Arkansas Nuclear One - Administrative Services Document Control Friday, April 12, 2002 Document Update Notification 103 NRC - WASHINGTON ADDRESS:

DOCUMENT NO:

TITLE:

REVISION NO:

CHANGE NO:

SUBJECT.-

OS-DOC CNTRL DESK MAIL STOP OP1 17 WASHINGTON DC 20555-DC OP-1903.011 EMERGENCY RESPONSE/

NOTIFICATIONS 026-04-0 PC-04 PERMANENT CHANGE (PC) checked, please sign, date, and return within 5 days.

jJ D ANO-I Docket 50-313 5

ANO-2 Docket 50-368 Signature Date SIGNATURE CONFIRMS UPDATE HAS BEEN MADE RETURN TO:

ATTN: DOCUMENT CONTROL ARKANSAS NUCLEAR ONE 1448 SR 333 RUSSELLVILLE, AR 72801 COPYHOLDER NO:

TO:

Fp(DL

ENTERGY OPERATIONS INCORPORATED ARKANSAS NUCLEAR ONE TITLE: Emergency Response/Notifications DOCUMENT NO.

CHANGE NO.

1903.011 026-04-0 WORK PLAN EXP. DATE TC EXP. DATE n/a n/a SET#

J-0*

SAFETY-RELATED IPTE (DYES

[:]NO

[)-YES ONO TEMP ALT

[]YES 3NO0 When you see these TRAPS Get these TOOLS Time Pressure Effective Communication Distraction/Interruption Questioning Attitude Multiple Tasks Placekeeping Overconfidence Self Check Vague or Interpretive Guidance Peer Check First Shift/Last Shift Knowledge Peer Pressure Procedures Change/Off Normal Job Briefing Physical Environment Coaching Mental Stress (Home or Work)

Turnover VERIFIED BY DATE TIME FORM TITLE:

FORM NO.

CHANGE NO.

VERIFICATION COVER SHEET.

1000.006A 050-00-0

ENTERGY OPERATIONS INCORPORATED ARKANSAS NUCLEAR ONE Paae 1 TITLE:EMERGENCY RESPONSE/NOTIFICATIONS DOCUMENT NO.

CHANGE No.

1903.011 Q26411 AFFECTED UNIT:

PROCEDURE ELECTRONIC DOCUMENT SAFETY-RELATED U UýNIT 2 ýE WORK PLAN, EXP. DATE n/a YES

[3 NO TYPE OF CHANGE:

PC TC DELETION nl NEW E] REVISION E3 EZ EXP. DATE: n/a DOES THIS DOCUMENT:

1. Supersede or replace another procedure?

YES NO (If YES, complete 1000.006B for deleted procedure.) (0CAN058107)

2.

Alter or delete an existing regulatory commitment?

(If YES, coordinate with Licensing before implementing.) (0CNA128509)(0CAN04 9 8 0 3)

E N

3.

Require a 50.59 review per LI-101? (See also 1000.006, Attachment 15) 0 YES C1 NO (If 50.59 evaluation, OSRC review required.)

4.

Cause the MTCL to be untrue? (See Step 8.5 for details.)

D YES 0

NO (If YES, complete 1000.009A) (1CAN108904, 0CAN099001, 0CNA128509, OCAN049803)

5.

Create an Intent Change?

DYES ENO (If YES, Standard Approval Process required.)

6.

Implement or change IPTE requirements?

DYES NO (If YES, complete 1000.143A. OSRC review required.)

7.

Implement or change a Temporary Alteration?

DYES ONO (If YES, then OSRC review required.)

Was the Master Electronic File used as the source document?

0YES DNO INTERIM APPROVAL PROCESS STANDARD APPROVAL PROCESS ORIG145%INAOR SIGNATURE: (incue reiwe t.1)DT:

OIIAO IGNATURE- (Inic',ludes review of Aft. 13) DATE 4 fO Print and Si n name:i PHONE #:

Pri nTandi Sign name: Duane White PHONE i: 4997 SUPERVISOR APPROVAL:*

DATE:

IN ENT IEWER:

DATE:

Al

)A' I

XI

  • DATE:

SRO UNIT ONE :"

DATE:

ENGINEERING:

f 4 AP(4 "SRO UNIT TWO:**

DATE:

QUALITY:

DATE:

Interim approval allowed for non-intent changes requiring no UNIT SURVEILLANCE COORDINATOR (0CNA049803): DATE:

50.59 evaluation that are stopping work in progress.

A I

S*

ON EADEJt*.:DATE:

Standard Approval required for intent changes or changes ON LEADE DE requiring a 50.59 evaluation.

DATE:

  • If change not required to support work in progress, QUALITY ASSURANCE:

DATE:

Department Head must sign.

DATE:

    • If both units are affected by change, both SRO signatures OTHER SECTION LEADERS:

DATE are required. (SRO signature required for safety related Il/1 procedures only.)

OTHER SECTION LEADERS:

DATE:

ENTERGY OPERATIONS INCORPORATED ARKANSAS NUCLEAR ONE d

C c

I 5ection 3.4 ^uuu escription of ommitment and orrected step eferences.

from Form 1903.011Y to NRC using ENS & requIre to OW...

after initial ENS notification.

Form 1903.011BB steps 7 and 8 and Form 1903.011CC steps 7 and 8.

3.4.2 OCAN068104 (P-10936)

Incorporate all applicable emergency call list into one notification procedure for the SAA to use during emergencies.

Forms 1903.011BB and 1903.011CC 3.4.3 TELCONDWB910 0 6 (P-1735) -

Revise and/or develop procedures ensure ERDS is activated upon an Alert or higher emergency class.

Section 6.4, 1903.011BB Step 9 and 1903.011CC Step 6.

3.4.5 0CAN068503 (P-4584) -

Include requirement for NRC notification immediately after state notification in Procedure 1903.010 and Emergency Plan, Rev.

1. Form 1903.011BB Note page 4 of 5 and Form 1903.011CC Note page 3 of 4.

3.4.7 2CAN047912 (P-7706) - Ensure prompt notification of the NRC.

Form 1903.011BB Step 7 and Form 1903.011CC Step 7.

3.4.8 OCAN058411 (P-9461) - Procedure 1903.011 will be revised to require an approval signature by authorized individual.

Procedure 1903.011Y step 3 3.4.13 0CAN068320 (P-10758) -

EPIP 1903,011 contains follow-up message.

Form 1903.011Z.

3.4.14 OCAN059701 (P-15456) -

Emergency Response/Notifications procedure emphasizes the Shift Superintendent review of the plant evacuation checklist.

Procedure 1903.011(J,M,P,S) Step 5 and 1903.011Y Step 3 3.4.15 0CAN09820 6 (P-9466) - Provide adequate assurance of prompt response time under normal circumstances.

1903.011BB step 5, 1903.011CC steps 5 3.4.17 OCAN108213 (P-10823) -

Provide adequate assurance of prompt response time.

Form 1903.011BB Step 5 and 1903.011CC Step 5.

FORM TITLE:

DESCRIPTION OF CHANGE 1000.006C 050-00-0 TITLE:Emergency Response/Notifications UMENT NO.

CHANGE NO.

19g03.01 1 026-04-0 ZPROCEDURE O-WORK PLAN, EXP. DATE n/a PAGE 1 OF__?=.._

El ELECTRONIC DOCUMENT TYPE OF CHANGE:

nl NEW E PC El TC DELETION E1 REVISION El EZ EXP. DATE:_ n/a AFFECTED SECTION:

DESCRIPTION OF CHANGE: (For each change made, include sufficient detail to describe (Include step # if reason for the change.)

applicable)

^*^*

3.4.1 OCAN039701 (P-15339) - Require verbatim transmission of info to

I FORM TITLE:

FORM NO.

CHANGE NO.

F DESCRIPTION OF CHANGE 1000.006C 050-00-0 ENTERGY OPERATIONS INCORPORATED ARKANSAS NUCLEAR ONE TITLE:Emergency RessDOCUMENT NO.

CHANGE NO.

yResponseNOtifications 1903.011 026-04-0

[PROCEDURE

'WORK PLAN, EXP. DATE n/a PAGE 2 OF-2

[I ELECTRONIC DOCUMENT TYPE OF CHANGE:

PT DELETION El NEW PC TC El REVISION E] EZ EXP. DATE:_ n/a AFFECTED SECTION:

DESCRIPTION OF CHANGE: (For each change made, include sufficient detail to describe (Include step # if reason for the change.)

applicable)

Form 1903.011Y Added "There [I is l jsnot a radioactive gaseous or liquid release taking place at this time due to this event."

Form 1903.011BB, Changed step 2 to the following:

Step 2 Place 1903.01 1Y face down in DEFNS fax document tray Press RED speed dial button.

Press RED fax button.

Time:

Date:_

IF:

"* You are the EOF Notifications Communicator AND

"* The ADH is collocated with ANO AND

"* The EOF Director has ED&C, THE. N perform the following:

a. Give the notifications forms to the State TOCD directly.
b. Go to step 5.

Formn 1903.011 CC, Changed step 2 to the following:

Step 2 Place 1903.011 Z facedown in DEFNS document tray Press RED speed dial button.

Press RED fax button.

Time:

Date:_

IF:

  • You are the EOF Notifications Communicator AND
  • The ADH is collocated with ANO AND
  • The EOF Director has ED&C, THEN Give the notifications forms to the State TOCD directly.

FROM:

ADMIN LIBRARY FAX NO.:

479 858 4791 04-23-02 02:9SP P.02 PROCJWORK PLAN NO.

PROCEDURE/WORK PLAN TITLE:

PAGE:

1 of 74 1903.011 EMERGENCY RESPONSEINOTIFICATIONS CHANGE:

026-04-0 TABLE OF CONTENTS Page I of 2 SECTIONS PAGE NO.

1.0 Pu rp os e.............................................................

a.0 scope..............................................................

3 3.0 References..........................................................

3 4,0 Definitions.........................................................

5 S.0 Responsibility And Authority........................................

7 6.0 Instruction.........................................................

8 6.1 Emergency Classification And NotificaCions 8

6.2 Protective Action Recommendations (PARs) 8 6.3 Courtesy Calls.............................................

9 6.4 Non-Emergency/Off-Normal Events.............................

9 6.5 Emergency Response Data System (RRDS).......................

10 7.0 Attachments And Forms...............................................

11 7.1 - Notification of Unusual Event...............

12 7.2 - Alert.......................................

IS 7.3 - Site Area Emergency.........................

18 7.4 - General Emergency.............................

27 7.5 - Alternate ERO Notification Scheme...........

51 7.6 - Protective Action Recommendations (PAR) for General Emergency..........................................

5 2 7.7 -

Core Puel Damage Assessment, Unit 1.........

56

'.a Attachment a -

Core Fuel Damage Assessment, Unit 2.........

60 7.9 Atcachment 9 - Computerized Notification System (CNS)

Instructions.

64 7,10 0 -

Emergency Class Notification Inatructions.. 71 7.11 1 -

Non-Emergency Notifications of Off-Normal bvents.

74 7.12 Form 1903.011J -

NUB Emerqency Direction and Control Checklist..................................................

13 7.23 Form 1903.O11M - Alert Emergency Direction and Control Checklist.

16 "7.14 Form 1903.011P -

SAE Emergency Direction and Control Checklist, Shift Manager...................................

19 7.15 Form 1903.011Q -

SAE Emergency Direction and control Checklist, TSC Director....................................

23 7.16 Form 1903.011R -

SAE Emergency Direction and Control Checklist, EOF Director....................................

26 7.17 Form 1903.011S -

GE Emergency Direction and Control Checklist, Shift Manager....................................

28 7.18 Form 1903.011T - GE Emergcncy Dircction and Control Checklist, TSC Director....................................

32

PROCJWORK PLAN NO.

1903.011 PROCEDUREMWORK PLAN TITLE:

EMERGENCY RESPONSE/NOTIFICATIONS TABLE OF CONTENTS Page 2 of 2 SECTIONS PAGE NO.

7.19 Form 1903.011U -

GE Emergency Direction and Control Checklist, EOF Director....................................

35 7.20 Form 1903.011Y -

Emergency Class Initial Notification Message....................................................

37 7.21 Form 1903.011Z -

Emergency Class Follow-up Notification Message....................................................

38 7.22 Form 1903.011AA -

Courtesy Call Notification Message.......

39 7.23 Form 1903.011BB -

Initial Notification Checklist...........

40 7.24 Form 1903.011CC -

Follow-up Notification Checklist.........

45 7.25 Form 1903.011DD -

Courtesy Call Notification Checklist..... 49 PAGE:

2 of 74 CHANGE:

026-04-0

PROC.IWORK PLAN NO.

PROCEDURE IWORK PLAN TITLE:

026:3of7 1903.011 EMERGENCY RESPONSEINOTIFICATIONS CHANGE:

0040 PROJWOK PAN O.

ROCDUR/WOK PAN ITL:HANGE:

3026-74 1.0 PURPOSE This procedure establishes required emergency response actions for each of the four Emergency Classes.

The required actions described in this procedure are for purposes of notification to offsite authorities and activation/response of appropriate portions of ANO's Emergency Response Organization.

2.0 SCOPE This procedure is applicable to Units 1 and 2 in all modes: It does not include specific plant casualty procedures or systems operations requirements, but rather provides administrative processes only.

This procedure describes actions for events that meet the criteria for Emergency Classes and Courtesy Calls.

3.0 REFERENCES

3.1 REFERENCES

USED IN PROCEDURE PREPARATION:

3.1.1 ANO Emergency Plan 3.1.2 ANO EAL Bases Document 3.1.3 NUREG-0654/FEMA-REP-1, Rev.

1 3.1.4 10 CFR 50 3.1.5 IE Information Notice No. 83-28: Criteria for Protective Action Recommendations for General Emergencies 3.1.6 U.S.

NRC, Response Technical Manual (RTM-93)

Volume 1 Revision 3.

3.1.7 Memorandum ANO-98-00352,

Subject:

ADH Courtesy Call Agreement.

3.2 REFERENCES

USED IN CONJUNCTION WITH THIS PROCEDURE:

3.2.1 Station Directive A6.202, "Public Communications" 3.2.2 1000.104, "Condition Reporting Operability and Immediate Reportability Determinations" 3.2.3 1015.007, "Fire Brigade Organization and Responsibilities" 3.2.4 1043.042, "Response to Contingency" 3.2.5 1903.010, "Emergency Action Level Classifications" 3.2.6 1903.030, "Evacuation" 3.2.7 1903.042, "Duties of the Emergency Medical Team" 3.2.8 1903.043, "Duties of.the Emergency Radiation Team" 3.2.9 1903.064, "Emergency Response Facility - Control Room"

3.3 3.2.13 ANO Security Plan/Seur*+/- y

.....r 3.2.14 1604.015, "Analysis of Unit Vents" 3.2.15 1604.017, "Analysis of Liquid Waste" RELATED ANO PROCEDURES:

None REGULATORY CORRESPONDENCE CONTAINING NRC COMMITMENTS WHICH ARE IMPLEMENTED IN THIS PROCEDURE INCLUDE:

[BOLD]

DENOTES COMMITMENTS 3.4.1 0CAN039701 (P-15339)

- Require verbatim transmission of info from Form 1903.011Y to NRC using ENS & require follow up fax to NRC after initial ENS notification.

