Wyle Letter Reference No. EWS-GT21-020 May 22, 2002 Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555

Subject:

Part 21 on Irradiation performed with the Cobalt-60 Sources in the Georgia Tech Hot Cell

Dear Sirs:

Pursuant to 10 CFR Part 21, this letter notifies the NRC of the existence of a reportable defect and its evaluation.

The defect is an error in irradiation dose units as identified in the attached letter from Georgia Tech dated March 15, 2002, which was received by Wyle on April 11, 2002 and submitted to the NRC with our referenced 4/12 letter. The error applies to all equipment irradiated with the cobalt-60 sources in the Georgia Tech hot cell from 7/24/1997 to 7/6/2001. Georgia Tech reported radiation doses in units of rads-air (absorbed dose in air), but the actual radiation dose units were Roentgens. Since one Roentgen is equal to 0.877 rad, the actual dose is less than the reported value.

Wyle performed an evaluation that determined the following:

1. Wyle projects that include irradiation with the cobalt-60 sources in the Georgia Tech hot cell from 7/24/1997 to 7/6/2001.
2. The actual dose absorbed by equipment in Item 1.
3. Whether the actual dose in said projects identified in Item 1 envelops the customer specified requirements.

We have identified eighteen (18) companies and twenty-eight (28) specific reports that have been affected by this incident. The results of the evaluation are listed in the attached tables, with a separate table for each company.

Concurrent with this notification, Wyle is notifying the affected customers and informing them of the impact on qualification.

We will revise the affected report(s) according to our standard operating practices, and provide the revised report(s) to each customer.

Wyle Laboratories, Inc. 7800 Highway 20 West P.O. Box 077777 Huntsville, AL 35807-7777 Tel: (256)837-4411FP

Wyle Letter No. EWS-GT21-020 To: Document Control Desk/NRC 5/23/2002 Page 2 If you have any questions, please feel free to contact me by phone (256) 837-4411, Ext.

271, fax (256) 830-2109, or email esmithDhnt.wyielabs.com.

Sincerely, Wyle Laboratories, Inc.

Edward W. Smith Director, Contracts & Purchasing

Attachment:

Wyle Evaluation Summaries

Georgia Tech Part 21 5/6/2002 10:26 AM I

Customer Actual Total Dose /

Actual Total Actual Total Wyle Required Required Dose, Customer Required GT Reference Irradiation Period Specimen ID Dose, R Dose, rad Test Dose, rad rad Dose, %

Wyle Report No.

Customer Comments 9905 6/11/99-6/14/99 1 MSIV actuator 7.209E+06 6.322E+06 7.000E+06 7.000E+06 90.32% 40321 R99 Atwood & Morrill normal radiation aging 00-03 2/12/00-2/12/00 1 MSIV actuator S/N SAA123 7.189E+05 6.305E+05 7.000-E+05 7.000E+05 90.07% 43813R2000 Atwood & Morrill normal radiation aging (4y) 00-08 4/7/00-4/10/00 1 MSIV actuator 1.066E+07 9.349E+06 1.000E+07 1.000E+07 93.49% 43813R2000 Atwood & Morrill accident radiation (6h dose), see 00-11 for continuation 00-10 4/19/00-4/19/00 2 air valves 7.360E+05 6.455E+05 7.OOOE+05 7.000E+05 92.21% 43813R2000 Atwood & Morrill normal radiation aging (4 y) 00-11 5/18/00-5/25/00 1 MSIV actuator 9.441E+07 8.280E+07 9.120E+07 9.100E+07 90.99% 43813R2000 Atwood & Morrill accident radiation (balance of 6 month dose), see 00-08 for 1 st 6h dose 00-13 5/25/00-5/26/00 1 air valve pack 1.063E+07 9.323E+06 1.0001E+07 1.OOOE+07 93.23% 43813R2000 Atwood & Morrill accident radiation (6h dose) 1 of 1

Georgia Tech Part 21 GT Referencel Irradiation Period Specimen ID Actual Total Dose, R Actual Total Dose, rad Wyle Required Test Dose, rad Uustomer Actusi lotal Dose /

Actual D otal Dose /q I

Customer Required

Dose, Wvle Reroort No.97-18a 12/16/97-1217197 4, 9, 14,19, 24 1.021E+07 8.954E+06 1.OOOE+07 1.560E+031 573985.26% 46506R98 Bechtel Hanford Inc.

research test 97-18b 12/30/97-12/30/97 1, 2, 6, 7, 11, 12, 16, 17, 21, 22, 26, 27, 1.635E+03 1.434E+03 1.560E+03 1.560E+031 91.92% 46506R98 Bechtel Hanford Inc.

normal radiation aging 31, 32,36,37,41,42,46,4 17,51-60BeheHafrIn.omlrditnagg 5/6/2002 10:26 AM Uustomer Required Dose, rad Customer 1 of 1

Georgia Tech Part 21 Customer Actual Total Dose /

Actual Total Actual Total Wyle Required Required Dose, Customer Required GT Reference Irradiation Period Specimen ID Dose, R Dose, rad Test Dose, rad rad Dose, %

Wyle Report No.

Customer Comments 9805a 2/3198-3/9/98 215, 216, Baskets 14, 15,16,17, 23, 2.581 E+07 2.264E+07 2.500E+07 2.500E+07 90.54% 45120-2 Brookhaven National Laboratory normal radiation aging 24, 25, 28, 29 1

9805b 2/3/98-3/9/98 203, 204,205,206,19,20,21,26,27 3.253E+06 2.853E+06 3.140E+061 3.140E+06 90.86% 45120-2 Brookhaven National Laboratory normal radiation aging 9805c 2/10/98-2/12/98 212, 213, 214, 217, 218 2.552E+07 2.238E+07 2.500E+07 2.500E+07 89.52% 45120-2 Brookhaven National Laboratory normal radiation aging 9805d 2/16/98-2/21/98 203, 204,207-212 7.859E+07 6.892E+07 7.500E+07 7.500E+07 91.90% 45120-2 Brookhaven National Laboratory accident radiation 9805e 2/3/98-3/9/98 1, 4, 7, 9, 10, 12, 15, 20, 21, 24, 25, 7.666E÷07 6.714E+07 7.500E+07 7.500E+07 89.52% 45120-2 Brookhaven National Laboratory accident radiation 9805d,f 2/27/98-3/4/98 201,202,205, 206, 213, 214, 217, 218 1.554E+08 1.363E+08 1.500E+08 1.500E+08 90.86% 45120-2 Brookhaven National Laboratory accident radiation 9805e,g 2123/98-3/9/98 215, 215x, 216, 216x, 2, 3, 5, 6, 8, 11, 1.540E+08 1.351E+08 1.500E+08 1.500E+08 90.04% 45120-2 Brookhaven National Laboratory accident radiation 16,17, 26, 27, 28, 29 9819a 18/11/98-8/11/98 0303 2.268E+06 1.989E+06 2.200E+061 2.200E+06 90.41% 45120-3 Brookhaven National Laboratory normal radiation aging 9819a 18/11/98-8/11/98 0304 2.268E+06 1.989E+061 2.200E+061 2.200E+06 90.41% 45120-3 Brookhaven National Laboratory normal radiation aging 9819a 8/11/98-8/11/98 0305 2.268E+06 1.989E+061 2.200E+06 -

2.200E+06 90.41% 45120-3 Brookhaven National Laboratory normal radiation aging.

9819a 8/11/98-8/11/98 0306 2.268E+06 1.989E+06 2.200E+061 2.200E+06 90.41% 45120-3 Brookhaven National Laboratory normal radiation aging 9819b 8/12/98-8/17/98 0312 5.149E+07 4.516E+07 5.OOOE+07 5.OOOE+07 90.31% 45120-3 Brookhaven National Laboratory normal radiation aging 9819b 8/12/98-8/17/98 0313 5.149E+07 4.516E+07 5.OOOE+071 5.OOOE+07 90.31% 45120-3 Brookhaven National Laboratory normal radiation aging 9819b 8/12/98-8/17/98 0314 5.149E+07 4.516E+07 5.OOOE+071 5.000E+07 90.31% 45120-3 Brookhaven National Laboratory normal radiation aging 9819b 8/12/98-8/17/98 0315 5.149E+07 4.516E+07 5.000E+071 5.OOOE+07 90.31% 45120-3

'Brookhaven National Laboratory normal radiation aging 9819b 8/12/98-8/17/98 0316 5.149E+07 4.516E+07 5.000E+071 5.OOOE+07 90.31%[45120-3 Brookhaven National Laboratory normal radiation aging 9819b 8/12/98-8/17/98 0317 5.149E+07 4.516E+07 5.OOOE+071 5.OOOE+07 90.31% 45120-3 Brookhaven National Laboratory normal radiation aging 9819a 8/11198-8/11/98 8 (10303D/J0303D) 2.268E+06 1.989E+06 2.200E+061 2.200E+06 90.41% 45120-3 Brookhaven National Laboratory normal radiation aging 9819a 8/11/98-8/11/98 9 (10303F/J0303F) 2.268E+06 1.989E+06 2.200E+061 2.200E+06 90.41% 45120-3 Brookhaven National Laboratory normal radiation aging.

9819a 8/11/98-8/11/98 10 (10303G/J0303G) 2.268E+06 1.989E+061 2.200E+061 2.200E+06 90.41% 45120-3 Brookhaven National Laboratory normal radiation aging 9819a 8/11/98-8/11/98 11 (10303H/J0303H) 2.268E+06 1.989E+061 2.200E+06 2.200E+06 90.41% 45120-3 Brookhaven National Laboratory normal radiation aging 9819a 8/11/98-8/11/98 15 (10311F/J0311F) 2.268E+06 1.989E+061 2.200E+06 2.200E+061 90.41% 45120-3 Brookhaven National Laboratory normal radiation aging 9819b 8/12/98-8/17/98 19 (10312E/J0312E) 5.149E+07 4.516E+07 5.000E+07 5.000E+07 90.31% 45120-3 Brookhaven National Laboratory normal radiation aging 9819b 8/12/98-8/17/98 20 (10312F/J0312F) 5.149E+07 4.516E+07 5.0002+07 5.000E+07 90.31% 45120-3 Brookhaven National Laboratory normal radiation aging 9819b 8/12/98-8/17/98 21 (10312G/J0312G) 5.149E+07 4.516E+07 5.000E+07 5.000E+07 90.31% 45120-3 Brookhaven National Laboratory normal radiation aging 9819b 8/12/98-8/17/98 22 (10312H/J0312H) 5.149E+07 4.516E+07 5.000E+07 5.000E+07 90.31% 45120-3 Brookhaven National Laboratory normal radiation aging 9819c,e 8/26/98-9/9/98 0301 1.532E+08 1:344E+08 1.500E+08 1.500E+08 89.57% 45120-3 Brookhaven National Laboratory accident radiation 9819c,e 8/26/98-9/9/98 0302 1.532E+08 1.344E+08 1.500E+08 1.500E+08 89.57% 45120-3 Brookhaven National Laboratory accident radiation 9819c,e 18/26/98-9/9/98 0303 1.532E+08 1.344E+08 1.500E+08 1.500E+08 89.57% 45120-3 Brookhaven National Laboratory accident radiation 9819c,e 18/26/98-9/9/98 0304.

