Document Transmittal Form TO
- NRC C/O PINCKNEY, DAVID ID: EPIP059 DOCUMENT CONTROL DESK WASHINGTON, DC 20555 Date:
05/21/2002 Please update your controlled set of documents with the following documents:
Document ID Revision Status Quantity Format RecNo PRCI NC.EP-EP.ZZ-03131000 PRCI NC.EP-EP.ZZ-03091000 PRCI EPIP-TOC-COMMONO000 3
A 23 A
1 1
H 138014 H
138042 H
138086 This acknowledgement receipt must be returned to:
Document Management PSEG Nuclear PO Box 236 Hancocks Bridge, NJ 08038 MC N04 Your signature below verifies that:
(1) the above documents have been filed and superseded documents have been removed and destroyed or clearly marked as obsolete.
(2) the mailing address and copyholder information are correct or corrections have been identified on this transmittal.
[
Place checkmark here to be removed from controlled distribution Signature:
Date:
K
PSEG NUCLEAR ONSITE IMPLEMENTING PROCEDURES May 21, 2002 CHANGE PAGES FOR REVISION #23 The Table of Contents forms a
general guide to revision of each section of the Onsite EPEPs.
The are made in this TOC Revision #23 are shown below.
that your revision packet is complete and remove material listed below:
ADD the current changes that Please check the outdated REMOVE Description Rev.
Paqe Description ALL TOC NC.EP-EP.ZZ-0309 NC.EP-EP.ZZ-0313 23 03 00 ALL TOC NC. EP-EP. ZZ-0309 313 is a new procedure.
Salem facilities should use the Green 313
- tab, Hope Creek facilities should use the Blue tab.
Common facilities may use either color tab.
EPEP-AIJJ Pace Rev.
22 02 1 of 1 Paae Descrir)tion
EMERGENCY PLAN ONSITE IMPLEMENTING(
w TABLE OF CONTENTS
%-Ihl JL May 21, 2002 P(
DV/
IJUI I STATION PROCEDURES Revision Number Number Pages EPIP T.O.C.
Pg. 1 of 2 Effective Date NC.EP-EP.ZZ-0101 (Q)
NC.EP-EP.ZZ-0102 (Q)
NC.EP-EP.ZZ-0201 (Q)
NC.EP-EP.ZZ-0202 (Q)
NC.EP-EP.ZZ-0203 (Q)
EPIP 204H EPIP 204S HC.EP-EP.ZZ-0205 (Q)
SC.EP-EP.ZZ-0205 (Q)
HC©.EP-EP.ZZ-0301(Q)
SC.EP-EP. ZZ-0301 (Q)
ACTIONS REQUIRED AT UNAFFECTED STATION EMERGENCY COORDINATOR
RESPONSE
TSC -
INTEGRATED ENGINEERING RESPONSE OPERATIONS SUPPORT CENTER (OSC)
ACTIVATION AND OPERATIONS ADMINISTRATIVE SUPPORT/
COMMUNICATION TEAM RESPONSE -
TSC EMERGENCY RESPONSE CALLOUT/PERSONNEL RECALL EMERGENCY RESPONSE CALLOUT/PERSONNEL RECALL TSC -
POST ACCIDENT CORE DAMAGE ASSESSMENT TSC -
POST ACCIDENT CORE DAMAGE ASSESSMENT SHIFT RADIATION PROTECTION TECHNICIAN
RESPONSE
SHIFT RADIATION PROTECTION TECHNICIAN
RESPONSE
15 12/18/2001 01 04 04 04 03 55 55 03 02 02 03 22 11/09/2001 23 02/06/2002 28 03/14/2002 15 03/14/2002 27 26 02/28/2002 02/28/2002 39 02/06/2002 82 02/06/2002 21 05/24/2001 35 05/24/2001 EPIP-TOC-COMMON Rev.
23
EPIP T.O.C.
Pg.
2 of 2 PSEG NUCLEAR LLC EMERGENCY PLAN ONSITE IMPLEMENTING PROCEDURES TABLE OF CONTENTS May 21, 2002 Revision Number Number Pages Effective Date NC.EP-EP.ZZ-0302 (Q)
NC.EP-EP.ZZ-0303 (Q)
NC.EP-EP.ZZ-0304 (Q)
NC.EP-EP.ZZ-0305 (Q)
NC.EP-EP.ZZ-0306 (Q)
NC.EP-EP.ZZ-0307 (Q)
NC.EP-EP.ZZ-0308 (Q)
NC.EP-EP.ZZ-0309(Q)
NC.EP-EP.ZZ-0310 (Q)
NC.EP-EP.ZZ-0311 (Q)
NC.EP-EP.ZZ-0312 (Q)
RADIOLOGICAL ASSESSMENT 04 COORDINATOR RESPONSE CONTROL POINT -
01 RADIATION PROTECTION RESPONSE OPERATIONS SUPPORT CENTER (OSC)
RADIATION PROTECTION RESPONSE POTASSIUM IODIDE (KI)
ADMINISTRATION 05 00 EMERGENCY AIR SAMPLING 00 PLANT VENT SAMPLING 01 19 05/24/2001 25 09/14/2000 22 03/19/2002 10 02/29/2000 12 02/29/2000 13 03/14/2002 16 PERSONNEL/VEHICLE 00 SURVEY AND DECONTAMINATION DOSE ASSESSMENT (MIDAS)
INSTRUCTIONS 03 RADIATION PROTECTION 03 SUPERVISOR -
OFFSITE AND FIELD MONITORING TEAM RESPONSE CONTROL POINT CHEMISTRY RESPONSE CHEMISTRY SUPERVISOR -
01 02 02/29/2000 44 05/21/2002 47 05/24/2001 17 01/09/2001 25 01/09/2001 CP/TSC RESPONSE NC.EP-EP.ZZ-0313(Q)
ADVANCED DOSE ASSESSMENT (MIDAS)
INSTRUCTIONS 00 39 05/21/2002 EPIP-TOC-COMMON Rev.
2 3
PSEG NUCLEAR LLC Page 1 of 1 NC.EP-EP.ZZ-0309 (Q)
Rev. 03 DOSE ASSESSMENT (MIDAS) INSTRUCTIONS USE CATEGORY: 11 PSE&G REVISION
SUMMARY
- 1. This revision satisfies the requirement for a biennial review.
CP#IKUL COPY # --
1
- 2. This procedure consists of the standard instructions to perform dose assessment (MIDAS). The advanced MIDAS instructions that previously were contained in NC.EP-EP.ZZ-0309(Q) were moved to a separate procedure [NC.EP-EP.ZZ 0313(Q)]. Portions of this procedure were reformatted due to the removal of the advanced instructions and to enhance the user friendliness of this procedure. No revision bars were used, due to the extensive reformatting.
- 3. Steps 5.6.16 and 5.7.31.N were revised to tell the user to enter 20 for ambient temperature, since MIDAS does not use this value during dose assessment calculations.
- 4. Notes were added to sections 5.6 and 5.7 to tell the user to use 1.0 for the default DT300, if the delta t is not available.
- 5. Editorial and typographical corrections were made during this revision of the procedure.
IMPLEMENTATION REQUIREMENTS Procedure Implementation Date:
5--Z-oc0a
IN APPROVED:
ý EPManaov
\\
APPROVED:
0 Vice President - Operations Date PSEG Internal Use Only 11ate
NC.EP-EP.ZZ-0309 (Q)
TABLE OF CONTENTS Section Title Page 1.0 P U R PO S E....................................................................................................
2 2.0 PREREQUISITES.............................................................................................
2 2.1 Prerequisites To Be Followed Prior To Implementing This Procedure..2 3.0 PRECAUTIONS AND LIMITATIONS..........................................................
2 3.1 Precaution and Limitations To Be Followed Prior To Implementing This Procedure...............................................................................
2 4.0 EQUIPMENT REQUIRED...........................................................................
3 5.0 PROCEDURE.............................................................................................
4 5.1 Sign-on Instructons For MIDAS........................................................
4 5.2 Performance of Dose Assessment When Plant Vent Effluent Monitors Increase by a Factor of Greater Than or Equal to >10.....
6 5.3 Preplanned Alternative Guidance.....................................................
8 5.4 Common Commands For MIDAS...............................................................
10 5.5 Perform the Following to Produce a SSCL Page 2 Using the Automatic Dose Assessment Mode...........................................................................
15 5.6 Perform the Following to Produce a SSCL Page 2 Using the Manual Dose Assessment Mode...........................................................................
17 5.7 Perform the Following to Produce a SSCL Page 2 Using Isotopic Dose Assessment Mode.......................................................................................
24 5.8 Perform the Appropriate Operational Instructions to Manipulate Map Screens and Obtain Printouts of Maps.....................................................
33 6.0 R E C O R D S.................................................................................................................
37
7.0 REFERENCES
37 7.1 References.................................................................................................
37 7.2 Cross References......................................................................................
37 ATTACHMENTS Operating Instructions For The VAX LA120 Terminal..................... 37 Operating Instructions For Salem SPDS Radiological Screens......... 41 FORMS Form - 1 SPDS RMS Log (Salem Only)..............................................................
44 Nuclear Common Rev. 03 Page 1 of 44
NC.EP-EP.ZZ-0309 (Q) 1.0 PURPOSE This procedure provides guidance and operating instructions concerning performing basic dose assessment using the dose assessment program MIDAS.
2.0 PREREQUISITES 2.1 Prerequisites to be Followed Prior to Implementing This Procedure Implement this procedure:
"* Upon the declaration of an Unusual Event or higher emergency classification.
"* At the request of the Operation Superintendent (OS).
"* At the request of the Emergency Duty Officer (EDO).
" At the request of the Radiation Protection Duty Supervisor (RPDS) or Shift Radiation Protection Technician (SRPT).
" lAW HC.RP-AR.SP-0001(Q), Radiation Monitoring System Gaseous Monitor Alarm Response.
3.0 PRECAUTIONS AND LIMITATIONS 3.1 Precautions and Limitations to be Followed Prior to Implementing this Procedure:
3.1.1 SectionslSteps in this procedure may be performed in the order deemed appropriate for the emergency situation.
Only SectionslSteps that are applicable to the specific MIDAS dose assessment mode of operation that is being performed need to be followed.
3.1.2 It is recommended that initials be used in the place keeping sign-offs, instead of checkmarks, if more than one person may implement this procedure.
Nuclear Common Page 2 of 44 Rev. 03
NC.EP-EP.ZZ-0309 (Q) 3.1.3 This procedure is limited to performance of basic dose assessment calculations (Automatic Mode, Manual Mode, and Isotopic Mode) 3.1.4 Personnel who implement this procedure shall be trained and qualified lAW the Emergency Plan.
4.0 EQUIPMENT REQUIRED Necessary equipment is provided in the Emergency Response Facilities.
Nuclear Common Page 3 of 44 Rev. 03
NC.EP-EP.ZZ-0309 (Q) 5.0 PROCEDURE NOTE
"* Dose Assessment should be performed using 10 or 15-minute average RMS and Meteorological data, unless circumstances in Section 5.2 are met.
"* Attachment 1, Operating Instructions for the VAX LA120 Terminal, should be referred to for directions on operating the VAX LA120.
"* Attachment 2, Operating Instructions for Salem SPDS Radiological Screens, should be referred to for directions concerning operating the SPDS radiological screens, including the RM and RML Screens.
5.1 Sign-on Instructions For MIDAS 5.1.1 DEPRESS the POWER button. (The Microsoft Windows NT Screen will appear with a Begin Logon box displayed. The command inside the box will read, Press Ctrl + Alt + Delete to logon).
5.1.2 DEPRESS the Ctrl, Alt, Delete keys simultaneously. (The Logon Information box will be displayed with lines to enter User name and Password).
5.1.3 INPUT midas into the User name line.
5.1.4 INPUT midas into the Password line and depress the RETURN key.
5.1.5 POSITION the cursor on the Midas Icon and click the mouse twice.
(The MIDAS unit selection screen will be displayed).
5.1.6 POSITION the mouse cursor + over the box of your selection (Hope Creek, Salem Unit 1, or Salem Unit 2) and click the mouse once. (Your selection will become highlighted).
5.1.7 POSITION the cursor over the CONFIRM box and click the mouse once. (The Function Selection screen will appear).
Nuclear Common Rev. 03 Page 4 of 44
NC.EP-EP.ZZ-0309 (Q) 5.1.8 SELECT the appropriate Section for type of dose assessment mode from list below:
" Refer to Section 5.2 to perform Dose Assessment When Plant Vent Effluent Monitors Increase By A Factor of > 10.
" Refer to Section 5.3 for guidance concerning Preplanned Alternate Methods to perform Dose Assessment.
Refer to Section 5.4 for Common MIDAS Commands:
"o Change Date andlor Time.
"o Exit MIDAS Utilizing CTRL, ALT, DELETE Keys.
"o Print a Screen, Report, Map, or an additional SSCL.
"* Refer to Section 5.5 to perform Dose Assessment in Automatic Mode.
"* Refer to Section 5.6 to perform Dose Assessment in Manual Mode.
" Refer to Section 5.7 to perform Dose Assessment in Isotopic Mode.
" Refer to Section 5.8 to perform Manipulate Maps Screens and Print Out a Map.
" Refer to Attachment I for Operating Instructions for the VAX LAI20 Terminal.
"* Refer to Attachment 2 for Operating Instructions for SALEM SPDS Radiological Screens.
Nuclear Common Rev. 03 Page 5 of 44
NC.EP-EP.ZZ-0309 (Q) 5.2 Performance of Dose Assessment When Plant Vent Effluent Monitors Increase by a Factor of Greater Than Or Equal to > 10:
NOTE Salem and Hope Creek Plant Vent Effluent Monitors are:
SALEM PLANT VENT EFFLUENT MONITORS
- Unitlor2R41A, B,C
- Unitlor2R45B, C HOPE CREEK PLANT VENT EFFLUENT MONITORS
- SPV - 9RX606, 9RX607, 9RX581
- NPV-9RX602, 9RX603, 9RX591
- FRVSV-9RX640, 9RX610, 9RX611
- H'V-9RX516, 9RX517 5.2.1 IF any Plant Vent Effluent Monitor(s) increase by a factor of 10 or more, THEN perform the following:
A.
PERFORM dose assessment calculations in the manual mode using instantaneous value(s) In Accordance With (lAW)
Section 5.6 of this procedure.
B.
WRITE on top of the Station Status Checklist Page 2 (SSCL), "RELEASE RATE CALCULATED FROM INSTANTANEOUS MONITOR VALUES."
C.
RECOMMEND radiological PARs using the SSCL, lAW SC.EP-EP.ZZ-0301(Q),
HC.EP-EP.ZZ-0301(Q), OR NC.EP EP.ZZ-0602(Q), as appropriate.
D.
ADVISE the appropriate person (OS, RAC, RSM) that, "The SSCL and radiological PAR (if any) was calculated from instantaneous Plant Vent data and may not reflect actual radiological conditions. An additional SSCL will be forth coming in approximately 20 minutes."
Nuclear Common Rev. 03 Page 6 of 44
NC.EP-EP.ZZ-0309 (Q)
E.
PERFORM another dose assessment in approximately 15 to 20 minutes using 10 or 15-minute average data.
F.
Provide the SSCL and radiological PAR, if applicable, to the appropriate person (OS, RAC, RSM).
Nuclear Common Rev. 03 Page 7 of 44
NC.EP-EP.ZZ-0309 (Q) 5.3 Preplanned Alternative Guidance NOTE SALEM UNITIl2 ONLY Contact the OS prior to performing dose assessment calculations for preplanned alternative, if the 1 R41 or 2R41 monitor(s) are out of service/inoperational and are needed to perform dose assessment calculations.
5.3.1 PERFORM the appropriate steps listed below, to calculate a SSCL, when the normal method to perform dose assessment at SALEM UNIT I andlor SALEM UNIT 2 is NOT possible:
A. IMPLEMENT Section 5.6, to perform dose assessment calculations using Main Steam Line (MSL) Teletector Readinqs.
All contact teletector readings on the MSLs should be obtained on the curve of the line prior to the MSIV.
(See the diagram below).
Teletector Rad Monitor Location MAIN STEAM LINES 12,14,22,24 ARE FOUND IN THE OUTSIDE PIPING PENETRATIONS.