Form 1903.011BB steps 7 and 8 and Form 1903.011CC steps 7 and 8.

3.4.2 0CAN068104 (P-10936)

- Incorporate all applicable emergency call list into one notification procedure for the SAA to use during emergencies.

Forms 1903.011BB and 1903.011CC 3.4.3 TELCONDWB9100 6

(P-1735)

- Revise and/or develop procedures to ensure ERDS is activated upon an Alert or higher emergency class.

Section 6.5, 1903.011BB Step 9 and 1903.011CC Step 6.

3.4.4 0CAN089209 (P-3335) 1903.011 Attachment 9 3.4.5 0CAN068503 (P-4584)

Include requirement for NRC notification immediately after state notification in Procedure 1903.010 and Emergency Plan, Rev. 1. Form 1903.011BB Note page 4 of 5 and Form 1903.011CC Note page 3 of 4.

3.4.6 1CAN047910 (P-7596) section 6.3.2 3.4.7 2CAN047912 (P-7706)

- Ensure prompt notification of the NRC.

Form 1903.011BB Step 7 and Form 1903.011CC Step 7.

3.4.8 0CAN058411 (P-9461)

Procedure 1903.011 will be revised to require an approval signature by authorized individual.

Procedure 1903.011Y step 3 3.4.9 0CAN118307 (P-9875) section 6.2 3.4.10 0CAN068320 (P-10766) section 6.2 3.4.11 0CAN128012 (P-10455) 1903.011 Attachment 9 3.4.12 0CNA108215 (P-10847) 1903.011 Attachment 9 3.4.13 0CAN068320 (P-10758)

EPIP 1903.011 contains follow-up message.

Form 1903.011Z.

3.4.14 OCANOS9701 (P-15456)

- Emergency Response/Notifications procedure emphasizes the Shift Superintendent review of the 3.4 PROC.IWORK PLAN NO.

PROCEDUREIWORK PLAN TITLE:

PAGE:

4 of 74 1903.011 EMERGENCY RESPONSEINOTIFICATIONS CHANGE:

026-04-0 3.2.10 1903.065, "Emergency Response Facility

- Technical Support Center (TSC)I" 3.2.11 1903.066, "Emergency Response Facility

- Operational Support Center (OSC) "

3.2.12 1903.067, "Emergency Response Facility Emergency Operations Facility"

PROC.JWORK PLAN NO.

PROCEDUREIWORK PLAN TITLE:

PAGE:

of 74 1903.011 EMERGENCY RESPONSEINOTIFICATIONS P

5f CHANGE:

026-04-0 plant evacuation checklist.

Procedure 1903.011(J,M,P;S)

Step 5 and 1903.011Y Step 3 3.4.15 0CAN098206 (P-9466)

- Provide adequate assurance of prompt response time under normal circumstances.

1903.011BB step 5,

1903.011CC steps 5 3.4.16 1CAN088308 (P-9589) 1903.011 Attachment 1 3.4.17 0CAN108213 (P-10823)

- Provide adequate assurance of prompt response time.

Form 1903.011BB Step 5 and 1903.011CC ýtep

5.

4.0 DEFINITIONS 4.1 Alert Events are in progress or have occurred which involve an actual or potential substantial degradation of the level of safety of the plant.

Any releases are expected to be limited to small fractions of the EPA Protective Action Guideline exposure levels.

4.2 Courtesy Call -

A notification to the Arkansas Department of Health and follow-up notification to the NRC for conditions/events other than those constituting an Emergency Class as listed in procedure 1903.011, "Emergency Response/Notifications",

Section 6.3.

4.3 Emergency Action Level -

A plant or onsite condition which has exceeded pre-determined limits which would categorize the situation into one of the following four Emergency Classes:

Notification of Unusual Event Alert Site Area Emergency General Emergency 4.4 Emergency Direction and Control - Overall direction of facility response which must include the non-delegable responsibilities for the decision to notify and to recommend protective actions to Arkansas Department of Health personnel and other authorities responsible for offsite emergency measures.

With activation of the EOF, the EOF Director typically assumes the responsibility for Emergency Direction and Control.

The management of on-site facility activities to mitigate accident consequences remains with the TSC Director in the Technical Support Center.

The Shift Manager retains responsibility for the Control Room and plant systems operation.

4.5 Emergency Operations Facility (EOF)

A near-site emergency response facility located approximately 0.65 miles northeast of the reactor buildings (the ANO Training Center).

4.6 Emergency Planning Zone (EPZ)

The EPZ considered by this procedure is the inhalation zone, that area within approximately a 10-mile radius of ANO.

PROC.NJORK PLAN NO.

PROCEDUREFWORK PLAN TITLE:

PAGE:

6 of 74 1903.011 EMERGENCY RESPONSEINOTIFICATIONS CHANGE:

026-04-0 4.7 Emergency Response Data System (ERDS)

A channel over which the raw reactor parametric data, i.e., SPDS information, is transmitted from the site to the NRC Operations Center (NRCOC).

This system is activated from the RDACS terminal located in either Control Room or in the Technical Support Center and should be activated within one hour of an ALERT or higher emergency class declaration.

4.8 Emergency Response Organization (ERO)

- The organization which is composed of the Initial Response Staff (IRS),

the EOF staff, the TSC staff, the OSC staff, and the Emergency Team members.

It has the capability to provide manpower and other resources necessary for immediate and long-term response to an emergency situation.

4.9 Evacuation Routes - Routes used by ANO personnel that may be used to exit the plant site in the event of a plant or exclusion area evacuation, defined as follows:

4.9.1 Evacuation Route 1 - From the main guard station, proceed East along the intake canal to May Road, then North to State Road 333.

4.9.2 Evacuation Route 2 -

From the main guard station, proceed West, then North past the cooling tower and then sally port, using the North access road to State Road 333.

4.9.3 Evacuation Route 3 - From the main guard station, proceed West, then continue West along the West access road to Flatwood Road, and continue on Flatwood Road North to State Road 333.

4.10 General Emergency - Events are in progress or have occurred which involve actual or imminent substantial core degradation or melting with the potential for loss of containment integrity.

Releases can be reasonably expected to exceed EPA Protective Action Guideline exposure levels off site for more than the immediate site area.

4.11 Initial Response Staff (IRS)

- The emergency organization primarily composed of plant personnel which must be able to augment the onsite plant personnel in accordance with Table B-1 of the Emergency Plan.

4.12 Offsite - Those areas outside the Exclusion Area boundary.

4.13 Offsite Release - For purposes related to the Emergency Plan, an offsite release will be defined as a release due to the event which exceeds the ODCM release limits.

4.14 Onsite - The area within the Exclusion Area Boundary.

4.15 Operational Support Center - Emergency response center within the ANO maintenance facility where support is coordinated for the following functions: Onsite Radiological Monitoring, Maintenance, Nuclear Chemistry, Emergency Medical Support and Fire Fighting Support.

The OSC serves as the assembly point and briefing area for recovery/reentry teams and is located in the maintenance facility.

PROCJWORK PLAN NO.

PROCEDUREfWORK PLAN TITLE:

PAGE:

7 of 74 1903.011 EMERGENCY RESPONSEINOTIFICATIONS CHANGE:

026-04-0 4.16 Notification of Unusual Event - Unusual events are in progress or have occurred which indicate a potential degradation of the level of safety of the plant.

No releases of radioactive material requiring offsite response or monitoring are expected unless further degradation of safety systems occurs.

4.17 REAM (Radiological/Environmental Assessment Manager)

- Responsible for managing radiological dose assessment and field monitoring activities.

Provides offsite Protective Action Recommendations (PAR) to the EOF Director.

Coordinates the ANO offsite radiological monitoring effort with the Arkansas Department of Health (ADH) and the NRC.

The EOF HP Supervisor and the Dose Assessment Supervisor report to the REAM.

4.18 Site Area Emergency - Events are in progress or have occurred which involve actual or likely major failures of plant functions needed for protection of the public.

Any releases are not expected to exceed EPA Protective Action Guideline exposure levels except near the site boundary.

4.19 Technical Support Center - The location within the ANO Plant Administration Building equipped with instrumentation and communication systems and facilities useful in monitoring the course of an accident.

5.0 RESPONSIBILITY AND AUTHORITY 5.1 SHIFT MANAGER Has responsibility for implementation of response actions described in this procedure until relieved by the Technical Support Center Director or Emergency Operations Facility Director.

5.2 TECHNICAL SUPPORT CENTER DIRECTOR (TSC DIRECTOR)

Upon assumption of responsibility for Emergency Direction and Control the TSC Director is responsible for implementation of the response actions described in this procedure.

5.3 EMERGENCY OPERATIONS FACILITY DIRECTOR (EOF DIRECTOR)

Upon assumption of responsibility for Emergency Direction and Control the Emergency Operations Facility Director is responsible for implementation of the response actions described in this procedure.

5.4 COMMUNICATORS Communicators are responsible for performing emergency response notifications/communications.

5.5 EMERGENCY RESPONSE ORGANIZATION (ERO)

Members of the ERO are responsible to ensure completion of notifications as denoted on Attachment 5,

,' Alternate ERO Notification Scheme" if the ERO cannot be activated by the Computerized Notification System.

PROC.IWORK PLAN NO.

PROCEDUREIWORK PLAN TITLE:

PAGE:

8 of 74 1903.011 EMERGENCY RESPONSE/NOTIFICATIONS CHANGE:

026-04-0 6.0 INSTRUCTIONS 6.1 EMERGENCY CLASSIFICATION AND NOTIFICATIONS 6.1.1 Implement the appropriate sections of this procedure whenever an emergency classification has been declared, escalated, or de-escalated as per 1903.010, "Emergency Action Level Classifications".

A.

Notification of Unusual Event, perform the actions as described in Attachment 1.

B.

Alert, perform the actions as described in.

C.

Site Area Emergency, perform the actions as described in Attachment 3.

D.

General Emergency, perform the actions as described in.

6.1.2 At the termination of the event, provide summaries to the Nuclear Regulatory Commission (NRC) and Arkansas Department of Health (ADH).

Notify both parties of the event termination using Form 1903.011Y.

6.2

[PROTECTIVE ACTION RECOMMENDATIONS (PARs) 6.2.1 The Shift Manager shall be responsible for issuing PARs to offsite authorities until relieved of Emergency Direction and Control by the TSC Director/EOF Director.

The Shift Manager should rely on Nuclear Chemistry for the formulation of PARs based on radiological conditions and the Operations staff for the formulation of PARs based on plant conditions.

6.2.2 The TSC Director, after assuming Emergency Direction and Control, is responsible for issuing PARs to offsite authorities until relieved by the EOF Director.

The TSC Director should rely on the REAM for the formulation of PARs based on radiological conditions and the Operations/TSC staffs for the formulation of PARs based on plant conditions.

6.2.3 The EOF Director, after assuming Emergency Direction and Control, is responsible for issuing PARs to offsite authorities.

The EOF Director should rely on the REAM for the formulation of PARs based on radiological conditions and the TSC Director for the formulation of PARs based on plant conditions.]

PROC.WORK PLAN NO.

PROCEDUREJWORK PLAN TITLE:

PG:

9 of 74 1903.011 EMERGENCY RESPONSEINOTIFICATIONS CHANGE:

026-04-0 6.3 COURTESY CALLS 6.3.1 ANO has agreed to notify the STATE OF ARKANSAS for the following non-Emergency Class events:

A.

An UNPLANNED release of radioactive material has occurred OR may occur.

(Refer to procedures 1604.015 or 1604.01-7 for definition of "unplanned release".)

B.

An UNPLANNED reactor trip from power has occurred.

C.

An event has occurred for which a news release is planned (refer to Station Directive A6.202, "Public Communications", ). Potential Public Interest events, which will not require a news release, do not require a Courtesy Call (excluding Steps A and B--bove).

The on-call EOF Director and Communications Manager should decide upon the initiation of a news release and inform the Shift Manager.

D.

A notification has been made OR will be made to other government agencies for events that have impacted OR will impact the public health and safety.

6.3.2 A Courtesy Call should be made as soon as practicable following the event but no later than 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> following the event.

6.3.3 Notification to the NRC Operations Center shall be performed no later than 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> following the event.

6.3.4 Complete Form 1903.011DD, "Courtesy Call Notification Checklist".

Proceed to section 6.4 upon completion of checklist.

6.4 NON-EMERGENCY OFF-NORMAL EVENT NOTIFICATIONS 6.4.1 IF the off-normal event does not require an emergency class declaration, THEN an "Information Only" notification to the following may be warranted:

Designated Entergy Management Representatives NRC Resident Inspector Arkansas Department of Health (in some cases) 6.4.2 A non-emergency off normal event notification should be performed if any of the following conditions exits:

A.

A Courtesy Call is required per the above section.

[B.

An NRC Reportable Non-Emergency Event has occurred NRC Reportable Non-Emergency Event are events which.

are reportable in accordance with IOCFR50.72 but which do NOT meet the criteria for emergency class (6.4.2 con't.)

declaration as delineated in Procedure 1903.010,

"-Emergency Action Level Classification."

The "information only" notification described in this section is supplemental to the immediate notification required by regulations which are determined in accordance with Procedure 1000.104, nCondition Reporting Operability and Immediate Reportability Determinations."]

C.

Shift Manager's Discretion Any off-normal event for which the Shift Manager determines that notification to Entergy management representatives and the NRC Resident Inspector is prudent.

Examples for consideration include:

1.

Bomb threats / security threats

2.

Unplanned power changes 2 15%

3.

Forced plant shutdown

4.

Entry into Technical Specification 3.0.3

5.

Unplanned entry into Technical Specification action statements

  • 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />
6.

Exceeding Technical Specification LCO out of service times

7.

Industrial accidents in RCA resulting in transport by ambulance

8.

Entry into any AOP except 1203.025 for severe thunderstorm warning 6.4.3 The Shift Engineer (from either unit) should notify the appropriate parties using Attachment 11.

[6.5 EMERGENCY RESPONSE DATA SYSTEM (ERDS) 6.5.1 The ERDS system is activated within one hour of an ALERT or higher emergency class classification.

ERDS may be activated using the RDACS computer terminals located in either Control Room or in the Technical Support Center.

A.

On the RDACS terminal, exit System Status Screen (F10).

B.

Select option 9 -

ERDS subsystem on the Main Menu.