1.532E+08 1.344E+08 1.5002+08 1.5002+08 89.57% 45120-3 Brookhaven National Laboratory accident radiation 9819c,e 8126198-919198 0305 1.5322+08 1.344E+08 1.500E+08 1.500E+08 89.57% 45120-3 Brookhaven National Laboratory accident radiation 9819c,e 18/26/98-9/9/98 0306 1.532E+081 1.344E+08 1.500E+08 1.500E+08 89.57% 45120-3 Brookhaven National Laboratory

[accident radiation 9819c,e 18/26/98-9/9/98 0307 1.532E+08 1.344E+081 1.500E+08 1.500E+08 89.57% 45120-3 Brookhaven National Laboratory accident radiation 9819c,e 18/26/98-9/9/98 0308 1.532E+081 1344E+081 1.500E+08 1.500E+08 89.57% 45120-3 Brookhaven National Laboratory accident radiation 9819c,e

[8/26/98-9/9/98

-0309 1.532E+081 1.344E+08 1.500E 1.5I 1.500E+08 89.57% 45120-3 Brookhaven National Laboratory accident radiation 9819c,e 8/26/98-9/9/98 0310 1.532E+08 1.344E+08 1.500E+08 1.500E+08 89.57% 45120-3 lBrookhaven National Laboratory

[accident radiation 9819c,e 8/26/98-9/9/98 0311 1.5322+081 1.344E+08 1.500E+08 1.500E+081 89.57% 45120-3 IBrookhaven National Laboratory accident radiation 9819c,e 18/26/98-9/9/98 0312 1.532E+08 1.344E+08 1.500E+081 1.500E+081 89.57% 45120-3 1Brookhaven National Laboratory accident radiation 9819c,e 8/26/98-9/9/98

_0313 1

1.532E+08 1.344E+081 1.500E+081 1.500E+08 89.57% 45120-3 lBrookhaven National Laboratory accident radiation 9819c,e 8/26/98-9/9/98 0314 1.532E+08 1.344E+081 1.500E+081 1.500E+081 89.57%145120-3 lBrookhaven National Laboratory laccident radiation 9819d,f 8/31/98-9/14/98 0315 1.532E+08 1.344E+081 1.500E+081 1.500E+081 89.57% 145120-3

[Brookhaven National Laboratory accident radiation 9819d,f 18/31/98-9/14/98 0316 1.532E+08 1.344E+081 1.500E+081 1.500E+081 89.57%145120-3

{Brookhaven National Laboratory accident radiation 981 9c,e 18/26/98-9/9/98 0317 1.532E+08 1.344E+081 1.500E+081 1.500E+081 89.57%145120-3 Brookhaven National Laboratory accident radiation 5/6/2002 8:46 AM 1 of 7

Georgia Tech Part 21 Customer Actual Total Dose /

Actual Total Actual Total Wyle Required Required Dose, Customer Required GT Reference Irradiation Period Specimen ID Dose, R Dose, rad Test Dose, rad rad Dose, %

Wyle Report No.

Customer Comments 9819f 9/10/98-9/14/98 1 (10301F/J0301F) 7.665E+071 6.722E+07 7.500E+07 7.500E+07 89.63% 45120-3 Brookhaven National Laboratory jaccident radiation 9819f,g 19/l0/98-9/22/98 2 (10301G/J0301G) 1.534E+08 1.345E+08 1.500E+08 1.500E+08 89.69% 45120-3 Brookhaven National Laboratory accident radiation 9819f,g 19/10/98-9/22/98 3 (10301 H/J0301 H) 1.534E+08 1.345E+08 1.500E+08 1.500E+08 89.69% 45120-3 Brookhaven National Laboratory accident radiation 9819f 9/10/98-9/14/98

.4 (10302F/J0302F) 7.665E+07 6.722E+07 7.500E+07 7.500E+07 89.63% 45120-3 Brookhaven National Laboratory accident radiation 9819f,g 9/10/98-9/22/98 5 (10302G/J0302G) 1.534E+08 1.345E+08 1.500E+08 1.500E+08 89.69% 45120-3 Brookhaven National Laboratory accident radiation 9819f,g 9/10/98-9/22/98 6 (10302H/J0302H) 1.534E+08 1.345E+08 1.500E+08 1.500E+08 89.69% 45120-3 Brookhaven National Laboratory accident radiation 9819f 9/10/98-9/14/98 9 (10303F/J0303F) 7.665E+07 6.722E+07 7.500E+07 7.500E+07 89.63% 45120-3 Brookhaven National Laboratory accident radiation 9819f,g 9/10/98-9/22/98 10 (10303G/J0303G) 1.534E+08 1.345E+08 1.500E+08 1.500E+08 89.69%' 45120-3 Brookhaven National Laboratory accident radiation 9819f,g 9/10/98-9/22/98 11 (10303H/J0303H) 1.534E+08 1.345E+08 1.500E+08 1.500E+08 89.69% 145120-3 Brookhaven National Laboratory accident radiation 9819f 9/10/98-9/14/98 12 (10307F/J0307F) 7.665E+07 6.722E+07 7.500E+07 7.500E+07 89.63% 45120-3 Brookhaven National Laboratory accident radiation 9819f,g 9/10/98-9/22/98 13 (10307G/J0307G) 1.534E+08 1.345E+08 1.500E+08 1.500E+08 89.69% 145120-3 Brookhaven National Laboratory accident radiation 9819f,g 9/10/98-9/22/98 14 (10307H/J0307H) 1.534E+081 1.345E+08 1.500E+08 1.500E+08 89.69%145120-3 Brookhaven National Laboratory accident radiation 9819f 9/10198-9/14/98 15 (10311F/J0311F) 7.665E+071 6.722E+07 7.500E+07 7.500E+07 89.63% 45120-3 Brookhaven National Laboratory accident radiation 9819f,g 9/10/98-9/22/98 16 (10311 G/J031 1 G) 1.534E+081 1.345E+08 1.500E+08 1.500E+08 89.69% 45120-3 Brookhaven National Laboratory accident radiation 9819f,g 9/10/98-9/22/98 17 (10311H/J0311H) 1.534E+08 1.345E+08 1.500E+08 1.500E+08 89.69% 45120-3 Brookhaven National Laboratory accident radiation 9819f 9/10/98-9/14/98 20 (10312F/J0312F) 7.665E+07 6.722E+07 7.500E+071 7.500E+071 89.63%145120-3 Brookhaven National Laboratory accident radiation 9819f,g 9/10/98-9/22/98 21 (10312G/J0312G) 1.534E+08 1.345E+08 1.500E+081 1.500E+08 89.69% 45120-3 Brookhaven National Laboratory accident radiation 9819f,g 9/10/98-9/22/98 22 (10312H/J0312H) 1.534E+08 1.345E+08 1.500E+081 1.500E+08 89.69% 45120-3 Brookhaven National Laboratory accident radiation 9912e 8/24/99-8/2799 0403 2.599E+071 2.279E+07 2.500E+071 2.500E+07 91.17% 45120-4 Brookhaven National Laboratory normal radiation aging 9912e 18/24/99-8/2799 0404 2.599E+07 2.279E+07 2.500E+071 2.500E+07 91.17% 45120-4 JBrookhaven National Laboratory normal radiation aging 9912e 18/24/99-8/2799 0405 2.599E+07 2.279E+07 2.500E+071 2.500E+071 91.17% 45120-4 IBrookhaven National Laboratory normal radiation aging 9912e 18/24/99-8/2799 0406 2.599E+07 2.279E+07 2.500E+07 2.500E+07i 91.17% 45120-4 Brookhaven National Laboratory normal radiation aging 9912a 7/29/99-8/5/99 0407 5.360E+07 4.701E+071 5.000E+071 5.OOOE+07I 94.01% 45120-4 Brookhaven National Laboratory normal radiation aging 9912a 7/29/99-8/5/99 0408 5.360E+071 4.701E+071 5.OOOE+07[

5.OOOE+071 94.01% 45120-4 Brookhaven National Laboratory normal radiation aging 9912a 7/29/99-8/5/99 0409 5.360E+07[

4.701E+071 5.000E+07 I 5.OOOE+071 94.01%145120-4 Brookhaven National Laboratory normal radiation aging 9912a 7/29/99-8/5/99 0410 5.360E+07 1 4.701E+071 5.OOOE+07f 5.000E+07 94.01% 45120-4 Brookhaven National Laboratory normal radiation aging 9912a 7/29799-8/5/99 0411 5.360E+07 4.701E+071 5.OOOE+07 5.OOOE+071 94.01%145120-4 Brookhaven National Laboratory normal radiation aging 9912b 8/17/99-8/20/99 0412 5.157E+07 4.523E+07_

5.OOOE+07 5.OOOE+07 90.45% 45120-4 Brookhaven National Laboratory normal radiation aging 9912b 8/17/99-8/20/99 0413 5.157E+07 4.523E+07 5.OOOE+07 5.OOOE+07 90.45%145120-4 Brookhaven National Laboratory normal radiation aging 9912b 8/17/99-8/20/99 0414 5.157E+07 4.523E+07 5.OOOE+07 I

5.OOOE+07 90.45% 45120-4 Brookhaven National Laboratory normal radiation aging 9912b 8/17/99-8/20/99 0415 5.157E+07 4.523E+07 5.OOOE+07T 5.OOOE+07 90.45% 45120-4 Brookhaven National Laboratory normal radiation aging 9912b 8/17/99-8/20199 0416 5.157E+071 4.523E+07 5.0Q0E+071 5.OOOE+071 90.45%145120-4 Brookhaven National Laboratory normal radiation aging 9912a 7/29/99-8/5/99 9912b 8/17/99-8/20/99 9912e 8/24/99-8/2799 9912e 8/24/99-8/2799 9912e 8/24/99-8/2799 9912e 8/24/99-8/2799 9912c 8/20/99-8/23/99 9912a 7/29/99-8/5/99 9912a 7/29/99-8/5/99 9912a 17/29/99-8/5/99 9912a 7/29/99-8/5/99 9912b 8/17/99-8/20/99 9912b 8/17/99-8/20/99 9912b 8/1 7/99-8/20/99 10417 5.360E+07 4.70 1 E+07 5.000E+07 5.000E+07 94.01%1 45120-4 Brookhaven National Laboratory normal radiation aaina 0418