MAIN STEAM LINES 11, 13, 21, 23 ARE ACCESSIBLE BY WAY OF THE CHILLER ROOMS AND ARE LOCATED IN THE INNER PIPE PENETRATIONS.
Nuclear Common Page 8 of 44 Rev. 03
NC.EP-EP.ZZ-0309 (Q)
B. IMPLEMENT Section 5.6, to perform dose assessment calculations based on the R45 monitor values.
C. PERFORM steps 1 and 2 for Salem Unit 1/2 to calculate a value using the R16 monitor that can be used by MIDAS to perform dose assessment calculations, if the 1/2 R41A monitor is not operational.
I DIVIDE the R16 value by 3.55E+07 to calculate a uCi/cc value. This calculated value will be used in MIDAS to perform a dose assessment calculation.
(cpm)
=
uCi/cc 3.55E+07 (cpm/uCi/cc) 2 INPUT the uCi/cc value into MIDAS under the R45 monitor header using Manual MIDAS Mode (Section 5.6).
5.3.2 IF ISOTOPIC DATA is available, THEN IMPLEMENT Section 5.7, to perform dose assessment calculations based on isotopic sample values for Hope Creek, Salem Unit 1, or Salem Unit 2.
Nuclear Common Rev. 03 Page 9 of 44
NC.EP-EP.ZZ-0309 (Q) 5.4 Common Commands For MIDAS 5.4.1 PERFORM the following steps to change the DATE andlor TIME for the PC based MIDAS dose assessment system for Hope Creek, Salem Unit 1, and Salem Unit 2:
A.
POWER UP the computer. (The Microsoft Windows NT Screen will appear with a Begin Logon box displayed.
The command inside the box will read:
Press Ctrl + Alt + Delete to logon).
B.
DEPRESS the Ctrl, Alt, Delete keys simultaneously.
(The Logon Information box will be displayed with blanks to enter User name and Password).
C.
INPUT admin into the User name blank.
D.
INPUT secret into the Password blank and depress the RETURN key. (The Main Windows screen will be displayed with several icons. The CAPTURE Eze97 screen will appear momentarily, while it loads and then be displayed in a box in the lower left hand corner next to the Start box).
E.
POSITION the cursor over the MY COMPUTER icon and double click the mouse. (The MY COMPUTER box will be displayed with different icons in the box).
F.
POSITION the cursor over the CONTROL PANEL icon and double click the mouse. (The DATE/TIME icon will be displayed with several other icons).
G.
Position the cursor over the DATE/TIME icon and double click the mouse. (The DATE/TIME PROPERTIES screen will be displayed with the current month, date, and time highlighted).
H.
IF the DATE/TIME Properties screen is not displayed, THEN POSITION the cursor over the DATE & TIME file and click the mouse once.
- 1.
POSITION the cursor on the DOWN ARROW adjacent to the month, and click the mouse once.
J.
PERFORM the following to change the MONTH:
POSITION the cursor over the appropriate month and click the mouse once.
Nuclear Common Page 10 of 44 Rev. 03
NC.EP-EP.ZZ-0309 (Q)
K.
PERFORM the following to change the YEAR:
POSITION the cursor on the UP or DOWN ARROW next to the CURRENT YEAR box and click the mouse until the appropriate year is displayed.
L.
PERFORM the following to change the CALENDAR DATE:
POSITION the cursor on the CALENDAR DATE you wish to change and click the mouse once.
M.
PERFORM the following to change the CURRENT HOUR:
POSITION the cursor to the left side of the CURRENT HOUR that is displayed in the time box, and click the mouse until the appropriate hour is displayed.
[EXAMPLE: For 12:15:30 it would look like 121:15:30.
(I is the cursor)].
N.
PERFORM the following to change the CURRENT MINUTE:
POSITION the cursor to the left side of the CURRENT MINUTE that is displayed in the time box, and click the mouse until the appropriate minute is displayed.
[EXAMPLE: For 12:15:30 it would look like 12:151:30.(l is the cursor)].
- 0.
PERFORM the following to change the CURRENT SECOND:
POSITION the cursor to the left side of the CURRENT SECOND that is displayed in the time box, and click the mouse until the appropriate minute is displayed.
[EXAMPLE: For 12:15:30 it would look like 12:15:301.
(I is the cursor)].
P.
PERFORM the following to change from PM to AM or AM to PM:
POSITION the cursor on the displayed AM/PM and click the mouse once. Use the UP or DOWN ARROW adjacent to the time box to change the AM/PM by clicking the mouse once.
Nuclear Common Rev. 03 Page 11 of 44
NC.EP-EP.ZZ-0309 (Q)
Q.
PERFORM the following to APPLY THE CHANGES, EXIT OUT OF THIS MODE, AND RUN MIDAS:
- 1. POSITION the cursor on the APPLY box and click the mouse once.
- 2. POSITION the cursor on the OK box and click the mouse once.
- 3. POSITION the cursor over the X located in the upper right hand corner of the CONTROL PANEL box and click the mouse once.
- 4. POSITION the cursor over the X located in the upper right hand corner of the MY COMPUTER box and click the mouse once.
- 5. POSITION the cursor on the START and click the mouse once. (The WINDOWS NT WORKSTATION box will be displayed).
- 6. POSITION the cursor on the SHUT DOWN box and click the mouse once. (The SHUT DOWN WINDOWS box will be displayed).
- 7. POSITION the cursor on the close ALL PROGRAMS and LOG ON AS A DIFFERENT USER circle and click the mouse once. (The circle will become filled in).
- 8. POSITION the cursor over the YES box and click the mouse once. (The computer will start to close all programs. The BEGIN LOGON box will appear).
- 9. DEPRESS the Ctrl, Alt, Delete keys simultaneously.
(The Logon Information box will be displayed with lines to enter User name and Password).
- 10.
INPUT midas into the User name line.
- 11.
INPUT midas into the Password line and depress the RETURNIENTER key.
- 12.
POSITION the cursor over the Midas icon and double click the mouse. (The MIDAS Program will start).
Nuclear Common Rev. 03 Page 12 of 44
NC.EP-EP.ZZ-0309 (Q) 5.4.2 PERFORM the following steps to EXIT MIDAS using CTRL, ALT, and DELETE keys for Hope Creek, Salem Unit 1, and Salem Unit 2:
A.
DEPRESS the CTRL, ALT, and Delete keys simultaneously. (The Windows NT Security box will be displayed).
B.
MOVE the cursor to the Shut Down box and click the mouse once. (The Shutdown Computer box will be displayed with the Shutdown circle filled in).
C.
MOVE cursor to the OK box and click the mouse once. (The MIDAS - FROZEN box will be displayed).
D.
MOVE the cursor to the End Task box and click the mouse once. The computer will begin to restart. (All data inputted and dose assessment calculations will be lost).
E.
POSITION the cursor over the RESET box and click the mouse once to reset data that is displayed in a data box.
NOTE
" The Station Status Checklist (SSCL) will printout automatically after the dose assessment calculations have finished.
" Step 5.4.3 provides instructions for using the SSCL Box to print an additional SSCL.
" Step 5.4.3 provides instructions for using the SSCL Box to print a SSCL to the screen, if the printer is malfunctioning. A blank SSCL page 2 can be found in ECG Attachment 8 or obtained from Communicator Number 2.
5.4.3 PERFORM the following to PRINT A SSCL.
A. POSITION the cursor to the SSCL Box located on the Reports Screen.
B. CLICK the mouse. The latest SSCL will be printed to the screen and the printer.
Nuclear Common Rev. 03 Page 13 of 44
NC.EP-EP.ZZ-0309 (Q) 5.4.4 PERFORM the following to PRINT A SCREEN, REPORT, OR MAP:
A. DEPRESS ALT + ENTER B. DEPRESS PRINT SCREEN keys.
C. DEPRESS the ALT + ENTER keys to EXIT the print option and to continue with normal MIDAS operation.
Nuclear Common Page 14 of 44 Rev. 03
NC.EP-EP.ZZ-0309 (Q) 5.5 PERFORM THE FOLLOWING TO PRODUCE A SSCL PAGE 2 USING THE AUTOMATIC DOSE ASSESSMENT MODE 5.5.1 POSITION the cursor over ACCIDENT DOSE CALCULATIONS (AC) box and click the mouse once. (Your selection will become highlighted).
5.5.2 POSITION the cursor over the CONFIRM box and click the mouse once. (It will become highlighted and the Accident Dose Calculations (AC) screen will appear).
5.5.3 POSITION the cursor over the Quick Dose Projection AUTO REAL TIME (Menu A) box and click the mouse once. (Your selection will become highlighted).
5.5.4 POSITION the cursor over the CONFIRM box and click the mouse once. MIDAS will start to perform dose assessment calculations.
(The calculating screen will appear. The SSCL will automatically printout and the 10-mile map will appear on the screen).
5.5.5 POSITION the cursor to the CONTINUE box on the bottom of the screen and click the mouse once. (The NEXT REPORT box will replace the CONTINUE box).
Nuclear Common NOTE
"* IF at any time while performing Automatic Data Acquisition, the following appears on the screen:
NO RESPONSE FROM DADIS - (HOPE CREEK/SALEM) TO DADIS DATA COLLECTION FROM DADIS WAS TERMINATED ENTER OPTION: [YE] TRY DATA COLLECTION AGAIN
[NO] PROCEED WITH MANUAL ENTRY Respond in the following manner:
Select YE. IF the above message appears again, Select NO and proceed with data entry lAW Section 5.6.
" Dose Assessment MIDAS in automatic mode will not function correctly unless all appropriate Plant Vent Effluent monitor(s) and the Meteorological data are operational. Section 5.6 of this procedure should be used, if the appropriate Plant Vent Monitoring data point(s) or the Meteorological data point(s) are NOT available.
Rev. 03 Page 15 of 44
NC.EP-EP.ZZ-0309 (Q) 5.5.6 POSITION the cursor over the NEXT REPORT box and click the mouse once. (The MORE REPORTS box will replace the NEXT REPORT box).
5.5.7 POSITION the cursor over the MORE REPORTS box and click the mouse once. (The More Reports Selection screen will appear).
NOTE
"* Step 5.5.8 provides instructions for utilizing the SSCL Box to print a SSCL to the screen, if the printer is malfunctioning.
"* Step 5.5.8 provides instructions for utilizing the SSCL Box to print an additional SSCL.
"* A blank SSCL page 2 can be found in ECG Attachment 8 or obtained from Communicator 2.
5.5.8 IF a SSCL needs be printed to the screen or an additional SSCL printed out, THEN:
A.
POSITION the cursor over the SSCL Box and click the mouse once.
B.
POSITION the cursor over the CONFIRM box and click the mouse once. (The SSCL will be printed to the screen, and if the printer is functioning, an additional SSCL will be printed out.
5.5.9 POSITION the cursor over the EXIT box and click the mouse once.
(The box will become highlighted).
5.5.10 CLICK the mouse again. (The Function Selection screen will appear).
5.5.11 IF another dose assessment calculation and SSCL is needed, THEN REPEAT steps 5.5.1 through 5.5.9.
5.5.12 IF you need to exit the MIDAS program, THEN:
A.
POSITION the cursor over the EXIT box and click the mouse twice. (The Unit Selection screen will appear).
B.
POSITION the cursor over the EXIT box, click the mouse twice.
Nuclear Common Page 16 of 44 Rev. 03
NC.EP-EP.ZZ-0309 (Q) 5.6 PERFORM THE FOLLOWING TO PRODUCE A SSCL PAGE 2 USING THE MANUAL DOSE ASSESSMENT MODE NOTE Manual Mode Dose Assessment, should be performed IF:
"* A Plant Vent Effluent monitor is not operational.
"* A surveillance of the Plant Vent Effluent monitor is ongoing.
"* Automatic radiological data acquisition is not operational.
"* Automatic meteorological data acquisition is not operational.
"* To input the total isotopic noble gas and iodine 131 value.
5.6.1 POSITION the cursor over the ACCIDENT DOSE CALCULATIONS (AC) box and click the mouse once. (Your selection will become highlighted).
5.6.2 POSITION the cursor over the CONFIRM box and click the mouse once. (Your selection will become highlighted and the Accident Dose Calculations (AC) screen will appear).
5.6.3 POSITION the cursor over MANUAL ENTRY ON SPREADSHEET (MENU C) and click the mouse once. Your selection will become highlighted.
5.6.4 POSITION the cursor over the CONFIRM box and click the mouse once. (The box will become highlighted and the Scenario Data Table Control screen will appear).
5.6.5 SELECT the appropriate box by referring to the below guidance, And, position the cursor in that box:
"* IF this is the first initial input or the first input after a radiological release > technical specifications, THEN SELECT START NEW SCENARIO box and click the mouse once. (The START NEW SCENARIO and WARNING CURRENT DATA WILL BE ERASED boxes will become highlighted).
IF this is updating dose assessment calculations, THEN SELECT CURRENT SCENARIO EDIT box and click the mouse once. (The CURRENT SCENARIO EDIT box will become highlighted).
Nuclear Common Page 17 of 44 Rev. 03
NC.EP-EP.ZZ-0309 (Q)
IF a previous dose assessment run has been calculated by MIDAS, and the user wishes to view the plume map from that previous run and NOT obtain a VALID SSCL, THEN SELECT CURRENT SCENARIO NO EDIT box and click the mouse once. (The CURRENT SCENARIO NO EDIT box will become highlighted).
NOTE 15-minute average Meteorological conditions should be inputted every 15 minutes. (MIDAS will treat the release as a puff release that lasted only 15 minutes, if appropriate 15 minute increments are not inputted).
5.6.6 POSITION the cursor over the CONFIRM box and click the mouse once. (The box will become highlighted and the Meteorological Spread Sheet screen will appear with the current time highlighted. A blue rectangle will be displayed under the SPD33P (MPH) column).
5.6.7 MOVE the blue rectangle down the SPD33 (MPH) column until it is next to the highlighted time using the down arrow key.
5.6.8 INPUT appropriate data for the 33 foot elevation wind speed.
5.6.9 MOVE the blue rectangle over to the SPD300 (MPH) column using the right arrow key.
5.6.10 INPUT appropriate data for the 300 foot elevation wind speed.
5.6.11 MOVE the blue rectangle over to the DIR33P (DEG) using the right right arrow key.
Nuclear Common NOTE The 300 foot wind speed should be used for the 33 foot wind speed, if the 33 foot wind speed is not available.
NOTE The 33 foot wind speed should be used for the 300 foot wind speed, if the 300 foot wind speed is not available.
Rev. 03 Page 18 of 44
NC.EP-EP.ZZ-0309 (Q) 5.6.12 INPUT appropriate data for the 33 foot elevation wind direction.
NOTE The Default Value of one (1.0) should be used for DT300, if the delta t data is not available. This will produce an "E" stability class.
5.6.13 MOVE the blue rectangle over to the DT300 (DEG C) using the right arrow key.
5.6.14 INPUT appropriate data for the 300 - 33 foot delta temperature.
NOTE MIDAS does not use the value for the ambient temperature. Twenty (20) degress should be used for ambient temperature.
5.6.15 MOVE the blue rectangle over to the TEM33 (DEG C) using the right arrow key to input the ambient temperature.
5.6.16 INPUT 20 for the ambient temperature.
5.6.17 MOVE the blue rectangle over to the RAINFL (IN) using the right arrow key.
5.6.18 INPUT appropriate data for the 15-minute average rainfall.
(The values 0.08 for Heavy, 0.02 for Moderate, and 0.01 for Light, rainfall may be used if actual rainfall in inches is not known).
5.6.19 DEPRESS the ENTER key.
5.6.20 IF all inputs are correct, THEN Depress the X key. (The Gaseous Vent and Flow screen will appear with the current time highlighted).
5.6.21 IF all inputs are NOT correct, THEN use the arrow keys to go back to the appropriate column(s) and input correct data and depress the X key. (The Gaseous Vent and Flow screen will appear with the current time highlighted).
5.6.22 Refer to the NOTE below for guidance concerning which monitor(s) and value(s) to select and input into MIDAS.
Nuclear Common Page 19 of 44 Rev. 03
NC.EP-EP.ZZ-0309 (Q)
NOTE FOR HOPE CREEK AND SALEM UNIT 1 & 2 10 or 15 Minute Average Plant vent (PV) monitor data and PV flow rates should be inputted every 15 Minutes.