C.

To start ERDS on Unit 1, select option 1.

D.

To start ERDS on Unit 2, select option 3.

E.

When emergency is over, select option 2 to stop ERDS on Unit 1, or select option 4 to stop ERDS on Unit 2.]

7.0 ATTACHMENTS AND F(

7.1 Attachment 7.2 Attachment 7.3 Attachment 7.4 Attachment 7.5 Attachment 7.6 Attachment 7.7 7.8 7.9 7.10 Attachment Attachment Attachment Attachment 7.11 Attachment 7.12 7.13 7.14 Form Form Form 1903.

1903.

1903.'

7.15 Form 1903.

7.16 Form 1903.

7.17 Form 1903.

7.18 Form 1903.

7.19 Form 1903.

7.20 7.21 7.22 7.23 7.24 7.2S Form Form Form Form Form Form 1903.

1903.

1903 1903 1903 1903 ORMS 1

Notification of Unusual Event 2 -

Alert 3 -

Site Area Emergency 4 -

General Emergency 5

Alternate ERO Notification Scheme 6 -

Protective Action Recommendations (PAR) for Generk Emergency 7 -

Core Fuel Damage Assessment, Unit 1 8

Core Fuel Damage Assessment, unit 2 9

Computerized Notification System (CNS)

Instructions 10 -

Emergency Class Notification Instructions 11 -

Non-Emergency Notifications of Off-Normal Events 011J -

NUE Emergency Direction and Control Checklist 011M -

Alert Emergency Direction and Control Checklist 011P -

SAE Emergency Direction and Control Checklist, Shift Manager 011Q SAE Emergency Direction and Control Checklist, TSC Director 011R -

SAE Emergency Direction and Control Checklist, EOF Director 011s -

GE Emergency Direction and Control Checklist, Shift Manager 011T -

GE Emergency Direction and Control Checklist, TSC Director 011U -

GE Emergency Direction and Control Checklist, EOF Director 011Y -

Emergency Class Initial Notification Message

.011Z Emergency Class Follow-up Notification Message

.011AA -Courtesy Call Notification Message

.011BB

-Initial Notification Checklist

.011CC -Follow-up Notification Checklist

.O11DD -Courtesy Call Notification Checklist

PROC.WORK PLAN NO.

PROCEDURE/WORK PLAN TITLE:

PAGE:

12 of 74 1903.011 EMERGENCY RESPONSE/NOTIFICATIONS CHANGE:

026444

[ATTACHMENT 1 NOTIFICATION OF UNUSUAL EVENT]

Upon declaration of a Notification of Unusual Event, the person with the responsibility for Emergency Direction and Control shall:

"* Complete the Emergency Direction and Control Checklist indicated below.

Any steps that are not appropriate for the event may be marked 'Not Applicable' (N/A).

"* Issue appropriate offsite protective action recommendations.

"* Ensure that notifications are completed in accordance with the required time limits.

At the termination of the event, the Shift Manager/TSC Director/EOF Director should forward all forms and other pertinent documents to Emergency Planning.

Forms used for NUE notification and response are as follows:

Form 1903.011J, "NUE Emergency Direction and Control Checklist" Form 1903.011Y, "Emergency Class Initial Notification Message" Form 1903.011Z, "Emergency Class Follow-up Notification Message" Form 1903.011BB, "Initial Notification Checklist" Form 1903.011CC, "Follow-up Notification Checklist"

Page 13 of 74 Page 1 of 2 NUE This form is intended to be used by the person with Emergency Direction and Control when a Notification of Unusual Event has been declared.

[]l.

Notification of Unusual Event declared:

Unit Time Date

    • EMERGENCY CLASSIFICATION ANNOUNCEMENT SHOULD BE MADE WITHIN 15 MINUTES OF THE DECLARATION**

jj2.

Conditions warranting declaration of a Notification of Unusual Event: EAL No.

==

Description:==

Fý3.

Direct the communicator(s)

(SE, opposite unit SE or Notifications Communicator) to initiate notifications and initiate NUE callout using the Computerized Notification System (CNS).

M3.1 IF only one unit is affected, T-HEN affected unit SE activates CNS (if not already performed for an NUE emergency class) in accordance with Attachment 9 of this procedure, opposite unit SE performs notifications using Forms 1903.011BB or 1903.011CC of this procedure.

M3.2 IF a dual unit emergency is occurring, T-HEN the Unit 1 SE performs initial notifications and the Unit 2 SE activates CNS (if not already performed for an NUE emergency class) unless additional communicators are available for these functions.

M3L.3 Inform the Control Room staff of the Emergency Class declaration.

M4. Make the following announcement over the plant paging system (dial 197):

"Attention all personnel.

Attention all personnel.

A Notification of Unusual Event has been declared on Unit (One/Two).

All personnel continue normal activities unless instructed otherwise."

E]4.1 Make the above announcement over the EOF Public Address System (dial 199 and pause approximately 15 seconds).

E]5.

[IF on-site personnel hazards exist, THEN direct implementation of protective actions as necessary.

E]5.1 Refer to Form 1903.030C, "Localized Evaluation Checklist",

to determine if a localized evacuation will be performed.]

Page 14 of 74 Page 2 of 2 M6. IF an approach route to the plant site should be avoided, THEN instruct Security to direct incoming traffic.

(Examples of this include security situations in which onsite/offsite personnel are directed to the EOF, radiological releases that prohibit entry to the site via either guard station, etc.)

n7. Direct Chemistry personnel (Initial Dose Assessor) to implement procedure 1904.002, "Offsite Dose Projection -

RDACS Computer Method".

Performed by:

FORM TITLE:

FORM NO.

REV.

NUE EMERGENCY DIRECTION AND CONTROL CHECKLIST 1903.011J 026-04-0 S1. I

PAGE: 15of 74 PROC./WORK PLAN NO.

PROCEDUREIWORK PLAN TTLE:

PAG EI 5 of 7 1903.011 EMERGENCY RESPONSEINOTIFICATIONS H

026-040 CHANGE:

026-04-0 ATTACHMENT 2 ALERT Upon declaration of an Alert, the person with the responsibility for Emergency Direction and Control shall:

"* Complete the appropriate Emergency Direction and Control Checklist indicated below. Any steps that are not appropriate for the event may be marked 'Not Applicable' (N/A).

"* Issue appropriate offsite protective action recommendations.

"* Ensure that notifications are completed in accordance with the required time limits.

At the termination of the event, the Shift Manager/TSC Director/EOF Director should forward all forms and other pertinent documents to Emergency Planning.

Forms used for Alert notification and response are as follows:

Form 1903.o011M, "Alert Emergency Direction and Control Checklist" Form 1903.011Y, "Emergency Class Initial Notification Message" Form 1903.011Z, "Emergency Class Follow-up Notification Message" Form 1903.011BB, "Initial Notification Checklist" Form 1903.011CC, "Follow-up Notification Checklist", Alternate ERO Notification Scheme

Page 16 of 74 Page 1 of 2 ALERT This form is intended to be used by the person with Emergency Direction and Control when an Alert has been declared.

E]1.

Alert declared: Unit Time Date

    • EMERGENCY CLASSIFICATION ANNOUNCEMENT SHOULD BE MADE WITHIN 15 MINUTES OF THE DECLARATION**

[12.

Conditions warranting declaration of an Alert:

EAL No.

==

Description:==

[313.

Direct the communicator(s)

(SE, opposite unit SE or Notifications Communicator) to initiate notifications and initiate ERO callout using the Computerized Notification System (CNS).

]3.1 IF only one unit is affected, T-HEN affected unit SE activates CNS (if not already performed for an Alert or higher emergency class) in accordance with Attachment 9 of this procedure, opposite unit SE performs notifications using Forms 1903.011BB or 1903.011CC of this procedure.

Eý3.2 IF a dual unit emergency is occurring, T-HEN the Unit 1 SE performs initial notifications and the Unit 2 SE activates CNS (if not already performed for an Alert or higher emergency-class) unless additional communicators are available for these functions.

E]3.3 Inform the Control Room staff of the Emergency Class declaration.

[n3.4 Inform both units Non-Licensed Operators (NLO's) to log onto the Emergency RWP.

n4. Make the following announcement over the plant paging system (dial 197):

"Attention all personnel. Attention all personnel. An Alert Emergency Class has been declared on Unit (One/Two).

Emergency response personnel report to your designated assembly areas.

All other personnel continue normal activities unless instructed otherwise."

E4.1 Make the above announcement over the EOF Public Address System (dial 199 and pause approximately 15 sec.)

E5.

[IF on-site personnel hazards exits, TH-EN direct implementation of protective actions as necessary.

E5.1 Refer to Form 1903.030C, "Localized Evacuation Checklist",

to determine if a localized evacuation will be performed.]

Page 17 of 74 Page 2 of 2 F16.

IF an approach route to the plant site should be avoided, THEN instruct Security to direct incoming traffic.

(Examples of this include security situations in which onsite/offsite personnel are directed to the EOF, radiological releases that prohibit entry to the site via either guard station, etc.)

[17.

Direct Chemistry personnel (Initial Dose Assessor) to the Control Room to implement procedure 1904.002,.Offsite Dose Projection RDACS Computer Method".

Performed by:

PROCJWORK PLAN NO.

PROCEDUREIWORK PLAN TITLE:

PAGE:

I of 74 1903.011 EMERGENCY RESPONSEINOTIFICATIONS C

026440 ATTACHMENT 3 SITE AREA EMERGENCY Upon declaration of a Site Area Emergency, the person with the responsibility for Emergency Direction and Control shall:

"* Complete the appropriate Emergency Direction and Control Checklist indicated below for your position (i.e.

SM, TSC Director, or EOF Director).

Any steps that are not appropriate for the event may be marked 'Not Applicable' (N/A).

"* Issue appropriate offsite protective action recommendations.

"* Ensure that notifications are completed in accordance with the required time limits.

At the termination of the event, the Shift Manager/TSC Director/EOF Director should forward all forms and other pertinent documents to Emergency Planning.

Forms used for Site Area Emergency notification and response are as follows:

Form 1903.011P, "SAE Emergency Direction and Control Checklist, Shift Manager"i (Shift Manager Only)

Form 1903.011Q, "SAE Emergency Direction and Control Checklist, TSC Director" (TSC Director Only)

Form 1903.011R, "SAE Emergency Direction and Control Checklist, EOF Director" (EOF Director Only)

Form 1903.011Y, "Emergency Class Initial Notification Message" Form 1903.011Z, "Emergency Class Follow-up Notification Message" Form 1903.011BB, "Initial Notification Checklist" Form 1903.011CC, "Follow-up Notification Checklist",

Alternate ERO Notification Scheme

Page 19 of 74 Page 1 of 4 SAE This form is intended to be used by the SHIFT MANAGER when a Site Area Emergency has been declared and the Shift Manager has the responsibility for Emergency Direction and Control.

-Ii.

Site Area Emergency declared:

unit_

Time Date_

    • EMERGENCY CLASSIFICATION /

PLANT EVACUATION ANNOUNCEMENT SHOULD BE MADE WITHIN 15 MINUTES OF THE DECLARATION**

E]2.

Conditions warranting declaration of a Site Area Emergency:

EAL No.

==

Description:==

j3.

Direct the communicator(s)

(SE, opposite unit SE or Notifications Communicator) to initiate notifications and initiate ERO callout using the Computerized Notification System (CNS).

Li3.1 IF only one unit is affected, THEN affected unit SE activates CNS (if not already performed for an Alert or higher emergency class) in accordance with Attachment 9 of this procedure, opposite unit SE performs notifications using Forms 1903.011BB or 1903.011CC of this procedure.

Li3.2 IF a dual unit emergency is occurring, THEN the Unit 1 SE performs initial notifications and the Unit 2 SE activates CNS (if not already performed for an Alert or higher emergency class) unless additional communicators are available for these functions.

F13.3 Inform the Control Room staff of the Emergency Class declaration.

R14.

Has a plant evacuation been performed?

Li NO THEN proceed to step 5.

LI YES THEN perform the following announcement:

LIA.

Dial 197 LIB.

Make the following announcement:

"Attention all personnel.

Attention all personnel.

A Site Area Emergency has been declared on Unit (One/Two).

Emergency response personnel report to your designated assembly areas."

[]C.

Repeat the above announcement using the EOF public address system by dialing 199 and pausing approximately 15 seconds before making the announcement.

FD. GO TO step 12.

FORM TITLE:

SAE EMERGENCY DIRECTION AND CONTROL CHECKLIST SHIFT MANAGER

Page 20 of 74 Page 2 of 4 Plant Evacuation Section M-5.

Determine the appropriate evacuation routes:

[]5.1 DOES a radiological or toxic gas release exist or is a release suspected, which is originating from the plant?

El YES THEN determine the available routes from the chart below using wind direction.

IF wind direction is From:

THEN use Evacuation Routes 150 to 225 degrees El 1 and 3 226 to 325 degrees F1 2 and 3 326 to 45 degrees 1l 1, 2 and 3 46 to 149 degrees El 1 10N -

THEN use routes 1,2 and 3 or any combination of routes.

E]5.2 Check the appropriate routes in the plant announcement, step 9 below.

[W6.

Determine any areas of the plant to avoid during evacuation or special protective measures to be taken by plant evacuees.

F-17.

Direct Security to perform the following (ext. 3388, 3108 or 3109):

E]7.1 If necessary, open and man the secondary guard station (if radiological conditions allow).

117.2 Perform initial accountability by (Time)

(30 minutes from SAE declaration) 1]8.

Contact Radiation Protection (CAI -

5166 or CA2 - 3018):

118.1 Request Health Physics coverage at the plant exit portal monitors.

F18.2 Instruct Health Physics personnel at the controlled access exit point to relax decontamination and radiation protection measures as necessary in order to expedite evacuation of the controlled access area.

FORM TITLE:

FORM NO.

REV.

SAE EMERGENCY DIRECTION AND CONTROL CHECKLIST 1903.011P 026-0" SHIFT MANAGER

Page 21. of 74 Page 3 of 4 F19.

Make the following announcement using the plant paging system (dial 197):

"Attention all personnel.

Attention all personnel.

A Site Area Emergency has been declared on Unit (One/Two).

Emergency response and emergency standby personnel report to your designated assembly areas and perform initial accountability.

All other personnel evacuate the plant using evacuation route(s) E] 1 F] 2

[] 3 and proceed to the Atkins Emergency Worker Center."

If necessary, include in the announcement any plant areas to avoid, or special protective actions to be taken by plant evacuees:

nl9.1 Sound the evacuation alarm for approximately 10 seconds.

n 9.2 Repeat the announcement at least 2 times, alternating the announcement with the plant evacuation alarm.

niC. Make the following announcement using the EOF public address system (dial 199 and pause approximately 15 seconds).

"Attention all personnel.