}

5.157E+071 4.523E+07 5.OOOE+07J 5.OOOE+07t 90.45% 45120-4 Brookhaven National Laboratory Inormal radiation aging 8 (10403D/J0403D) 2.599E+07 2.279E+07 2.500E+071 2.500E+07 91.1 7% 45120-4 Brookhaven National Laboratory Inormal radiation aging 9 (10403F/J0403F)

T 2.599E+071 2.279E+07 2.500E+07 2.500E+07 91.17% 45120-4 Brookhaven National Laboratory normal radiation aging 10 (10403G/J0403G) 2.599E+071 2.279E+07 2.500E+07 2.500E+07[

91.17% 45120-4 Brookhaven National Laboratory normal radiation aging Ill (10403H/J0403H) 2.599E+071 2.279E+07 2.500E+071 2.500E+071 91.17% 45120-4 Brookhaven National Laboratory normal radiation aging 14 (10407D/J0407D) 2.569E+071 2.253E+07 2.500E+071 2.500E+071 90.12% 45120-4 Brookhaven National Laboratory normal radiation aging 15 (10407E/J0407E) j 5.360E+07 4.701E+07 5.OOOE+07 5.OOOE+071 94.01% 45120-4 Brookhaven National Laboratory normal radiation aging 16 (10407F/J0407F) 5.360E+071 4.701E+07!

5.OOOE+071 5.OOOE+071 94.01%145120-4 Brookhaven National Laboratory normal radiation aging 17 (10407G/J0407G)

I 5.360E+071 4.701E+071 5.000E+071 5.OOOE+071 94.01%145120-4 Brookhaven National Laboratory normal radiation aging 18 (10407H/J0407H) 5.360E+071 4.701E+071 5.OOOE+07 5.000E+071 94.01% 45120-4 Brookhaven National Laboratory normal radiation aging 120 (10412E/J0412E)

I 5.157E+07 4.523E+071 5.OOOE+07 5.OOOE+071 90.45% 45120-4 Brookhaven National Laboratory normal radiation aging 21 (10412F/J0412F) 5.157E+07 4.523E+071 5.OOOE+071 5.OOOE+071 90.45% 45120-4 IBrookhaven National Laboratory Inormal radiation aging 22 (10412G/J0412G) 5.157E+071 4.523E+07!

5.OOOE+071 5.000E+071 90.45%145120-4 1Brookhaven National Laboratory Inormal radiation aging 5/6/2002 8:46 AM 2 of 7

Georgia Tech Part 21 IJ Customer Actual Total Dose /

Actual Total Actual Total Wyle Required Required Dose, Customer Required GT Reference Irradiation Period Specimen ID Dose, R Dose, rad Test Dose, rad rad Dose, %

Wyle Report No.

Customer Cmments 9912b 8/17/99-8/20/99 23 (10412H/J0412H) 5.157E+07 4.523E+071 5.00E+07 5.000E+071 90.45%145120-4 Brookhaven National Laboratory normal radiation aging 9912i 9/10/99-9/21/99 0401 1.541E+08 1.351E+08 1.500E+081 1.500E+08 90.10%145120-4 Brookhaven National Laboratory accident radiation 9912i 19/10/99-9/21/99 0402 1.541E+08 1.351E+08 1.500E+081 1.500E+08 90.10% 45120-4 Brookhaven National Laboratory accident radiation 9912i 9/10/99-9/21/99 0403 1.541E+08 1.351E+08 1.500E+08 1.500E+08 90.10% 45120-4 Brookhaven National Laboratory accident radiation 9912i 9/10/99-9/21/99 0404 1.541E+08 1.351E+08 1.500E+08 1.500E+08 90.10% 45120-4

{Brookhaven National Laboratory accident radiation 9912i 9/10/99-9/21/99 0405 1.541E+08 1.351E+08 1.500E+08 1.500E+08 90.10% 45120-4 Brookhaven National Laboratory accident radiation 9912i 9/10/99-9/21/99 0406 1.541E+08 1.351E+08 1.500E+08 1.500r+08 90.10% 45120-4 Brookhaven National Laboratory accident radiation 9912i 9/10/99-9/21/99 0407 1.541 E+08 1.351E+081 1.500E+08 1.500E+08 90.10% 45120-4 Brookhaven National Laboratory accident radiation 9912i 9/10/99-9/21/99 0408 1.541E+08 1.351E+08[

1.500E+08 1.500E+08 90.10% 45120-4 Brookhaven National Laboratory accident radiation 9912i 9/10/99-9/21/99 0409 1.541E+08 1.351E+08 1.500E+08 1.500E+08 90.10% 45120-4 Brookhaven National Laboratory accident radiation 9912i 9/10/99-9/21/99 0410 1.541E+08 1.351E+081 1.500E+08 1.500E+08 90.10% 45120-4 Brookhaven National Laboratory accident radiation 9912i 9/10/99-9/21/99 0411 1.541E+08 1.351E+08 1.500E+08 1.500E+08 90.10% 45120-4 Brookhaven National Laboratory accident radiation 9912i 9/10/99-9/21/99 0412 1.541E+08 1.351E+081 1.500E+08 1.500E+08 90.10% 45120-4 Brookhaven National Laboratory accident radiation 9912i 9/10/99-9/21/99 0413 1.541 E+081 1.351E+081 1.500E+08 1.500E+08 90.10% 45120-4 Brookhaven National Laboratory accident radiation 9912i 9/10/99-9/21/99 0414 1.541E+081 1.351E+08 1.500E+08 1.500E+08 90.10% 45120-4 Brookhaven National Laboratory accident radiation 9912i 9/10/99-9/21/99 0415 1.541E+08 1.351E+08 1.5OOE+08 1.500E+08 90.10% 45120-4 Brookhaven National Laboratory accident radiation 9912i 9/10/99-9/21/99 0416 1.541E+08 1.351E+08 1.500E+081 1.500E+08 90.10% 45120-4 Brookhaven National Laboratory accident radiation 9912j 9/124/99-10/4/99 0417 1.548E+08 1.358E+08 1.500E+081 1.500E+08 90.51%145120-4 Brookhaven National Laboratory accident radiation 9912j 9/24/99-10/4/99 0418 1.548E+08 1.358E+08 1.500E+08 1.500E+081 90.51%45120-4 Brookhaven National Laboratory accident radiation 9912h 9/3/99-9/7/99 1 (10401F/J0401F) 7.708E+071 6.760E+07 7.500E+07 7.500E+07 90.13% 145120-4 Brookhaven National Laboratory accident radiation 9912j 9/24/99-1014/99 2 (10401 G/J 0401 G)

I 1.548E+081 1.358E+08, 1.500E+08 1.500E+08 90.51%145120-4

Brookhaven National Laboratory accident radiation 9912j
  • 9/24/99-10/4/99 3 (10401H/J0401H) 1.548E+081 1.358E+08 1.500E+08[

1.500E+08 90.51% 45120-4 Brookhaven National Laboratory

[accident radiation 9912h 9/3/99-9/7/99 4 (10402F/J0402F) 7.708E+071 6.760E+07 7.500E+07[

7.500E+07 90.13% 45120-4 Brookhaven National Laboratory laccident radiation 9912j

'9/24/99-10/4/99 5 (10402G/J0402G) 1.548E+081 1.358E+081 1.500E+08[

1.500E+08 90.51% 45120-4 Brookhaven National Laboratory accident radiation 9912j 9/24199-10/4/99 6 (10402H/J0402H) 1.548E+08 1.358E+08 1.500E+081 1.500E+08 90.51% 45120-4 Brookhaven National Laboratory accident radiation 9912h 9/3/99-9/7/99 9 (10403F/J0403F) 7.708E+07 6.760E+07 7.500E+07 7.500E+07 90.13% 45120-4 Brookhaven National Laboratory accident radiation 9912j 9/24/99-10/4/99 10 (10403G/J0403G) 1.548E+08 1.358E+081 1.500E+08 1.500E+081 90.51% 145120-4 Brookhaven National Laboratory accident radiation 9912j 9/24/99-10/4/99 11 (10403H/J0403H) 1.548E+08 1.358E+081 1.500E+08 1.500E+08 90.51% 45120-4 Brookhaven National Laboratory accident radiation 9912h 9/3/99-9/7/99 16 (10407F/J0407F) 7.708E+07 6.760E+07 7.500E+07 7.500E+07[

90.13% 45120-4 Brookhaven National Laboratory accident radiation 9912j 9/24/99-10/4/99 17 (10407G/J0407G) 1.548E+08 1.358E+08 1.500E+08 1.500E+08 90.51% 45120-4 Brookhaven National Laboratory accident radiation 9912j 9/24/99-10/4/99 18 (10407H/J0407H) 1.548E+081 1.358E+08 1.500E+081 1.500E+08 90.51% 45120-4 Brookhaven National Laboratory accident radiation 9912h 9/3/99-9/7/99 9912i 9/24/99-10/4/99 9912' 9/24/99-10/4/99 9912d 8/23/99-8/25/99 9912d 8/23/99-8/25/99 9912e 8/25/99-8/27/99 9912e 18/25/99-8/27/99 9912c 8/20/99-8/23/99 9912c 8/20/99-8/23/99 9912g 18/30/99-9/3/99 9912g 18/30/99-9/3/99 9912g 18/30/99-9/3/99 9912b 18/17/99-8/20/99 9912b 18/17/99-8/20/99 9912c,f 18/20/99-8/30/99 21 (10412F/J0412F) 7.708E+07 6.760E+07 7.500E+07 7.500E+07 90.13% 145120-4 IBrookhaven National Laboratory ac~cident rndiatinn 22 10412GJ0412G) 1.548E+08 1.358E+081 1.500E+081 1.500E+08

.90.5..4.5.12-0-.4 Brookhaven Naional Laborator Iaccident radiation

.23 (10412H/J0412H) 1.548E+081 1.358E+081 1.500E+081 1.500E+08 90.51% 45120-4 Brookhaven National Laboratory accident radiation 10504 2.579E+07 2.262E+071 2.500E+071 2.500E+071 90.47% 45120-5, Rev. A Brookhaven National Laboratory normal radiation aging 0505 2.579E+07 2.262E+07 2.500E+071 2.500E+071 90.47%45120-5, Rev. A Brookhaven National Laboratory normal radiation aging 0506 2.579E+07 2.262E+071 2.500E+071 2.500E+071 90.47%145120-5, Rev. A IBrookhaven National Laboratory normal radiation aging 0506 2.599E+071 2.279E+071 2.500E+07I 2.500E+071 91.17% 45120-5, Rev. A ýBrookhaven National Laboratory normal radiation aging 0507 2.599E+071 2.279E+071 2.500E+071 2.500E+071 91.17%145120-5, Rev. A Brookhaven National Laboratory normal radiation aging 0508 2.569E+07 2.253E+071 2.500E+071 2.500E+07!