Monitoring Points with - DI next to them (i.e. FRVS - DI, R45 - DI) should be used to input the total I -131 isotopic value in uCi/cc, when available from a plant vent sample.
FOR HOPE CREEK ONLY The following monitoring points are available for use in manual dose assessment mode:
(NPV-P, NPV-I, NPV-NG, NPV-DI), (SPV-P, SPV-I, SPV-NG, SPV-DI), (FRVS-NG, FRVS-DI), (HTV-NG, HTV-DI)
FOR SALEM UNT 1 & 2 ONLY Follow the below guidance to help in making the correct decision of which R41 monitor value to use. Only ONE should be used in MIDAS for performing dose assessment.
"o R41A should be used if values are between IE-08 uCilcc to 9.99E-02 uCilcc.
"o R41B should be used if values are> IE-01 uCilcc to 9.99E+01 uCilcc.
"o R41C should be used if values are> 1E+02 uCilcc to IE+05 uCilcc.
0 The R45 monitors are to be used ONLY if the R41 B or R41 C monitor values are not available.
Follow the below guidance in making the correct decision of which R45 monitor value to use. Only ONE should be used in MIDAS for performing dose assessment.
"o R45B should be used if values are> IE-03 uCilcc to IE+01 uCi/cc.
"o R45C should be used if values are> IE+01 uCi/cc to IE+05 uCilcc.
R46: Dose assessment may be performed using the R46 monitor value during a primary to secondary leak or SGTR and entered in the R46MSL column in MIDAS.
Using Contact TELETECTOR VALUES From The MAIN STEAM LINES In MIDAS.
"o Refer to section 5.2 concerning where contact readings on the Main Steam Lines should be taken.
"o The Teletector value obtained from contact reading on the MSL MUST be multiplied by the Correction Factor of 9.33E-05 prior to being used in MIDAS.
"o The value should be entered in the R46MSL column.
"o The flow rate in lbs/hr may be obtained from the Control Room. (The value 4.50E+05 lbs/hr should be used as the default flow rate, if the actual flow rate is not known).
o R44: The R44 Monitor values should be used for "WHAT IF" type Calculations or if the Containment has been breached and an unmonitored release is progress o The flow rate range for the R44's is 1 to 1000 cfm, with the 1000 being the worse case (most conservative) scenario.
Nuclear Common Page 20 of 44 Rev. 03
NC.EP-EP.ZZ-0309 (Q) 5.6.23 MOVE the blue rectangle over to the right until the monitor of interest is highlighted using right arrow key.
NOTE Hope Creek's Hardened Torus Vent should be inputted in uCilsecond. NO Plant Vent Flow Rate should be inputted. All other Plant Vent Effluent data for Hope Creek and Salem Unit I & 2 should be inputted in uCilcc and include Plant Vent Flow Rates for each monitor that was inputted.
5.6.24 INPUT appropriate 10 or 15 minute average radiological data, or Instantaneous data, if the criteria listed in Section 5.2 are met.
5.6.25 MOVE the blue rectangle over to the right one position to flow rate for the monitor selected.
5.6.26 INPUT appropriate flow rate in cfm.
5.6.27 DEPRESS the ENTER key.
5.6.28 IF all inputs are correct, THEN DEPRESS the X key 5.6.29 IF an input is incorrect, THEN correct it and DEPRESS the X key.
(The DBA Accident Type Selection screen will appear with the UNKNOWN MIX box highlighted).
NOTE Unless directed by the RAC or RSM, UNKNOWN MIX should be used.
5.6.30 POSITION the cursor over the CONFIRM box and click the mouse once. (The WARNING - SOURCE IS ZERO FOR SELECTED POINT(S), with the points of that the user didn't input data for will appear).
5.6.31 POSITION the cursor over the CONTINUE box and click the mouse once. (The box will become highlighted and the Release Timing Selection screen will appear with the Trip Date, Release Start Same As Trip Date, and Duration (Minutes) boxes will become highlighted).
Nuclear Common Page 21 of 44 Rev. 03
NC.EP-EP.ZZ-0309 (Q) 5.6.32 INPUT the duration of a release in minutes by performing the following:
A.
POSITION the cursor over the REMAINING DURATION (MIN) box and CLICK the mouse once. (A pop-up screen will appear in the upper right hand corner of the screen).
B.
POSITION the cursor over the appropriate number(s) you wish to enter (use 240 minutes for a four hour default release, if the duration of a release is not known) and CLICK the mouse once. (The number you chose will be displayed in the top portion of the pop-up screen).
C.
POSITION the cursor over the EN box and CLICK the mouse once. (The value selected will now appear in the highlighted REMAINING DURATION (MINUTES) box).
D.
IF the information was inputted incorrectly, THEN position the cursor over the CL box and CLICK the mouse once to clear the entire input that is displayed in the top portion of pop-up screen and reenter.
E.
POSITION the cursor over the CONFIRM box and click the mouse once. (MIDAS will start to perform calculations. The calculating screen will appear. The SSCL will automatically printout and the 10-mile TEDE 4-DAY map will appear on the screen).
5.6.33 MOVE the cursor to the CONTINUE box on the bottom of the screen and click the mouse once. (The NEXT REPORT box will replace the CONTINUE box).
5.6.34 POSITION the cursor over the NEXT REPORT box and click the mouse once. (The MORE REPORTS box will replace the NEXT REPORT box).
5.6.35 POSITION the cursor over the MORE REPORTS box and click the mouse once. (The More Reports Selection screen will appear).
NOTE
"* Step 5.6.36 provides instructions for using the SSCL Box to print a SSCL to the screen if the printer is malfunctioning.
"* Step 5.6.36 provides instructions for using the SSCL Box to print an additional SSCL.
"* A blank SSCL page 2 can be found in ECG Attachment 8 or obtained from Communicator 2.
Page 22 of 44 Rev. 03 Nuclear Common
NC.EP-EP.ZZ-0309 (Q) 5.6.36 IF a SSCL needs be printed to the screen or an additional SSCL is needed to be printed, THEN:
A. POSITION the cursor over the SSCL Box and click the mouse once.
B. POSITION the cursor over the CONFIRM box and click the mouse once. (The SSCL will be printed to the screen, and if the printer is functioning, an additional SSCL will be printed out.
5.6.37 POSITION the cursor over the EXIT box and click the mouse once.
(The box will become highlighted).
5.6.38 CLICK the mouse again. (The Function Selection screen will appear).
5.6.39 IF another dose assessment calculation and SSCL is needed, THEN REPEAT steps 5.6.1 through 5.6.38.
5.6.40 IF you need to exit the MIDAS program, THEN:
A.
POSITION the cursor over the EXIT box and click the mouse twice. (The Unit Selection screen will appear).
B.
POSITION the cursor over the EXIT box, click the mouse twice.
Nuclear Common Page 23 of 44 Rev. 03
NC.EP-EP.ZZ-0309 (Q) 5.7 PERFORM THE FOLLOWING TO PRODUCE A SSCL PAGE 2 USING THE ISOTOPIC DOSE ASSESSMENT MODE 5.7.1 POSITION the cursor over the ACCIDENT DOSE CALCULATIONS (AC) box and CLICK the mouse once. (Your selection will become highlighted).
5.7.2 POSITION the cursor over the CONFIRM box and CLICK the mouse once. (Your selection will become highlighted and the Accident Dose Calculations (AC) screen will appear).
5.7.3 POSITION the cursor over ADVANCED CALCS ALL SCREENS (MENU X) and CLICK the mouse once. Your selection will become highlighted.
5.7.4 POSITION the cursor over the CONFIRM box and CLICK the mouse once. (The box will become highlighted. MIDAS will attempt to collect automatic data. The Miscellaneous Parameters screen will then appear).
5.7.5 PERFORM the following to highlight appropriate selections:
A.
POSITION the cursor over the RESET box and CLICK the mouse. Boxes will no longer be highlighted.
B.
POSITION the cursor over the MANUAL box and CLICK the mouse once.
Nuclear Common NOTE Dose Assessment should be performed in Isotopic Mode, if Dose Assessment calculations are being performed using Isotopic Plant Vent Grab Sample data.
IF at any time while performing Automatic Data Acquisition, the following appears on the screen:
NO RESPONSE FROM DADIS - HOPE CREEK TO DADIS DATA COLLECTION FROM DADIS WAS TERMINATED ENTER OPTION: [YE] TRY DATA COLLECTION AGAIN
[NO] PROCEED WITH MANUAL ENTRY Respond in the following manner: Choose NO and proceed with following the steps listed in this section (5.7) of this procedure.
Page 24 of 44 Rev. 03
NC.EP-EP.ZZ-0309 (Q)
C.
POSITION the cursor over the appropriate RELEASE POINT(S) and CLICK the mouse once. The box will become highlighted.
D.
POSITION the cursor over the FLOW EX VEL (CFM) box for the release point chosen and CLICK the mouse once.
(A pop-up screen will appear).
E.
INPUT the exit velocity flow rate using the pop-up screen by positioning the cursor over the correct value(s) and CLICKING the mouse once.
Exit Velocity For HOPE CREEK: ZERO (0) for all REL PTs.
Exit Velocity For SALEM: ZERO (0) for REL PTs. 1 and 4 Exit Velocity For SALEM: (95) for REL PT 2 F.
INPUT the exit velocity flow rate using the pop-up screen by positioning the cursor over the correct value(s), selected from above, and CLICKING the mouse once.
G.
POSITION the cursor over the EN box when the appropriate values are inputted and CLICK the mouse once. (The box will become highlighted with the flow rate inside the box).
H.
POSITION the cursor over the MAX DIST DOWNWIND (MILES) box and CLICK the mouse once. A pop-up screen will appear.
I.
INPUT 10 using the pop-up screen.
J.
POSITION the cursor over the EN box and CLICK the mouse once. (The box will become highlighted with 10 appearing inside the box).
5.7.6 POSITION the cursor over the AUTO SCENARIO INTEGRATION box and CLICK the mouse once. (The box will become highlighted).
5.7.7 POSITION the cursor over the CONFIRM box and CLICK the mouse once. (The box will become highlighted and Run Mode and Integration screen will appear).
5.7.8 POSITION the cursor over the PROJECTED (FORECAST)
DOSE box and CLICK the mouse once.
Nuclear Common Page 25 of 44 Rev. 03
NC.EP-EP.ZZ-0309 (Q) 5.7.9 POSITION the cursor over the START DATE INTEG.
CURRENT Box and CLICK the mouse once.
5.7.10 IF the PROJ. TIMES (HRS) box doesn't have.25, 1, 4, 24 displayed and highlighted inside of the box, THEN POSITION the cursor over the PROJ. TIMES (HRS) box and CLICK the mouse once. (A pop-up screen will appear in the upper right of the screen).
5.7.11 INPUT.25,1, 4, 24 using the pop-up screen.
5.7.12 POSITION the cursor over the EN box when the appropriate values are inputted and CLICK the mouse once. (The box will become highlighted with the values displayed inside the box).
5.7.13 POSITION the cursor over the CONFIRM box and CLICK the mouse once. (The box will become highlighted and the Release Option Selection screen will appear).
5.7.14 POSITION the cursor over the MANUAL ENTRY OF ISOTOPE CONCENTRATION box and CLICK the mouse once. (The box will become highlighted).
5.7.15 POSITION the cursor over the CONFIRM box and CLICK the mouse once. (The Isotope Concentrations screen for the release point selected will appear).
5.7.16 POSITION the cursor over the RESET box and CLICK the mouse.
5.7.17 POSITION the cursor over the appropriate isotope box(es) and CLICK the mouse once. [The box(es) will become highlighted and a pop up screen will appear in the right corner of the screen].
5.7.18 POSITION the cursor over the appropriate number(s) you wish to enter and CLICK the mouse once. (The number you chose will be displayed in the top portion of the pop up screen).
5.7.19 IF the value(s) displayed is correct, THEN PLACE the cursor over the EN box and CLICK the mouse once. (The value selected will be displayed in the box).
5.7.20 IF the value is incorrect, THEN position the cursor over the CL box and CLICK the mouse once. (This will clear the input that is displayed in the top portion of the pop-up screen and allow you to reenter the value(s).
Nuclear Common Page 26 of 44 Rev. 03
NC.EP-EP.ZZ-0309 (Q) 5.7.21 POSITION the cursor over the SAMPLE STREAM FLOW RATE (CFM) box to input the plant vent flow rate and CLICK the mouse once. (The box will become highlighted and a pop-up screen will appear in the right corner of the screen).
5.7.22 Input the appropriate value(s) using the pop-up screen.
5.7.23 IF the value(s) displayed is correct, THEN PLACE the cursor over the EN box and CLICK the mouse once. (The value selected will be displayed in the box).
5.7.24 IF the value(s) is incorrect, THEN position the cursor over the CL box and CLICK the mouse once. (This will clear the input that is displayed in the top portion of the pop-up screen and allow you to reenter the value(s).
5.7.25 POSITION the cursor over the CONFIRM box and CLICK the mouse once. (The Release Timing Selection screen will appear).
5.7.26 POSITION the cursor over the RELEASE CURRENT TIME box and CLICK the mouse once.
5.7.27 POSITION the cursor over the DURATION (MINUTES) box and CLICK the box once. A pop-up screen will appear in the upper right corner of the screen.
5.7.28 INPUT the duration of the release in minutes (240 minutes if the release duration is unknown) using the pop-up screen.
"* IF the value(s) displayed is correct, THEN PLACE the cursor over the EN box and CLICK the mouse once. (The value selected will be displayed in the box).
IF the value is incorrect, THEN position the cursor over the CL box and CLICK the mouse once. (This will clear the input that is displayed in the top portion of the pop-up screen and allow you to reenter the value(s).
5.7.29 CLICK the mouse once. (The DURATION box will become highlighted with the value displayed in the box).
5.7.30 POSITION the cursor over the CONFIRM box and click the mouse once. (The Weather Selection screen will appear).
Nuclear Common Page 27 of 44 Rev. 03
NC.EP-EP.ZZ-0309 (Q) 5.7.31 PERFORM the following steps to input meteorological data:
NOTE
"* The user will NOT be prompted for the SPD33P (MPH) if the release is an elevated release.
"* The 300 foot wind speed should be used for the 33 foot wind speed, if the 33 foot wind speed is not available.
A.
POSITION the cursor over the DIR33P (DEG) box and CLICK the mouse once to input the 33 foot elevation from wind direction.
B.
POSITION the cursor over the appropriate number(s) you wish to enter and CLICK the mouse once. (The number you chose will be displayed in the top portion of the pop-up screen).
C.
MOVE the cursor over the EN box and CLICK the mouse once. [The value chosen will be displayed in specific weather parameter box that is being inputted (i.e. DIR33P DEG)].
D.
POSITION the cursor over the SPD33P (MPH) box and CLICK the mouse once to input the 33 foot elevation wind speed.
E.
POSITION the cursor over the appropriate number(s) you wish to enter and CLICK the mouse once. (The number you chose will be displayed in the top portion of the pop-up screen).
F.
MOVE the cursor over the EN box and CLICK the mouse once. [The value chosen will be displayed in specific weather parameter box that is being inputted (i.e. SPD33P MPH)].
Nuclear Common NOTE
- The user will NOT be prompted for the SPD300 (MPH) if the release is a ground release.
- The 33 foot wind speed should be used for the 300 foot wind speed, if the 300 foot wind speed is not available.
Rev. 03 Page 28 of 44
NC.EP-EP.ZZ-0309 (Q)
G.
POSITION the cursor over the SPD300 (MPH) box and CLICK the mouse once to input the 300 foot elevation wind speed.
H.
POSITION the cursor over the appropriate number(s) you wish to enter and CLICK the mouse once. (The number you chose will be displayed in the top portion of the pop-up screen).
I.
MOVE the cursor over the EN box and CLICK the mouse once. (The value chosen will be displayed in specific weather parameter box).
NOTE The Default Value of one (1.0) should be used for DT300, if the delta t data is not available. This will produce an "E" stability class.
J.
POSITION the cursor over the DT300 (DEG.C) box and CLICK the mouse once to input the 300 - 33 foot delta temperature. (The box will become highlighted).
K.
POSITION the cursor over the appropriate number(s) you wish to enter and CLICK the mouse once. (The number you chose will be displayed in the top portion of the pop-up screen).
L.
MOVE the cursor over the EN box and CLICK the mouse once. (The value chosen will be displayed in specific weather parameter box).