Attention all personnel.

A Site Area Emergency has been declared on Unit (One/Two).

Emergency response personnel report to your designated assembly areas."

n1l.

Instruct all Control Room personnel (operators, chemists, RP, etc.) to log into the designated security card reader using "0000".

Z1J.1 Instruct both units' Non-Licensed Operators (NLO's) in the field to log into the nearest security card reader using "0000" and log onto the emergency RWP.

M11.2 Inform the opposite unit Control Room personnel to log into the designated security card reader using "0000".

[:]12.

IF the incident extends into the Exclusion Area, T-HEN consider an Exclusion Area Evacuation.

Perform the follIowing if an Exclusion Area Evacuation is deemed necessary:

[]12.1 Request that the U.S. Army Corps of Engineers (telephone number located in Emergency Telephone Directory) control boat access to the portions of Lake Dardanelle within the exclusion area.

[]12.2 Direct Security to evacuate the Generation Support Building (GSB) and all buildings outside the security fence but within the exclusion area.

Plant Evacuation Section Ends FOMTTLE:

FORM NO.

RE=V.

SAE EMERGENCY DIRECTION AND CONTROL CHECKLIST 1903.011P 026-04-0 LORM TISHIFT MANAGER I

Page 22 of 74 Page 4 of 4

[Z13.

Direct Chemistry personnel (Initial Dose Assessor) to the Control Room to implement procedure 1904.002, "Offsite Dose Projection -

RDACS Computer Method".

E114.

IF an approach route to the plant site should be avoided, T-HEN instruct Security to direct incoming traffic.

(Examples of this include security situations in which onsite/offsite personnel are directed to the EOF, radiological releases that prohibit entry to the site via either guard station, etc.)

Performed by:

Shift Manager I FORM TITLI E:

SAE EMERGENCY DIRECTION AND CONTROL CHECKLIST SHIFT MANAGER I

Page 23 of 74 Page 1 of 3 SAE This form is intended to be used by the TSC DIRECTOR when a Site Area Emergency has been declared and the TSC Director has the responsibility for Emergency Direction and Control.

F]I.

Site Area Emergency declared:

Unit_

Time Date____

    • EMERGENCY CLASSIFICATION / PLANT EVACUATION ANNOUNCEMENT SHOULD BE MADE WITHIN 15 MINUTES OF THE DECLARATION**

L12.

Conditions warranting declaration of a Site Area Emergency:

EAL No.

==

Description:==

113.

Direct the Communicator to initiate the notifications specified on Form 1903.011BB, "Initial Notification Checklist".

3.1 Assign additional personnel to assist as necessary.

Fý4.

Has a plant evacuation been performed?

]

NO THEN proceed to step S.

LI YES THEN perform the following announcement:

[ElA.

Dial 197 MIB.

Make the following announcement:

"Attention all personnel.

Attention all personnel.

A Site Area Emergency has been declared on Unit (One/Two).

Emergency response personnel report to your designated assembly areas."

[:]C.

Repeat the above announcement using the EOF public address system by dialing 199 and pausing approximately 15 seconds before making the announcement.

LID.

GO TO step 11.

FORM TITLE:

FORM NO.

REV SAE EMERGENCY DIRECTION AND CONTROL CHECKLIST TSC DIRECTOR 1903.011Q 026-04-0

Page 24 of 74 Page 2 of 3 Plant Evacuation Section

[M5.

Determine the appropriate evacuation routes:

DOES a radiological or toxic gas release exist or is a release suspected, which is originating from the plant?

[] YES -

THEN determine the available routes from the chart below using wind direction.

IF wind direction is From:

THEN use Evacuation Routes 150 to 225 degrees

[1 1 and 3 226 to 325 degrees

[1 2 and 3 326 to 45 degrees

[1 1, 2 and 3 46 to 149 degrees

[1 1 LNO -

THEN use routes 1,2 and 3 or any combination of routes.

[16.

Determine any areas of the plant to avoid during evacuation or special protective measures to be taken by plant evacuees.

[17.

Direct Security to perform the following (ext. 3388, 3108 or 3109):

[E7.1 If necessary, open and man the secondary guard station (if radiological conditions allow).

[]7.2 Perform initial accountability by (Time)

(30 minutes from SAE declaration)

[18.

Contact Radiation Protection (CAl ext.

5166 or CA2 ext.

3018):

[18.1 Request Health Physics coverage at the plant exit portal monitors.

[18.2 Instruct Health Physics personnel at the controlled access exit point to relax decontamination and radiation protection measures as necessary in order to expedite evacuation of the controlled access area.

[119.

Direct the Shift Manager of the affected unit to perform the Emergency Class and plant evacuation announcement using Form 1903.011P steps 9, 10 and 11 of this procedure.

[E19.1 Inform the Shift Manager of the site evacuation routes determined in step 5.

[]9.2 Inform the Shift Manager of any plant areas to avoid during the plant evacuation and any special protective measures to be taken by plant evacuees.

[110.

Instruct the TSC/OSC personnel to log into the designated security card reader using "0000".

FORM TITLE:

FORM NO.

REV.

SAE EMERGENCY DIRECTION AND CONTROL CHECKLIST TSC DIRECTOR 1903.011Q 026-04-0 I

Page 25 of 74 Page 3 of 3

[:]1.

IF the incident extends into the Exclusion Area, THEN consider an Exclusion Area Evacuation.

Perform the following if an Exclusion Area Evacuation is deemed necessary:

RII1.1 Request that the U.S. Army corps of Engineers (telephone number located in Emergency Telephone Directory) control boat access to the portions of Lake Dardanelle within the exclusion area.

F111.2 Direct Security to evacuate the Generation Support Building (GSB) and all buildings outside the security fence but within the exclusion area.

Plant Evacuation Section Ends Fl12. Direct Chemistry personnel (Initial Dose Assessor) to the Control Room to implement procedure 1904.002, "Offsite Dose Projection -

RDACS Computer Method".

F113.

IF an approach route to the plant site should be avoided, THEN instruct Security to direct incoming traffic.

Performed by Technical Support Center Director FRFORM TITLE:NO SAE EMERGENCY DIRECTION AND CONTROL CHECKLIST TSC DIRECTOR 1903.011Q 026-04-0

Page 26 of 74 Page 1 of 1 SAE This form is intended to be used by the EOF DIRECTOR when a Site Area Emergency has been declared and the EOF Director has the responsibility for Emergency Direction and Control.

E]l.

Site Area Emergency declared:

Unit Time Date

    • EMERGENCY CLASSIFICATION /

PLANT EVACUATION ANNOUNCEMENT SHOULD BE MADE WITHIN 15 MINUTES OF THE DECLARATION**

L 2.

Has a plant evacuation been performed?

fl NO -

THEN iimediately request the TSC Director to perform the Plant Evacuation Section of Form 1903.011Q.

If the TSC Director is not available then request the Shift Manager to perform the Plant Evacuation Section of Form 1903.011P. Go to step 3.

M YES -

THEN perform the following:

[]A.

Dial 199 FIB.

Make the following announcement:

"Attention all personnel.

Attention all personnel.

A Site Area Emergency has been declared on Unit (One/Two).

Emergency response personnel report to your designated assembly areas."

EýC. Repeat the above announcement using the plant public address system by dialing 197 and pausing approximately 15 seconds before making the announcement.

F-3.

Direct the Communicator to initiate the notifications specified on Form 1903.011BB, "Initial Notification Checklist."

E]3.1 Assign additional personnel to assist as necessary.

E]4.

Conditions warranting declaration of a Site Area Emergency:

EAL NO.

==

Description:==

[-5.

Announce emergency class declaration to the EOF staff.

nl6.

Request the TSC Director to evaluate the need for an Exclusion Area Evacuation.

Mj7.

Direct Chemistry personnel (Initial Dose Assessor) to the Control Room to implement procedure 1904.002, "Offsite Dose Projection -

RDACS Computer Method".

Performed by:

Emergency Operations Facility Director FORM TITLE:

FORM NO.

RE-V.

SAE EMERGENCY DIRECTION AND CONTROL CHECKLIST EOF DIRECTOR 1903.011IR 026-04-0

PROCJWORK PLAN NO.

PROCEDUREIWORK PLAN TITLE:

PAGE-27 of 74 1903.011 EMERGENCY RESPONSEINOTIFICATIONS CHANGE:

02604 ATTACHMENT 4 GENERAL EMERGENCY Upon declaration of a General Emergency, the person with the responsibility for Emergency Direction and Control shall:

"* Complete the appropriate Emergency Direction and Control Checklist indicated below for your position (i.e. SM, TSC Director, or EOF Director).

Any steps that are not appropriate for the event may be marked 'Not Applicable' (N/A).

"* Issue appropriate offsite protective action recommendations.

"* Ensure that notifications are completed in accordance with the required time limits.

At the termination of the event, the Shift Manager/TSC Director/EOF Director should forward all forms and other pertinent documents to Emergency Planning.

Forms used for General Emergency notification and response are as follows:

Form 1903.011S, "GE Emergency Direction and Control Checklist, Shift Manager" (Shift Manager Only)

Form 1903.011T, "GE Emergency Direction and Control Checklist, TSC Director" (TSC Director Only)

Form 1903.011U, "GE Emergency Direction and Control Checklist, EOF Director" (EOF Director Only)

Form 1 903.011Y, "Emergency Class Initial Notification Message" Form 1903.011Z, "Emergency Class Follow-up Notification Message" Form 1903.011BB, "Initial Notification Checklist" Form 1903.011CC, "Follow-up Notification Checklist", Alternate ERO Notification Scheme, Protective Action Recommendations (PAR) for General Emergency,

Core Fuel Damage Assessment, Unit 1,

Core Fuel Damage Assessment, Unit 2

Page 28 of 74 Page 1 of 4 GE This form is intended to be used by the SHIFT MANAGER when a General Emergency has been declared and the Shift Manager has the responsibility for emergency Direction and Control.

El.

General Emergency declared:

Unit Time Date

    • EMERGENCY CLASSIFICATION / PLANT EVACUATION ANNOUNCEMENT SHOULD BE MADE WITHIN 15 MINUTES OF THE DECLARATION**

[]2.

Conditions warranting declaration of a General Emergency:

EAL No.

==

Description:==

n13.

Direct the communicator(s)

(SE, opposite unit SE or Notifications Communicator) to initiate notifications and initiate ERO callout using the Computerized Notification System (CNS).

[]3.1 IF only one unit is

affected, THEN affected unit SE activates CNS (if not already performed for an Alert or higher emergency class) in accordance with Attachment 9 of this procedure, opposite unit SE performs notifications using Forms 1903.011BB or 1903.011CC of this procedure.

n13.2 IF a dual unit emergency is occurring, THEN the Unit 1 SE performs initial notifications and the Unit 2 SE activates CNS (if not already performed for an Alert or higher emergency class) unless additional communicators are available for these functions.

n13.3 Inform the Control Room staff of the Emergency Class declaration.

F14.

Has a plant evacuation been performed, LI NO-GO TO Step 5 E YES THEN perform the following:

LIA. Dial 197 LIE.

Make the following announcement:

"Attention all personnel.

Attention all personnel.

A General Emergency has been declared on Unit (One/Two).

Emergency response personnel report to your designated assembly areas."

EC. Repeat the above announcement using the EOF public address system by dialing 199 and pausing approximately 15 seconds before making the announcement.

EID.

GO TO step 12.

FORM TITLE:

FORM NO.

REV.

GE EMERGENCY DIRECTION AND CONTROL CHECKLIST 1903.011S 026-04-0 SHIFT MANAGER

Page 29 of 74 Page 2 of 4 Plant Evacuation Section E]5.

Determine the appropriate evacuation routes:

1]5.1 DOES a radiological or toxic gas release exist or is a release suspected, which is originating from the plant?

fl YES THEN determine the available routes from the chart below u ing wind direction.

IF wind direction is From:

THEN use Evacuation Routes 150 to 225 degrees F1 I and 3 226 to 325 degrees E] 2 and 3 326 to 45 degrees 1 1, 2 and 3 46 to 149 degrees Ij 1

]

NO THEN use routes 1,2 and 3 or any-combination of routes.

115.2 Check the appropriate routes in the plant announcement, step 9 below.

El6.

Determine any areas of the plant to avoid during evacuation and/or special protective measures to be taken by plant evacuees.

List these instructions in evacuation announcement step 9.

17.

Direct Security to perform the following (ext. 3388, 3108 or 3109):

F117.1 If necessary, open and man the secondary guard station (if radiological conditions allow).

117.2 Perform initial accountability by (Time)

(30 minutes from GE declaration)

E]8.

Contact Radiation Protection (CAI -

5166 or CA2 - 3018):

1]8.1 Request Health Physics coverage at the plant exit portal monitors.

118.2 Instruct Health Physics personnel at the controlled access exit point to relax decontamination and radiation protection measures as necessary in order to expedite evacuation of the controlled access area.

SFORM TITLE.

EMERGENCY DIRECTION AND CONTROL CHECKLIST 1903.011S 026R4 SHIFT MANAGER

Page 30 of 74 Page 3 of 4 E[:9.

Make the following announcement using the plant paging system (dial 197):

"Attention all personnel.

Attention all personnel.

A General Emergency has been declared on Unit (One/Two).

Emergency response and emergency standby personnel report to your designated assembly areas and perform initial accountability.

All other personnel evacuate the plant using evacuation route(s) E] 1 [] 2 El 3 and proceed to the Atkins Emergency worker Center."

If necessary, include in the announcement any plant areas to avoid, or special protective actions to be taken by plant evacuees:

El9.1 Sound the evacuation alarm for approximately 10 seconds.

[]9.2 Repeat the announcement at least 2 times, alternating the announcement with the plant evacuation alarm.

E10.

Make the following announcement using the EOF public address system (dial 199 and pause approximately 15 seconds).

"Attention all personnel.

Attention all personnel.

A General Emergency has been declared on Unit (One/Two).

Emergency response personnel report to your designated assembly areas."

E li.

Instruct all Control Room personnel (operators, chemists, RP, etc.) to log into the designated security card reader using "0000".

Zý11.1 Instruct both units' Non-Licensed Operators (NLO's) in the field to log into the nearest security card reader using "0000" and log onto the emergency RWP.

[_11.2 Inform the opposite unit Control Room personnel to log into the designated security card reader using "0000".

El12. Has an exclusion area evacuation been performed?

EL YES GO TO Step 13.

EL NO THEN perform the following:

El Request that the U.S.

Army Corps of Engineers (telephone number located in Emergency Telephone Directory) control boat access to the portions of Lake Dardanelle within the exclusion area.

El Direct Security to evacuate the Generation Support Building (GSB) and all buildings outside the security fence but within the exclusion area.

Plant Evacuation Section Ends FORM TITLE:

S RM NO.

REV.

