George, Dave, Paul:

Our reviewer, Timothy Steingass, has the following comments on your 9/14/01 submittal:

Page 5 of 6 says that you performed a VIPER code analysis for axial weld failure probability to assess the effect of fracture due to the 57% inspection coverage on the vessel axial welds.

Your result was a 2.5E-12/year failure probability due to the 57% beltline examination coverage.

In reading the safety evaluation to the BWRVIP-05 report, Tim finds this to be substantially lower than the BWR fleet failure probability limit of 5E-6 per reactor-year to assure vessel integrity.

(1) Were your calculations based on 114 degrees F or 70 degrees F mean RTNDT ?

2) Why is your Vessel Failure Probability six times an order of magnitude lower than the BWR fleet?
3) What are your values for Conditional Failure Probability and Low Temperature Overpressure Frequency?

These comments are provided to prepare you for a phone call. This e-mail does not formally request additional information, and does not convey a formal NRC staff position. Disposition of these comments will be discussed in the phone call.

Peter S. Tam, Senior Project Manager Project Directorate I-1 Division of Licensing Project Management Office of Nuclear Reactor Regulation e-mail: pst@nrc.gov Tel.: 301-415-1451 Mail Envelope Properties (3CCEB203.501 : 10 : 20510)

Subject:

Oyster Creek - Relief Request R17, Rev. 1 (TAC MB2940)

Creation Date:

4/30/02 11:02AM From:

Peter Tam Created By:

PST@nrc.gov Recipients Action Date & Time David Transferred 04/30/02 11:02AM distel (INTernet:David.distel@exeloncorp.

george Transferred 04/30/02 11:02AM rombold (INTernet:george.rombold@exelonco paul Transferred 04/30/02 11:02AM czaya (internet:paul.czaya@exelon.com) nrc.gov owf2_po.OWFN_DO Delivered 04/30/02 11:02AM TXS3 (Timothy Steingass)

Opened 04/30/02 11:03AM Post Office Delivered Route David INTernet:exeloncorp.

com george INTernet:exeloncorp.

com paul internet:exeloncorp.c om owf2_po.OWFN_DO 04/30/02 11:02AM nrc.gov Files Size Date & Time MESSAGE 2457 04/30/02 11:02AM Options Auto Delete:

No Expiration Date:

None Notify Recipients:

Yes Priority:

Standard Reply Requested:

No Return Notification:

None Concealed

Subject:

No Security:

Standard To Be Delivered:

Immediate Status Tracking:

Delivered & Opened DISTRIBUTION:

PUBLIC PDI-1 R/F PTam Accession Number: ML021210243 OFFICIAL RECORD COPY