NOTE MIDAS does not use the value used for the ambient temperature. Twenty (20) degrees should be used.
M.
POSITION the cursor over the TEMP33 (DEG.C) box and CLICK the mouse once to input the ambient temperature.
(The box will become highlighted).
N.
INPUT the value 20 and CLICK the mouse once. (The number 20 will be displayed in the top portion of the pop-up screen).
Nuclear Common Page 29 of 44 Rev. 03
NC.EP-EP.ZZ-0309 (Q)
- 0.
MOVE the cursor over the EN box and CLICK the mouse once. (The value chosen will be displayed in specific weather parameter box).
P.
POSITION the cursor over the RAIN (INCHES) box and CLICK the mouse once to input the 15 minute average precipitation. (The box will become highlighted).
NOTE The following values may be inputted if actual rainfall data is not known:
0.08 = (Heavy Rainfall) 0.02 = (Moderate Rainfall) 0.01 = (Light Rainfall)
- The number Zero "0", if it is not raining.
Q.
POSITION the cursor over the appropriate number(s) you wish to enter and CLICK the mouse once. (The number you chose will be displayed in the top portion of the pop-up screen).
R.
MOVE the cursor over the EN box and CLICK the mouse once. (The value chosen will be displayed in specific weather parameter box).
NOTE The three boxes labeled PCT CLOUD COVER REQUIRES SPEED, USE LAST MET DATE and USE DEFAULT MET should NOT be used.
S.
POSITION the cursor over CONFIRM box and CLICK the mouse once. (The Release Point Data screen will appear).
5.7.32 POSITION the cursor over the CONTINUE box and CLICK the mouse once. (The box will become highlighted and Summary of Meteorological Data screen will appear).
Nuclear Common Rev. 03 Page 30 of 44
NC.EP-EP.ZZ-0309 (Q) 5.7.33 POSITION the cursor over CONTINUE box and CLICK the mouse once. (The calculating screen will appear, while PC MIDAS performs dose assessment calculations. The SSCL will automatically printout and the 10 mile TEDE 4-DAY map will appear on the screen after the calculations are finished.)
5.7.34 POSITION the cursor to the CONTINUE box on the bottom of the screen and CLICK the mouse once. (The NEXT REPORT box will replace the CONTINUE box).
5.7.35 POSITION the cursor over the NEXT REPORT box and CLICK the mouse once. (The MORE REPORTS box will replace the NEXT REPORT box).
5.7.36 POSITION the cursor over the MORE REPORTS box and CLICK the mouse once. (The More Reports Selection screen will appear).
NOTE
"* Step 5.7.37 provides instructions for utilizing the SSCL Box to print a SSCL to the screen, if the printer is malfunctioning.
"* Step 5.7.37 provides instructions for utilizing the SSCL Box to print an additional SSCL.
"* A blank SSCL page 2 can be found in ECG Attachment 8 or obtained from Communicator 2.
5.7.37 IF a SSCL needs be printed to the screen or an additional SSCL printed out, THEN:
A.
POSITION the cursor over the SSCL Box and CLICK the mouse once.
B.
POSITION the cursor over the CONFIRM box and CLICK the mouse once. (The SSCL will be printed to the screen, and if the printer is functioning, an additional SSCL will be printed out).
5.7.38 POSITION the cursor over the EXIT box and CLICK the mouse once. (The EXIT box will become highlighted).
5.7.39 CLICK the mouse again. (The Function Selection screen will appear).
Nuclear Common Page 31 of 44 Rev. 03
NC.EP-EP.ZZ-0309 (Q) 5.7.40 IF another dose assessment calculation and SSCL is needed, THEN REPEAT steps 5.7.1 through 5.7.38.
5.7.41 IF you need to exit the MIDAS program, THEN:
A.
POSITION the cursor over the EXIT box and click the mouse twice. (The Unit Selection screen will appear).
B.
POSITION the cursor over the EXIT box, click the mouse twice.
Nuclear Common Rev. 03 Page 32 of 44
NC.EP-EP.ZZ-0309 (Q) 5.8 PERFORM THE APPROPRIATE OPERATIONAL INSTRUCTIONS TO MANIPULATE MAP SCREENS AND PRINTOUT MAPS NOTE This section (5.8) should be used to access different map functions and options.
5.8.1 PERFORM the following to PRINT a SCREEN, REPORT, or MAP:
A. DEPRESS ALT + ENTER, PRINT SCREEN keys.
B. DEPRESS depress the ALT + ENTER keys to exit the print option and to continue with normal MIDAS operation.
5.8.2 PERFORM the Following Steps to Display A POI Dose Rate:
A.
POSITION the cursor over the POI box located at the bottom of the map screen and CLICK the mouse once.
(The Operational Choices menu located at the bottom of the screen next to the POI box is replaced with the CURSOR HERE TO EXIT box).
B.
POSITION the cursor + to the POI on the map you wish to know the dose rates at and CLICK the mouse once. (The dose rate of the POI will appear).
C.
POSITION the cursor to the CURSOR HERE TO EXIT box and CLICK the cursor once to return to the other map command options.
5.8.3 PERFORM the following steps to draw map features onto a map:
A.
POSITION the cursor over the MAP FEATURES box and CLICK the mouse once. (A Pop-up box will appear at the right side of the screen).
B.
POSITION the cursor over the option(s) selected (WIND SPIDER, COUNTY BOUNDARIES, ERPAS, andlor TEXT) to be drawn on the map and CLICK the mouse once.
(The options selected will become highlighted).
C.
POSITION the cursor over the CONFIRM box and CLICK the mouse once. (The Confirm box will become highlighted and the map will be redrawn with the option(s) selected illustrated on it).
Rev. 03 Nuclear Common Page 33 of 44
NC.EP-EP.ZZ-0309 (Q) 5.8.4 PERFORM the following to add another or remove the Map Feature Selected Perform.
A.
POSITION the cursor over the MAP FEATURES box and CLICK the mouse once. (A Pop-up box will appear at the right side of the screen).
B.
POSITION the cursor over the option(s) selected (WIND SPIDER, COUNTY BOUNDARIES, ERPAS, andlor TEXT) to be added to or removed from the map and CLICK the mouse once. (Any additional options selected will be highlighted, while options to be removed from the map will go from being highlighted to not being highlighted).
C.
POSITION the cursor over the CONFIRM box and click the mouse once. (The Confirm box will become highlighted and the map will be redrawn with the option(s) selected either deleted or illustrated on it).
5.8.5 PERFORM the following to select an area on a map to blowup:
A.
POSITION the cursor over the SELECT AREA box and CLICK the mouse once. (The Operational Choices menu located on the bottom of the screen will disappear).
B.
POSITION the cursor to one edge of the area you wish to enlarge on the screen and CLICK the mouse once. (A black dot will appear where the cross hairs of the cursor was).
C.
POSITION the cursor to other edge of the area you wish to enlarge on the screen and CLICK the mouse once.
(A black dot will appear where the cross hairs of the cursor was and the area you selected will appear on the screen enlarged with the Operational Choices menu reappearing on the bottom of the screen. This can be done as many times as the user wishes).
D.
POSITION the cursor over the RESTORE box and CLICK the mouse once to return the map to its original size.
5.8.6 PERFORM the following steps to project the plume Into the future using the current meteorological and radiological conditions:
Nuclear Common Rev. 03 Page 34 of 44
NC.EP-EP.ZZ-0309 (Q)
A.
POSITION the cursor over the CONTINUE box and CLICK the mouse once. (The Operational Choices menu located at the bottom of the screen will disappear being replaced by the PROJ. TIME 0.25 (HOURS), CONFIRM and NEXT REPORT boxes).
B.
POSITION the cursor over the PROJ. TIME 4.00 (HOURS) box and:
- 1.
CLICK the mouse to change the projection time to 24.00 hours0 days <br />0 hours <br />0 weeks <br />0 months <br />.
- 2.
CLICK the mouse again to change the projection time to 0.25 hours2.893519e-4 days <br />0.00694 hours <br />4.133598e-5 weeks <br />9.5125e-6 months <br />.
- 3.
CLICK the mouse again to change the projection time to 1.00 hours0 days <br />0 hours <br />0 weeks <br />0 months <br />.
- 4.
CLICK the mouse again to change the projection time back to 4.00 hours0 days <br />0 hours <br />0 weeks <br />0 months <br />.
C.
POSITION the cursor over the CONFIRM box when the appropriate projection time has been selected and CLICK the mouse once. (The map will be redrawn showing the plume and radiological conditions projected into the future by the time increment chosen by the user. The map Operational Choices menu will also reappear at the bottom of the screen).
5.8.7 PERFORM the following steps to change the plume back to 4.00 hour0 days <br />0 hours <br />0 weeks <br />0 months <br /> projection time:
A.
POSITION the cursor over the CONTINUE box and CLICK the mouse once. (The Operational Choices menu located at the bottom of the screen will disappear being replaced by the PROJ. TIME with 1.00, 4.00, or 24.00 HOURS, CONFIRM and NEXT REPORT boxes).
B.
POSITION the cursor over the PROJ. TIME box and CLICK the mouse until 4.00 (HOURS) appears.
C.
POSITION the cursor over the CONFIRM box and CLICK the mouse once. (The map will be redrawn showing the plume and radiological conditions returned to their original state. The map Operational Choices menu will also reappear at the bottom of the screen).
Nuclear Common Page 35 of 44 Rev. 03
NC.EP-EP.ZZ-0309 (Q) 5.8.8 PERFORM the following steps to change the distance of a map displayed:
NOTE A map MUST be already displayed prior to varying the map's distance.
A.
POSITION the cursor over the CONTINUE box and CLICK the mouse once. (The CONTINUE box will be replaced by the NEXT REPORT box).
B.
POSITION the mouse over the NEXT REPORT box and CLICK the mouse once. (The NEXT REPORT box will be replaced by the MORE REPORTS box).
C.
POSITION the cursor over the MORE REPORTS box and CLICK the mouse once. (The More Reports Selection Screen will appear).
D.
POSITION the mouse over the Report Plot the user would like to select and CLICK the mouse once. (The selection will become highlighted. Maps can be only drawn using REPORT PLOT choices).
E.
POSITION the cursor over the CONFIRM box and CLICK the mouse once. The box will become highlighted and the Report Parameter Selection screen will appear with the user's selection enclosed in a box in the middle of the screen.
F.
POSITION the cursor over the CONFIRM box and CLICK the mouse once. (The Map Scale Selection screen will appear with the current map distance appearing highlighted in a box in the upper left-hand corner of the screen).
G.
POSITION the cursor over MAP SCALE (MILES) box and CLICK the mouse once. (A pop-up screen will appear in the upper right hand corner).
H.
POSITION the cursor over the appropriate number(s) you wish to enter and CLICK the mouse once. (The number(s) you chose will be displayed at the top of the pop-up screen).
Nuclear Common Rev. 03 Page 36 of 44
NC.EP-EP.ZZ-0309 (Q)
- 1.
POSITION the cursor over the EN box in the pop-up screen and CLICK the mouse once.
J.
IF the number(s) displayed in the top of the pop up screen is incorrect, THEN position the cursor over the CL box and CLICK the mouse once. (This will clear the entire input that is displayed in the top of the pop up screen).
K.
POSITION the cursor over CONFIRM box and CLICK the mouse once. (The CONFIRM box will become highlighted and the map will be drawn to the scale selected).
6.0 RECORDS Return completed procedure and any information or data thought to be pertinent by the dose assessor, to the EP Manager.
7.0 REFERENCES
7.1 References 7.1.1 EPA 400, Manual of Protective Action Guides And Protective Actions For Nuclear Incidents 7.1.2 MIDAS Documentation Volumes 1-5 7.1.3 Nuclear Business Unit Emergency Plan 7.2 Cross References 7.2.1 NC.EP-EP.ZZ-0310(Q), Radiation Protection Supervisor Offsite and Field Monitoring Team Response 7.2.2 HC.EP-EP.ZZ-0301(Q), Shift Radiation Protection Response 7.2.3 SC.EP-EP.ZZ-0301(Q), Shift Radiation Protection Response Nuclear Common Rev. 03 Page 37 of 44
NC.EP-EP.ZZ-0309 (Q)
ATTACHMENT I Page I of 3 OPERATING INSTRUCTIONS FOR THE VAX LA120 TERMINAL 1.0 METEOROLOGICAL DATA 1.1 Perform The Following to Obtain Current 15 Minute Average Meteorological Data:
1.1.1 DEPRESS the RETURN key. (USERNAME should be displayed).
1.1.2 TYPE MET and depress the RETURN key.
NOTE The most current meteorological data should be printed out followed by the Main Meteorological Menu. If no other keys are depressed, the current 15 minute average data will be printed out every 15 minutes 1.1.3 ENTER Option I (Display Current Meteorological Data) and Depress the RETURN key to receive the current 15 meteorological data print out.
1.2 Perform The Following Steps to Obtain Archived Meteorological Data:
1.2.1 DEPRESS the RETURN key. (USERNAME should be displayed).
1.2.2 TYPE MET and depress the RETURN key. (The most current meteorological data should be printed out followed by the Main Meteorological Menu).
1.2.3 ENTER Option 2 (Display Meteorological Data From Data Base) and depress the RETURN key. (Current system Date and Time will be displayed).
1.2.4 IF this is the data you want, THEN depress the RETURN key. (Your option will be printed out).
1.2.5 IF you want data from another date and time, THEN go to Step 1.2.6.
Nuclear Common Page 38 of 44 Rev. 03
NC.EP-EP.ZZ-0309 (Q)
ATTACHMENT I Page 2 of 3 1.2.6 ENTER START DATE and TIME as shown below and depress the RETURN key. (For December 27, 1989 at 0130 enter 27-DEC-1 989 "depress the space bar once" and enter 01:30).
ENTER "Y" if the information is correct.
ENTER "N" if the information is not correct and reenter data as shown in Step 1.2.6.
1.2.7 ENTER the END DATE and TIME as shown below and depress the RETURN key. (For December 28, 1989 at 0230 enter 28-DEC-1 989 "depress the space bar once" and enter 02:30).
ENTER "Y" if the information is CORRECT.
o ENTER "N" if the information is NOT CORRECT and reenter data as shown in Step 1.2.7.
2.0 RMS AND MET DATA (FOR HOPE CREEK ONLY) 2.1 Perform The Following Steps to Obtain Current Instantaneous RMS and MET Data:
2.1.1 DEPRESS the RETURN key. (USERNAME should be displayed).
2.1.2 TYPE EOF and depress the RETURN key. (A prompt should be displayed asking for PASSWORD).
2.1.3 TYPE the letters EOFUSER and depress the RETURN key.
(The EOF Plant Menu should be displayed.)
2.1.4 SELECT Option 1 for Hope Creek.
2.1.5 DEPRESS the RETURN key. (The EOF Report Options Menu will be displayed).
2.1.6 ENTER Option I (Current RMS Status) and depress the RETURN key. (The most current instantaneous RMS and 15 minute MET data will be printed out.)
Nuclear Common Rev. 03 Page 39 of 44
NC.EP-EP.ZZ-0309 (Q)
ATTACHMENT I Page 3 of 3 2.2 Perform The Following Steps to Obtain 15 Minute Average RMS Data:
2.2.1 DEPRESS the RETURN key. (USERNAME should be displayed).
2.2.2 TYPE EOF and depress the RETURN key. (A prompt should be displayed asking for PASSWORD).
2.2.3 TYPE EOFUSER and depress the RETURN key.
(The EOF Plant Menu should be displayed).
2.2.4 SELECT Option I for Hope Creek.
2.2.5 DEPRESS the RETURN key. (The EOF Report Options Menu should be displayed).
2.2.6 SELECT and ENTER Option 6 (15 Minute Historical Data).
(Current system date and time should be displayed.
A prompt should be displayed for start date and time) 2.2.7 DEPRESS the RETURN key for 15 minute average RMS and MET data. (Your selection will be printed).
Nuclear Common Page 40 of 44 Rev. 03
NC.EP-EP.ZZ-0309 (Q)
ATTACHMENT 2 Page 1 of 3 OPERATING INSTRUCTIONS FOR SALEM SPDS RADIOLOGICAL SCREENS 1.0 SALEM I & 2 SPDS RADIOLOGICAL SCREEN INSTRUCTIONS 1.1 Follow The Steps Below In The Listed Order, To Display SPDS Radiological Screens.