GE EMERGENCY DIRECTION AND CONTROL CHECKLIST 1903.011S 026-04-0 SHIFT MANAGERIII

Page31 of 74 Page 4 of 4 fl13. Determine the appropriate Protective Action Recommendation using Attachment 6, "Protective Action Recommendations (PAR) for General Emergency".

PAR No.

E114. Direct Chemistry personnel (Initial Dose Assessor) to the Control Room to implement procedure 1904.002, "Offsite Dose Projection -

RDACS Computer Method".

fl15. IF an approach route to the plant site should be avoided, T-HEN instruct Security to direct incoming traffic.

(Examples of this include s'ecurity situations in which onsite/offsite personnel are directed to the EOF, radiological releases which prohibit entry to the site via either guard station, etc.)

Performed by :

Shift Manager I FORM TITLE GE EMERGENCY DIRECTION AND CONTROL CHECKLIST SHIFT MANAGER

Page 32 of 74 Page 1 of 3 GE This form is intended to be used by the TSC DIRECTOR when a General Emergency has been declared and the TSC Director has the responsibility for Emergency Direction and Control.

Mi. General Emergency declared:

unit Time_

Date_

    • EMERGENCY CLASSIFICATION / PLANT EVACUATION ANNOUNCEMENT SHOULD BE MADE WITHIN 15 MINUTES OF THE DECLARATION**

F-2.

Conditions warranting declaration of a General Emergency:

EAL No.

==

Description:==

Dý3.

Direct the Communicator to initiate the notifications specified on Form 1903.011BB, "Initial Notification Checklist".

E]3.1 Assign additional personnel to assist as necessary.

L14.

Has a plant evacuation been performed?

LI NO Go To step 5 E] YES perform the following:

E]A.

Dial 197 FlB.

Make the following announcement:

"Attention all personnel.

Attention all personnel.

A General Emergency has been declared on Unit (One/Two).

Emergency response personnel report to your designated assembly areas."

0C.

Repeat the above announcement using the EOF public address system by dialing 199 and pausing approximately 15 seconds before making the announcement.

[-D.

GO TO step 11.

FORM TITLE:

FORM NU.

IRV GE EMERGENCY DIRECTION AND CONTROL CHECKLIST TSC DIRECTOR 1903.011T J "026-04-0

Page 33 of 74 Page 2 of 3 Plant Evacuation Section F15.

Determine the appropriate evacuation routes:

DOES a radiological or toxic gas release exist or is a release suspected, which is originating from the plant?

E YES -

THEN determine the available routes from the chart below using wind direction.

IF wind direction is From:

THEN use Evacuation Routes 150 to 225 degrees El 1 and 3 226 to 325 degrees

[

2 and 3 326 to 45 degrees E3 1, 2 and 3 46 to 149 degrees

[] 1

[

NO -

THEN use routes 1,2 and 3 or any combination of routes.

E]6.

Determine any areas of the plant to avoid during evacuation or special protective measures to be taken by plant evacuees.

07. Direct Security to perform the following (ext. 3388, 3108 or 3109):

F17.1 If necessary, open and man the secondary guard station (if radiological conditions allow).

F17.2 Perform initial accountability by (Time)

(30 minutes from GE declaration)

R]8 Contact Radiation Protection (CAI -

5166 or CA2 - 3018):

[-8.1 Request Health Physics coverage at the plant exit portal monitors.

[18.2 Instruct Health Physics personnel at the controlled access exit point to relax decontamination and radiation protection measures as necessary in order to expedite evacuation of the controlled access area.

F-19.

Direct the Shift Manager of the affected unit to perform the Emergency Class and plant evacuation announcement using Form 1903.011S steps 9, 10 and 11 of this procedure.

[:]9.1 Inform the Shift Manager of the site evacuation routes determined in step 5.

F19.2 Inform the Shift Manager of any plant areas to avoid during the plant evacuation and any special protective measures to be taken by plant evacuees.

E]10. Instruct the TSC/OSC personnel to log into the designated security card reader using "0000".

FORM TITLE:

RM NO.

REV.

GE EMERGENCY DIRECTION AND CONTROL CHECKLIST TSC DIRECTOR 1903.0tlT 026-04-0

Page 34 of 74 Page 3 of 3

[]11.

Has an Exclusion Area evacuation been performed?

E] YES Go To Step 12 Ei NO -

THEN perform the following:

Fj Request that the U.S. Army corps of Engineers (Emergency Telephone Directory, section 6) to control boat access to the portions of Lake Dardanelle within the exclusion area.

F1 Direct Security to evacuate the Generation Support Building (GSB) and all buildings outside the security fence but within the exclusion area.

Plant Evacuation Section Ends L112. Determine the appropriate Protective Action Recommendation using Attachment 6, "Protective Action Recommendations (PAR) for General Emergency".

PAR No.

[]13.

Direct Chemistry personnel (Initial Dose Assessor) to the Control Room to implement procedure 1904.002, "Offsite Dose Projection -

RDACS Computer Method".

ý1!4.

IF an approach route to the plant site should be avoided, THEN instruct Security to direct incoming traffic.

Performed by :__

Technical Support Center Director

" GE EMERGENCY DIRECTION AND CONTROL CHECKLIST TSC DIRECTOR 1903.011T 026-04-0

Page 35 of 74 Page 1 of 2 GE This form is intended to be used by the EOF DIRECTOR when a General Emergency has been declared and the EOF Director has the responsibility for Emergency Direction and Control.

j0I.

General Emergency declared:

unit Time Date____

    • EMERGENCY CLASSIFICATION AND PLANT EVACUATION ANNOUNCEMENT SHOULD5 BE MADE WITHIN 15 MINUTES OF THE DECLARATION**

112.

Has a plant evacuation been performed?

M NO - THEN immediately request the TSC Director to perform the Plant Evacuation Section of Form 1903.011T of this procedure.

If the TSC Director is not available then request the Shift Manager to perform the Plant Evacuation Section of Form 1903.011S.

Go to step 3.

MI YES -

Perform the following:

l]A.

Dial 199 MB. Make the following announcement:

"Attention all personnel.

Attention all personnel.

A General Emergency has been declared on Unit (One/Two).

Emergency response personnel report to your designated assembly areas."

MC. Repeat the above announcement using the plant public address system by dialing 197 and pausing approximately 15 seconds before making the announcement.

1]3.

Direct the Communicator to initiate the notifications specified on Form 1903.011BB, "Initial Notification Checklist".

[3.1 Assign additional personnel to assist as necessary.

M14.

Conditions warranting declaration of a General Emergency:

EAL No.

==

Description:==

E]5.

Determine the appropriate Protective Action Recommendation using Attachment 6, "Protective Action Recommendations (PAR) for General Emergency".

PAR No.

REAM Review:

F]6.

Announce emergency class declaration to the EOF staff.

FORM TITLE:

J GE EMERGENCY DIRECTION AND CONTROL CHECKLIST EOF DIRECTOR 1903.011U 026-04-0

Page 36 of 74 Page 2 of 2 L17.

Request the TSC Director to perform an exclusion area evacuation if the evacuation has not already been performed.

E]8.

Direct Chemistry personnel (Initial Dose Assessor) to the Control Room to implement procedure 1904.002, "Offsite Dose Projection -

RDACS Computer Method".

Performed by:

Emergency Operations Facility Director FORM TITLE:

D FORM NO.

REV.

GE EMERGENCY DIRECTION AND CONTROL CHECKLIST EOF DIRECTOR 1903.011U 026-04-0

Page 37 of 74 Page 1 of 1 INITIAL NOTIFICATION MESSAGE Use this form for Emergency Class Declarations, Changes (Upgrade or Downgrade),

Protective Action Recommendations (PAR's) or Terminations.

State and local officials must be notified of the Emergency Class or PAR within 15 minutes of the emergency class declaration time or PAR Change.

1.

MESSAGE NUMBER:

2.

MESSAGE:

This is at Arkansas Nuclear One.

My (Communicator' name) phone number is (479) 858

-This is E]

AN ACTUAL EVENT f

A DRILL.

[]

A NOTIFICATION OF UNUSUAL EVENT was DECLARED ZI An ALERT was DECLARED Li A SITE AREA EMERGENCY was DECLARED LI A GENERAL EMERGENCY was DECLARED K] The Emergency was TERMINATED on K]

UNIT 1 E]

UNIT 2 on (date) at (time) based on (date)

(time)

EAL No.

==

Description:==

The wind is at miles per hour and from degrees.

There E] is LI is not a radioactive gaseous or liquid release taking place at this time due to this event.

Recommended Protective Actions are:

LI NONE AT THIS TIME III EVACUATE ZONES:

E]

SHELTER ZONES:

Comments:

More information will follow shortly.

[3.

APPROVED:

E]

Shift Manager E]

TSC Director E]

EOF Director]

FORM TITLE: EMERGENCY CLASS INITIAL NOTIFICATION MESSAGE 1903.011Y 026-04

Page 38 of 74 Page 1 of 1 FOLLOWUP NOTIFICATION MESSAGE

1.

MESSAGE NO.

2.

Reported By:

3.

This is

[] AN ACTUAL EVENT

4.

EMERGENCY CLASSIFICATION:

El NOTIFICATION OF UNUSUAL EVENT 13 ALERT

5.

DECLARED ON:

E] Unit 1 E] Unit 2

6.

PROGNOSIS:

13 Degrading Tel. No.

(479) 858-

[] A DRILL 1 SITE AREA EMERGENCY E3 TERMINATION E] GENERAL EMERGENCY Date:

Ml Stable Time:

El Improving

7.

RECOMMENDED PROTECTIVE ACTIONS:

[1 NONE AT THIS TIME 13 EVACUATE ZONES:

13 SHELTER ZONES:

8.

INCIDENT DESCRIPTION/COMMENTS:

EAL NO.

EAL CONDITION:

COMMENTS:

9.

REACTOR SHUTDOWN?

[] NO E] YES Date:

Time:

10.

OTHER UNIT STATUS:

11.

MET DATA: Wind AT Stability Class:

13 A Precipitation:

13 Non

12.

RADIOLOGICAL RELEASE:

There is:

MPH FROM Degrees

[]B 1C

[3_D Le E] Rain

[] Sleet E] Snow 13 NO GASEOUS RADIOACTIVE RELEASE exceeding federally approved operating limits taking place at this time due to this event. Go to Item 13.

13 A GASEOUS RADIOACTIVE RELEASE exceeding federally approved operating limits.

RELEASE OCCURRED BUT STOPPED; Duration:

hrs RELEASE OCCURRING: Time Started Expected Duration:

RELEASE RATE (Ci/sec):

PARTICULATE:

IODINE:

NOBLE GAS:

ESTIMATE OF PROJECTED OFF-SITE DOSE:

TEDE DOSE (tmRem)

CHILD THYROID DOSE (CDE)

(mRem) 0.62 miles:

3.45 miles:

0.62 miles:

3.45 miles:

1.45 miles:

7.23 miles:

1.45 miles:

7.23 miles:

13.

LIQUID RELEASE?

El Yes

[] No (GO TO Item 14)

El Greater than ODCM Limitations--[

Greater than 10 X ODCM Limitations

14.

APPROVED :

Shift Manager LI TSC Director LI EOF Director rFORM TITLE:

N F

T M

SFORM NO.

REV.

EMERGENCY CLASS FOLLOWUP NOTIFICATION MESSAGE026-04-0

[E]

hrs

Page 39 of 74 Page 1 of 1 COURTESY CALL NOTIFICATION MESSAGE Use for COURTESY CALLS MESSAGE:

This is at Arkansas Nuclear One.

My

{Communicator' s name) phone number is (479) 858 This COURTESY CALL is being made because:

F1 An UNPLANNED release of radioactive material has occurred OR may occur.

r An UNPLANNED reactor trip from power has occurred.

[

An event has occurred for which a news release is planned.

[]

A notification has been made or will be made to other government agencies for events that have impacted or will impact the public health and safety.

At on the following event(s)occurred on

{time)

)date)

U] UNIT 1 U] UNIT 2 U The ANO Site (describe event):

APPROVED:

Shift Manager

' FORM NO.

I REV.

FORM TITLE:

COURTESY CALL NOTIFICATION MESSAGE 1903.011AA 026-04-0

Page 40 of 74 Page 1 of 5 ACTIONS FOR INITIAL NOTIFICATION The Emergency Telephone Directory contains emergency telephone Eumbr The Arkansas Department of Health (ADH)

SHALL be notified within 15 minutes of an:

0 0

S 0

Emergency Class Declaration Emergency Class Change (Upgrade or Downgrade)

PAR Change Termination INSTRUCTIONS

1. Complete 1903.011Y for Message #

Refer to Attachment 10 for instructions.

2.

Place 1903.011Y face down in DEF/VS fax document tray Press RED speed dial button.

Press RED fax button.

Time:

Date:

3.

IF:

"* You are the EOF Notifications Communicator AND

"* The ADH is collocated with ANO AND

"* The EOF Director has ED&C, THEN perform the following:

a.

Give the notifications forms to the State TOCD directly.

b.

Go to step 6.

CONTINGENCY ACTIONS

1.

None

2.

Use non-dedicated fax to send 1903.011Y to ADH.

Fax number:

  • 9-1-501-671-1406*

Time:

Date: _

Use non-dedicated fax to send 1903.011Y to the (do not send the fax to your own facility):

CR:

  • 858-7414*

TSC: *858-6622*

EOF: *858-6957*

3.

None

4.

IF this is a termination message

4.

None T-HEN GO TO Step 6.

NOTE The material contained within the symbols

(*)

is proprietary or private information.

IFORM NO.

REV.

FORM TITLE:

INITIAL NOTIFICATION CHECKLIST

[1903.011BB]

026-04-0

Page 41 of 74 Page 2 of 5 INSTRUCTIONS

5.

IF the ERO has already been activated f*or an ALERT or higher emergency AND the ERO is responding or staffed, THEN GO TO Step 6.

5.1 [Verify CNS activated in accordance with Attachment 9 Section 4 of this procedure.]

SFORM TITLE:I CONTINGENCY ACTIONS 5.1 Page the ERO via telephone in accordance with Attachment 9 section 7.

'-A-INT~

NOOFCAMO CHCKITTOMLOE:~4~

INITIAL NOTIFICATION CHECKLIST I FORM NO.

!REV.

[1903.011 BB] 1026-04-0

Page 4 2 of 74 Page 3 of 5 INSTRUCTIONS

6.

Confirm fax receipt.

NOTE DEF/VS will send you a return fax of the message you sent.

Do NOT perform roll-call until you have received this fax.

6.1.

Pick up DEF/VS phone handset.

Press RED button on DEF/VS phone.

Ask responding agencies to hold.

Read message to agencies:

"I am calling from Arkansas Nuclear One.