90.12% 45120-5, Rev. A IBrookhaven National Laboratory normal radiation aging 0509 2.569E+071 2.253E+07!

2.500E+071 2.500E+071 90.1%145120-5, Rev. A Brookhaven National Laboratory normal radiation aging 0511 5.149E+07 4.516E+07 5.000E+071 5.000E+071 90.31% 45120-5, Rev. A Brookhaven National Laboratory normal radiation aging 512 5.149E+071 4.516E+071 5.000E+071 5.000E+071 90.31% 145120-5, Rev. A Brookhaven National Laboratory Inormal radiation aging 0.51 5.149E+07 4.5162E+071 5.000E+071 5.000E+071 90.31%145120-5, Rev. A Brookhaven National Laboratory normal radiation aging 10512 5.157E+07 4.523E+07 5.000E+071 5.OOOE+07i 90.45% 45120-5, Rev. A 1Brookhaven National Laboratory inormal radiation aging 0513 5.1572+07 4.5232+07 5.000E+071 5.000E+071 90.45% 45120-5, Rev. A Brookhaven National Laboratory normal radiation aging 0515 5.135E+07 4.503E+07 5.OOOE+071 5.000E+071 90.07%145120-5, Rev. A Brookhaven National Laboratory normal radiation aging 5/6/2002 8:46 AM 3 of 7

Georgia Tech Part 21 R eCustomer Actual Total Dose /

Actual Total Actual Total Wyle Required Required Dose, Customer Required GT Irradiation Period Specimen ID Dose, R Dose, rad Test Dose, rad rad Dose, %

j Wyle Report No.

Customer Comments 9912c,f 8/20/99-8/30/99 0516 5.135E+071 4.503E+07 5.000E+07[

5.OOOE+07 90.07% 45120-5, Rev. A IBrookhaven National Laboratory normal radiation aging 9912g 8/30/99-9/3/99 0517 5.149E+07 4.516E+07 5.000E+07 5.000E+07 90.31% 45120-5, Rev. A Brookhaven National Laboratory normal radiation aging 9912b 8/17/99-8/20/99 0518 5.157E+07 4.523E+07 5.OOOE+07 5.OOOE+07 90.45% 45120-5, Rev. A Brookhaven National Laboratory normal radiation aging 9912a 7/29/99-8/5/99 0519 5.360E+07 4.701E+07 5.000E+07 5.000E+07 94.01% 45120-5, Rev. A Brookhaven National Laboratory Lnormal radiation aging 9912d 8/23/99-8/25/99 11 (10504D/J0504D) 2.579E+07 2.262E+07 2.500E+07 2.500E+071 90.47% 45120-5, Rev. A Brookhaven National Laboratory Inormal radiation aging 9912d 8/23/99-8/25/99 12 (10504F/J0504F) 2.579E+07 2.262E+07[

2.500E+07 2.500E+07 90.47% 45120-5, Rev. A Brookhaven National Laboratory Tnormal radiation aging 9912d 8/23/99-8/25/99 13 (10504G/JO504G)

T 2.579E+07 2.262E+071

-2.500E+07 2.500E+071 90.47% 145120-5, Rev. A Brookhaven National Laboratory normal radiation aging 9912d 8/23/99-8/25/99 14 (10504H/J0504H) 2.579E+07 2.262E+071 2.500E+071 2.500E+071 90.47%A45120-5, Rev. A Brookhaven National Laboratory normal radiation aging 9912e 18/25/99-8/27/99 16 (10506D/JO506D) 2.599E+07 2.279E+07 2.500E+071 2.500E+071 91.17% 45120-5, Rev. A Brookhaven National Laboratory I normal radiation aging 9912e 18/25/99-8/27/99 17 (10506F/JO506F) 2.599E+07 2.279E+07 2.500E+07 2.500E+07 91.17% 45120-5, Rev. A Brookhaven National Laboratory normal radiation aging 9912e 18/25/99-8/27/99 18 (10506G/J0506G) 2.599E+07 2.279E+07 2.500E+07 2.500E+07 91.17% 45120-5, Rev. A Brookhaven National Laboratory Inormal radiation aging 9912e 18/25/99-8/27/99 19 (10506H/J0506H) 2.599E+07 2.279E+07 2.500E+07 2.500E+071 91.17% 45120-5, Rev. A Brookhaven National Laboratory Inormal radiation aging 9912c 8/20/99-8/23/99 21 (10508D/JO508D) 2.569E+07 2.253E+07 2.500E+07 2.500E+071 90.12% 45120-5, Rev. A Brookhaven National Laboratory normal radiation aging 9912c 8/20/99-8/23/99 22 (10508F/J0508F) 2.569E+07 2.253E+07 2.500E+07 2.500E+071 90.12% 45120-5, Rev. A Brookhaven National Laboratory normal radiation aging 9912c 8120/99-8/23/99 23 (10508G/J0508G) 2.569E+07 2.253E+07 2.500E+07 2.500E+071 90.12% 45120-5, Rev. A Brookhaven National Laboratory normal radiation aging 9912c 8/20/99-8/23/99 24 (10508H/J0508H) 2.569E+07 2.253E+07 2.500E+07 2.500E+071 90.12% 45120-5, Rev. A Brookhaven National Laboratory normal radiation aging 9912g 18/30/99-9/3/99 26 (10510E/JO51OE) 5.149E+07 4.516E+07 5.000E+07 5.000E+071 90.31% 45120-5, Rev. A Brookhaven National Laboratory normal radiation aging 9912g 18/30/99-9/3/99 27 (1051 OF/JO51 OF) 5.149E+07 4.516E+07 5.OOOE+07 5.000E+07i 90.31% 45120-5, Rev. A Brookhaven National Laboratory normal radiation aging 9912g 8/30/99-9/3/99 28 (10510G/JO51OG) 5.149E+07 4.516E+07 5.000E+07 5.OOOE+07' 90.31% 45120-5, Rev. A Brookhaven National Laboratory normal radiation aging 9912g 8/30/99-9/3/99 29 (10510H/J051 OH) 5.149E+07 4.516E+07[

5.000E+07 5.000E+07 90.31% 45120-5, Rev. A Brookhaven National Laboratory normal radiation aging 9912b 8/17/99-8/20/99 31 (10513E/J0513E) 5.157E+07 4.523E+07 5.000E+07 5.000E+07 90.45% 45120-5, Rev. A Brookhaven National Laboratory normal radiation aging 9912b 18/17/9 9-8/ 20/ 9 9 32 (10513F/J0513F) 5.157E+07 4.523E+07 5.000E+07 5.OOOE+071 90.45%145120-5, Rev. A Brookhaven National Laboratory normal radiation aging 9912b 18/17/99-8/20/99 33 (10513G/JO513G) 5.157E+07 4.523E+071 5.000E+07 5.000E+07 90.45% 45120-5, Rev. A Brookhaven National Laboratory normal radiation aging 9912b 8/17/99-8/20199 34 (10513H/J0513H) 5.157E+07 4.523E+07 5.000E+07 5.000E+071 90.45%145120-5, Rev. A Brookhaven National Laboratory normal radiation aging 9912a 7/29/99-8/5/99 36 (10515E/J0515E) 5.360E+071 4.701E+07 5.000E+07 5.000E+071 94.01% 45120-5, Rev. A Brookhaven National Laboratory normal radiation aging 9912a 7/29/99-8/5/99 37 (1051 SF/JO515F) 5.360E+07 4.701E+07 5.000E+07 5.000E+071 94.01%145120-5, Rev. A Brookhaven National Laboratory normal radiation aging 9912a 7/29/99-8/5/99 38 (10515G/J0515G) 5.360E+07 4.701E+07 5.OOOE+07 5.000E+071 94.01% 45120-5, Rev. A Brookhaven National Laboratory normal radiation aging 9912a 7/29/99-8/5/99 39 (10515H/JO515H) 5.360E+07 4.701E+071 5.000E+07 5.000E+07 94.01%145120-5, Rev. A Brookhaven National Laboratory normal radiation aging 9912k 10/8/99-10/20/99 0501 1.540E+081 1.351E+08 1.500E+08 1.500E+081 90.04% 45120-5, Rev. A Brookhaven National Laboratory accident radiation 9912k 10/8/99-10/20/99 0502 1.540E+081 1.351 E+08 1.500E+08 1.500E+081 90.04% 45120-5, Rev. A Brookhaven National Laboratory accident radiation 9912k 10/8/99-10/20/99 0503 1.540E+081 1.351E+08 1.500E+08 1.500E+08 90.04% 45120-5, Rev. A Brookhaven National Laboratory accident radiation 9912k 10/8/99-10/20/99 0504 1.540E+081 1.351 E+08 1.500E+08 1.500E+08 90.04% 45120-5, Rev. A Brookhaven National Laboratory accident radiation 9912k 10/8/99-10/20/99 0505 1.540E+081 1.351E+08 1.500E+08 1.500E+08 90.04% 45120-5, Rev. A Brookhaven National Laboratory accident radiation 9912k 10/8/99-10/20/99 0506 1.540E+081 1.351E+08 1.500E+08 1.500E+08 90.04% 45120-5, Rev. A Brookhaven National Laboratory accident radiation 9912k 10/8/99-10/20/99 0507 1.540E+081 1.351E+08 1.500E+081 1.500E+08 90.04% 45120-5, Rev. A Brookhaven National Laboratory accident radiation 9912k 10/8/99-10/20/99 0508 1.540E+081 1.351E+081 1.500E+081 1.500E+081 90.04% 45120-5, Rev. A Brookhaven National Laboratory accident radiation 9912k 10/8/99-10/20/99 10509 1.540E+081 1.351E+081 1.500E+081 1.500E+081 90.04% 45120-5, Rev. A Brookhaven National Laboratory accident radiation 9912k 10/8/99-10/20/99 0510 1.540E+081 1.351E+08 1.500E+081 1.500E+08 90.04%145120-5, Rev. A Brookhaven National Laboratory accident radiation 10/8/99-110/2*/.q 110/8/99-10/20/99 10------

