41 1.39 cc 1.37

1.

C-)

6' It 0

eL 1.35 E

E 1.33 1.31 1.29 0.4 0.6 0.8 1

Tau Page 11 of 21 Nine Mile Point 2 Cycle 9 BOC to EOC MCPR Operating Limits (1,1.40)

EOC-RPT Inoperable_

(1,1.36)

Torm ie OBpassInonerabe (1,1.32)

(0,1.32)

Normal Opeato 0

0.2

NL MILE POINT UNIT 2 I xre 2b Kf vs Core Flow 50 60 Core Flow, % of rated Page 12 of 21 COLR2-9, vision 0 Cycle 9 1.4 1.2 1

0.8 0.6 0.4 0.2 0

(20,1.2840)

(*,.73,1.0216)

(100,1.0 (10o5,1.0)

.1

.4

4.

4 9

.4 t

T 20 30 40 70 80 90 100 110

NINE MILE POINT UNIT 2 COLR2-9, Revision 0 "Cycle 9 Figure 2c MCPR Limits for Operation Between 30% and 70% RTP Without a Backup Pressure Regulator F

F F

F Operating MCPR shall be > MCPR limit line 2.2 2.1 2

1.9 R STRICTE REGION Enter T Bch.

pec. 3.2.2 40 45 50 55 60 Core Thermal Power (P) in units of % Rated Thermal Power (%RTP)

Page 13 of 21 ACC=PTA 3LE REGIO N Operating Limit MQPR (P) =

For 30% < P <70%

OLMCPR(P) = [1.55+0.0075(70%-P)]

D.

(.)

1.8 1.7 1.6 1.5 1.4 30 35 65 70 I

f f

NLNE MILE POINT UNIT 2 COLR2-9, Revision 0 Cycle 9 3.0 LINEAR HEAT GENERATION RATE (LHGR) 3.1 Limits for Technical Specification 3.2.3 The LHGR shall not exceed the limits in the table below.

Fuel Type P9CUB413 (GEl 1)

P9CU7B414 (GEl 1)

P9CUB407-2382 (GEl 1)

P9CUB407-2383 (GEl 1)

P9CUB407-2503 (GEl 1)

P9CUB407-2502 (GEl 1)

P9CUB404-2501 (GEl 1)

LHGR Limits 14.4 KW/FT 14.4 KW/FT 14.4 KW/FT 14.4 KW/FT 14.4 KW/FT 14.4 KW/FT 14.4 KW/FT For operation > 30% and < 90% RTP with a backup pressure regulator out of service, additional LHGR limit requirements have been established as shown in Figure 3. There are no additional LHGR limits required for operation < 30% and

> 90% RTP for operation with a backup pressure regulator out of service.

Page 14 of 21 NOTE:

NINE MILE POINT UNIT 2 COLR2-9, Revision 0 Cycle 9 Figure 3 LHGR Limit for Operation Between 30% and 90% RTP Without a Backup Pressure Regulator a

0.,

0.95 Es"RITE. RGIN 0.9 0.85 0.8-____

0.75____

0.7 ACC PT *BE REGI N SOperating MFLPD shall be < MFLPD limit MFLPD Limit =

For 30% _< P <70%

0.65 MFLPD = [0.86-0.00375(70%-P)]

For 70% _ P< 90 %:

MFLPD = FRTP o06 1

30 35 40 45 50 55 60 65 70 75 80 85 90 Core Thermal Power (P) in units of % Rated Thermal Power (%RTP)

Page 15 of 21

NINE MILE POINT UNIT 2 COLR2-9, Revision 0 Cycle 9 4.0 AVERAGE POWER RANGE MONITOR SETPOINTS 4.1 Limits for Technical Specification Table 3.3.1.1-1 (OPRM Upscale)

ALLOWABLE VALUE < 1.15 Page 16 of 21

NINE MILE POINT UNIT 2 COLR2-9, Revision 0 Cycle 9 5.0 ROD BLOCK MONITOR (RBM) 5.1 Allowable Value for Technical Specification Table 3.3.2.1-1 Function Allowable Value RBM Upscale NOTE:

  • 0.66 (W - AW) + 47%

with a maximum of 113%

W = Loop Recirculation Flow as a percentage of the loop recirculation flow which produces a rated core flow of 108.5 MLB/[JR. AW is defined as the difference in indicated drive flow (in percent of drive flow which produces rated core flow) between two loop and single loop operation at the same core flow. AW = 0 for two loop operation. AW = 5% for single loop operation.

Page 17 of 21

NINE MILE POINT UNIT 2 COLR2-9, Revision 0 Cycle 9

6.0 REFERENCES

FOR TECHNICAL SPECIFICATION Technical Specification 5.6.5.b.1:

General Electric Standard Application for Reactor Fuel, NEDE 24011-P-A-14 and NEDE 24011-P-A-14-US (June 2000).