Please confirm receipt of "Initial"

fax, message

-n Perform roll-call:

U]

Conway County U

Johnson County U

Logan County

[]

Pope County Yell County U

Department of Emergency Management U

Arkansas Dept. of Health Person Contacted Time CONTINGENCY ACTIONS

6.

None NOTE Use of DEM Emergen-c-yAction Authenticator may be required when contacting agencies by non-dedicated phone.

6.1 Call ADH at *9-1-501-661-2136* an confirm fax receipt.

(Alternate number 1-800-633-1735")

Person Contacted Time Request ADH to notify other agencies.

IF ADH cannot be reached by phone, THEN contact DEM at *9-1-501-730 9750* or radio (Channel 6 unscrambled) and request them to relay notification.

6.2 IF any agencies do NOT confirm fax receipt, THEN request ADH to confirm receipt with those agencies.

IF ADH does not respond to roll

call, THEN Call ADH at *9-1-501-661 2136* and confirm fax receipt.

(Alternate number *9-1-800-633 1735*)

Person Contacted Time IF ADH cannot be reached by phone, THEN contact DEM at *9-I-501-730 9750* or radio (Channel 6 unscrambled) and request them to relay notification.

I FORM TITLE:

INITIAL NOT "IFICATION CHECKLIST U

FORM NO.

REV.

[190RM NO.

0 REV.

[1903.0111BB]

1026-04-0 I I

id 6.2 I

Page 4 3 of 74 page 4 of 5 INSTRUCTIONS CONTINGENCY ACTIONS NOTE

[The Nuclear Regulatory Commission (NRC)

SHALL be notified immediately following notification of the ADH and SHALL NOT exceed 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> following the declaration of an emergency class.]

7.

[Using ENS telephone call the NRC,

7.

[Using commercial telephone, call the numbers located on telephone.

Read NRC, 1-301-816-5100*.

Read message message from 1903.011Y to NRC from 1903.011Y to NRC Communicator.]

Communicator.]

Person Contacted Time Person Contacted Time

8.

[Use non-dedicated fax to send 1903.011Y

8.

None to NRC Operations Center at *9-1-301 816-5151".]

NOTE ERDS must be started within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> of the declaration of an ALERT or higher emergency class.

[9.

IF an ALERT or higher emergency class

9.

None has been declared, THEN verify ERDS is operating for the affected unit.

9.1 From the RDACS Main Menu screen, a "I" or "2" will be displayed at the top of the screen if ERDS is sending data to the NRC.

If the affected units' number is displayed go to step 10.

9.2 IF you are the EOF Notifications Eommunicator, THEN notify the TSC Notifications C-omunicator to perform steps 9.3 through 9.5.

9.3 Exit to the Main Menu screen on the RDACS terminal.

9.4 Select option 9 (ERDS Subsystem) on the Main Menu.

9.5 Start ERDS by selecting option 1 for Unit 1 OR option 3 for Unit 2.]

NOTE The material contained within the symbols (*)

is proprietary or private information.

FORM TITLE:

F ORM NO.

REV.

INITIAL NOTIFICATION CHECKLIST I

1903.011 BBJ 026-04-0

10. IF not already performed, THEN call out an additional person to perform ongoing ENS communications.

Priority as follows (Unit specific)

i.

Operation Manager

2. Assistant Operations Manager
3.

Off-duty Shift Manager

4.

Off-duty Senior Reactor Operator

11. A follow-up notification using Form "1903.011CC is required within approximately 30 minutes after this notification.

Actions performed by:

(Name)

(Name) 10. None

11. None (Date)

NOTE Upon termination of event, copies of Notification Forms, Checklists and other related documentation should be forwarded to Emergency Planning.

Originals should be submitted to ANO records.

IFORM NO, REV.

TI

[1903.OIBBI 026-04-01 Page 44 of 74 Page 5 of S (Time)

FORM TITLE:

INITIAL NOTIFICATION CHECKLIST m

I

Page 45 of 74 Page 1 of 4 ACTIONS FOR FOLLOWUP NOTIFICATION Follow-up Notifications are required:

  • Within approximately 30 minutes after an Initial Notification When a significant change occurs such as
1. Prognosis changes
2.

Radiological release begins or ends

3. Radiological release rate changes significantly
  • Within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> after the last notification
  • As directed by the person with Emergency Direction and Control TheEmegeny Tlehon Diectry NOTE The Emergency Telephone Directory contains emergency telephone numbers.

INSTRUCTIONS CONTINGENCY ACTIONS I.

Complete 1903.011Z for

1. None Message #

Refer to Attachment 10 for instructions.

2.

Place 1903.011Z face down in DEF/VS

2.

Use non-dedicated fax to send document tray 1903.011Z to ADH at *9-1-501-671 Press RED speed dial button.

1406*.

Press RED fax button.

Time:

Date:

Time:

Date:

Use non-dedicated fax to send 1903.011Z to the (do not fax to your own facility):

CR:

  • 858-7414*

TSC:

  • 858-6622*

EOF:

  • 858-6957*
3.

IF:

  • You are the EOF Notifications Communicator AND
  • The ADH is collocated with ANO AND

& The EOF Director has ED&C, THEN Give the notifications forms to the State TOCD directly.

NOTE The material contained within the symbols (*) is proprietary or private information.

FORM TITLE:

FORM NO.

REV.

FOLLOWUP NOTIFICATION CHECKLIST

[1903.011CC]

026-04-0

Page 46 of 74 INSTRUCTIONS

4.

Confirm fax receipt.

NOTE DEF/VS will send you a return fax of the message you sent.

Do NOT perform roll-call until you have received this fax.

4.1 Pick up DEF/VS phone handset.

Press RED button on DEF/VS phone.

Ask responding agencies to "Hold".

Read message to agencies:

"I am calling from Arkansas Nuclear One.

Please confirm receipt of "Follow-up" fax, message #

-" A 4.2 Perform roll-call:

Ii Q

M M]

n]

Conway County Johnson County Logan County Pope County Yell County Department of Emergency Management Arkansas Dept. of Health Person Contacted Time Page 2 of 4 CONTINGENCY ACTIONS

4.

None NOTE Use of DEM Emergency Action Authenticator may be required when contacting agencies by non-dedicated phone.

4.1 Call ADH at *9-1-501-661-2136* and confirm fax receipt.

(Alternate number *9-1-800-633-1735*)

Person Contacted Time Request ADH to notify other agencies.

IF ADH cannot be reached by phone, THEN contact DEM at *9-1-501-730 9750* or radio (Channel 6 unscrambled) and request them to relay notification.

4.2 IF any agencies do NOT confirm fax

receipt, THEN request ADH to confirm receipt with those agencies.

IF ADH does not respond to roll

call, THEN Call ADH at *9-1-501-661 2136* and confirm fax receipt.

(Alternate number *9-1-800-633 1735*)

Person Contacted Time IF ADH cannot be reached by phone, THEN contact DEM at 1-501-730 9750* or radio (Channel 6 unscrambled) and request them to relay notification.

FORM TITLE:

FORM NO.

REV.

SFOLLOWUP NOTIFICATION CHECKLIST

[1903.011CC]

026-04-0

Page 47 of 74 Page 3 of 4 NOTE

[The Nuclear Regulatory Commission (NRC)

SHALL be notified immediately following notification of the ADH and NOT later than 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> following the declaration of an emergency class.]

INSTRUCTIONS CONTINGENCY ACTIONS

5.

[IF the ERO is not responding to

5.

None

plant, THEN verify CNS is running the appropriate scenario by any of the methods in.]

Can only be performed in Control Room or TSC.

NOTE ERDS must be started within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> of the declaration of an ALERT or higher emergency class.

[6.

IF an ALERT or higher emergency class

6.

None has been declared, THEN verify ERDS is operating for the affected unit.

6.1 From the RDACS Main Menu screen, a "I" or "2" will be displayed at the top of the screen if ERDS is sending data to the NRC.

If the affected units number is displayed go to step 7.

6.2 IF you are the EOF Notifications Communicator, THEN notify the TSC Notifications Communicator to perform steps 6.3 through 6.5.

6.3 Exit to the Main Menu screen on the RDACS terminal.

6.4 Select option 9 (ERDS Subsystem) on the Main Menu.

6.5 Start ERDS by selecting option 1 for Unit 1 OR option 3 for Unit 2.]

FORM NO.

REV.

RM TITLE:

FOLLOWUP NOTIFICATION CHECKLIST

[1903.OIICC 1 026 0

Page 48 of 74 Page 4 of 4 NOTE The NRC Event Notification Worksheet (NRC Form 361) may be used as an aid in providing information about the emergency to the NRC.

7.

[Using ENS telephone, call the NRC, numbers listed on telephone.

Transmit information from 1903.011Z and NRC Form 361 (if completed).]

Person Contacted T-ime S8.

[Using commercial facsimile, number

  • 9-1-301-816-551*,

transmit information from 1903.011Z and NRC Form 361 (if completed) to the NRC Operations Center.]

Actions performed by:

(name)

( name )

[Using commercial telephone, call the

NRC,
  • 9-1-301-816-5100*.

Transmit information from 1903.011Z and NRC Form 361 (if completed).]

Person Contacted Ti-me

8.

None (date)

(time)

NOTE Upon termination of event, copies of Notification Forms, Checklists and other related documentation should be forwarded to Emergency Planning.

Originals should be submitted to ANO records.

FORM TITLE:

FORM NO.

REV.

FOLLOWUP NOTIFICATION CHECKLIST I

[1903.011CC]

026-04-0 7

Page 49 of 74 Page 1 of 2 Actions for Courtesy Calls NOTE Courtesy Calls are required for the following NON-Emergency Class events:

"* An UNPLANNED release of radioactive material has occurred OR may occur.

"* An UNPLANNED reactor trip from power has occurred.

"* An event has occurred for which a news release is planned.

"* A notification has been made or will be made to other government agencies for events that have impacted or will impact the public health and safety.

NOTE Notification to the ADH and the NRC SR=' be made as soon as practical but NOT later than four hours following the event.

INSTRUCTIONS 1

1. Complete 1903.011AA.

CONTINGENCY ACTIONS

11. None NOTE Use of DEM Emergency Action Authenticator may be required when contacting agencies by non-dedicated phone.

2.Use non-dedicated fax to send 1903.011AA to ADH at *9-1-501-671-1406*.

Time:

Date: _

3.Confirm fax receipt by calling ADH at *9 1-501-661-2136*.

(Alternate number *9-1 800-633-1735*)

Person Contacted Time 4.Start CNS using Att.

9, Section 3 5.Complete the NRC Event Notification Worksheet (NRC Form 361).

6.Use ENS phone to transmit information from NRC Form 361 to NRC.

Person contacted Time 2.Call ADH at *9-1-501-661-2136* and verbally provide the information from 1903.011AA.

Time:

IF ADH cannot be contacted by phone, T-HEN contact DEM by phone at *9-1-501

=-0-9750* or by radio (Channel 6 unscrambled) and request them to relay notification to ADH.

3.IF ADH cannot be contacted by phone, T-HEN contact DEM by phone at *9-1-501 7-9750*

or by radio (Channel 6 unscrambled) and request them to relay notification to ADH.

4.Perform Att.

11, step 4 5.None 6.Use commercial phone at *9-1-301-816 5100* to transmit information from NRC Form 361 to NRC.

Person Contacted T i me COURTESY CALL NOTIFICATION CHECKLIST I FORM NO.

tv.

I 1903.

D 02-0.

1903.011 DD 026 i

--4.................

Date:

m

Page 50 of 74 7.Fax NRC Form 361 to the NRC Operations 1 7.None Center at *9-1-301-816-5151*.

Actions performed by:

name Page 2 of 2 (da t-e)

(time)

NOTE rvt nomtOn The material contained within the symbolsT-q".s proprietary or private information.

Upon termination of event, copies of Notification Forms, Checklists and other related documentation should be forwarded to Emergency Planning.

originals should be submitted to ANO records.

S MORM NO.

RV FORM TITLE:

COURTESY CALL NOTIFICATION CHECKLIST 1903.011 DD 026-04-0

ATTACHMENT 5 ALTERNATE ERO NOTIFICATION SCHEME This attachment is meant to provide guidance for notification to the Emergency Response Organization if:

A.

An Alert or higher emergency class is declared, AND B.

The Computerized Notifications System is out-of-service.

1.0 As directed by the person in Emergency Direction and Control, the communicator will initiate notifications to the ERO.

1.1 Use the 'All Call' pager number from the Emergency Telephone Directory or the Emergency ResponseDut Roster to access all of the ERO pagers.

1.2 Transmit the numenc message of '1111 for Unit 1 ("333" for Unit 1 drill) or '2222. for nit 2 ("444" for Unit2 drill) by pressing the numbers on a touch-tone phone keypad.

2.0 Further botification responsibilities are denoted by Figure 1.

3.0 Each person who staffs an ERO position shall implement tasks in accordance with applicable Emergency Response Facility Procedures 1903.064 - 1903,067.

FIGURE 1 I

siIrr

Page 1 of 4 ATTACHMENT 6 PROTECTIVE ACTION RECOMMENDATIONS (PAR)

FOR GENERAL EMERGENCY This flowchart is to be used as a guide for determining PAR's.

Actual PAR's are listed on the following pages of Attachment 6.

Re-evaluate PAR recommendations whenever plant conditions or radiological conditions change.

PROC.IWORK PLAN NO.

PROCEDUREIWORK PLAN TTLE:

PAGE:

53 of 74 1903.011 EMERGENCY RESPONSE/NOTIFICATIONS CHANGE:

026-04-0 Page 2, of 4 ATTACHMENT 6 PROTECTIVE ACTION RECOMMENDATIONS (PAR)

FOR GENERAL EMERGENCY PAR No.

1 IF plant conditions meet the following criteria:

  • General Emergency declared
THEN, recommend evacuating a 2 mile radius and 5 miles downwind, and sheltering the remainder of the 10 mile EPZ.

Determine the affected zones for the PAR from the chart given below.

Wind Direction Evacuate Zones Shelter Zones (from) 348.75 to 11.25 G U Remainder of EPZ 11.25 to 33.75 G R U Remainder of EPZ 33.75 to 56.25 G R U Remainder of EPZ 56.25 to 78.75 G R U Remainder of EPZ 78.75 to 101.25 G N 0 R Remainder of EPZ 101.25 to 123.75 G N 0 R Remainder of EPZ 123.75 to 146.25 G K N 0 Remainder of EPZ 146.25 to 168.75 G K N 0 Remainder of EPZ 168.75 to 191.25 G K N

.Remainder of EPZ 191.25 to 213.75 G K Remainder of EPZ 213.75 to 236.25 G K Remainder of EPZ 236.25 to 258.75 G H K Remainder of EPZ 258.75 to 281.25 G H K Remainder of EPZ 281.25 to 303.75 G H K U Remainder of EPZ 303.75 to 326.25 G H U Remainder of EPZ 326.25 to 348.75 G H U Remainder of EPZ IF there is a radiological release associated with this

event, THEN combine PAR 1 with applicable zones of PAR 3.