NOTE
- Values in Red are in HIGH HIGH ALARM.
- Values in YELLOW with are in HIGH ALARM.
11.1.1 DEPRESS the UNIT MASTER MENU Key 1.1.2 DEPRESS and hold the "SHIFT" key, while depressing the Number 5 Key. [Radiation Monitor Screen 1 will be displayed.
This screen (Radiation Monitor Screen 1) consists of instantaneous values for the RMS monitors listed below].
R46A-E Main Steam Line Mon R44NB Containment Post LOCA Rad Mon RI 1A Containment Particulate R12A Containment Noble Gas R12B Containment Iodine R44A/B Integ Dose Containment Post LOCA Rad Mon 1.1.3 DEPRESS and hold the "SHIFT" key, while depressing the Number 2 Key. (Radiation Monitor Screen 2 will be Displayed). This screen (Radiation Monitor Screen
- 2) consists of RMS instantaneous monitor values listed below).
Nuclear Common Rev. 03 Page 41 of 44
NC.EP-EP.ZZ-0309 (Q)
ATTACHMENT 2 Page 2 of 3
"* R45B Plant Vent Accident Mon (Medium Range Noble Gas)
"* R45C Plant Vent Accident Mon (High Range Noble Gas)
"* R16 Plant Vent Gas Effluent
"* R41A Low Range Noble Gas
"* R41 B Mid Range Noble Gas
"* R41C High Range Noble Gas
"* R43 Aux Building Roof Mon
"* Unit 1 or 2 Noble Gas Release Rate
"* Combined Noble Gas Release Rate 1.1.4 DEPRESS and hold the "SHIFT" key, while depressing the Number 3 Key. (Radiation Monitor Screen 3 will be displayed). This screen (Radiation Monitor Screen 3) consists of RMS 15 minute average monitor values listed below).
"* R46A-E Main Steam Line Mon
"* R44A/B Containment Post LOCA Rad Mon
"* R1i1A Containment Particulate
"* R12A Containment Noble Gas
"* R12B Containment Iodine 1.1.5 DEPRESS and hold the "SHIFT" key, while depressing the Number 4 Key. (Radiation Monitor Screen 4 will be displayed.)
This screen (Radiation Monitor Screen 4) consists of RMS 15 minute average monitor values listed below).
Plant Vent Airflow to Atmosphere (Plant Vent Flow Rate)
Nuclear Common Rev. 03 Page 42 of 44
NC.EP-EP.ZZ-0309 (Q)
ATTACHMENT 2 Page 3 of 3 R45B Plant Vent Accident Mon (Medium Range Noble Gas)
R45C Plant Vent Accident Mon (High Range Noble Gas)
R16 Plant Vent Gas Effluent R41A Low Range Noble Gas 0
R41B Mid Range Noble Gas 0
R41C High Range Noble Gas R43 Aux Building Roof Mon 1.1.6 RECORD RMS values on Form - 1, SPDS RMS Log (Salem Only).
2.0 SALEM 1 & 2 SPDS RADIOLOGICAL SCREEN TRENDING INSTRUCTIONS 2.1 Perform The Steps Listed Below In The Listed Order, To Trend SPDS Radiological Monitors.
2.1.1 DISPLAY the screen that lists the monitor you want to trend.
2.1.2 DEPRESS the "DATA ENTRY FORWARD" key to move the cursor to the radiation monitor that is to be trended.
2.1.3 DEPRESS the "TREND" key.
2.1.4 DEPRESS the "Page Down" key to display the trending of the monitor.
2.1.5 DEPRESS the "Page Up" key to return to Radiation Monitor Screen 1.
3.0 RML SCREEN INSTRUCTIONS DEPRESS The RML Key To Display The Dome Screen (Instantaneous RMS Values will be displayed).
4.0 RML SCREEN INSTRUCTIONS DEPRESS The RM Key To Display Any Abnormal Or Potentially Abnormal Radiological Releases In Progress.
Nuclear Common Page 43 of 44 Rev. 03
NC.EP-EP.ZZ-0309 (Q)
FORM - 1 Page 1 of I SPDS RMS LOG (SALEM ONLY)
Date/Time:
Unit Location on SPDS Screen 1/3 Screen 1/3 Screen 1/3 Screen 1/3 Screen 1/3 Screen 1/3 Screen 1/3 Screen 1/3 Screen 1/3 Screen 1/3 Screen 4 Screen 2/4 Screen 2/4 Screen 2/4 Screen 2/4 Screen 2/4 Salem
/
Monitor Number R46A R46B R46C R46D R46E R44A R44B R11A R12A R12B R16 R41A R41B R41C R45B R45C Value of Monitor Description of Monitor Main Steam Line Mon Main Steam Line Mon Main Steam Line Mon Main Steam Line Mon Main Steam Line Mon CNTMT Post LCOA Mon CNTMT Post LOCA Mon CNTMT Particulate Mon CNTMT Noble Gas Mon CNTMT Iodine Mon Plant Vent Gas Mon Low Range Noble Gas Mon Mid Range Noble Gas Mon High Range Noble Gas Mon Plant Vent Accident Mon (Min Range Noble Gas Back-up)
Plant Vent Accident Mon (High Range Noble Gas Back-up)
Nuclear Common Units mR/hr mR/hr mR/hr mR/hr mRPhr R/hr R/hr cpm cpm cpm cpm uCi/cc uCi/cc uCi/cc uCi/cc uCi/cc Rev. 03 Page 44 of 44
PSEG Internal Use Only PSEG NUCLEAR LLC Page 1 of 1 NC.EP-EP.ZZ-0313 (Q)
Rev. 00 ADVANCED DOSE ASSESSMENT (MIDAS) INSTRUCTIONS USE CATEGORY: II REVISION
SUMMARY
CONTROL
- 1. This revision satisfies the requirement for a biennial review.
CO PY
- 2. This procedure consists of the advanced instructions to perform dose assessment (MIDAS) that were previously contained in NC.EP-EP.ZZ-0309(Q). The advanced MIDAS instructions were reformatted in this procedure to enhance the user friendliness. No revision bars were used in this procedure, due to the extensive reformatting.
- 3. Steps 5.5.22.Q and 5.6.22.K were revised to tell the user to enter 20 for ambient temperature, since MIDAS does not use this value during dose assessment calculations.
- 4. Sections 5.5 and 5.6 were revised to tell the user to use 1.0 for the default DT300, if the delta t is not available.
IMPLEMENTATION REQUIREMENTS Procedure Implementation Date:
)-- Z1-z'?) Z7
NC.EP-EP.ZZ-0313 (Q)
TABLE OF CONTENTS Section Title Page 1.0 P U R P O S E.........................................................................................................
3 2.0 PREREQUISITES........................................................................................
3 2.1 Prerequisites To Be Followed Prior To Implementing This P rocedure..........................................................................................
3 3.0 PRECAUTIONS AND LIMITATIONS............................................................
3 3.1 Precaution and Limitations To Be Followed Prior To Implementing This Procedure.................................................................................
3 4.0 EQUIPMENT REQUIRED...........................................................................
4 5.0 PROCEDURE............................................................................................
4 5.1 Sign-on Instructions For MIDAS........................................................
4 5.2 Perform the Following to Produce a SSCL Page 2 Using Back Calculation Dose Assessment Mode.................................................
5 5.3 The Following Steps Should be Performed to Calculate Liquid Release Dose Assessment For Swimmers........................................
9 5.4 The Following Steps Should be Performed to Calculate Dose Assessment Using DAPA Values (Leakage From The Drywell).....
11 5.5 Perform the Following to Produce a SSCL Page 2 Using Default Dose Assessment...........................................................................
13 5.6 Perform the Following to Produce a SSCL Page 2 Using Default Dose Assessment Based On NUREG 1228.................................... 22 6.0 RECORDS.................................................................................................
30
7.0 REFERENCES
30 7.1 References......................................................................................
30 7.2 Cross References............................................................................
30 Nuclear Common Rev. O00 Page 1 of 39
NC.EP-EP.ZZ-0313 (Q)
ATTACHMENTS Operating Instructions For VAX LA120 Terminal............................
30 Operating Instructions For Salem SPDS Radiological Screens......... 33 FORM Form - 1 SPDS RMS Log (Salem Only)...................................................................
36 TABLES TABLE 1 - 1 Drywell Rate Nomogram............................................................................
37 TABLE 1 - 2 Xu/Q Values for Elevated Releases at Hope Creek...................................
38 TABLE 1 - 3 Xu/Q Values for Ground Releases at Hope Creek.....................................
39 Nuclear Common Rev. 00 Page 2 of 39
NC.EP-EP.ZZ-0313 (Q) 1.0 PURPOSE This procedure provides guidance and operating instructions concerning performing advanced dose assessment using the dose assessment program MIDAS.
2.0 PREREQUISITES 2.1 Prerequisites to be Followed Prior to Implementing This Procedure Implement this procedure:
"* Upon the declaration of an Unusual Event or higher emergency classification.
"* At the request of the Operation Superintendent (OS).
"* At the request of the Emergency Duty Officer (EDO).
"* At the request of the Radiation Protection Duty Supervisor (RPDS) or Shift Radiation Protection Technician (SRPT).
3.0 PRECAUTIONS AND LIMITATIONS 3.1 Precautions and Limitations to be Followed Prior to Implementing this Procedure:
3.1.1 It is recommended that initials be used in the place keeping sign offs, instead of checkmarks, if more than one person may implement this procedure.
3.1.2 Steps in this procedure may be performed in the order deemed appropriate for the emergency situation. Only steps that are applicable to the specific MIDAS dose assessment mode of operation that is being performed need be followed.
3.1.3 Personnel who implement this procedure shall be trained and qualified lAW the Emergency Plan.
3.1.4 This procedure is limited to performance of advanced dose assessment calculations [Dose Assessment Based On Back Calculation, Liquid Release (Swimmers), DAPA Values, Default UFSAR, and Default NUREG 1228 Modes] and instructions on manipulation of map screens, including printing out of map screens.
Nuclear Common Page 3 of 39 Rev. 00
NC.EP-EP.ZZ-0313 (Q) 4.0 EQUIPMENT REQUIRED Necessary equipment is provided in the Emergency Response Facilities.
5.0 PROCEDURE NOTE
" Dose Assessment should be performed using 10 or 15-minute average RMS and Meteorological data, unless circumstances in step 5.1.1 are met.
" Attachment 1, Operation of the VAX LA120 Terminal, should be referred to for operational directions for the VAX LA1 20.
" Attachment 2, Instructions for Salem SPDS Displays, should be referred to for operational directions for the radiological SPDS screens, including the RM and RML screens.
5.1 Sign-on Instructions For MIDAS 5.1.1 DEPRESS the POWER button. (The Microsoft Windows NT Screen will appear with a Begin Logon box displayed. The command inside the box will read, Press Ctrl + Alt + Delete to logon).
5.1.2 DEPRESS the Ctri, Alt, Delete keys simultaneously. (The Logon Information box will be displayed with lines to enter User name and Password).
5.1.3 INPUT midas into the User name line.
5.1.4 INPUT midas into the Password line and depress the RETURN key.
5.1.5 POSITION the cursor on the Midas Icon and click the mouse twice.
(The MIDAS unit selection screen will be displayed).
5.1.6 POSITION the mouse cursor + over the box of your selection (Hope Creek, Salem Unit 1, or Salem Unit 2) and click the mouse once. (Your selection will become highlighted).
5.1.7 POSITION the cursor over the CONFIRM box and click the mouse once. (The Function Selection screen will appear).
Nuclear Common Rev. 00 Page 4 of 39
NC.EP-EP.ZZ-0313 (Q) 5.1.8 SELECT the appropriate Section for type of dose assessment mode from list below:
Refer to Section 5.2 to perform Dose Assessment Using Back Calculation.
" Refer to Section 5.3 to perform Dose Assessment for Swimmers based on a Liquid Release.
" Refer to Section 5.4 to perform Dose Assessment from DAPA Values.
" Refer to Section 5.5 to perform "What If' Dose Assessment calculations using Default mode.
Refer to Section 5.6 to perform "What If Dose Assessment calculations using Default 1228 mode.
" Refer to Attachment I for Operating Instructions for the VAX LAI20 Terminal.
"* Refer to Attachment 2 for Operating Instructions for SALEM SPDS Radiological Screens.
5.2 PERFORM THE FOLLOWING TO PRODUCE A SSCL PAGE 2 USING THE BACK CALCULATION DOSE ASSESSMENT MODE NOTE
"* Back Calculation Dose Assessment should be used if dose assessment values are needed based on onsite or offsite field team meter results.
"* While performing Back Calculation and the following appears on the screen:
NO RESPONSE FROM DADIS - HOPE CREEK TO DADIS DATA COLLECTION FROM DADIS WAS TERMINATED ENTER OPTION: [YE] TRY DATA COLLECTION AGAIN
[NO] PROCEED WITH MANUAL ENTRY Respond in the following manner: Choose NO and proceed with following the steps listed in section 5.2 of this procedure.
5.2.1 POSITION the cursor over the ACCIDENT DOSE CALCULATIONS (AC) box and CLICK the mouse once. (Your selection will become highlighted).
Nuclear Common Page 5 of 39 Rev. 00
NC.EP-EP.ZZ-0313 (Q) 5.2.2 POSITION the cursor over the CONFIRM box and CLICK the mouse once. (Your selection will become highlighted and the Accident Dose Calculations (AC) screen will appear).
5.2.3 POSITION the cursor over the FIELD TEAM STRAIGHT LINE (MENU E) box and CLICK the mouse once. The box will become highlighted.
5.2.4 POSITION the cursor over the CONFIRM box and CLICK the Mouse once. (The Field Monitoring Parameter Selection screen will then appear).
5.2.5 POSITION the cursor over the RESET box and CLICK the mouse once. (The highlighted boxes will now be cleared and data may now be inputted).
5.2.6 POSITION the cursor over the GROUND box and CLICK the mouse once. (The box will become highlighted) 5.2.7 POSITION the cursor over the FIELD MONITOR READING (MR/HR) box and CLICK the mouse once. (The box will become highlighted and a pop-up screen will appear in the upper right side of the screen).
5.2.8 POSITION the cursor over the appropriate number(s) you wish to enter and CLICK the mouse once. (The number you chose will be displayed in the top portion of the pop-up screen).
5.2.9 POSITION the cursor over the EN box and CLICK the mouse once.
(The value selected will be displayed in the FIELD MONITOR READING box).
5.2.10 POSITION the cursor over the DISTANCE FROM THE PLANT (MILES) box and CLICK the mouse once. (The box will become highlighted and a pop-up screen will appear in the upper right side of the screen).
5.2.11 POSITION the cursor over the appropriate number(s) you wish to enter and CLICK the mouse once. (The number you chose will be displayed in the top portion of the pop-up screen).
5.2.12 POSITION the cursor over the EN box and CLICK the mouse once.
(The value selected will be displayed in the FIELD MONITOR READING box).
Nuclear Common Page 6 of 39 Rev. 00
NC.EP-EP.ZZ-0313 (Q) 5.2.13 POSITION the cursor over the SILVER ZEOLITE (CPM) box and CLICK the mouse once. (The box will become highlighted and a pop-up screen will appear in the upper right side of the screen).
5.2.14 POSITION the cursor over the appropriate number(s) you wish to enter and CLICK the mouse once. (The number you chose will be displayed in the top portion of the pop-up screen).
5.2.15 POSITION the cursor over the EN box and CLICK the mouse once.
(The value selected will be displayed in the FIELD MONITOR READING box).
5.2.16 POSITION the cursor over the CONFIRM box and CLICK the mouse once. IF the calculating screen appears, THEN MIDAS is starting to perform dose assessment calculations. The SSCL will automatically printout and the 10 mile TEDE 4-DAY map will appear on the screen.
5.2.17 IF the Meteorological Spread Sheet screen appears, THEN input appropriate meteorological values.
5.2.18 POSITION the cursor to the CONTINUE box on the bottom of the screen and CLICK the mouse once. (The NEXT REPORT box will replace the CONTINUE box).
5.2.19 POSITION the cursor over the NEXT REPORT box and CLICK the mouse once. (The MORE REPORTS box will replace the NEXT REPORT box).
5.2.20 POSITION the cursor over the MORE REPORTS box and CLICK the mouse once. (The More Reports Selection screen will appear).
