AmerGen An Exelon/British Energy Company AmerGen Energy Company, LLC Oyster Creek US Route 9 South P.O. Box 388 Forked River, NJ 08731-0388 10 CFR 20.2206 April 30, 2002 2130-02-20016 United States Nuclear Regulatory Commission Document Control Desk Washington DC 20555

Subject:

Oyster Creek Generating Station Docket 50-219; Operating License DPR - 16 Occupational Radiation Exposure Data Report Enclosed with this cover is the year 2001 Occupational Exposure Data Report for the Oyster Creek Generating Station. This information is being submitted in electronic format as described in Regulatory Guide 8.7. The electronic data is enclosed as follows:

PC Diskette:

File Name:

Technical

Contact:

Instruction:

3.5 inch double sided, high density, standard IBM DOS format, In ASCII text characters OC2001.txt 3/29/2002 WinNT 4.0 Robert A. Heffner 609.971.4496 rheffner@amergenenergy.com All data is contained in one file Also enclosed is the Oyster Creek Generating Station tabulation of station, utility, and other personnel for whom monitoring is required. This requirement addresses personnel receiving exposures of greater than 100 mrem/yr and their associated man-rem exposure sorted by work and job function. The dose assessment to various duty functions were estimated. In the aggregate, at least 80% of the total whole body dose received from external sources was included in major work functions, as delineated in the Oyster Creek Technical Specifications.

2130-02-20016 Page 2 If any further information or assistance is required, please contact Mr. John Rogers of my staff at 609.971.4893.

Very truly yours, Ron J. DeGregorio, Vice President Oyster Creek Generating Station RJD/JJR.

Enclosure cc:

Administrator, Region I NRC Senior Project Manager NRC Senior Resident Inspector C. S. Hinson, NRR Radiation Protection Branch REIRS NRR Project Manager

AMERGEN CORPORATION OYSTER CREEK NUCLEAR GENERATING STATION FORKED RIVER, N.J. 08731 LICENSE NOS. DPR-16 STANDARD FORMAT FOR REPORTING NUMBER OF PERSONNEL AND MAN-REM BY WORK AND JOB FUNCTION FOR THE PERIOD 01/01/01 THROUGH 12/31/01 WORK FUNCTION Job Function REACTOR OPS AND SURVEILLANCE Maintenance Personnel Operating Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel ROUTINE MAINTENANCE Maintenance Personnel Operating Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel INSERVICE INSPECTION Maintenance Personnel Operating Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel SPECIAL MAINTENANCE Maintenance Personnel Operating Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel WASTE PROCESSING Maintenance Personnel Operating Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel REFUELING Maintenance Personnel Operating Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel NUMBER OF INDIVIDUALS Maintenance Personnel Operating Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel TOTAL INDIVIDUALS NUMBER OF PERSONS WITH MONITORED EXPOSURE (Derived form RWP DATA)

Station Utility Employees Employees 68 95 75 66 49 101 27 36 54 19 0

0 0

0 0

44 11 18 18 3

15 47 25 12 1

3 2

180 122 87 227 113 729 12 2

1 6

1 43 0

0 8

1 0

0 0

0 0 16 0

0 3

0 8

0 0

2 0

15 0

0 5

0 88 6

1 79 31 205 Contractors and Others 9

7 1

108 5

31 0

2 97 2

0 0

0 0

0 11 0

0 37 0

2 0

6 22 1

4 0

0 2

0 95 9

11 478 13 606 TOTAL MAN-REM(est)

(Derived from RWP DATA)

Station Employees 2.642 5.588 3.557 0.393 0.157 12.088 0.576 1.251 3.402 0.221 0.000 0.000 0.000 0.000 0.000 1.026 0.263 0.457 0.260 0.009 0.066 0.839 0.879 0.483 0.005 0.001 0.001 0.053 0.021 0.003 15.823 7.267 6.197 4.559 0.395 34.241 NOTE: Thermoluminescent Dosimeter (TLD) Whole Body Actual Dose For The Period Is 45.780 Rem Utility Employees 0.034 0.033 0.000 0.022 0,005 Contractors and Others 0.068 0.000 0.001 0.413 0.004 0.584 0.000 0.000 0.191 0.005 0.000 0.000 0.000 0.000 0.000 0.319 0.000 0.000 0.067 0.000 0.265 0.000 0.000 0.024 0.005 0.416 0.000 0.000 0.114 0.000 1.618 0.033 0.000 0,418 0.015 2.084 1.495 0.000 0.083 5.004 0.015 0.000 0.000 0.000 0.000 0.000 0.142 0,000 0.000 0.219 0.000 0.130 0.000 0.341 2.249 0.000 0.136 0.000 0.000 0.032 0.000 1.971 0.000 0.425 7.917 0.019 10.332