IROC.IWORK PLAN NO.

PROCEDUREIWORK PLAN TITLE:

pAGE:

54 of 74 1903.011 EMERGENCY RESPONSEINOTIFICATIONS CHANGE:

026-04-0 Page 3 of 4 ATTACHMENT 6 PROTECTIVE ACTION RECOMMENDATIONS (PAR)

FOR GENERAL EMERGENCY PAR No.

2 IF plant conditions meet the following criteria:

General Emergency declared AND 10% Fuel Clad Failure (actual or projected)*

AND 0

LOCA in progress OR Containment Atmosphere sample results indicate large amounts of fission products present; AND Containment failure is projected OR Radiological release is in progress

THEN, recommend evacuating a 5 mile radius and 10 miles downwind.

Recommend sheltering a--fected zones which cannot be evacuated prior to plume arrival (if known) and the remainder of the 10 mile EPZ.

Determine the affected zones for the PAR from the chart given below.

Wind Direction Evacuate Zones Shelter Zones (from) 348.75 to 11.25 G H K N 0 R S T U Remainder of EPZ 11.25 to 33.75 G H K N 0 Q R S U Remainder of EPZ 33.75 to 56.25 G H K N 0 Q R S U Remainder of EPZ 56.25 to 78.75 G H K N 0 Q R S U Remainder of EPZ 78.75 to 101.25 G H K N 0 P Q R U Remainder of EPZ 101.25 to 123.75 G H K N O P Q R U Remainder of EPZ 1235.75 to 146.25 G H K M N 0 P R U Remainder of EPZ 2814.25 to 303.75 G H IK K N 0P R U Remainder of EPZ 338.75 to 326.25 G H KMN ORU Remainder of EPZ 126.25 to 138.75 G H K M N 0 R R U Remainder of EPZ T

c16.75 to PAR

.25 G H a

bK zn M N PR U

Remainder of EPZ obtained fo Reacto G.r of EPZ 81.5 GH IJ KL NO RU Rmaiderof EPZ 1fe 1.25 to A

(3.75 G H ( U n N 0 R U Remainder of EPZ S

303.75 to 326.25 G H I J K N 0 R S T U

-Remainder of EPZ S326.25 to

.348.75 G H I K N 0 R S T U Remainder of EPZ IF there is a radiological release associated with this

event, TF-HEN combine PAR 2 with applicable zones of PAR 3.

NOTE Data from Attachment 7 and Attachment 8 may be more current than information obtained from Reactor Engineering.

  • Refer to Att.

7 (Unit 1) or Att.

8 (Unit 2) 2R if available, obtain an assessment of cor damage from Reactor Engineering.

Use available trend data when assessing the potential for >10% Fuel Clad Failure.

PROCJWORK PLAN NO.

PROCEDURE/WORK PLAN TITLE:

1903.011 EMERGENCY RES PONSE/NOTIFICATIONS ATTACHMENT 6 PROTECTIVE ACTION RECOMMENDATIONS (PAR)

FOR GENERAL EMERGENCY PAR No.

3 IF plant conditions meet the following criteria:

0 General Emergency declared AND 0

EPA Protective Action Guidelines are projected to be exceeded.

1 Rem TEDE OR 5 Rem Child Thyroid CDE THEN give the following Protective Action Recommendation.

EVACUATE:

  • Zones projected to exceed the EPA Protective Action Guidelines (obtain from dose assessment)

AND Zones from PAR 1 or PAR 2 (dependent upon plant conditions).

SHELTER:

Remainder of the 10 mile EPZ

  • Dose assessment PAR's will be initially provided by the Initial Dose Assessor in the Control Room.

When the Dose Assessment Team becomes operational in the EOF, the Dose Assessment team will provide this information.

PAGE:

55 of 74 CHANGE:

026-04-0 Page 4 of 4

PROC.IWORK PLAN NO.

PROCEDUREIWORK PLAN TITLE:

PAGE 56 of 74 1903.011 EMERGENCY RESPONSEINOTIFICATIONS CHANGE:

026-04-0 ATTACHMENT 7 Page 1 of 4 CORE FUEL DAMAGE ASSESSMENT UNIT 1 1.0 Determine the average power for the unit for the last 30 days.

Average Power =

k 2.0 Determine Fuel Factor Fuel

=

100%

+ Average Power Factor NOTE Fuel damage determinations based on the containment radiation monitors assumes a minimum of 30 days at 100 percent power.

The corrected R/hr will correct monitor readings in the event the unit has not run at 100 percent for the required time.

CAUTION In the absence of a significant containment temperature transient, Fonitor readings should be considered valid.

  • In the event of a significant containment temperature transient, monitor readings may be erratic for a short duration (Ref.IN 4 5, Supplement 1) 3.0 Determine corrected containment radiation level from the following monitors:

3.1 RE-8060 R/hr x Fuel Factor (from step 2) 3.2 RE-8061 R/hr x Fuel Factor (from step 2) 4.0 Determine hours since shutdown.

NOTE Graphs 1 and 2 are listed in tabular data form on page 4 of 4 as an aid in this attachment.

5.0 IF containment spray IS in operation, T-HEN use graph, page 2 of 4, or Table 1, page 4 of 4, of this attachment to determine fuel damage.

6.0 IF containment spray IS NOT in operation, THEN use graph, page 3 of 4, or Table 2, page 4 of 4, of this attachment to determine fuel damage.

'ATTACHMENT 7

Page 2 of 4 ANO-1 Radiation Monitor (RE-8060, RE-8061) Readings WITH Containment Spray CF = Clad Failure, FO = Fuel Overheat 1.OOE+06 1.OOE+05 1.OOE+04 XX A

A 1.00E+03

_,+

+

1.OOE+02 1.OOE+01 1.OOE+00 0

2 4

6 8

10 12 14 16 18 20 22 24 Time after Shutdown (hrs) lCF

+16% CF -x-50% CF 100% CF

-50/

FO

--o--1% CF x--0 C

--x 50% CF 100% CF -.-

50% FO -

-100% FO 0

0

ATTACHMENT 7 ANO-1 Radiation Monitor (RE-8060, RE-8061) Readings Containment Spray WITHOUT CF = Clad Failure, FO = Fuel Overheat 1.00E+06 I.OOE'-05 1.O0E+04 X

X

-x x

1.OOE+03 1.OOE+02 1.OOE+01 1.0E+0

.0 0

2 4

6 8

10 12 14 16 18 20 22 2

Time after Shutdown (hrs) -l%

CF -+-1O% CF -x-50% CF 6

100% CF -ý0---

50% FO -+--100% FO

.4 1Z 0 0 0*

Page 3 of 4

ATTACHMENT 7 Page 4 of 4 Table 1 ANO-1 Dose Rates vs Time WITH Containment Spray 1% CF 283.0 166.5 102.3 42.3 34.7 27.2 19.8 13.6 9.6 6.0 10% CF 2829.8 1665.0 1023.3 423.0 347.3 272.3 198.4 136.0 95.6 60.2 50% CF 100% CF 14149.1 8325.2 5116.3 2114.9 1736.6 1361.4 992.2 679.8 477.8 301.2 28298.2 16650.5 10232.6 4229.9 3473.2 2722.8 1984.3 1359.6 955.7 602.5 50% FO 100% FO 456280.0 178433.2 109331.2 37576.9 25217.3 18789.8 14380.5 10674.4 7539.0 4843.1 912560.0 356866.4 218662.4 75153.8 50434.6 37579.5 28761.0\\

21348.8 15077.9 9686.2 Table 2 ANO-1 Dose Rates vs Time WITHOUT Containment Spray TIME 0.0 0.5 1.0 3.0 6.0 12.0 24.0 48.0 96.0 192. 0 1% CF 283.0 258.7 237.6 185.9 149.6 114.4 82.5 57.4 40.2 26.5 10% CF 2829.8 2587.0 2376.3 1858.6 1496.0 1144. 1 824.8 574.1 401.8 264.5 50% CF 100% CF Time is in hours since shutdown DOSE RATES are in R/hr CF is Clad Failure Incident FO is Fuel Overheat Incident TIME 0.0 0.5 1.0 3.0 6.0 12.0 24.0 48.0 96.0 192. 0 14149.1 12935.1 11881.3 9293.2 7480.0 5720.4 4123.9 2870.3 2009.1 1322.7 28298.2 25870.2 23762.6 18586.5 14960.0 11440.9 8247.8 5740.7 4018.2 2645.5 50% FO 456280.0 228527.2 182265.6 107276.4 78861.2 61978.4 47418.8 34471.4

,22469.0 11713.7 100% FO 912560.0 457054.4 364531.2 214552.8 157722.4 123956.8 94837.6 68942.7 44938.1 23427.4

PROC.1WORK PLAN NO.

PROCEDUREIWORK PLAN TITLE:

1903.011 EMERGENCY RES PONSE/NOTII PAGE:

60 of 74 CHANGE:

026-04-0 ATTACHMENT 8 Page 1 of 4 CORE FUEL DAMAGE ASSESSMENT UNIT-2 1.0 Determine the average power for the unit for the last 30 days.

Average Power =

2.0 Determine Fuel Factor Fuel Factor

=

100%

+ Average Power NOTE Fuel damage determinations based on the containment radiation monitors assumes a minimum of 30 days at 100 percent power.

The corrected R/hr will correct monitor readings in the event the unit has not run at 100 percent for the required time.

3.0 Determine corrected containment radiation level from the following monitors:

3.1 2RY-8925-1 R/hr x Fuel Factor (from step 2) 3.2 2RY-8925-2 R/hr x Fuel Factor (from step 2) 4.0 Determine hours since shutdown.

5.0 IF containment spray IS in operation, THEN use graph, page 2-of 4, or Table 1, page 4of 4, of this attachment to determine fuel damage.

6.0 IF containment spray IS NOT in operation, T-HEN use graph, page 3 of 4, or Table 2, page 4 of 4, of this attachment to determine fuel damage.

CAUTION In the absence of a significant containment temperature transient, monitor readings should be considered valid.

In the event of a significant containment temperature transient, monitor readings may be erratic for a short duration (Ref.IN-97-4 5, Supplement 1) iiE Page I of 4

PROC.JWORK PLAN NO.

PROCEDUREIWORK PLAN TITLE:

1903.011 EMERGENCY RESP PAGE:

61 of 74 CHANGE:

026-04-0 ONSE/NOTIFICATIONS ATTACHMENT 8 Page 2 of 4 ANO-2 Radiation Monitor (2RY-8925-1, 2RY-8925-2) Readings WITH Containment Spray CF = Clad Failure, FO = Fuel Overheat 1.OOE+07 1.OOE-06 1.OOE+05 O.

1.00E+04 x

X-ýX 1.OOE+03

+

1.OOE+02 1.OOEI-01 1.00E+001 1I OOE FO 0O i..

0 2

4 6

8 10 12 14 16 18 20 22 24 Time after Shutdown (hrs) 1--l%

CF -+-19% CF -x-50% CF -

1---100% CF -*---50% FO --

100o% FO a)

(U 0

ATTACHMENT 8 Page 3 of 4 ANO-2 Radiation Monitor (2RY-8925-1, 2RY-8925-2) Readings WITHOUT Containment Spray CF = Clad Failure, FO = Fuel Overheat I.~VL U'

I 0

2 4

6 8

10 12 14 16 18 20 22 24 Time after Shutdown (hrs)

.--o-1% CF -+-10% CF -x-50% CF A 100% CF --o-50% FO --a100% FO 1.OOE+07 1.OOE+06 1.OOE+05 1.OOE+04 1.OOE+03 1.OOE+02 1.OOE+01 "I."

0) 0 a

4 nn *-..Lnn

PROC./WORK PLAN NO.

PROCEDURE/WORK PLAN TITLE:

1903.011 EMERGENCY RES PONSEINOTIFICATIONS ATTACHMENT 8 Page 4 of 4 Table 1 ANO-2 Dose Rates vs Time WITH Containment Spray 1% CF 321.6 189.2 116.3 48.1 39.5 30.9 22.5 15.5 10.9 6.8 10% CF 3215.7 1892.1 1162.8 480.7 394.7 309.4 225.5 154.5 108.6 68.5 50% CF 100% CF 16078.5 9460.5 5814.0 2403.4 1973.4 1547.1 1127.5 772.5 543.0 342.3 32157.0 18921.0 11628.0 4806.7 3946.8 3094.1 2254.9 1545.0 1086.0 684.6 50% FO 100% FO 518500.0 202765.0 124240.0 42701.0 28656.0 21352.0 16341.5 12130.0 8567.0 5503.5 1037000.0 405530.0 248480.0 85402.0 57312.0 42704.0 32683.0 24260.0 17134.0 11007.0 Table 2 ANO-2 Dose Rates vs Time WITHOUT Containment Spray TIME 0.0 0.5 1.0 3.0 6.0 12.0 24.0 48.0 96.0 192.0 1% CF 321.6 294.0 270.0 211.2 170.0 130.0 93.7 65.2 45.7 30.1 10% CF 3215.7 2939.8 2700.3 2112.1 1700.0 1300.1 937.3 652.4 456.6 300.6 50% CF 100% CF 16078.5 14699.0 13501.5 10560.5 8500.0 6500.5 4686.3 3261.8 2283.1 1503.1 32157.0 29398.0 27003.0 21121.0 17000.0 13001.0 9372.5 6523.5 4566.1 3006.2 50% FO 100% FO 518500.0 1037000.0 259690.0 519380.0 207120.0 414240.0 121905.0 243810.0 89615.0 179230.0 70430.0 140860.0 53885.0 107770.0 39172.0 78344.0 25533.0 51066.0 13311.0 26622.0 Time is in hours since shutdown DOSE RATES are in R/hr CF is Clad Failure Incident FO is Fuel Overheat Incident TIME 0.0 0.5 1.0 3.0 6.0 12.0 24.0 48.0 96.0 192.0 PAGE:

63of 74 CHANGE:

026-04-0

PROC.WORK PLAN NO.

PROCEDURE/WORK PLAN TITLE:

1903.011 EMERGENCY RESPONSEINOTIFICATIONS Sect; Sect Sect Sect Sect Sect Sect

[ATTACHMENT 9]

[Computerized Notification System (CNS)

Instructions]

ion 1:

Emergency Class Notification Using the CNS ion 2:

Post-trip Notification Using the CNS ion 3:

Non-Emergency/Off-Normal Notification Using the CNS ion 4:

Confirming CNS Operation ion 5:

Stopping a Scenario ion 6:

Returning the CNS to Standby ion 7:

Emergency Class Notification Backup Method (Telephone)

NOTE Upon loss of. off-site power, Unit 2 would have to start CNS from the Unit 1 Terminal.