NOTE
"* Step 5.2.21 provides instructions for utilizing the SSCL Box to print a SSCL to the screen, if the printer is malfunctioning.
" Step 5.2.21 provides instructions for utilizing the SSCL Box to print an additional SSCL.
" A blank SSCL page 2 can be found in ECG Attachment 8 or obtained from Communicator 2.
Nuclear Common Page 7 of 39 Rev. 00
NC.EP-EP.ZZ-0313 (Q) 5.2.21 IF a SSCL needs be printed to the screen or an additional SSCL printed out, THEN:
A.
POSITION the cursor over the SSCL Box and CLICK the mouse once.
B.
POSITION the cursor over the CONFIRM box and CLICK the mouse once. (The SSCL will be printed to the screen, and if the printer is functioning, an additional SSCL will be printed out).
5.2.22 POSITION the cursor over the EXIT box and CLICK the mouse once. (The EXIT box will become highlighted).
5.2.23 CLICK the mouse again. (The Function Selection screen will appear).
5.2.24 IF another dose assessment calculation and SSCL is needed, THEN REPEAT steps 5.2.1 through 5.2.23.
5.2.25 IF you need to exit the MIDAS program, THEN:
A.
POSITION the cursor over the EXIT box and click the mouse twice. (The Unit Selection screen will appear).
B.
POSITION the cursor over the EXIT box, click the mouse twice.
Nuclear Common Rev. 00 Page 8 of 39
NC.EP-EP.ZZ-0313 (Q) 5.3 The Following Steps Should Be Performed To Calculate Liquid Release Dose Assessment For Swimmers NOTE Liquid Release Dose Assessment for Swimmers should be performed lAW Section 5.3 of this procedure.
5.3.1 PERFORM the following to perform dose assessment for swimmers.
A.
OBTAIN the gross liquid release activity from chemistry and record the value in Space A.
B.
SELECT the Dose Rate Conversion Factor from below.
Gamma External Dose Equivalent = 1.44E-06 mRem/hr/pCi/l Beta/Gamma Skin Dose Equivalent = 1.72E-06 mRem/hr/pCill C.
RECORD the value in Space D.
D.
OBTAIN the exposure time.
E.
RECORD in Space E.
NOTE
- The average yearly dilution factor for routine releases is 1.00E-03.
- The default dilution factor is 1.OQE+00 and should be used if the dilution factor is unknown.
F.
OBTAIN the dilution factor from chemistry or use the default value.
G.
RECORD value in Space F.
Nuclear Common Page 9 of 39 Rev. 00
NC.EP-EP.ZZ-0313 (Q)
H.
MULITPLY the value in Space A by the value in Space B. (The value calculated will be the total concentration of the liquid release).
I.
RECORD the value in space C.
J.
MULTIPLY the values from Spaces C, D, E and F to (The calculated value will be the External Dose Equivalent (EDE) dose).
K.
RECORD the value in Space G.
A.
Gross Liquid Activity (uCi/ml)
D.
DRCF (mRem/hr/pCi/l)
G.
EDE in mRem
- B. 1.OOE+09 Conversion Factor E.
Exposure Time
=C.
Total Concentration (pCi/I)
- F.
Dilution Factor (Hours)
Nuclear Common Rev. 00 Page 10 of 39
NC.EP-EP.ZZ-0313 (Q) 5.4 The Following Steps Should Be Performed To Calculate Dose Assessment DAPA Values (Leakage From The Drywell)
NOTE Section 5.4 of this procedure is for HOPE CREEK ONLY and should be used to perform Leakage from the Drywell Dose Assessment using DAPA Values.
5.4.1 OBTAIN the DAPA "A" or "B" monitor value (which ever one is the highest) and record this value on the horizontal axis of Table 1 - 1, Drywell (Primary Containment) High Range Monitor Response (DAPA) R/hr.
5.4.2 MULTIPLY the leak rate in uCi/sec by 1.00E-03 to obtain percent of Drywell Leakage. [The leak rate in uCi/sec may be obtained from the RM-1 1 or the VAX LA1 20.
IF the Reactor Building Ventilation hasn't been isolated, THEN use 9RX580 (FRVS Effluent Monitor Reading)].
[IF the Reactor Building Ventilation has been isolated, THEN use 9RX680 (SPV Effluent Monitor Reading)].
5.4.3 RECORD the percent of Drywell Leakage on Table 1-1 by choosing the most appropriate diagonal line.
(100% 2 hrs, 100%, 10%, 1.0%,0.5%, or 0.1%)
5.4.4 LOCATE where the DAPA monitor value and the percent leakage intersect on Table 1 - 1.
5.4.5 DRAW a line from this point of intersection to Scale "A" titled Release Rate (uCi/sec).
5.4.6 PERFORM the following steps to determine the XIQ value on Scale "B":
A.
DIVIDE the wind speed (mph) by 2.24 to obtain the wind speed in m/sec.
B.
RECORD the wind speed in the wind speed blank (Step 5.4.7).
C.
REFER to Table 1 - 2 for an elevated release OR REFER to Table 1 - 3 for a ground release and locate the specific distance of interest.
Nuclear Common Page 11 of 39 Rev. 00
NC.EP-EP.ZZ-0313 (Q)
D.
FOLLOW the appropriate table over to the right to the current Stability Class.
E.
MULTIPLY this value by 1.OOE-06.
F.
RECORD the value in the Xu/Q blank (Step 5.4.7).
G.
DIVIDE the Xu/Q value by the wind speed in m/sec.
and record the value in the X/Q blank.
5.4.7 LOCATE the approximate X/Q value on Scale "B" and plot the value.
Xu/Q /wind speed (m/sec)
X/Q 5.4.8 DRAW a straight line from the point of interest on Scale "A" to the X/Q value located on Scale "B".
5.4.9 CONTINUE TO DRAW the line to the point of intersection on Scale "C".
5.4.10 DETERMINE by interpolation the approximate value of the intercept point on Scale "C". (This is the projected external dose equivalent (EDE) offsite dose rate in mRem/hr).
5.4.11 MULTIPLY this value by four to obtain a four-hour projected EDE dose.
NOTE The TEDE + 4 to EDE Correction Factor is 1.
5.4.12 MULTIPLY the EDE dose by I to obtain the four-hour projected TEDE dose.
Nuclear Common Page 12 of 39 Rev. 00
NC.EP-EP.ZZ-0313 (Q) 5.5 Perform The Following To Produce A SSCL Page 2 Using Default Dose Assessment Mode 5.5.1 POSITION the cursor over the ACCIDENT DOSE CALCULATIONS (AC) box and CLICK the mouse once.
(Your selection will become highlighted).
5.5.2 POSITION the cursor over the CONFIRM box and CLICK the mouse once. (Your selection will become highlighted and the Accident Dose Calculations (AC) screen will appear).
5.5.3 POSITION the cursor over ADVANCED CALCS ALL SCREENS (MENU X) and CLICK the mouse once. (Your selection will become highlighted).
5.5.4 POSITION the cursor over the CONFIRM box and CLICK the mouse once. (The box will become highlighted.
MIDAS will attempt to collect automatic data. The Miscellaneous Parameters screen will then appear).
5.5.5 PERFROM the following to highlight appropriate selections:
A.
POSITION the cursor over the RESET box and CLICK the mouse. No boxes will now be highlighted.
B.
POSITION the cursor over the MANUAL box and CLICK the mouse once.
Nuclear Common NOTE While performing "WHAT IF" DEFAULT dose assessment calculations, the following appears on the screen:
NO RESPONSE FROM DADIS - (HOPE CREEK/SALEM) TO DADIS DATA COLLECTION FROM DADIS WAS TERMINATED ENTER OPTION: [YE] TRY DATA COLLECTION AGAIN
[NO] PROCEED WITH MANUAL ENTRY Respond in the following manner:
Choose NO and proceed with Section 5.5 of this procedure.
Section 5.5 of this procedure should only be used to perform "WHAT IF" DEFAULT dose assessment calculations and should NOT be used for event classifications or protective action recommendations.
Page 13 of 39 Rev. 00
NC.EP-EP.ZZ-0313 (Q)
C.
POSITION the cursor over the appropriate RELEASE POINT(S) and CLICK the mouse once.
(The box will become highlighted).
D.
POSITION the cursor over the FLOW EX VEL (CFM) box for the release point chosen and CLICK the mouse once. (A pop-up screen will appear).
E.
INPUT the exit velocity flow rate using the pop-up screen by positioning the cursor over the correct value(s) and CLICKING the mouse once.
Exit Velocity For HOPE CREEK: ZERO (0) for all REL PTs.
Exit Velocity For SALEM: ZERO (0) for REL PTs. 1 and 4 Exit Velocity For SALEM: 95 for REL PT 2 F.
INPUT the exit velocity flow rate using the pop-up screen by positioning the cursor over the correct Value(s), selected from above, and CLICKING the mouse once.
G.
POSITION the cursor over the EN box when the appropriate values are inputted and CLICK the mouse once. (The box will become highlighted with the flow rate inside the box).
H.
POSITION the cursor over the MAX DIST DOWNWIND (MILES) box and CLICK the mouse once. A pop-up screen will appear.
I.
INPUT 10 using the pop-up screen.
J.
POSITION the cursor over the EN box and CLICK the mouse once. (The box will become highlighted with 10 appearing inside the box).
5.5.6 POSITION the cursor over the AUTO SCENARIO INTEGRATION box and CLICK the mouse once. (The box will become highlighted).
5.5.7 POSITION the cursor over the CONFIRM box and CLICK the mouse once. (The box will become highlighted and Run Mode and Integration screen will appear).
Nuclear Common Rev. 00 Page 14 of 39
NC.EP-EP.ZZ-0313 (Q) 5.5.8 POSITION the cursor over the PROJECTED (FORECAST)
DOSE box.
5.5.9 IF the PROJECTED (FORECAST) DOSE is highlighted, THEN GO to step 5.5.11.
5.5.10 IF the PROJECTED (FORECAST) DOSE box is not highlighted, THEN place the cursor on the box and CLICK the mouse once.
5.5.11 POSITION the cursor over the START DATE INTEG.
CURRENT Box and CLICK the mouse once.
5.5.12 IF the PROJ. TIMES (HRS) box DOES have.25, 1, 4, 24 inside of the box and is highlighted, THEN go to Step 5.5.14.
5.5.13 IF the PROJ. TIMES (HRS) box DOESN'T have.25, 1,4, 24 inside of box, THEN POSITION the cursor over the PROJ. TIMES (HRS) box and CLICK the mouse once. (A pop-up screen will appear in the upper right of the screen).
A.
INPUT.25, 1, 4, 24 using the pop-up screen.
B.
POSITION the cursor over the EN box and CLICK the mouse once.
5.5.14 POSITION the cursor over the CONFIRM box and CLICK the mouse once. (The box will become highlighted and the Release Option Selection screen will appear).
5.5.15 POSITION the cursor over the DEFAULT DBA ACCIDENT box and CLICK the mouse once. (The box will become highlighted).
5.5.16 POSITION the cursor over the CONFIRM box and CLICK the mouse once. (The Design Basis Accident Selection screen for the release point selected will appear).
5.5.17 POSITION the cursor over the appropriate accident and CLICK the mouse once. (The box will become highlighted) 5.5.18 POSITION the cursor over the appropriate selection(s) and CLICK the mouse once. (The Release Timing Selection screen will appear).
Nuclear Common Rev. 00 Page 15 of 39
NC.EP-EP.ZZ-0313 (Q) 5.5.19 POSITION the cursor over the TRIP CURRENT TIME box and CLICK the mouse once.
5.5.20 POSITION the cursor over the CONFIRM box and CLICK the mouse once. (The box will become highlighted and the Release Option Selection screen will appear).
5.5.21 POSITION the cursor over the CONFIRM box and CLICK the mouse once. (DO NOT ENTER ANY VALUES IN THE DURATION OR REMAINING DURATION BOXES. The Weather Selection screen will appear).
5.5.22 PERFORM the following steps to input meteorological data:
NOTE The user will NOT be prompted for the SPD33P (MPH) if the release is an elevated release.
A.
POSITION the cursor over the SPD33P (MPH) box and CLICK the mouse once to input the 33 foot elevation wind speed.
B.
POSITION the cursor over the appropriate number(s) you wish to enter and CLICK the mouse once. (The number you chose will be displayed in the top portion of the pop-up screen).
C.
MOVE the cursor over the EN box and CLICK the mouse once. [The value chosen will be displayed in specific weather parameter box that is being inputted (i.e. SPD33P MPH)].
NOTE The user will NOT be prompted for the SPD300 (MPH) if the release is a ground release.
D.
POSITION the cursor over the SPD300 (MPH) box and CLICK the mouse once to input the 300 foot elevation wind speed.
Nuclear Common Page 16 of 39 Rev. 00
NC.EP-EP.ZZ-0313 (Q)
E.
POSITION the cursor over the appropriate number(s) you wish to enter and CLICK the mouse once. (The number you chose will be displayed in the top portion of the pop-up screen).
F.
MOVE the cursor over the EN box and CLICK the mouse once. (The value chosen will be displayed in specific weather parameter box).
NOTE The Default Value of one (1.0) should be used for DT300, if the delta t data is not available. This will produce an "E" stability class.
G.
POSITION the cursor over the DT300 (DEG.C) box and CLICK the mouse once to input the 300 - 33 foot delta temperature. (The box will become highlighted).__
H.
POSITION the cursor over the appropriate number(s) you wish to enter and CLICK the mouse once. (The number you chose will be displayed in the top portion of the pop-up screen).
- 1.
MOVE the cursor over the EN box and CLICK the mouse once. (The value chosen will be displayed in specific weather parameter box).
NOTE MIDAS does not use ambient temperature value. Twenty (20) degrees should be used for ambient temperature.
J.
POSITION the cursor over the TEMP33 (DEG.C) box and CLICK the mouse once to input the ambient temperature.(The box will become highlighted).
K.
POSITION the cursor over the appropriate number 20 and CLICK the mouse once. (The number 20 will be displayed in the top portion of the pop-up screen).
L.
MOVE the cursor over the EN box and CLICK the mouse once. (The value chosen will be displayed in specific weather parameter box).
Nuclear Common Page 17 of 39 Rev. 00
NC.EP-EP.ZZ-0313 (Q)
M.
POSITION the cursor over the DIR33P (DEG.C) box and CLICK the mouse once to input the 33 foot wind direction. (The box will become highlighted).
N.
POSITION the cursor over the appropriate number(s) you wish to enter and CLICK the mouse once. (The number you chose will be displayed in the top portion of the pop-up screen).
- 0.
MOVE the cursor over the EN box and CLICK the mouse once. (The value chosen will be displayed in specific weather parameter box).
P.
POSITION the cursor over the RAIN (INCHES) box and CLICK the mouse once to input the 15 minute average precipitation. (The box will become highlighted).
NOTE The following values of values may be inputted if actual rainfall data is not known:
- 0.08 = (Heavy Rainfall)
- 0.02 = (Moderate Rainfall)
- 0.01 = (Light Rainfall)
- The number Zero "0" if it is not raining.
Q.
POSITION the cursor over the appropriate number(s)
You wish to enter and CLICK the mouse once. (The number you chose will be displayed in the top portion of the pop-up screen).
R.
MOVE the cursor over the EN box and CLICK the mouse once. (The value chosen will be displayed in specific weather parameter box).
Nuclear Common NOTE The PCT CLOUD COVER REQUIRES SPEED, USE LAST MET DATE, and USE DEFAULT MET boxes should NOT be used.
Rev. 00 Page 18 of 39
NC.EP-EP.ZZ-0313 (Q)
S.
POSITION the cursor over CONFIRM box and CLICK the mouse once. (The Rad Monitoring Channel screen will appear).
5.5.23 POSITION the cursor over the CONTINUE box and CLICK the mouse once. (The box will become highlighted and Release Point Data screen will appear).
5.5.24 POSITION the cursor over the CONTINUE box and CLICK the mouse once. (The box will become highlighted and the Summary of Meteorological Data screen will appear).
5.5.25 POSITION the cursor over CONTINUE box and CLICK the mouse once. (The calculating screen will appear, while PC MIDAS performs dose assessment calculations. The SSCL will automatically printout and the 10 mile TEDE 4-DAY map will appear on the screen after the calculations are finished).