/ 8 9912k 10/8/99-10/20/99 9912k 10/8/99-10/20/99 10/8/99-10/20/99 1.540E+08 1.351E+081 1.500E+081 1.500E+081 90.04%I145120-5. Rev. A Brookhaven National Laboratory ac.oident radiationn 90.04%145120-5,Rev A Brookhaven National Laboratory accident radiation 1.540E+08 1.540E+081 1.351 E+081 1.500E+081 1.500E+08 1.351 E+08 1.500E+081 1.500E+081 1.540E+081

1. 3 51 E-----

1.540E+081 1.351E+081 1.500E+081 1.500E+08 1.540E+081 1.351E+08 1.500E+081 1.500E+081 90.51 % j 45120-5, jaccident radiation Brookhaven National Laboratory 1.548E+081 1.358E+081 1.500E+081 1.500E+08 1.548E+081 1.358E+081 1.500E+08 1.500E+081 90.04%145120-5. Rev. A 90.04% 145120-5. Rev. A 90.04% 145120-5. Rev. A 90.04 %o145120-5. Rev. A 90.04 %o145120-5. Rev. A 90.51%145120-5. Rev. A 90.51% 145120-5. Rev. A Brookhaven National Laboratory SBrookhaven National Laboratory I Brookhaven National Laboratory iBrookhaven National Laboratory SBrookhaven National Laboratoryr IBrookhaven National Laboratory IBrookhaven National Lahboratory

!lar.r-.idenf radiationn acctident radiatilnn acieednt radiatinn acrc.ident radiationn Iacec.ide.nt radiationn Iac~ident radiatinn laccr~ilent radiatinn 5/6/2002 8:46 AM 9912k 9912k 9912k 9912k 0511 1012 70 513 10514 10515 10516 1991 2i 9/24/99-10/4/99 J0517 19912j 19/24/99-10/4/9 0518 4 of 7 i

0511 0512 0513 0514 1515 P516 1

, Rev A I Brookhaven National Laboratwy jaccident radiation 90.04%145120-5,Rev A Brookhaven National Laboratory I accident radiation 90.04%'45120-5,Rev A Brookhaven National Laboratory jaccident radiation S....

.. ~ ~ ~

~9.......45.....

.,Re A...

I Brookhaven Na io a

,acdn radiation 9912j 19/24/99-10/4/99 0517 9912j 19/24/99-10/4/99 0518 90.04%145120-5,Rev A Brookhaven National Laboratory accident radiation 90.51%145120-5 Rev. A lBrookhaven National Laboratory accidpnt mrfinfinn

Georgia Tech Part 21 I

Specimen I

I Customer Actual Total Dose /

Actual Total Actual Total Wyle Required Required Dose, Customer Required GT Reference Irradiation Period ID Dose, R Dose, rad

[ Test Dose, rad rad Dose, %

Wyle Report No.

Customer Comments 9912j 9124/99-10/4/99 0519 j

1.548E+08 1.358E+081 1.500E+081 1.500E+081 90.51%145120-5, Rev. A Brookhaven National Laboratory accident radiation 9912h 9/3/99-9/7/99 1 (10501F/J0501 F) 7.708E+071 6.760E+071 7.500E+071 7.500E+071 90.13% 45120-5, Rev. A I Brookhaven National Laboratory accident radiation 9912j 9/24/99-10/4/99 2 (10501G/J0501G) 1.548E+08 1.358E+081 1.500E+081 1.500E+08 90.51% 45120-5, Rev. A I Brookhaven National Laboratory accident radiation 9912 19/24/99-1014/99 3 (10501H/J0501H) 1.548E+08 1.358E+08 1.500E+08 1.500E+08 90.51% 45120-5, Rev. A Brookhaven National Laboratory accident radiation 9912h 9/3/99-9/7/99 4 (10502F/J0502F) 7.708E+07 6.760E+07 7.500E+07 7.500E+071 90.13%145120-5, Rev. A Brookhaven National Laboratory accident radiation 9912i 9/24/99-10/4/99 5 (10502G/J0502G) 1.548E+08 1.358E+08 1.500E+08 1.500E+08 90.51% 45120-5, Rev. A Brookhaven National Laboratory accident radiation 9912j 9/24/99-10/4/99 6 10502H/J0502H) 1.548E+08 1.358E+081 1.500E+08 1.500E+08 90.51% 45120-5, Rev. A Brookhaven National Laboratory accident radiation 9912h 9/3/99-9/7/99 7 (10503F/J0503F) 7.708E+07 6.760E+071 7.500E+07 7.500E+07 90.13% 45120-5, Rev. A Brookhaven National Laboratory accident radiation 9912 9/24/99-10/4/99 8 (10503G/J0503G) 1.548E+08 1.358E+08 1.500E+081 1.500E+08 90.51% 45120-5, Rev. A

[Brookhaven National Laboratory accident radiation 9912j 9/24/99-10/4/99 9 (10503H/J0503H) 1.548E+08 1.358E+081 1.500E+081 1.500E+08 90.51% 45120-5, Rev. A IBrookhaven National Laboratory accident radiation 9912h 9/3/99-9/7/99 12 (10504F/J0504F) 7.708E+071 6.760E+071 7.500E+07 7.500E+07 90.13% 45120-5, Rev. A Brookhaven National Laboratory accident radiation 9912j 9/24/99-10/4/99 13 (10504G/JO504G) 1.548E+081 1.358E+081 1.500E+08 1.500E+08 90.51%145120-5, Rev. A Brookhaven National Laboratory accident radiation 9912j 9/24/99-10/4/99 14 (10504H/JO504H) 1.548E+08[

1.358E+08 1.500E+08 1.600E+081 90.51% 45120-5, Rev. A

?Brookhaven National Laboratory accident radiation 9912h 9/3/99-9/7/99 17 (10506F/J0506F) 7.708E+071 6.760E+07 7.500E+071 7.500E+07 90.13% 45120-5, Rev. A

[Brookhaven National Laboratory accident radiation 9912j 9/24/99-10/4/99 18 (10506G/J0506G) 1.548E+081 1.358E+08 1.500E+081 1.500E+081 90.51% 45120-5, Rev. A Brookhaven National Laboratory accident radiation 9912j 9/24/99-10/4/99 19 (10506H/J0506H) 1.548E+08J 1.358E+08 1.500E+08 1.500E+08 90.51% 45120-5, Rev. A Brookhaven National Laboratory accident radiation 9912h 9/3/99-9/7/99 22 (10508F/J0508F) 7.708E+071 6.760E+07 7.500E+07 7.500E+07 90.13%145120-5, Rev. A Brookhaven National Laboratory accident radiation 9912j 9/24/99-10/4/99 23 (10508G/J0508G) 1.548E+081 1.358E+08 1.500E+081 1.500E+08 90.51% 45120-5, Rev. A Brookhaven National Laboratory accident radiation 9912j 19/24/99-10/4/99 24 (10508H/J0508H) 1.548E+081 1.358E+08 1.500E+08 1.500E+08 90.51% 45120-5, Rev. A Brookhaven National Laboratory accident radiation 9912h 9/3/99-9/7/99 27 (1051OF/JO51OF) 7.708E+071 6.760E+07 7.500E+07 7.500E+07 90.13% 45120-5, Rev. A Brookhaven National Laboratory accident radiation 9912j 19/24/99-10/4/99 28 (1051 OG/JO51 OG) 1.548E+081 1.358E+081 1.500E+08 1.500E+08 90.51% 45120-5, Rev. A Brookhaven National Laboratory accident radiation 9912j 19/24/99-10/4/99 29 (10510H/JO51OH) 1.548E+081 1.358E+081 1.500E+081 1.500E+081 90.51% 45120-5, Rev. A Brookhaven National Laboratory accident radiation 9912h 9/3/99-9/7/99 32 (10513F/JO513F) 7.708E+071 6.760E+07 7.500E+071 7.500E+071 90.13% 45120-5, Rev. A Brookhaven National Laboratory accident radiation 9912j 9/24/99-10/4/99 33 (10513G/J0513G) 1.548E+081 1.358E+08 1.500E+081 1.500E+081 90.51% 45120-5, Rev. A Brookhaven National Laboratory accident radiation 9912j 9/24/99-10/4/99 34 (10513H/J0513H) 1.548E+081 1.358E+081 1.500E+081 1.500E+08 90.51% 45120-5, Rev. A Brookhaven National Laboratory laccident radiation 9912h 9/3/99-9/7/99 37 (10515F/J0515F) 7.708E+071 6.760E+07 7.500E+071 7.500E+07 90.13% j45120-5, Rev. A Brookhaven National Laboratory accident radiation 9912j 9/24/99-10/4/99 38 (10515G/JO515G) 1.548E+08[

1.358E+08 1.500E+081 1.500E+081 90.51% 45120-5, Rev. A Brookhaven National Laboratory laccident radiation 9912j 9/24/99-10/4/99 39 (10515H/JO515H) 1.548E+08 1.358E+08 1.500E+081 1.500E+081 90.51% 45120-5, Rev. A Brookhaven National Laboratory laccident radiation 9912m,n 01/18/00-1/24/00 605 7.728E+07 6.777E+07 7.500E+07 7.500E+07 90.37% 45120-6 Brookhaven National Laboratory normal radiation aging 9912m,n 01/18/00-1/24/00 606 7.728E+07 6.777E+07 7.500E+07 7.500E+07 90.37% 45120-6 lBrookhaven National Laboratory normal radiation aging 9912mn 01/18/00-1/24/00 607 7.728E+07 6.777E+07 7.500E+07 7.500E+071 90.37%145120-6 Brookhaven National Laboratory normal radiation aging 9912m,n 01/18/00-1/24/00 608 7.728E+07 6.777E+07 7.500E+07 7.500E+07 90.37% 45120-6 Brookhaven National Laboratory normal radiation aging 9912m,n 01/18/00-1/24/00 609 7.728E+07 6.777E+07 7.500E+07 7.500E+071 90.37% 45120-6 Brookhaven National Laboratory normal radiation aging 9912m,n 01/18/00-1/24/00 610 7.728E+07 6.777E+07 7.500E+07 7.500E+07 90.37% 45120-6 Brookhaven National Laboratory normal radiation aging 9912m 01/18/00-1/21/00 611 3.865E+07 3.390E+07 3.750E+071 3.750E+07 90.39% 45120-6 Brookhaven National Laboratory normal radiation aging 9912m 01/18/00-1/21/00 612 3.865E+07 3,390E+071 3.750E+071 3.750E+07-90.39% 45120-6 Brookhaven National Laboratory normal radiation aging 9912m 01/18/00-1/21/00 613 3.865E+071 3.390E+07 3,750E+071 3.750E+07 90.39% 45120-6 Brookhaven National Laboratory normal radiation aging 9912m,n 101/18/00-1/24/00 617 7.728E+071 6.777E+07 7.500E+07!

