ST. LUCIE POWER PLANT FPL/NRC License Renewal Application Overview Meeting January 16, 2002
AGENDA
"* Introduction
"* Application Overview
"* Discussion 2
"APPLICATION OVERVIEW
- Application follows SRP Format
- Chapter 1 - Administrative Information
- Chapter 2 - SCs Subject to AMR (Scoping/Screening)
- Chapter 3 - Aging Management Reviews (AMRs)
- Chapter 4 - Time Limited Aging Analyses (TLAAs) 3
APPLICATION OVERVIEW
- Application follows SRP Format (continued)
- Appendix A - UFSAR Supplement
- Appendix B - Aging Management Programs (AMPs)
- Appendix C - AMR Process for Non Class 1 Components
- Appendix D - Technical Specification Changes
- Environmental Report - Operating License Renewal Stage
- Incorporated results of NRC review of the Turkey Point license renewal application as appropriate and available 4
Ito
- Source Documents
- UFSAR and Technical Specifications
- Licensing Correspondence
- Design Basis Documents
- Component Database
- Drawings
- Other 5
APPLICATION OVERVIEW
APPLICATION OVERVIEW 9 Scoping and Screening Methodology
- Described in Section 2.1
- Methodology used for St. Lucie the same as that used for Turkey Point
- Follows the approach recommended in NEI 95-10
- Implemented in accordance with FPL's Quality Assurance Program 6
APPLICATION OVERVIEW 9 Scoping
- Results presented in Section 2.2
- 39 of 70 Systems in Scope
- 16 of 46 Structures in Scope
- Plant layout figures included for location of plant structures 7
APPLICATION OVERVIEW e Screening
- Mechanical Sections
"* RCS and Connected Systems
"* ESF Systems
"* Auxiliary Systems
"* Steam and Power Conversion
-Justification for boundaries at open valves and components provided
- Seismic interaction approach is consistent with that used for Turkey Point 8
APPLICATION OVERVIEW 9 Screening (continued)
- Structures and Structural Components Sections
"* Containments
"* Other structures (fire rated assemblies treated as a separate structure)
-Table 3.5-1 provides structural component intended function key for 6 column tables
-Structural components performing a pressure boundary function for ventilation or fire protection are identified 9
APPLICATION OVERVIEW 9 Screening (continued)
Component/commodity groups included with structures:
- Structural steel framing and components
- Reinforced concrete (reinforcing/embedded steel included with concrete)
- Masonry walls
- Safety related and non-safety related component, piping, tubing and HVAC duct supports
- Pipe whip restraints
- Piping segments between class break and anchor
- Intake/exhaust hoods, louvers, and missile barriers
- Electrical conduits, cable trays, instrument panels and enclosures, and associated supports
- Passive components of cranes
- Air tight and water tight doors and seals
- Weatherproofmg 10
APPLICATION OVERVIEW
- Screening (continued)
- Electrical and I&C Section
- Component Commodity Groups
- Results in 6 column tables in Chapter 3 License Renewal Boundary Drawings and UFSAR references provided I1
APPLICATION OVERVIEW
- Aging Management Reviews
- Application Chapter 3 and Appendix B
- Same groupings as screening
- Results presented in 6 column tables
- Technical guidance/criteria for aging effects for non-class 1 components described in Appendix C
- Electrical design features are the same as Turkey Point (lead sheathed cable, outdoor areas, etc.)
12
APPLICATION OVERVIEW e Aging Management Reviews (continued)
GALL Report Comparisons e Differences between GALL component/commodity group listings and St. Lucie screening results identified and evaluated 9 Differences in materials and internal and external environments identified e GALL Report reference is provided in 6 column tables when the component/commodity group, material, and environment are the same
- Aging management programs consistent with GALL identified 13
GALL COMPARISON EXAMPLES 3.2 ENGINEERED SAFETY FEATURES SYSTEMS The following systems........
Subsection 2.3.2 provides........
The aging management review........
The Engineered Safety Features Systems scoping, screening, and aging management review results were compared to the GALL Report [Reference 3.2-1]. The following component/commodity groups Identified In the GALL Report do not require an aging management review for St. Lucie Units I and 2 for the reasons noted.
Containment Spray Heat Exchangers (V A.6) - The St. Lucie Units I and 2 design do not contain these components. The St. Lucie designs utilize the shutdown cooling heat exchangers to perform this function.
"* Refueling Water Tank Circulation Pumps (V D1.3) - The St. Lucie Units 1 and 2 designs do not contain these components.
"* Refueling Water Tank Heating Heat Exchangers (V D1.6) - The St.
Lucie Units 1 and 2 designs do not contain these components.
"* Primary Containment Heating and Ventilation System Filters (VII F3.4) - The St. Lucie Units 1 and 2 designs do not contain these components.