Section 1 Emergency

1.
2.
3.
4.
5.
6.
7.
8.
9.
10.

11.

12.

Class Notification Using the CNS IF CNS fails to activate for any reason while performing the following steps, I N

f THEN immediately implement section 7, "Emergency Class Notification Backup Method (Telephone)" of this attachment.

The CNS terminal has an automatic screen-blanking feature.

If the screen is blank, press any key to restore the screen.

Turn up the contrast or brightness if necessary.

At the Application: Communicator: Password Entry screen, type "0002".

Press [Enter].

At the Application: Communicator: Main Menu screen, highlight "Execution" using the right or left arrow keys.

Press [Enter].

using the up or down arrow keys, highlight "Scenario Control".

Press (Enter].

At the Application: Communicator: Scenario Activation Control screen, highlight the appropriate scenario using the up or down arrow keys.

Press [Enter].

A list of options will appear.

Using the up or down arrow keys, highlighlt'the option "Start this scenario".

Press [Enter).

PAGE:

64 of 74 CHANGE:

026-04-0 Page 1 of 7

ROCJWORK PLAN NO.

PROCEDURE/WORK PLAN TITLE:

1903.011 EMERGENCY RESPONSE/NOTIFICATIONS

[ATTACHMNT 9]

(Section 1 Cont.)

13.

At the prompt "Confirm Scenario start?

(Y/N):

N

", enter "Y".

14.

Press [Enter] to start the scenario.

15.

Observe the Application: Communicator: Scenario Activation Control' screen.

Check that the scenario status changes to "Active".

16.

The scenario will run until all positions are filled, the scenario.

duration elapses or it is stopped by the operator.

17.

If you want to confirm CNS operation, go to Section 4 of this attachment.

Section 2 Post-Trip Notification Using the CNS NOTE The CNS terminal has an automatic screen-blanking feature.

If the screen is blank, press any key to restore the screen.

1.

At the Application: Communicator: Password Entry screen, type "0002".

2.

Press [Enter).

3.

At the Application: Communicator: Main Menu screen, highlight "Execution" using the right or left arrow keys.

4.

Press [Enter].

5.

Using the up or down arrow keys, highlight "Scenario Control".

6.

Press [Enter].

7.

At the Application: Communicator: Scenario Activation Control screen, highlight the appropriate scenario using the up or down arrow keys.

8.

Press [Enter].

9.

A list of options will appear.

Using the up or down arrow keys, highlight the option "Start this scenario".

i0.

Press [Enter).

PAGE:

65 of 74 CHANGE:

026-04-0 Page 2.of 7

PROC./WORK PLAN NO.

PROCEDURE/WORK PLAN TITLE:

1903.011 EMERGENCY RESPONSEINOTIFICATIONS (Se PAGE:

66 of 74 CHANGE:

026-04-0 Page 3 of 7

[ATTACHMENT 9]

ction 2 Cont.)

II.

At the prompt "Confirm scenario start?

(Y/N):

N

," enter" "Y".

12.

Press [Enter] to start the scenario.

13.

Observe the Application: Communicator: Scenario Activation Control Screen.

Check that the scenario status changes to "Active."

14.

The scenario will run until all positions are filled, the scenario duration elapses or it is stopped by the operator.

-M r ration.

ao to Section 4 of this attachment.

Section 3 Non-Emergency/Off-Normal Notification Using the CNS NOTE The CNS terminal has an automatic screen-blanking feature.

If the screen is blank press any key to restore the screen.

NOTE You must use the phone to start the scenarios covered by this section.

1. Dial 3683 from any touch-tone phone.

While the system is speaking the "Hello" segment, enter 0002 followed by the pound sign (#)

2.

You will hear, "Enter your scenario number followed by the pound sign."

3.

Enter the scenario number (100 for Unit 1 or 200 for Unit 2) followed by the pound sign (#).

4.

You will hear, "You entered (scenario number).

Is that correct?

Press 9 for YES or 6 for NO."

5.

Press 9 for YES or 6 for NO.

If you press 9 the system will continue scenario activation.

If you press 6 the system will repeat the prompt for the scenario number.

6.

After pressing 9 for YES you will hear, "The scenario will be queued as a(n)

(Emergency, Drill, or Test).

When you are ready to record your message, please press the star and the pound keys on your phone."

7.

When you are ready to record your message, press the star (*)

and the pound

(#)

keys.

8.

You will hear, "Record your message at the tone.

Push the pound key when you are finished."

9.

Record the message.

Press [#] when you are done.

10. You will hear, "You said...

(the system will speak your recorded message).

Is that correct?

Press 9 for YES or 6 for NO."

-w

PROCJWORK PLAN NO.

PROCEDURE/WORK PLAN TITLE:

PAGE:

67 of 74 1903.011 EMERGENCY RESPONSEINOTIFICATIONS CHANGE:

026-04-0 Page 4 of 7

[ATTACHMENT 9]

(Section 3 Cont.)

11. If you press 9 for YES the system will continue scenario activation.

If you press 6 for NO the system will repeat the prompt to record the message.

12.

After pressing 9 for YES you will hear, "Your selected scenario, (scenario number) will now be sent.

Are you sure this is what you want to do?

Press 9 for YES or 6 for NO."

13.

If you press 9 for YES the system will continue scenario activation.

If you press 6 for NO you will hear, "Thank you.

Goodbye."

The system will end the call without starting the scenario.

14.

After pressing 9 for YES, you will hear, "Thank you.

Goodbye."

The system will end the call and start the scenario.

15.

Any further scenario control functions must be performed at the keyboard.

16.

If you want to confirm CNS operation, go to Section 4 of this attachment.

Section 4 Confirming CNS Operation Using the Scenario Monitor:

1.

IF you are at the Application: Communicator: Scenario Activation Control screen, THEN perform the following

a.

Press [Esc)

b.

Go to step 6.

2.

At the Application: Communicator: Password Entry screen enter '0002'.

3.

Press [Enter].

4.

At the Application: Communicator: Main Menu screen highlight "Execution" using the'left or right arrow keys.

S.

Press (Enter].

6.

Highlight "Scenario Monitor" using the up or down arrow keys.

7.

Press [Enter].

8.

The Scenario Monitor will show the status of the scenario that is currently running or that has most recently been run.

9.

Observe the Scenario Monitor screen.

Check that the system is attempting to contact personnel.

10.

Press [Esd] to exit the Scenario Monitor.

PROC./WORK PLAN NO.

PROCEDUREIWORK PLAN TITLE:

PAGE:

68 of 74 1903.011 EMERGENCY RESPONSEINOTIFICATIONS CHANGE:

026-04-0 Page 5 of 7

[ATTACHMENT 9]

(Section 4 Cont.)

Using the Reports

1.

The system will print a report every 5 minutes.

2.

Check the reports to see that personnel are responding to the CNS.

Using the Status Screen:

1.

At any screen press [Ctrl 2].

You must use the number pad.

2.

The Status Screen will show the phone lines.

3.

Observe the Status screen.

Check that the system is making and receiving calls.

4.

Press [Ctrl 1) (using the number pad) to return to the system operation screens.

Section 5 Stopping a Scenario

1. At the Application: Communicator: Main Menu screen, highlight "Scenario Control" (if not already highlighted) using the up or down arrows.
2.

Press [Enter].

3. Using the up or down arrow keys, highlight the scenario to be stopped.
4. Press [Enter].
5. A list options will appear.

Highlight the option "Stop this scenario."

6.

Press [Enter].

7.

At the prompt "Confirm scenario stop?

(YIN): N " enter "Y".

8.

Press [Enter].

9.

Observe the Application: Communicator: Scenario Activation Control screen.

Check that the scenario status changes to "Completed".

Section 6 Returning the CNS to Standby

1. Press [Esc] as many times as necessary to return to the Application:

Communicator: Main Menu.

2.

At the Application: Communicator: Main Menu highlight "Exit" using the left or right arrow keys.

3.

Press [Enter].

PROCJWORK PLAN NO.

PROCEDUREIWORK PLAN TITLE:

1903.011 EMERGENCY RES PONSE/NOTIFICATIONS

[ATTACHMENT 9]

(Section 6 Cont.)

4.

At the prompt "Exit to system" press [Enter].

5.

The system should return to the Application: Communicator: Password Entry screen.

Section 7

Emergency Class Notification Backup Method (Telephone)

For NUE Notifications NOTE The following positions will be notified of an NUE:

EOF Director TSC Director Vice President, Operations General Manager, Plant Operations Unit 1 and 2 Plant Managers Unit 1 and 2 Operations Managers Communications Manager NRC Resident Inspector CEC Manager Duty Emergency Planner

1.

Dial *9-964-1644*

2.

When asked for password, enter "11234".

3.

When asked for the phone number, enter "0001" for a Unit 1 event OR

",,0002" for a Unit 2 event.

i71II PAGE:

69 of 74 CHANGE:

026-04-0 Page 6 of 7 7

Momm

PROC.IWORK PLAN NO.

PROCEDUREIWORK PLAN TITLE:

1903.011 EMERGENCY RESPONSE/NOTIFICATIONS page 7 of 7

[ATTACHMENT 9]

For ALERT or higher Notifications:

1.

Dial *9-964-1645*

A.

When asked for password, enter "1234".

B.

When asked for the phone number, enter "IIII" (for drills enter

",,333") for a Unit 1 event OR

",'2222" (for drills enter "444") for a Unit 2 event.

2.

Dial *9-964-6411*

A.

When asked for password, enter "1234".

B.

When asked for the phone number, enter "1111" (for drills enter "333")

for a Unit 1 event OR "2222" (for drills enter "444") for a Unit 2 event.

PAGE:

70 of 74 CHANGE:

026-04-0

PROC.WORK PLAN NO.

PROCEDUREIWORK PLAN TTLE:

PAGE:

71 of 74 1903.011 EMERGENCY RESPONSEINOTIFICATIONS CHANGE:

026-04E ATTACHMENT 10 Page I1 of 3 Emergency Class Notification Instructions AUTHENTICATION If challenged by the Arkansas Department of Health (ADH) or the Department of Emergency Management (DEM) communicator to identify yourself, use the DEM Emergency Action Authenticator to provide the proper two-digit response.

TIME REQUIREMENTS 4,

Emergency Class Declaration:

The ADH shall be notified within 15 minutes of an emergency class declaration, change (upgrade or downgrade),

or termination.

A Follow-up Notification to the ADH is required within approximately 30 minutes after an Initial Notification.

A Follow-up Notification is required within one hour after the previous Follow-up Notification.

The Nuclear Regulatory Commission (NRC) shall be notified immediately after notification of the ADH and NOT later than one hour following the declaration of an emergency class.

Courtesy Calls:

The ADH shall be notified as soon as practical but no later than four hours following the event.

The NRC shall be notified immediately following the ADH but no later than four hours following the event.

INSTRUCTIONS Form 1903.011Y, "Emergency Class Initial Notification Message":

1.

Number messages sequentially from the initial notification at the beginning of the event to the event termination message.

2.

Wind speed and direction are obtained from the RDACS System Status screen (preferred), chart recorders in the Unit 1 Control Room, or the Dardanelle Dam Control Room.

Protective Action Recommendations (PARs) are obtained from the person with Emergency Direction and Control.

Self-explanatory.

3.

PROC.IWORK PLAN NO.

PROCEDURE/NORK PLAN TITLE:

PAGE:

72 of 74 1903.011 EMERGENCY RESPONSE/NOTIFICATIONS CHANGE:

026-04-0 ATTACHMENT 10 Page 2 of 3 Form 1903.011Z, "Emergency Class Follow-up Notification Message".

1.

Number messages sequentially from the initial notification at the beginning of the event to the event termination message.

2.

Name of person making notifications and the telephone number where they can be reached by offsite agencies.

3.

Check appropriate box for the event.

4.

Check the appropriate emergency classification or termination message.

5.

Check the appropriate box designating the unit the event was declared on.

Enter the date and time that the emergency class was declared.

6.

Request from the person with Emergency Direction and Control the prognosis of the plant.

7.

Protective Action Recommendations (PARs) are obtained from the person with Emergency Direction and Control.

8.

Enter the correct EAL for which the Emergency Class declaration was declared.

Enter the description of the EAL.

Additional comments may be entered (i.e. other applicable EAL's, plant status, power level).

9.

Check appropriate box for reactor condition.

Enter date and time of if reactor is shutdown.

i0.

Enter a brief status of the other unit.

This should include, but is not limited to, power level (if operating),

shutdown status, emergency classes, etc.

ii.

Wind speed and direction are obtained from the RDACS System Status screen (preferred), chart recorders in the Unit 1 Control Room, or the Dardanelle Dam Control Room.

Stability Class is obtained from the RDACS System Status screen (preferred) or Dose Assessment personnel.

PROC.IWORK PLAN NO.

PROCEDURE/WORK PLAN TITLE.

PAGE*

73 of 74 1903.011 EMERGENCY RESPONSE/NOTIFICATIONS CHANGE:

026-04-0 ATTACHMENT 10 Page 3 of 3

12.

A Gaseous Radioactive Release exceeding federally approved operating limits is equivalent to a radiological NUE or higher emergency class.

If a radiological release is occurring, the expected duration is obtained from the Shift Manager or the TSC Director.

Gaseous Release Rates may be obtained from Dose Assessment or from the RDACS report, Plume Segment Data section, page 1 of 2.

The estimate of projected off-site dose may be obtained from the Dose Assessment Supervisor, the REAM or from the PAR report (PAR Report is printed separately from the RDACS report).

13.

Liquid release information may be obtained from the Dose Assessment Supervisor, REAM or Chemistry.

14.

Must be approved by person with Emergency Direction and Control.

77777ý

ATTACHMENT 11 Non-Emergency Notifications of Off-Normal Events When directed by the Shift Manager to complete this attachment, perform the following steps:

I.

For Courtesy Calls and other Non-Emergency/Off-Normal Events, activate the appropriate.Non-Emergency/Off-Normal Event" scenario using the Computerized Notification System" (CNS) to notify designated Entergy management and the NRC Resident Inspector.

Refer to CNS instructions on Attachment 9, Section 3.

2.

Monitor CNS to ensure it is functioning properly and review reports generated by CNS.

3.

IF CNS fails, THEN provide notification to the following Entergy and NRC representatives via telephone.

You should attempt to notify all of the representatives listed below.

Some individuals may be unavailable,; however, this is a courtesy notification for information only and not a requirement:

Operations Manager of the affected unit(s)

Plant Manager of the affected unit(s)

General Manager Plant Operations Vice President, Operations EOF Director TSC Director NRC Resident Inspector Communications Manager CEC Manager Duty Emergency Planner If this method is used, document successful contacts in the station log.

4.

Report to the Shift Manager when the above actions have been completed.