7.500E+07 90.37% 45120-6 Brookhaven National Laboratory normal radiation aging 9912m,n 101/18/00-1/24/00 618 7.728E+07 6.777E+07 7.500E+07 7.500E+071 90.37%145120-6 Brookhaven National Laboratory normal radiation aging 9912m

_01/18/00-1/21/00 619 3.865E+07:

3.390E+07 3.750E+071 3.750E+07F 90.39%145120-6 Brookhaven National Laboratory normal radiation aging 99121

_01/10/00-1/18/00 621 7.702E+071 6.755E+071 7.500E+071 7.500E+07 90.06%145120-6 Brookhaven National Laboratory normal radiation aging 99121 101/10/00-1118/00 622 7.702E+071 6.755E+071 7.500E+071 7.500E+071 90.06%145120-6 Brookhaven National Laboratory normal radiation aging 99121 01/10/00-1/18/00 1623

[

7.702E+071 6.755E+071 7.500E+071 7.500E+071 90.06% 145120-6 Brookhaven National Laborato normal radiation aging 9912m,n 01/18/00-1/24/00 624 7.728E+071 6.777E+071 7.500E+071 7.500E+071 90.37%145120-6 Brookhaven National Laborato normal radiation aging 9912m,n 01/18/00-1/2400 0 14(10605E/J605E)I 7.728E+071 6.777E+071 7.500E+071 7.500E+07!

90.37%145120-6 Brookhaven National Laboratory normal radiation aging 9912m,n 101/18/00-1/24/00 15 (10605F/J0605F)

E 7.728E+07t 6.777E+071 7.500E+071 7.500E+071 90.37% 45120-6 Brookhaven National Laboratory Tnormal radiation aging 5/6/2002 8:46 AM 5 of 7

Georgia Tech Part 21 I

Customer Actual Total Dose / I Actual Total Actual Total Wyle Required Required Dose, Customer Required GT Irradiation Period Specimen ID Dose, R Dose, rad Test Dose, rad rad Dose, %

Wyle Report No.

Customer Comments 9912m,n 01/18/00-1/24/00 16 (10605G/J0605G) 7.728E+07 6.777E+071 7.500E+071 7.500E+07 90.37% 45120-6 Brookhaven National Laboratory normal radiation aging 9912m,n 01/18/00-1/24/00 17 (10605H/J0605H) 7.728E+07 6.777E+071 7.500E+071 7.500E+07 90.37% 45120-6 Brookhaven National Laboratory normal radiation aging 9912m,n 01/18/00-1/24/00 19 (10608E/J0608E) 7.728E+07 6.777E+07 7.500E+071 7.500E-+07 90.37%145120-6 Brookhaven National Laboratory normal radiation aging 9912m,n 01/18/00-1/24/00 20 (10608F/J0608F) 7.728E+071 6.777E+071 7.500E+071 7.500E+07 90.37%145120-6 Brookhaven National Laboratory normal radiation aging 9912m,n 01/18/00-1/24/00 21 (10608G/J0608G) 7.728E+07 6.777E+07 7.500E+071 7.500E+07 90.37%145120-6 Brookhaven National Laboratory normal radiation aging 9912m,n 01/18/00-1/24/00 22 (10608H/J0608H) 7.728E+07 6.777E+07 7,500E+071 7.500E+071 90.37%145120-6 Brookhaven National Laboratory normal radiation aging 9912m 01/18/00-1/21/00 24 (10611 E/J061 1 E) 3.865E+07 3.390E+07 3.750E+071 3.750E+07 90.39% 45120-6 Brookhaven National Laboratory normal radiation aging 9912m 01/18/00-1/21100 25 (10611F/J0611F) 3.865E+07 3.390E+07 3.750E+07 3.750E+071 90.39%'45120-6 Brookhaven National Laboratory normal radiation aging 9912m 01/18/00-1/21/00 26 (10611G/J0611G) 3.865E+07 3.390E+07 3.750E+07 3.750E+071 90.39% 45120-6 Brookhaven National Laboratory normal radiation aging 9912m 01/18/00-1/21/00 27 (10611H/J0611H) 3.865E+07 3.390E+07 3.750E+071 3.750E+07 90.39% 45120-6

[Brookhaven National Laboratory normal radiation aging 9912q 43/1/00-3/6/00 30 (10621D/J0621D) 5.136E+071 4.504E+07 5,000E+07 5.OOOE+07 90.09%145120-6 jBrookhaven National Laboratory normal radiation aging 99121 101/10/00-1/18/00 31 (10621E/J0621E) 7.702E+07 6.755E+071 7.500E+071 7.500E+071 90.06%145120-6 Brookhaven National Laboratory normal radiation aging 99121 01/10/00-1/18/00 32 (10621F/J0621F) 7.702E+07 6.755E+071 7.500E+071 7.500E+071 90.06%145120-6 Brookhaven National Laboratory normal radiation aging 99121 01/10/00-1/18/00 33 (10621 G/J0621 G) 7.702E+07 6.755E+071 7.500E+071 7.500E+07 90.06% 45120-6 Brookhaven National Laboratory normal radiation aging 99121 01/10/00-1/18/00 34 (10621H/J0621H) 7.702E.+07 6.755E+07 71500E 7.

7.500E+07 90.06% 45120-6 Brookhaven National Laboratory normal radiation aging 9 9 12o,p 2/1/00-2/28/00 601 1.566E+08

. 1.373E+08 1.500E+081 1.500E+08 91.56%145120-6 Brookhaven National Laboratory accident radiation 9912o,p 2/1/00-2/28/00 602 1.566E+08 1.373E+08 1.500E+081 1.500E+08 91.56%145120-6 Brookhaven National Laboratory accident radiation 9912o 2/1/00-2/7/00 603 7.899E+07 6.927E+07 7.500E+071 7.500E+07 92.37%145120-6 Brookhaven National Laboratory accident radiation 9 912 o,p 2/1/00-2/28/00 604 1.566E+08 1.373E+08 1.500E+081 1.500E+08 91.56% 45120-6

'Brookhaven National Laboratory accident radiation 9912o,p 2/1/00-2/28/00 605 1.566E+08 1.373E+08T 1.500E+08 1 1.500E+081 91.56%145120-6 Brookhaven National Laboratory accident radiation 9912o,p 2/1/00-2/28/00 606 1,566E+08 1.373E+081 1.500E+081 1.500E+08 91.56%145120-6 Brookhaven National Laboratory accident radiation 9912o,p 2/1/00-2/28/00 607 1.566E+08 1.373E+081 1.500E+081 1.500E+08 91.56% 145120-6 Brookhaven National Laboratory accident radiation 99 12o,p 2/1/00-2/28/00 608 1.566E+08 1.373E+081 1.500E+081 1.500E+08 91.56%145120-6 Brookhaven National Laboratory accident radiation 9912o,p 2/1/00-2/28/00 609 1.566E+08 1.373E+08 1.500E+08 1.500E+081 91.56%145120-6

!Brookhaven National Laboratory jaccident radiation 9912o,p 2/1/00-2/28/00 610 1.566E+08 1.373E+08 1.500E+08 1.500E+081 91.56%145120-6

[Brookhaven National Laboratory accident radiation 9912o 2/1/00-2/7/00 611 7.899E+07 6.927E+07 7.500E+07 7.500E+07 92.37% 45120-6 Brookhaven National Laboratory laccident radiation 9912o 2/1/00-2/7/00 612 7.899E+07J 6.927E+07 7.506E+07 7.500E+07 92.37%145120-6

[Brookhaven National Laboratory accident radiation 9912o 2/1/00-2/7/00 t613 7.899E+071 6.927E+07 7.500E+07 7.500E+07 92.37%145120-6 TBrookhaven National Laboratory accident radiation 991 2o,p 2/1100-2/28/00 617 1.566E+081 1.373E+08 1.500E+08 1.500E+08 91.56%1145120-6 Brookhaven National Laboratory accident radiation 9912o,p 2/1/00-2/28/00 618 1.566E+08 1.373E+08 1.500E+08 1.500E+08 91.56%145120-6 Brookhaven National Laboratory accident radiation 9912o 2/1/00-2/7/00 619 7.899E+07 6.927E+07 7.500E+07 7.500E+07 92.37% 45120-6 Brookhaven National Laboratory accident radiation 9912o,p 2/1/00-2/28/00 621 1.566E+08 1.373E+08 1.500E+08 1.500E+08 91.56% 45120-6 Brookhaven National Laboratory accident radiation 9912o,p 2/1/00-2/28/00 622 1.566E+08 1.373E+08 1.500E+08 1.500E+08 91.56% 45120-6 Brookhaven National Laboratory accident radiation 9912o,p 2/1/00-2/28/00 623 1.566E+08 1.373E+08 1.500E+08 1.500E+08 91.56% 45120-6 Brookhaven National Laboratory accident radiation 9912o,p 2/1/00-2/28/00 1624 1.566E+081 1.373E+081 1.500E+081 1.500E+081 91.56%145120-6 Brookhaven National Laboratory accident radiation 9912o 2/1/00-2/7/00 9912o,p 12/1/00-2/28/00 9912o,p 12/1/00-2/28/00 9912o 2/1/00-2/7/00 9912o,p 12/1/00-2/28/00 9912o,p 2/1/00-2/28/00 99120 I2/1/00-2/7/00 9 9 12 o,p I2/1/00-2/28/00 9912o,p 2/1/00-2/28/00 9912o 2/1/00-2/7/00 9912o,p 12/1/00-2/28/00 1 (10601 F/J0601 F) 7.899E+071 6.927E+071 7.500E+071 7.500E+071 92.37%145120-6 Brookhaven National Laboratory jaccident radiation 2 (10601 G/J0601 G) 1.566E+081 1.373E+081 1.500E+081 1.500E+08 91.56% 45120-6 Brookhaven National Laboratory Jaccident radiation 3 (10601H/J0601 H) 1.566E+081 1.373E+08 1.500E+081 1.500E+081 91.56%145120-6 Brookhaven National Laboratory accident radiation 4 (10602F/J0602F) 7.899E+07 6.927E+07 7.500E+071 7.500E+071 92.37% 45120-6 Brookhaven National Laboratory accident radiation 5 (10602G/J0602G) 1.566E+08 1.373E+081 1.500E+081 1.500E+081 91.56% 45120-6 IBrookhaven National Laboratory accident radiation 6 (10602H/J0602H) 1.566E+081 1.373E+081 1.500E+081 1.500E+081 91.56%145120-6 Brookhaven National Laboratory accident radiation 17 (10603F/J0603F) 7.899E+07 6.927E+071 7.500E+071 7.500E+071 92.37%145120-6 Brookhaven National Laboratory jaccident radiation 8 (10603G/J0603G) 1.566E+08 1.373E+081 1.500E+08i 1.500E+081 91.56%145120-6 Brookhaven National Laboratory jaccident radiation 19 (10603H/J0603H) 1.566E+08T 1.373E+08i 1.500E+081 1.500E+081 91.56% 145120-6 Brookhaven National Laboratory laccident radiation 110 (10604F/J0604F)