Additionally, the GALL Report does not address systems/subsystems included in Containment Post Accident Monitoring.
14
GALL COMPARISON EXAMPLES 3.2.1 MATERIALS AND ENVIRONMENTS The Engineered Safety Features Systems are exposed to internal environments of......
For corresponding component/commodity groups included in the GALL Report, FPL identified the following additional environments at St. Lucie Units I and 2:
"* Internal environment of treated water - other for Containment Spray valves, thermowells, orifices, and piping and fittings
"* Internal environment of raw water - valves, piping, and fittings associated with the reactor cavity sumps (included as part of Containment Spray)
"* Internal environment of air/gas for Containment Isolation valves, piping, and fittings
"* Internal environment of air/gas for refueling water tanks and safety injection tanks The tanks, pumps, heat exchangers, piping, tubing, and associated components and commodity groups for these systems are constructed of....
For corresponding component/commodity groups included in the GALL Report, FPL identified the following additional material applications at St.
Lucie Units I and 2:
"* Nickel alloy utilized for piping
"* Aluminum and fiberglass reinforced vinyl ester utilized for the Unit 1 refueling water tank
"* Brass utilized for valves
"* Stainless steel utilized for spray nozzles, bolting, and safety injection tanks 15
GALL COMPARISON EXAMPLES TABLE 3.2-4 SAFETY INJECTION Component I Commodity Group Aging Effect Requiring
[GALL Reference]
Intended Function Material Environment Management ProgramlActivity Internal Environment Safety injection tanks Pressure boundary Stainless steel Treated water -
Loss of material Chemistry Control Program
[V D1.7.3]
borated Cracking Air/gas None None required Low pressure safety Pressure boundary Stainless steel Treated water -
Loss of material Chemistry Control Program injection pumps borated Cracking
[V D1.2.1]
High pressure safety Pressure boundary Stainless steel Treated water -
Loss of material' Chemistry Control Program injection pumps borated
[V D1.2.1]
Shutdown cooling heat Pressure boundary Stainless steel Treated water -
Loss of material Chemistry Control Program exchanger tubes Heat transfer borated Fouling
[V D1.5.2]
(inside diameter)
Fouling
_______________Cracking Treated water -
Loss of material Chemistry Control Program other Fouling (outside diameter)
Shutdown cooling heat Pressure boundary Carbon steel clad Treated water -
Loss of material Chemistry Control Program exchanger tube sheets with stainless borated Cracking steel Treated water -
Loss of material Chemistry Control Program other Galvanic Corrosion Susceptibility Inspection Program 16
GALL COMPARISON EXAMPLES TABLE 3.2-4 (continued)
SAFETY INJECTION Component I Commodity Group Aging Effect Requiring
[GALL Reference]
Intended Function Material Environment Management ProgramlActivity Internal Environment (continued)
Shutdown cooling heat Pressure boundary Stainless steel Treated water -
Loss of material Chemistry Control Program exchanger channel borated Cracking nozzles, channel facings, channel cover facings
[V D1.5.1]
Shutdown cooling heat Pressure boundary Carbon steel Treated water -
Loss of material Chemistry Control Program exchanger shells, other Galvanic Corrosion baffles, tube supports Susceptibility Inspection
[V D13.5.3]
Program Unit I low pressure Pressure boundary Stainless steel Treated water -
Loss of material Chemistry Control Program safety injection pump Heat transfer borated Fouling cooler tubes (inside diameter)
[V D1.5.2]
Cracking Treated water -
Loss of material Chemistry Control Program other Fouling (outside diameter)
Unit 1 low pressure Pressure boundary Cast iron Treated water -
Loss of material Chemistry Control Program safety injection pump other Galvanic Corrosion cooler shells Susceptibility Inspection
[V D1.5.41 Program High pressure safety Pressure boundary Stainless steel Treated water -
Loss of material Chemistry Control Program injection pump cooler Heat transfer borated Fouling tubes (inside diameter)
[V D1.5.2]
Treated water -
Loss of material Chemistry Control Program other Fouling (outside diameter) 17
GALL COMPARISON EXAMPLES 18 Unit I high pressure Pressure boundary Cast iron Treated water -
Loss of material Chemistry Control Program safety injection pump other Galvanic Corrosion cooler shells Susceptibility Inspection IV D1.5.4]
Program Unit 2 high pressure Pressure boundary Carbon steel Treated water -
Loss of material Chemistry Control Program safety injection pump other Galvanic Corrosion cooler shells Susceptibility Inspection
[V D1.5.31 Program Unit I high pressure Pressure boundary Brass Treated water -