5.5.26 POSITION the cursor to the CONTINUE box on the bottom of the screen and CLICK the mouse once.
(The NEXT REPORT box will replace the CONTINUE box).
5.5.27 POSITION the cursor over the NEXT REPORT box and CLICK the mouse once. (The MORE REPORTS box will replace the NEXT REPORT box).
5.5.28 POSITION the cursor over the MORE REPORTS box and CLICK the mouse once. (The More Reports Selection screen will appear).
NOTE Step 5.5.29 provides instructions for utilizing the SSCL Box to print a SSCL to the screen, if the printer is malfunctioning.
Step 5.5.29 provides instructions for utilizing the SSCL Box to print an additional SSCL.
A blank SSCL page 2 can be found in ECG Attachment 8 or obtained from Communicator 2.
5.5.29 IF a SSCL needs be printed to the screen or another SSCL printed out, THEN:
Nuclear Common Rev. O00 Page 19 of 39
NC.EP-EP.ZZ-0313 (Q)
A.
POSITION the cursor over the SSCL Box and CLICK the mouse once.
B.
POSITION the cursor over the CONFIRM box and CLICK the mouse once. (The SSCL will be printed to the screen, and if the printer is functioning, another SSCL will be printed out).
5.5.30 POSITION the cursor over the EXIT box and CLICK the Mouse once. (The EXIT box will become highlighted).
5.5.31 CLICK the mouse again. (The Function Selection screen will appear).
5.5.32 IF another dose assessment calculation and SSCL is needed, THEN REPEAT steps 5.5.1 through 5.5.30.
5.5.33 IF you need to exit the MIDAS program, THEN:
A.
POSITION the cursor over the EXIT box and click the mouse twice. (The Unit Selection screen will appear).
B.
POSITION the cursor over the EXIT box, click the mouse twice.
Nuclear Common Rev. O00 Page 20 of 39
NC.EP-EP.ZZ-0313 (Q) 5.6 Perform The Following To Produce A SSCL Page 2 Using The Default Dose Assessment Based On NUREG 1228 Mode 5.6.1 POSITION the cursor over the ACCIDENT DOSE CALCULATIONS (AC) box and CLICK the mouse once.
(Your selection will become highlighted).
5.6.2 POSITION the cursor over the CONFIRM box and CLICK the mouse once. [Your selection will become highlighted and the Accident Dose Calculations (AC) screen will appear].
5.6.3 POSITION the cursor over ADVANCED CALCS ALL SCREENS (MENU X) and CLICK the mouse once. (Your selection will become highlighted).
5.6.4 POSITION the cursor over the CONFIRM box and CLICK the mouse once. (The box will become highlighted.
MIDAS will attempt to collect automatic data. The Miscellaneous Parameters screen will then appear).
5.6.5 PERFROM the following to highlight appropriate selections:
A.
POSITION the cursor over the RESET box and CLICK the mouse. No boxes will now be highlighted.
B.
POSITION the cursor over the MANUAL box and CLICK the mouse once.
Nuclear Common NOTE
" While performing NUREG 1228 "WHAT IF" DEFAULT dose assessment calculations, the following appears on the screen:
NO RESPONSE FROM DADIS - (HOPE CREEK/SALEM) TO DADIS DATA COLLECTION FROM DADIS WAS TERMINATED ENTER OPTION: [YE] TRY DATA COLLECTION AGAIN
[NO] PROCEED WITH MANUAL ENTRY Respond in the following manner:
Choose NO and proceed with Section 5.6 of this procedure.
" Section 5.6 of this procedure should only be used to perform "WHAT IF" NUREG 1228 DEFAULT dose assessment calculations and should NOT be used for event classifications or protective action recommendations.
Page 21 of 39 Rev. 00
NC.EP-EP.ZZ-0313 (Q)
C.
POSITION the cursor over the appropriate RELEASE POINT(S) and CLICK the mouse once.
(The box will become highlighted).
D.
POSITION the cursor over the FLOW EX VEL (CFM) box for the release point chosen and CLICK the mouse once. (A pop-up screen will appear).
E.
INPUT the exit velocity flow rate using the pop-up screen by positioning the cursor over the correct values and CLICKING the mouse once.
Exit Velocity For HOPE CREEK: ZERO (0) for all REL PTs.
"* Exit Velocity For SALEM: ZERO (0) for REL PTs. 1 and 4
"* Exit Velocity For SALEM: 95 for REL PT 2 F.
POSITION the cursor over the EN box when the appropriate values are inputted and CLICK the mouse once. (The box will become highlighted with the flow rate inside the box).
G.
POSITION the cursor over the MAX DIST DOWNWIND (MILES) box and CLICK the mouse once. A pop-up screen will appear.
H.
INPUT 10 using the pop-up screen.
I.
POSITION the cursor over the EN box and CLICK the mouse once. (The box will become highlighted with 10 appearing inside the box).
5.6.6 POSITION the cursor over the AUTO SCENARIO INTEGRATION box and CLICK the mouse once. (The box will become highlighted).
5.6.7 POSITION the cursor over the CONFIRM box and CLICK the mouse once. (The box will become highlighted and Run Mode and Integration screen will appear).
5.6.8 POSITION the cursor over the PROJECTED (FORECAST)
DOSE box.
5.6.9 IF the PROJECTED (FORECAST) DOSE is highlighted, THEN GO to step 5.6.11.
Nuclear Common Rev. O00 Page 22 of 39
NC.EP-EP.ZZ-0313 (Q) 5.6.10 IF the PROJECTED (FORECAST) DOSE box is not highlighted, THEN position the cursor over the box and CLICK the mouse once.
5.6.11 POSITION the cursor over the START DATE INTEG.
CURRENT Box.
5.6.12 IF the PROJ. TIMES (HRS) box DOES have.25, 1, 4, 24 inside of the box and is highlighted, THEN go to Step 5.6.14.
5.6.13 IF the PROJ. TIMES (HRS) box doesn't have.25, 1, 4, 24 inside of it and is not highlighted, THEN POSITION the cursor over the PROJ. TIMES (HRS) box and CLICK the mouse once. (A pop-up screen will appear in the upper right of the screen).
A.
INPUT.25, 1, 4, 24 using the pop-up screen.
B.
POSITION the cursor over the EN box and CLICK the mouse once.
5.6.14 POSITION the cursor over the CONFIRM box and CLICK the mouse once. (The box will become highlighted and the Release Option Selection screen will appear).
5.6.15 POSITION the cursor over the EVENT TREE NUREG 1228 box and CLICK the mouse once. (The box will become highlighted).
5.6.16 POSITION the cursor over the CONFIRM box and CLICK the mouse once. (The Event Tree NUREG 1228 Selection screen for the different NUREG 1228 default accidents will appear).
5.6.17 POSITION the cursor over the appropriate accident and CLICK the mouse once. (Choices for the specific accident selected will appear).
5.6.18 POSITION the cursor over the appropriate selection(s) and CLICK the mouse once. (The Release Timing Selection screen will appear).
5.6.19 POSITION the cursor over the TRIP CURRENT TIME box and CLICK the mouse once.
5.6.20 POSITION the cursor over the RELEASE START SAME AS TRIP DATE box and CLICK the mouse once.
Nuclear Common Rev. 00 Page 23 of 39
NC.EP-EP.ZZ-0313 (Q) 5.6.21 POSITION the cursor over the CONFIRM box and CLICK the mouse once. (DO NOT ENTER ANY VALUES IN THE DURATION OR REMAINING DURATION BOXES. The Weather Selection screen will appear).
5.6.22 PERFORM the following steps to input meteorological data:
NOTE The user will NOT be prompted for the SPD33P (MPH) if the release is an elevated release.
A.
POSITION the cursor over the SPD33P (MPH) box and CLICK the mouse once to input the 33 foot elevation wind speed.
B.
POSITION the cursor over the appropriate number(s)
You wish to enter and CLICK the mouse once. (The number you chose will be displayed in the top portion of the pop-up screen).
C.
MOVE the cursor over the EN box and CLICK the mouse once. [The value chosen will be displayed in specific weather parameter box that is being inputted (i.e. SPD33P MPH)].
NOTE The user will NOT be prompted for the SPD300 (MPH) if the release is a ground release.
D.
POSITION the cursor over the SPD300 (MPH) box and CLICK the mouse once to input the 300 foot elevation wind speed.
E.
POSITION the cursor over the appropriate number(s)
You wish to enter and CLICK the mouse once. (The number you chose will be displayed in the top portion of the pop-up screen).
Nuclear Common Rev. O00 Page 24 of 39
NC.EP-EP.ZZ-0313 (Q)
F.
MOVE the cursor over the EN box and CLICK the mouse once. (The value chosen will be displayed in specific weather parameter box).
NOTE The Default Value of one (1.0) should be used for DT300, if the delta t data is not available. This will produce an "E" stability class.
G.
POSITION the cursor over the DT300 (DEG.C) box and CLICK the mouse once to input the 300 - 33 foot delta temperature. (The box will become highlighted).
H.
POSITION the cursor over the appropriate number(s) you wish to enter and CLICK the mouse once. (The number you chose will be displayed in the top portion of the pop-up screen).
- 1.
MOVE the cursor over the EN box and CLICK the mouse once. (The value chosen will be displayed in specific weather parameter box).
NOTE MIDAS does not use the value used for the ambient temperature. Twenty (20) degress should be used.
J.
POSITION the cursor over the TEMP33 (DEG.C) box and CLICK the mouse once to input the ambient temperature. (The box will become highlighted).
K.
INPUT the value 20 and CLICK the mouse once. (The number 20 will be displayed in the top portion of the pop-up screen).
L.
MOVE the cursor over the EN box and CLICK the mouse once. (The value chosen will be displayed in specific weather parameter box).
Nuclear Common Page 25 of 39 Rev. 00
NC.EP-EP.ZZ-0313 (Q)
M.
POSITION the cursor over the DT300 (DEG.C) box and CLICK the mouse once to input the 300 - 33 foot delta temperature. (The box will become highlighted).
N.
POSITION the cursor over the appropriate number(s) you wish to enter and CLICK the mouse once. (The number you chose will be displayed in the top portion of the pop-up screen).
- 0.
MOVE the cursor over the EN box and CLICK the mouse once. (The value chosen will be displayed in specific weather parameter box).
P.
POSITION the cursor over the RAIN (INCHES) box and CLICK the mouse once to input the 15 minute average precipitation. (The box will become highlighted).
NOTE The following values may be inputted if actual rainfall data is not known:
- 0.08 = (Heavy Rainfall)
- 0.02 = (Moderate Rainfall)
- 0.01 = (Light Rainfall)
- The number Zero "0" if it is not raining.
Q.
POSITION the cursor over the appropriate number(s)
You wish to enter and CLICK the mouse once. (The number you chose will be displayed in the top portion of the pop-up screen).
R.
MOVE the cursor over the EN box and CLICK the mouse once. (The value chosen will be displayed in specific weather parameter box).
Nuclear Common NOTE The PCT CLOUD COVER REQUIRES SPEED, USE LAST MET DATE, and USE DEFAULT MET boxes should NOT be used.
Page 26 of 39 Rev. O00
NC.EP-EP.ZZ-0313 (Q)
S.
POSITION the cursor over CONFIRM box and CLICK the mouse once. (The Rad Monitoring Channel screen will appear).
5.6.23 POSITION the cursor over the CONTINUE box and CLICK the mouse once. (The box will become highlighted and Release Point Data screen will appear).
5.6.24 POSITION the cursor over the CONTINUE box and CLICK the mouse once. (The box will become highlighted and the Summary of Meteorological Data screen will appear).
5.6.25 POSITION the cursor over CONTINUE box and CLICK the mouse once. (The calculating screen will appear, while PC MIDAS performs dose assessment calculations. The SSCL will automatically printout and the 10 mile TEDE 4-DAY map will appear on the screen after the calculations are finished).
5.6.26 POSITION the cursor to the CONTINUE box on the bottom of the screen and CLICK the mouse once.
(The NEXT REPORT box will replace the CONTINUE box).
5.6.27 POSITION the cursor over the NEXT REPORT box and CLICK the mouse once. (The MORE REPORTS box will replace the NEXT REPORT box).
5.6.28 POSITION the cursor over the MORE REPORTS box and CLICK the mouse once. (The More Reports Selection screen will appear).
Nuclear Common NOTE Step 5.6.29 provides instructions for utilizing the SSCL Box to print a SSCL to the screen, if the printer is malfunctioning.
" Step 5.6.29 provides instructions for utilizing the SSCL Box to print an additional SSCL.
A blank SSCL page 2 can be found in ECG Attachment 8 or obtained from Communicator 2.
Page 27 of 39 Rev. 00
NC.EP-EP.ZZ-0313 (Q) 5.6.29 IF a SSCL needs be printed to the screen or another SSCL printed out, THEN:
A.
POSITION the cursor over the SSCL Box and CLICK the mouse once.
B.
POSITION the cursor over the CONFIRM box and CLICK the mouse once. (The SSCL will be printed to the screen, and if the printer is functioning, another SSCL will be printed out).
5.6.30 POSITION the cursor over the EXIT box and CLICK the Mouse once. (The EXIT box will become highlighted).
5.6.31 CLICK the mouse again. (The Function Selection screen will appear).
5.6.32 IF another dose assessment calculation and SSCL is needed, THEN REPEAT steps 5.6.1 through 5.6.30.
5.6.33 IF you need to exit the MIDAS program, THEN:
A.
POSITION the cursor over the EXIT box and click the mouse twice. (The Unit Selection screen will appear).
B.
POSITION the cursor over the EXIT box, click the mouse twice.
Nuclear Common Page 28 of 39 Rev. 00
NC.EP-EP.ZZ-0313 (Q) 6.0 RECORDS Return completed procedure and any information or data thought to be pertinent by the dose assessor, to the Emergency Preparedness Manager.
7.0 REFERENCES
7.1 References 7.1.1 EPA 400, Manual of Protective Action Guides And Protective Actions For Nuclear Incidents 7.1.2 MIDAS Documentation Volumes 1-5 7.1.3 PSEG Nuclear Emergency Plan 7.2 Cross References 7.2.1 NC.EP-EP.ZZ-0310(Q), Radiation Protection Supervisor-Offsite and Field Monitoring Team Response 7.2.2 HC.EP-EP.ZZ-0301(Q), Shift Radiation Protection Response 7.2.3 SC.EP-EP.ZZ-0301(Q), Shift Radiation Protection Response Nuclear Common Page 29 of 39 Rev. 00
NC.EP-EP.ZZ-0313 (Q)
ATTACHMENT I Page 1 of 3 OPERATION OF THE VAX LAI20 TERMINAL 1.0 METEOROLOGICAL DATA 1.1 Perform The Following to Obtain Current 15 Minute Average Meteorological Data:
1.1.1 DEPRESS the RETURN key. (USERNAME should be displayed).
1.1.2 TYPE M E T and depress the RETURN key NOTE The most current meteorological data should be printed out followed by the Main Meteorological Menu. If no other keys are depressed, the current 15 minute average meteorological data will be printed out every 15 minutes.
1.1.3 ENTER Option I (Display Current Meteorological Data) and depress the RETURN key to receive the current 15 meteorological data print out.
1.2 Perform The Following Steps to Obtain Archived Meteorological Data:
1.2.1 DEPRESS the RETURN key. (USERNAME should be displayed) 1.2.2 TYPE M E T and depress the RETURN key. (The most current meteorological data should be printed out followed by the Main Meteorological Menu).
1.2.3 ENTER Option 2 (Display Meteorological Data From Data Base) and depress the RETURN key. (Current system Date and Time will be displayed).
Nuclear Common Rev. O00 Page 30 of 39
NC.EP-EP.ZZ-0313 (Q)
ATTACHMENT I Page 2 of 3 1.2.4 IF this is the data you want, THEN depress the RETURN key. (Your option will be printed out).
1.2.5 IF you want data from another date and time, THEN go to Step 1.2.6.
1.2.6 ENTER START DATE and TIME as shown below and depress the RETURN key. (For December 27, 1989 at 0130 enter 27-DEC-1 989 "depress the space bar once" and enter 01:30).
"* ENTER "Y" if the information is CORRECT.
"* ENTER "N" if the information is NOT CORRECT and reenter data as shown in Step 1.2.6.