[

7.899E+071 6.927E+071 7.500E+071 7.500E+071 92.37%145120-6 Brookhaven National Laboratory jaccident radiation 111 (10604G/J0604G) 1.566E+081 1.373E+081 1.500E+081 1.500E+081 91.56%145120-6 Brookhaven National Laboratory Jaccident radiation 6 of 7 5/6/2002 8:46 AM

Georgia Tech Part 21 I

Customer Actual Total Dose /

Actual Total Actual Total Wyle Required Required Dose, Customer Required GT Reference Irradiation Period Specimen ID Dose, R Dose, rad Test Dose, rad j rad Dose, %

Wyle Report No.

Customer Comments 9912o,p 2/1/00-2/28/00 12 (10604H/J0604H) 1.566E+081 1.373E+081 1.500E+08 1.500E+08 91.56% 45120-6 lBrookhaven National Laboratory accident radiation 9912o 2/1/00-2/7/00 15 (10605F/J0605F) 7.899E+07 6.927E+071 7.500E+07 7.500E+07 92.37% 45120-6 Brookhaven National Laboratory accident radiation 9912o,p 2/1/00-2/28/00 16 (10605G/J0605G) 1.566E+081 1.373E+081 1.500E+08 1.500E+081 91.56% 45120-6

'Brookhaven National Laboratory accident radiation 9912o,p 2/1/00-2/28/00 17 (10605H/J0605H) 1.566E+08 1.373E+081 1.500E+08 1.500E+081 91.56% 45120-6 Brookhaven National Laboratory accident radiation 9912o 2/1/00-2/7/00 20 (10608F/J0608F) 7.899E+07 6.927E+071 7.500E+07 7.500E+07 92.37% 45120-6 Brookhaven National Laboratory accident radiation 9912o,p 2/1/00-2/28/00 21 (10608G/J0608G) 1.566E+08 1.373E+081 1.500E+08 1.500E+08 91.56% 45120-6 1 Brookhaven National Laboratory accident radiation 9912o,p 2/1/00-2/28/00 22 (10608H/J0608H) 1.566E+08 1.373E+08!

1.500E+08 1.500E+08 91.56% 45120-6 Brookhaven National Laboratory accident radiation 9912o 2/1/00-2/7/00 25 (10611 F/J061 1 F) 7.899E+07' 6.927E+07 7.500E+07 7.500E+071 92.37%145120-6 Brookhaven National Laboratory accident radiation 9 912o,p 2/1/00-2/28/00 26 (10611G/J0611G) 1,566E+081 1.373E+08 1.500E+081 1.500E+08 91.56% 45120-6 Brookhaven National Laboratory accident radiation 9912o,p 2/1/00-2/28/00 27 (10611 H/J0611H) 1.566E+08 1.373E+08 1.500E+081 1.500E+08 91.56% 45120-6 Brookhaven National Laboratory accident radiation 9912o 2/1/00-2/7/00 32 (10621 F/J0621 F) 7.899E+07 6.927E+07 7.500E+071 7.500E+07 92.37% 45120-6 Brookhaven National Laboratory accident radiation 9912o,p 2/1/00-2/28/00 33 (10621G/J0621G) 1.566E+08 1.373E+08 1.500E+08 1.500E+08 91.56% 45120-6 Brookhaven National Laboratory accident radiation 9912o,p 2/1/00-2/28/00 34 (10621H/J0621H) 1.566E+08 1.373E+08 1.500E+08 1 1.500E+08s 91.56% 45120-6 Brookhaven National Laboratory accident radiation 7 of 7 5/6/2002 8:46 AM

Georgia Tech Part 21 I

I Customer Actual Total Dose / I Actual Total Actual Total Wyle Required Required Dose, Customer Required GT Reference Irradiation Period Specimen ID Dose, R Dose, rad Test Dose, rad rad Dose, %

Wyle Report No.

Customer Comments 9810 3/30198-3131/98 2 LED's, 1, Fire Detection Panel, 1 1.253E+05 1.099E+05 1.200E+05 1.000E+05 109.89% 45965A98-ACU Century Corporation (Formerly normal + accident TID Power Supply, 1 Temp Controller, & 1 Kyungwon-Century Co., Ltd pressure transmitter 981 5/11/98-5112/98 CR132, CR133 1.265E+05 1.109E+05 1.200E+05 1.000E+05 110.94% 45965A98-ACU Century Corporation (Formerly normal + accident TD Kyungwon-Century Co., Ltd 5/22/2002 4:56 PM 1 Of 1

Georgia Tech Part 21 5/6/2002 8:45 AM 1 of 1

Georgia Tech Part 21 GT Reference Irradiation Period 9807 13/9/98-3/11/98 9811 14/8/98-4/9/98 Specimen ID Raychem cable splice assemblies 4 coated olates Actual Total Dose, R L.L'4+UIU ZL.U4tO)rJ( IP Actual Total Dose, rad I.964E+071U i.1 ~'i z-r-tU P

Wyle Required Test Dose, rad 2.zUU*+U I 2.UUUO+0U Customer Actual Total Dose /I Required Dose, Customer Required rad Dose, %

Wyle Report No.

Customer 2.OOOE+07 98.22% 46312-1 Consumers Energy 2.OOOE+071 89.72%146945-1 Consumers Energy 1 of 1 Comments 5/6/2002 9:03 AM I

Georgia Tech Part 21 5/22/2002 4:52 PM 1 of I

Georgia Tech Part 21 Customer Actual Total Dose /

Actual Total Actual Total Wyle Required Required Dose, Customer Required GT Reference Irradiation Period Specimen ID Dose, R Dose, rad Test Dose, rad rad Dose, %

Wyle Report No.

Customer Comments 9901 1/28/99-3/5/99 two penetrations 6.693E+08 5.870E+08 6.500E+08 6.500E+081 90.31% 42245-02 D. G. O'Brien, Inc.

2001-14a 4/27/01-4/30/01 cable samples 1.447E+07 1.269E+07 1.370E+07 1.241E+07 102.26% 45439R2001-00 D. G. O'Brien, Inc.

normal + accident TID 2001-14b 4/30/01-5/01101 fiber optic penetrator 1.243E+07 1.090E+07 1.210E+07 1.100E+07 99.10% 45439R2001-00 D. G. O'Brien, Inc.

normal + accident TID 2001-14c 4/30/01-5/01/01 IC&I penetrator 1.418E+07 1.244E+071 1.370E+07 1.241E+07 100.21% 45439R2001-00 ID. G. O'Brien, Inc.

normal + accidentTID 5/6/2002 9:03 AM 1 of 1

Georgia Tech Part 21 Specimen ID 2uu -o motor 6 wood DIOCKs, twisteu wires, straignh wires. larae wire loops Actual Total Dose. R "I.U0IE+U0

2. 12-5t:+07I 1.6E0 Actual Total Dose. rad 9.UU-C+Ub Wyle Required Test Dose, rad 1.UUU*+U.

Z.uuut+uf 1.UUUEh+U7(

.qfl 07% 11001 f3*R FI=)rtrir* Pnr~r P*=rrh Infifh,+l Customer Actual Total Dose /

Required Dose, Customer Required rad Dose, %

Wyle Report No.

f I GT Reference Iirradiation Period 00-12a 1 5/4/00-5/5/00 1.uuuE+u7 9QQI 01O Electric Power Research Institute noma raiaio agin 00-12c 5/8/00-5/10/00 400 Hp motor, small loops, 2 wood 2.086E+07 1.829E+07 2.000E+07 2.000E+07 91.47% 1001036 Electric Power Research Institute normal radiation aging blocks I

1 00-22a 10/20/00-10/23/00 wood/coil blocks, twisted wire racks, 4.146E+07 3.636E+07 4.000E+07 4.000E+07 90.90% 1001036 Electric Power Research Institute accident radiation 00-22b 10/25/00-10/30/

400 hp motor frame, 22 coils 4.152E+07 3.641 E+07 4.OOOE+07 4.OOOE+07 91.03%'1001036 Electric Power Research Institute accident radiation 0 mandrels 2.058E+081 1.805E+08 2001-24 6/2-6-/01-7/6/01 2anrsI 2.8E8 1.0E+

2.OOOE+081 2.OOOE+081 90.24%11001390 Electric Power Research Institute 1 of 1 UU-iz2 i1O/uU-b/bOUU 2 (uuuF+u7 93.18% 1001036 Electric Power Research Institute 5/6/2002 9:04 AM L

-rn-nf I

Customer

  • l i*tnmAr nnrl, l, lal rO*;O(';m"*n
  • Jt'llrltl normal radiation aging

ý:j

Georgia Tech Part 21 GT Reference Irradiation Period Specimen ID 9812 4/16/98-4/17/98 5 PAR cartridges I

I I

Actual Total Actual Total Wyle Required Dose, R Dose, rad Test Dose, rad 1.021E+071 8.954E+061 1.OOOE+07 Customer Actual Total Dose /

Required Dose, Customer Required rad Dose, %

Wyle Report No.

Customer 7.600E+06 117.82% 46189, Rev. C Entergy Nuclear NE( formerly Con E.-

1 of 1

,omments I

5/22/2002 4:50 PM

Georgia Tech Part 21 I

Customer I Actual Total Dose!