Loss of material Chemistry Control Program safety injection pump other Galvanic Corrosion cooler tube shields Susceptibility Inspection Program Valves Pressure boundary Stainless steel Treated water -
Loss of material Chemistry Control Program
[V D1.4.11 borated Cracking 1 Piping/Fttings
[V D1.1.1 - D1.1.51 Thermowells Tubing/fittings Valves Pressure boundary Stainless steel Air/gas None None required Piping/fittings Tubing/fittings Orifices Pressure boundary Stainless steel Treated water -
Loss of material Chemistry Control Program
[V D1.2.3]
Thottling borated Cracking 1
GALL COMPARISON EXAMPLES TABLE 3.2-4 (continued)
SAFETY INJECTION Component I Commodity Group Aging Effect Requiring
[GALL Reference]
Intended Function Material Environment Management ProgramlActivlty External Environment Safety injection tanks Pressure boundary Stainless steel Containment air None None required High pressure safety Pressure boundary Stainless steel Indoor - not air None None required injection pumps conditioned Low pressure safety Pressure boundary Stainless steel Indoor - not air None None required injection pumps conditioned Shutdown cooling heat Pressure boundary Carbon steel Indoor - not air Loss of material Systems and Structures exchanger shells conditioned Monitoring Program IV D1.5.31 Borated water leaks Loss of material Boric Acid Wastage Surveillance Program Shutdown cooling heat Pressure boundary Carbon steel Indoor - not air Loss of material Systems and Structures exchanger channel conditioned Monitoring Program heads and channel Borated water leaks Loss of material Boric Acid Wastage covers Surveillance Program Unit I low pressure Pressure boundary Cast iron Indoor - not air Loss of material Systems and Structures safety injection pump conditioned Monitoring Program cooler shells Borated water leaks Loss of material Boric Acid Wastage IV D1.5.4]
Surveillance Program Unit I high pressure Pressure boundary Cast iron Indoor - not air Loss of material Systems and Structures safety injection pump conditioned Monitoring Program cooler shells Borated water leaks Loss of material Boric Acid Wastage
[V D1.5.4)
Surveillance Program Unit 2 high pressure Pressure boundary Carbon steel Indoor - not air Loss of material Systems and Structures safety injection pump conditioned Monitoring Program cooler shells Borated water leaks Loss of material Boric Acid Wastage
[V D1.5.3]
Surveillance Program 19
GALL COMPARISON EXAMPLES 3.
2.1 CONCLUSION
The review of industry information, NRC generic communications, and St.
Lucie Units I and 2 operating experience identified no additional aging effects beyond those discussed In Subsection 3.2.2. Tables 3.2-1 through 3.2-5 contain the results of the aging management review for the Engineered Safety Features Systems and summarize the aging effects requiring management.
The aging effects requiring management are adequately managed by the following programs:
St. Lucie programs consistent with the corresponding programs in the GALL Report:
"* ASME Section Xl, Subsections IWB, IWC, and IWD Inservice Inspection Program
"* Boric Acid Wastage Surveillance Program
"* Chemistry Control Program St. Lucie plant-specific programs:
"* Galvanic Corrosion Susceptibility Inspection Program
"* Periodic Surveillance and Preventive Maintenance Program
"* Systems and Structures Monitoring Program Based on the evaluations provided in Appendix B for the programs listed above, aging effects are adequately managed so that the Intended functions of the Engineered Safety Features Systems components listed in Tables 3.2 1 through 3.2-5 are maintained consistent with the St. Lucie Units 1 and 2 CLBs for the period of extended operation.
20
APPLICATION OVERVIEW e Time Limited Aging Analyses (TLAAs)
- Reactor Vessel Embrittlement
- 40 year design cycles determined to be conservative and bounding for the extended period of operation
- The approach to EAF is consistent with that used for Turkey Point
- EQ
- Incorporated lessons learned from the Turkey Point review Wear cycle aging Classification of EQ TLAAs (ii vs. i)
Temperature and radiation monitoring
- Containment Penetration Fatigue 21
APPLICATION OVERVIEW
- TLAAs (continued)
- RCS Piping Leak Before Break
- Crane Fatigue
- Unit 1 Core Support Barrel Repair
- Alloy 600 Instrument Nozzle Repairs
- No time bound license exemptions identified 22
APPLICATION OVERVIEW
- Appendix A - UFSAR Supplements (Al for St. Lucie Units 1 and A2 and 2, respectively)
- Submitted markups with application
- New Chapter 18 for each UFSAR
"* AMP descriptions
"* TLAA descriptions
- Program commitment dates identified 23
APPLICATION OVERVIEW
- Aging Management Programs (AMPs)
