AmerGen, An Exelon/British Energy Company AmerGen Energy Company, LLC Oyster Creek US Route 9 South P.O. Box 388 Forked River, NJ o8731-0388 10 CFR 72.212(b)(1)(i)
May 10, 2002 2130-02-20018 United States Nuclear Regulatory Commission Document Control Desk Washington DC 20555
Subject:
Oyster Creek Generating Station Docket 50-219 Registration of Independent Spent Fuel Storage Installation Casks No. 1 and No. 2 In accordance with 10 CFR 72.212(b)(1)(i), this letter dockets the use of the following casks in the Oyster Creek Generating Station Independent Spent Fuel Storage Installation:
Cask Certificate No.
72-1004 (Amendment 4) 72-1004 (Amendment 4)
Cask Model No.
NUHOMS-61BT NUHOMS-61BT Cask ID No.
OCG61B-001-C OCG611B-002-C Date Loaded 04/11/2002 04/23/2002 Additionally, the following thermal performance data was collected:
Cask / Horizontal Storage Module No.
Decay Heat Load Forecast Temperature Rise Actual Temperature Rise OCG61B-C/HSM-915-001 8.9 KW 45 degrees F 22 degrees F OCG61B-C/HSM-915-002 8.97 KW 45 degrees F 21 degrees F If any further information or assistance is required, please contact Mr. John Rogers of my staff at 609.971.4893.
Very truly yours, Ron J. DeGregorio, Vice President Oyster Creek Generating Station RJD/JJR cc:
Administrator, Region I NRC Senior Project Manager NRC Senior Resident Inspector f' ý