Page 18 of 21

NINE MILE POINT UNIT 2 COLR2-9, Revision 0 Cycle 9

7.0 REFERENCES

FOR TECHNICAL SPECIFICATION BASES

2. 1.1 BASES REFERENCE 3.

General Electric Standard Application for Reactor Fuel, NEDE 24011 -P-A-14 and NEDE 2401 1-P-A-14-US (June 2000).

2.1.1 BASES REFERENCE 4:

Supplemental Reload Licensing Report for Nine Mile Point Nuclear Station Unit 2, Reload 8, Cycle 9, J 11-03938SRLR, Rev. 0, January 2002.

3.1.1 BASES REFERENCE 7:

General Electric Standard Application for Reactor Fuel, NEDE 2401 t-P-A-14 and

-NEDE 2401 1-P-A-14-US (June 2000).

3.1.6 BASES REFERENCE 1:

Supplemental Reload Licensing Report for Nine Mile Point Nuclear Station Unit 2, Reload 8, Cycle 9, J 11-03938SRLR, Rev. 0, January 2002.

3.2.1 BASES REFERENCE 1:

General Electric Standard Application for Reactor Fuel, NEDE 24011-P-A-14 and NEDE 24011-P-A-14-US (June 2000).

3.2.2 BASES REFERENCE 2:

General Electric Standard Application for Reactor Fuel, NEDE 24011-P-A-14 and NEDE 24011-P-A-14-US (June 2000).

3.2.2 BASES REFERENCE 3:

Supplemental Reload Licensing Report for Nine Mile Point Nuclear Station Unit 2, Reload 8, Cycle 9, J 11-03938SRLR, Rev. 0, January 2002.

3.2.3 BASES REFERENCE 1:

General Electric Standard Application for Reactor Fuel, NEDE 2401 1-P-A-14 and NEDE 24011-P-A-14US (June 2000).

3.2.3 BASES REFERENCE 2:

Supplemental Reload Licensing Report for Nine Mile Point Nuclear Station Unit 2, Reload 8, Cycle 9, JI 1-03938SRLR, Rev. 0, January 2002.

3.2.4 BASES REFERENCE 3:

General Electric Standard Application for Reactor Fuel, NEDE 24011-P-A-14 and NEDE 24011 -P-A-14-US (June 2000).

Page 19 of 21

NINE MILE POINT UNIT 2 8.0 SOURCE DOCUMENTS COLR2-9, Revision 0 Cycle 9 The Core Operating Limits contained in this report were obtained from the following documents:

CORE OPERATING LIMIT REFERENCE Section 1.0 - APLHGR LIMITS Tables Ia through I g Table 1 h and corresponding single loop multiplier Section 2.0 - MCPR LIMITS Figures 2a and 2b Tau equation and Pressure Regulator Out of Service Section 3.0 - LHGR LIMITS LHGR Pressure Regulator Out of Service Lattice Dependent MAPLHGR Report for NMP2 Reload 8, Cycle 9, JI 1-03938MAP, Rev 0, January 2002 Supplemental Reload Licensing Report for Nine Mile Point Nuclear Station Unit 2, Reload 8, Cycle 9, JI 1-03938SRLR, Rev 0, January 2002 Supplemental Reload Licensing Report for Nine Mile Point Nuclear Station Unit 2 Reload 8, Cycle 9, JI 1-03938SRLR, Rev 0, January 2002 GNF Engineering Report for Nine Mile Point Nuclear Station Unit 2 Reload 8, Cycle 9, J I1 03938-ER, March 2002 Supplemental Reload Licensing Report for Nine Mile Point Nuclear Station Unit 2 Reload 8 Cycle 9, J 11-03938SRLR, Rev 0, January 2002 GNF Engineering Report for Nine Point Nuclear Station Unit 2 Reload 8, Cycle 9, JI 1 03938-ER, March 2002 Page 20 of 21

NINE MILE POINT UNIT 2 8.0 SOURCE DOCUMENTS CORE OPERATING LIMIT Section 4.0 - APRM SETPOINTS Limits for Technical Specification Table 3.3.1.1-1 (OPRM Upscale)

Section 5.0 - RBM SETPOINTS COLR2-9, Revision 0 Cycle 9 (Cont)

REFERENCE Supplemental Reload Licensing Report for Nine Mile Point Station Unit 2, Reload 8, Cycle 9, J 11-03938 SRLR Rev 0, January 2002 GE Engineering Report for Nine Mile Point Nuclear Station Unit 2 Reload 2 Cycle 3, NFD92-016 January 1992 Page 21 of 21