- For each aging effect requiring management, AMPs are identified
- Descriptions and attribute evaluations provided in Appendix B
- 10 attribute evaluations for plant-specific programs
- "Operating Experience and Demonstration" attribute evaluations for GALL programs (other attributes are evaluated as appropriate)
- Quality assurance requirements and corrective action program discussed in Section 2.0 of Appendix B 24
APPLICATION OVERVIEW e AMPs (continued) 3 categories of AMPs
- 8 Existing (5 GALL, 3 plant-specific)
- 8 Modified Existing (4 GALL, 4 plant-specific)
- 6 New (1 GALL, 5 plant-specific) 25
APPLICATION OVERVIEW Existing AMPs consistent with GALL
" ASME Section XI, Subsection IWE Inservice Inspection Program (GALL programs XI.S 1 and XI.S4)
- St. Lucie program includes Appendix J testing in IWE program
"* ASME Section XI, Subsection IWF Inservice Inspection Program (GALL program XI.S3)
"* Chemistry Control Program (includes 3 subprograms)
- Water Chemistry Control Subprogram (GALL program XI.M2)
- Closed-Cycle Cooling Water System Chemistry Subprogram (GALL program XI.M2 1) e Fuel Oil Chemistry Subprogram (plant-specific) 26
APPLICATION OVERVIEW Existing AMPs consistent with GALL (continued)
- Environmental Qualification Program (GALL program X.E 1)
- Steam Generator Integrity Program (GALL program XI.M19) 9 St. Lucie program includes additional secondary side activities 27
APPLICATION OVERVIEW Modified existing AMPs consistent with GALL
"* ASME Section XI, Subsections IWB, IWC, and IWD Inservice Inspection Program (GALL program XI.M1) 9 Includes enhancements suggested by NRC for Turkey Point
"* Boraflex Surveillance Program (GALL program XI.M22)
- Includes enhancement for areal density testing
"* Boric Acid Wastage Surveillance Program (GALL program XI.M10)
- St. Lucie program includes more systems than GALL
"* Flow Accelerated Corrosion Program (GALL program XI.M 17)
- Includes enhancements for small bore steam trap and drain lines 28
APPLICATION OVERVIEW
- New AMP consistent with GALL
- Thermal Aging Embrittlement of Cast Austenitic Stainless Steel (CASS) Program (GALL program XI.M 12) 29
APPLICATION OVERVIEW 9 Appendix C - Non-Class 1 Component AMR Process
- Not required by regulation
- Includes technical discussions regarding SCC, bolting, high cycle fatigue, etc.
- Addresses various RAIs associated with previous license renewal applications
- Follows B&W/EPRI Tools Methodology adapted to St.
Lucie
- Appendix D - Technical Specification Changes 30
APPLICATION OVERVIEW
- Environmental Report
- Refurbishment
- Water Sources
- Evaluation against alternatives
- License Renewal option is lowest impact option 31
DISCUSSION
"* Discussion
"* Questions
"* Closing 32
LICENSE RENEWAL PROJECT
- St. Lucie License Renewal Project Team
- Project Manager-Liz Abbott
- Licensing/Design Basis -Steve Hale (primary contact)
- Mechanical-Jack Hoffman
- Civil/Structural-Bruce Beisler
- Electrical/I&C-Fidel Prieto
- Environmental Report-Tom Abbatiello 33
UNIT 1 AND 2 DIFFERENCES
- Scoping/Screening - Safety Related
"* System design - Feedwater, Ventilation, and Post Accident Sampling
"* Spent Fuel Cooling
"* Radiological consequences of fuel handling accidents Unit 2 fuel handling equipment is within the scope of license renewal
"* External missile design - Unit 2 Component Cooling Water area, Condensate Storage Tank, and Emergency Diesel Generator Fuel Oil Storage Tanks are enclosed
"* Unit 1 Turbine Building contains two safety related motor-operated valves and associated power cables 34
UNIT 1 AND 2 DIFFERENCES Scoping/Screening - Non-Safety Related which can Affect Safety Related
"* Condensate Storage Tank cross-connect piping for Unit 1
"* Non-safety related Demineralized Water piping in the Unit 2 Emergency Diesel Generator Buildings was designed Seismic Category I to prevent interaction with safety related equipment 35
UNIT 1 AND 2 DIFFERENCES Scoping/Screening - Regulated Events
" Fire Protection
- Fire pumps are common to both units but are powered from Unit 1
- Unit 1 design includes Halon suppression for the Cable Spreading Room
- Unit 2 design credits Primary Water for in-Containment hose station water supply
"* Station Blackout
- Unit 1 design credits the Unit 2 Emergency Diesel Generators as alternate AC sources. Unit 2 is a DC coping plant
- Unit 1 requires Instrument Air which utilizes a small portion of Turbine Cooling Water for cooling 36
1/2 *,UNIT 1 AND 2 DIFFERENCES Aging Management Reviews
"* Unit 1 Steam Generators replaced in 1997
"* Refueling Water Tank material
- Unit 1 - Aluminum
- Unit 2 - Stainless steel
"* Spent Fuel Storage Racks - Unit 2 does not contain Boraflex inserts
- TLAAs
- Unit 1 Core Support Barrel 37