Actual Total Actual Total Wyle Required Required Dose, Customer Required GT Reference Irradiation Period Specimen ID Dose, R Dose, rad Test Dose, rad rad Dose, %

Wyle Report No.

Customer Comments 00-06 3/9/00-3/14/00 1 pipe insulation sample 1.033E+081 9.059E+071 1.000E+08 1.OOOE+08 90.59% 44037 C of C No. 1 Entergy Operations, Inc.

5/6/2002 9:04 AM 1 of 1

Georgia Tech Part 21 Customer Actual Total Dose /

Actual Total Actual Total Wyle Required Required Dose, Customer Required GT Reference Irradiation Period Specimen ID Dose, R Dose, rad Test Dose, rad rad Dose, %

Wyle Report No.

Customer Comments 2001-18 5/14/01-5/14/01 3 Valtek actuators 4.873E+061 4.274E+061 4.740E+06 4.740E+061 90.16% 44388R02 Flowserve normal radiation aging 5/6/2002 9:30 AM 1 of 1

Georgia Tech Part 21 Customer Actual Total Dose I Actual Total Actual Total Wyle Required Required Dose, Customer Required GT Reference Irradiation Period Specimen ID Dose, R Dose, rad Test Dose, rad rad Dose, %

Wyle Report No.

Customer Comments00-15a 6/7/00-6/8/00 20 gaskets, 3 small terminal blocks, 1 1.131E+07 9.919E+06 1.100E+07 1.OOOE+07 99.19% 43137R01, Rev. A Hyosung Corporation normal + accident TID gallon grease 00-15b 6/8/00-6/9/00 6 bearings, 3 terminal blocks 1.135E+07 9.954E+06 1.100E+07 1.000E+07 99.54% 43137R01, Rev. A Hyosung Corporation normal + accident TID 00-15c 6/9/00-6/12/00 two 50 Hp motors 1.185E+07 1.039E+07 1.100E+07 1.000E+07 103.92% 43137R01, Rev. A Hyosung Corporation normal + accident TID 00-15d 6/12/00-6/14/00 two 7.5 Hp motors 1.138E+071 9.980E+061 1.100E+07 1.OOOE+07 99.80% 43137R01, Rev. A Hyosunq Corporation normal + accident TID 5/6/2002 9:30 AM I of 1

Georgia Tech Part 21 5/6/2002 9:30 AM 1 of I

Georgia Tech Part 21 GT Reference Irradiation Period Specimen ID 9816 5/26/98-6/8/98 1 cable tray Actual Total Dose, R 2.042E+08 Actual Total Wyle Required Dose, rad I Test Dose, rad 1.7912E+08 2.0002+08 Customer Actual Total Dose /

Required Dose, Customer Required rad Dose, %

Wyle Report No.

Customer 2.000E+08I 89.54% 46979-1 Promatec Technoloaies Inc 1 of 1 Comments 4

1.791E+081 2 OOOE+081 5/6/2002 9:31 AM

Georgia Tech Part 21 5/22/2002 4:50 PM Customer Actual Total Dose /

Actual Total Actual Total Wyle Required Required Dose, Customer Required GT Reference Irradiation Period Specimen ID Dose, R Dose, rad Test Dose, rad rad Dose, %

Wyle Report No.

Customer Comments00-17a 7/14/00-7/25/00 mandrels 2,4,8,13,15 1.696E+08 1.487E+08 1.650E+08 1.500E+08 99.16% 43854 report not Raychem/Tyco Electronics Corp accident radiation issued as of 4-22 2002 00-17b 7/27/00-8/11/00 mandrels 1, 3, 6, 12, 14 2.239E+08 1.964E+08 2.150E+08 2.OOOE+08 98.18% 43854 report not Raychem/Tyco Electronics Corp normal 40 y + accident TID issued as of 4-22 2002 00-17b,c 7/27/00-8/18/00 mandrel 5 2.490E+08 2.184E+08 2.400E+08 2.250E+08 97.05% 43854 report not Raychem/Tyco Electronics Corp normal 60 y + accident TID issued as of 4-22 2002 00-17d 8/29/00-9/11/00 trays 3, 6 1.697E+08 1.488E+08 1.650E+08 1.500E+08 99.22% 43854 report not Raychem/Tyco Electronics Corp accident radiation issued as of 4-22 2002 00-17e,f 9/21/00-10/9/00 trays 1, 2, 4, 5, 7 2.225E+08 1.951E+08 2.150E+08 2.OOOE+08 97.57% 43854 report not Raychem/Tyco Electronics Corp normal 40 y +accident TD issued as of 4-22 12002 00-17g 10/13/00-10/16/00 tray 8 4.071E+07 3.570E+07 3.960E+07 3.960E+07 90.16% o 243854 report not Raychem/Tyco Electronics Corp issued as of 4-22 200200 1 of I

Georgia Tech Part 21 I

/-Customer Actual Total Dose /

Actual Total Actual Total Wyle Required Required Dose, Customer Required GT Reference Irradiation Period Specimen ID Dose, R Dose, rad Test Dose, rad rad Dose, %

Wyle Report No.

Customer Comments 97-17 11121/97-11/26/97 SXM-1 5.233E+07 4.589E+07 5.OOOE+07 5.OOOE+07 91.78% 45925-1 Schulz Electric Company normal radiation aging 97-17 11/21/97-11126/97 SXM-2 5.223E+07 4.580E+07 5.OOOE+07 5.OOOE+07 91.60% 45925-1 Schulz Electric Company normal radiation aging 97-17 11121/97-11/26/97 SXM-3 5.230E+07 4.587E+07 5.OOOE+07 5.600E+07 91.73% 45925-1 Schulz Electric Company normal radiation aging 97-17 11/21/97-12/18/97 SXM-4 5.135E+07 4.503E+07 5.OOOE+07 5.OOOE+07 90.07% 45925-1 Schulz Electric Company normal radiation aging 97-17 11/21/97-12/18/97 SXM-5 6.025E+07 5.284E+07 5.OOOE+07 5.OOOE+07 105.68% 45925-1 Schulz Electric Company normal radiation aging 97-17, 11/21/97-12/12/97 SXM-7 5.105E+07 4.477E+07 5.OOOE+07 5.OOOE+07 89.54% 45925-1 Schulz Electric Company normal radiation aging 97-17 12/15/97-12/17/97 Motor Frame 8 (SXM-8, SXM-9, SXM-2.042E+07 1.791E+07 2.OOOE+07 2.OOOE+07 89.54% 45925-1 Schulz Electric Company normal radiation aging 10, & SXM-11) 1 9817 7/1/98-7/23/98 SXM-7, SXM-2 1.729E+08 1.516E+081 1.694E+08 1.540E+08 98.46% 45925-1 Schulz Electric Company accident radiation 9817 7/1/98-7/23/98 Motor Frame 8 (SXM-8, SXM-9, SXM-4.492E+07 3.939E+07 4.400E+07 4.OOOE+07 98.49% 45925-1 Schulz Electric Company accident radiation 10, & SXM-11)

I I

I 5/6/2002 9:31 AM 1 of 1

Georgia Tech Part 21 Customer Actual Total Dose /i Actual Total Actual Total Wyle Required Required Dose, Customer Required GT Reference Irradiation Period Specimen ID Dose, R Dose, rad Test Dose, rad rad Dose, %

Wyle Report No.

Customer Comments 9813a 4/21/98-4/24/98 1

2.975E+07 2.609E+07 3.000E+07 3.000E+07 86.97% 46656-1, Rev. A Weed Instrument Company, Inc.

981 3a-b 4/21/98-4/30/98 2

6.956E+07 6.100E+07 6.800E+07 6.800E+07 89.71% 46656-1, Rev. A Weed Instrument Company Inc.

9813a 4/21/98-4/24/98 3

3.097E+07 2.716E+07 3.OOOE+07 3.000E+07 90.54% 46656-1, Rev. A Weed Instrument Company, Inc.

9813a-e 4/21/98-5/8/98 4

2.043E+08 1.792E+08 2.000E+08 2.000E+08j 89.59% 46656-1, Rev. A Weed Instrument Company, Inc.

9813a-b 14/21/98-4/30/98 5

6.944E+07 6.090E+07 6.800E+07 6.800E+071 89.56% 46656-1, Rev. A Weed Instrument Company, Inc.

9813a 14/21/98-4/24/98 6

3.029E+07 2.657E+07 3.000E+071 3.OOOE+071 88.56% 46656-1, Rev. A Weed Instrument Company, Inc.

9813a-b 14/21/98-4/30/98 7

7.078E+07 6.207E+07 6.800E+071 6.800E+07 91.29% 46656-1, Rev. A Weed Instrument Company, Inc.

9813a-b 14/21/98-4/30/98

-8 6.985E+07 1 6.126E+07 6.,V+OV, 6.80vE-40 90.09% 46656-1, Rev. A Weed Instrument Company, Inc.

9813a 14/21/98-4/24/98 9

3.055E+07 2.679E+07 3.000E+071 3.000E+07 89.31% 46656-1, Rev. A Weed Instrument Company, Inc.

9813a 4/21/98-4/24/98 10 3.004E+07 2.634E+07 3.OOOE+071 3.000E+07 87.81% 46656-1, Rev. A Weed Instrument Company, Inc.

9813a-b 4/21/98-4/30/98 11 7.009E+07 6.147E+07 6.800E+07 6.800E+07 90.40% 146656-1, Rev. A Weed Instrument Company, Inc.

9813a-e 4/21/98-5/8/98 12 2.045E+08 1.793E+08 2.OOOE+081 2.OOOE+08 89.67% 146656-1, Rev. A Weed Instrument Company, Inc.

9822 8/17/98-8/24/98 2

1.367E+08 1.199E+08 1.300E+08[

1.300E+08 92.22% 46656-1, Rev. A Weed Instrument Company, Inc.

CP proj numbers start here 9822 8/17/98-8/24/98 11 1.361E+08 1.194E+08 1.300E+081 1.300E+08 91.82% 146656-1, Rev. A Weed Instrument Company, Inc.

9908a 6/23/99-6/30/99 4, 5, 6, 10, 15, 21 1.136E+08 9.963E+07 1.100E+08 1.100E+081 90.57% 42692-1, Rev. A Weed Instrument Company, Inc.

9908a,b,c 6/23/99-7/6/99 2, 8, 12, 13, 14,18, 22, 23 2.0764E+081 1.8210E+081 2.000E+081 2.OOOE+08 91.05% 42692-1, Rev. A Weed Instrument Company, Inc.

I of 1 516/2002 9:31 AM