1.2.7 ENTER the END DATE and TIME as shown below and depress the RETURN key. (For December 28, 1989 at 0230 enter 28-DEC-1 989 "depress the space bar once" and enter 02:30).
"* ENTER "Y" if the information is CORRECT.
"* ENTER "N" if the information is NOT CORRECT and reenter data as shown in Step 1.2.7.
2.0 RMS AND MET DATA (FOR HOPE CREEK ONLY) 2.1 Perform The Following Steps to Obtain Current Instantaneous RMS and MET Data:
2.1.1 DEPRESS the RETURN key. (USERNAME should be displayed).
2.1.2 TYPE E O F and depress the RETURN key. (A prompt should be displayed asking for PASSWORD).
2.1.3 TYPE E O F U S E R and depress the RETURN key.
(The EOF Plant Menu should be displayed.)
Nuclear Common Page 31 of 39 Rev. 00
NC.EP-EP.ZZ-0313 (Q)
ATTACHMENT 1 PAGE 3 OF 3 2.1.4 SELECT Option 1 for Hope Creek.
2.1.5 DEPRESS the RETURN key. (The EOF Report Options Menu will be displayed).
2.1.6 ENTER Option I (Current RMS Status) and depress the RETURN key. (The most current instantaneous RMS and 15 minute MET data will be printed out.)
2.2 Perform The Following Steps to Obtain 15 Minute Average RMS Data:
2.2.1 DEPRESS the RETURN key. (USERNAME should be displayed).
2.2.2 TYPE E 0 F and depress the RETURN key. (A prompt should be displayed asking for PASSWORD).
2.2.3 TYPE E 0 F U S E R and depress the RETURN key. (The EOF Plant Menu should be displayed).
2.2.4 SELECT Option I for Hope Creek.
2.2.5 DEPRESS the RETURN key. (The EOF Report Options Menu should be displayed).
2.2.6 SELECT and ENTER Option 6 (15 Minute Historical Data).
(Current system date and time should be displayed. A prompt should be displayed for start date and time) 2.2.7 DEPRESS the RETURN key for 15 minute average RMS and MET data. (Your selection will be printed).
Nuclear Common Page 32 of 39 Rev. 00
NC.EP-EP.ZZ-0313 (Q)
ATTACHMENT 2 Page 1 of 3 INSTRUCTIONS FOR SALEM SPDS DISPLAYS 1.0 SALEM I & 2 SPDS RADIOLOGICAL SCREEN INSTRUCTIONS 1.1 Follow The Steps Below In The Listed Order, To Display SPDS Radiological Screens.
NOTE
"* Values in Red are in HIGH HIGH ALARM.
"* Values in YELLOW with are in HIGH ALARM.
Form - 1, SPDS RMS Log, may be used to record SPDS RMS values.
1.1.1 DEPRESS the UNIT MASTER MENU Key 1.1.2 DEPRESS and hold the "SHIFT" key, while depressing the Number 5 Key. (Radiation Monitor Screen 1 will be displayed).
This screen (Radiation Monitor Screen 1) consists of instantaneous values for the RMS monitors listed below).
R46A-E Main Steam Line Mon R44A/B Containment Post LOCA Rad Mon R11A Containment Particulate R12A Containment Noble Gas R12B Containment Iodine R44A/B Integ Dose Containment Post LOCA Rad Mon 1.1.3 DEPRESS and hold the "SHIFT" key, while depressing the Number 2 Key. (Radiation Monitor Screen 2 will be displayed). This screen consists (Radiation Monitor Screen
- 2) of RMS instantaneous monitor values listed below).
Nuclear Common Page 33 of 39 Rev. 00
NC.EP-EP.ZZ-0313 (Q)
ATTACHMENT 2 Page 2 of 3 R45B Plant Vent Accident Mon (Medium Range Noble Gas)
R45C Plant Vent Accident Mon (High Range Noble Gas)
R16 Plant Vent Gas Effluent R41A Low Range Noble Gas R41B Mid Range Noble Gas 0
R41C High Range Noble Gas 0
R43 Aux Building Roof Mon Unit 1 or 2 Noble Gas Release Rate Combined Noble Gas Release Rate 1.1.4 DEPRESS and hold the "SHIFT" key, while depressing the Number 3 Key. (Radiation Monitor Screen 3 will be displayed). This screen (Radiation Monitor Screen 3) consists of RMS 15 minute average monitor values listed below).
R46A-E Main Steam Line Mon R44A/B Containment Post LOCA Rad Mon R11A Containment Particulate R12A Containment Noble Gas R12B Containment Iodine 1.1.5 DEPRESS and hold the "SHIFT" key, while depressing the Number 4 Key. (Radiation Monitor Screen 4 will be displayed). This screen (Radiation Monitor Screen 4) consists of RMS 15 minute average monitor values listed below).
Plant Vent Airflow to Atmosphere (Plant Vent Flow Rate)
R45B Plant Vent Accident Mon (Medium Range Noble Gas)
Nuclear Common Page 34 of 39 Rev. 00
NC.EP-EP.ZZ-0313 (Q)
ATTACHMENT 2 Page 3 of 3 0
R45C Plant Vent Accident Mon (High Range Noble Gas)
R16 Plant Vent Gas Effluent 0
R41A Low Range Noble Gas R41B Mid Range Noble Gas R41C High Range Noble Gas R43 Aux Building Roof Mon 1.1.6 RECORD RMS values on Form - 1, SPDS RMS Log (Salem Only).
2.0 SALEM 1 & 2 SPDS RADIOLOGICAL SCREEN TRENDING INSTRUCTIONS 2.1 Perform The Steps Listed Below In The Listed Order, To Trend SPDS Radiological Monitors.
2.1.1 DISPLAY the screen that lists the monitor you want to trend.
2.1.2 DEPRESS the "DATA ENTRY FORWARD" key to move the cursor to the radiation monitor that is to be trended.
2.1.3 DEPRESS the "TREND" key.
2.1.4 DEPRESS the "Page Down" key to display the trending of the monitor.
2.1.5 DEPRESS the "Page Up" key to return to Radiation Monitor Screen 1.
3.0 RML SCREEN INSTRUCTIONS DEPRESS The RML Key To Display The Dome Screen.
(Instantaneous RMS Values will be displayed).
4.0 RML SCREEN INSTRUCTIONS DEPRESS The RM Key To Display Any Abnormal Or Potential Abnormal Radiological Releases In Progress.
Nuclear Common Rev. 00 Page 35 of 39
NC.EP-EP.ZZ-0313 (Q)
FORM - I Page 1 of I SPDS RMS LOG (SALEM ONLY)
Date/Time:
/
Location on Monitor SPDS Number Desc Screen 1/3 R46A Main Screen 1/3 R46B Main Screen 1/3 R46C Main Screen 1/3 R46D Main Screen 1/3 R46E Main Screen 1/3 R44A CNTr Screen 1/3 R44B CNT*
Screen 1/3 R11A CNTI Screen 1/3 R12A CNT*
Screen 1/3 R12B CNTi Screen 4 R16 Plant Screen 2/4 R41A Low Mon Screen 2/4 R41B Mid F Mon Screen 2/4 R41C High Mon Screen 2/4 R45B Plant Screen 2/4 R45C (Min Back Plant (High Back Salem Unit ription of Monitor Steam Line Mon Steam Line Mon Steam Line Mon Steam Line Mon Steam Line Mon OT Post LCOA Mon OT Post LOCA Mon viT Particulate Mon VIT Noble Gas Mon OT Iodine Mon Vent Gas Mon Range Noble Gas lange Noble Gas Range Noble Gas Vent Accident Mon Range Noble Gas
-up)
Vent Accident Mon Range Noble Gas
-up)
Value of Monitor Units mR/hr mR/hr mR/hr mR/hr mR/hr R/hr R/hr cpm cpm cpm cpm uCi/cc uCi/cc uCi/cc uCi/cc uCi/cc Nuclear Common Rev. O00 Salem U it Page 36 of 39
NC.EP-EF'
.0313(Q)
TABLE 1-1 Page I of I DRYWELL LEAK RATE NOMOGRAM RELEASE RATE (UCI/SEC) ft DRYWELL LEAK RATE (X PER DAY)
L LEA RAT (X PE DAY) b5E-1 0b=+U bt+1-ntCeDtt
- r 1E-1 12+0 12+1 1E+2 1E+3 1E+4 1E+5 1E+6 DRYWELL (PRIMARY CONTAINMENT) HIGH RANGE MONITOR RESPONSE (DAPA) R/hr 100%
(2 hrs)
Whole Body Maximum Offsite Dose Rate (mRem/hr)
C B XIQ (Seclm3
%\\
0.5%
1 0%
Page 37 of 39 Rev. 00 10%
10 %
1 E+3 1 E+4-.-
-6E+4 1 E+6 -
5E+6 12+8 12E+9 52+9 1Et 12-.
-1E-3
--1E-4
-1E-5 1 E-6
--1E-7
-1E-8 1E+6 5E+5.
1 E+5.
5E+4 I Et4 1E+3 I 2+3 5E+2 1E+1 5E+0 1E+0 5E-i I E-1 5E-2_
1E-2_
-1£,
\\1 X
-\\E Nuclear Common G-
\\
\\
NC.EP-EP.ZZ-0313(Q)
TABLE 1 - 2 Page 1 of I XulQ VALUES FOR ELEVATED RELEASES AT HOPE CREEK (MULTIPLY ALL VALUES BY 1.0E-06)
STABILITY CLASS MILES METERS A
B C
D E
F G
0.06 100 47.6 9.5 103.2 1.1E-09 1.9E-18 6.4E-49 0.12 200 120.2 105.9 338.9 5.7E-01 1.1E-03 1.7E-13 5.5E-39 0.19 300 77.5 113.3 270.1 16.5 0.72 7.8E-06 4.7E-19 0.25 400 42.7 87.8 194.0 47.4 7.6 7.2E-03 4.8E-11 0.31 500 24.7 65.1 142.0 70.3 22.4 0.22 5.6E-07 0.37 600 15.3 48.9 107.5 81.2 39.3 1.5 1.3E-04 0.44 700 10.1 37.6 84.0 83.7 53.7 4.9 4.1E-03 0.50 800 7.0 29.6 67.4 81.7 63.9 10.6 0.042 0.56 (MEA) 900 5.1 23.8 55.3 77.5 70.3 18.1 0.22 0.79 1270 1.8 12.4 30.5 58.8 73.3 46.6 5.7 1.0 1609 1.1 7.8 20.1 45.6 65.3 57.9 15.0 1.5 2414 0.77 3.5 9.7 27.7 46.1 57.7 31.7 2.0 3218 0.59 2.0 5.8 18.9 34.0 49.6 37.6 2.5 4023 0.48 1.3 3.9 13.9 26.3 42.0 38.3 3.0 4827 0.41 0.89 2.8 10.8 21.2 36.0 37.1 3.5 5632 0.36 0.65 2.1 8.7 17.6 31.2 35.1 4.0 6436 0.32 0.50 1.7 7.2 14.9 27.5 33.0 4.5 7241 0.28 0.40 1.3 6.1 12.9 24.4 31.0 5.0 (LPZ) 8045 0.26 0.34 1.1 5.2 11.3 22.0 29.1 5.5 8850 0.24 0.32 0.93 4.6 10.1 19.9 27.4 6.0 9654 0.22 0.29 0.80 4.0 9.0 18.2 25.8 6.5 10459 0.20 0.27 0.69 3.6 8.2 16.7 24.4 7.0 11263 0.19 0.25 0.60 3.2 7.4 15.4 23.1 7.5 12068 0.18 1 0.24 0.53 2.9 6.8 14.3 21.9 8.0 12872 0.17 0.22 0.47 2.7 6.3 13.3 20.8 8.5 13677 0.16 0.21 0.42 2.4 5.8 12.5 19.8 9.0 14481 0.15 0.20 0.38 2.3 5.4 11.7 18.9 9.5 15286 0.14 0.19 0.35 2.1 5.1 11.1 18.1 10.0 (EPZ) 16090 0.14 0.18 0.32 1.9 4.7 10.4 17.4 15.0 24135 0.096 0.13 0.17 1.1 2.8 6.6 12.2 20.0 32180 0.074 0.098 0.13 0.72 2.0 4.8 9.4 25.0 40225 0.060 0.080 0.11 0.52 1.5 3.7 7.6 30.0 48270 0.051 0.068 0.090 0.40 1.2 3.0 6.4 35.0 56315 0.045 0.059 0.078 0.32 0.98 2.5 5.5 40.0 64360 0.040 0.053 0.069 0.27 0.83 2.2 4.8 45.0 72405 0.036 0.047 0.062 0.22 0.71 1.9 4.3 50.0 80450 0.032 0.043 0.057 0.19 0.63 1.7 3.9 HOPE CREEK ELEVATED RELEASES Nuclear Common Rev. 00 Page 38 of 39
NC.EP-EP.ZZ-0313(Q)
TABLE 1 - 3 Page 1 of 1 XulQ VALUES FOR GROUND RELEASES AT HOPE CREEK (MULTIPLY ALL VALUES BY 1.OE-06)
STABILITY CLASS MILES METERS A
B C
D E
F G
0.06 100 351.2 417.0 473.7 517.9 534.9 546.9 552.3 0.12 200 174.6 257.9 344.4 439.8 488.7 525.1 542.6 0.19 300 83.0 159.0 243.5 361.4 435.8 497.1 529.3 0.25 400 43.0 103.6 175.7 295.1 384.3 466.0 513.3 0.31 500 24.6 71.5 131.0 242.5 337.6 433.8 495.5 0.37 600 15.2 51.8 100.8 201.5 296.7 402.2 476.4 0.44 700 10.1 39.0 79.7 169.4 261.6 371.9 456.7 0.50 800 7.0 30.4 64.5 144.2 231.7 343.5 436.7 0.56 (MEA) 900 5.0 24.2 53.3 124.2 206.3 317.1 416.7 0.79 1270 1.8 12.5 29.9 78.4 140.4 237.6 346.3 1.0 1609 1.1 7.9 19.8 56.3 104.8 189.0 296.6 1.5 2414 0.77 3.5 9.7 31.5 62.1 122.5 216.1 2.0 3218 0.59 2.0 5.8 20.7 42.4 88.1 166.9 2.5 4023 0.48 1.3 3.9 15.0 31.5 67.7 134.6 3.0 4827 0.41 0.89 2.8 11.4 24.7 54.4 112.1 3.5 5632 0.36 0.65 2.1 9.1 20.1 45.1 95.6 4.0 6436 0.32 0.50 1.7 7.5 16.9 38.3 83.1 4.5 7241 0.28 0.40 1.3 6.3 14.4 33.2 73.3 5.0 (LPZ) 8045 0.26 0.34 1.1 5.4 12.5 29.2 65.4 5.5 8850 0.24 0.32 0.93 4.7 11.0 26.0 59.0 6.0 9654 0.22 0.29 0.80 4.2 9.8 23.4 53.7 6.5 10459 0.20 0.27 0.69 3.7 8.9 21.2 49.2 7.0 11263 0.19 0.25 0.60 3.3 8.0 19.4 45.3 7.5 12068 0.18 0.24 0.53 3.0 7.3 17.8 42.0 8.0 12872 0.17 0.22 0.47 2.7 6.7 16.5 39.2 8.5 13677 0.16 0.21 0.42 2.5 6.2 15.3 36.6 9.0 14481 0.15 0.20 0.38 2.3 5.8 14.3 34.4 9.5 15286 0.14 0.19 0.35 2.1 5.4 13.3 32.4 10.0 (EPZ) 16090 0.14 0.18 0.32 2.0 5.0 12.5 30.6 15.0 24135 0.096 0.13 0.17 1.1 3.0 7.7 19.5 20.0 32180 0.074 0.098 0.13 0.72 2.1 5.4 14.2 25.0 40225 0.060 0.080 0.11 0.52 1.5 4.2 11.1 30.0 48270 0.051 0.068 0.090 0.40 1.2 3.3 9.1 35.0 56315 0.045 0.059 0.078 0.32 1.0 2.8 7.7 40.0 64360 0.040 0.053 0.069 0.27 0.8 2.4 6.7 45.0 72405 0.036 0.047 0.062 0.23 0.7 2.1 5.9 50.0 80450 0.032 0.043 0.057 0.19 0.6 1.8 5.2 HOPE CREEK GROUND RELEASES Nuclear Common Page 39 of 39 Rev. 00