Annual Occupational Exposure Reports for Nine Mile Point Nuclear Station, Units 1 and 2
ML021050032
Person / Time
Site: Nine Mile Point  
Issue date: 03/22/2002
From: Conway J
Constellation Nuclear
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NMP1L 1642
Download: ML021050032 (5)


Text

P.O. Box 63 Lycorning, New York 13093 Constellation Nuclear Nine Mile Point March 22, 2002 Nuclear Station N

1642 A Member of the Constellation Energy Group U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 RE:

Nine Mile Point Unit 1 Nine Mile Point Unit 2 Docket No. 50-220 Docket No. 50-410 DPR-63 NPF-69

Subject:

Annual Occupational Exposure Reports for Nine Mile Point Nuclear Station Unit 1 and Unit 2 Gentlemen:

Nine Mile Point Nuclear Station, LLC is submitting the Annual Occupational Exposure Reports for the Nine Mile Point Nuclear Station Unit 1 and Unit 2, in accordance with Unit 1 Technical Specification (TS) 6.9.1.b and Unit 2 Improved Technical Specification 5.6.1, respectively. These reports are enclosed as Attachments 1A and 1B for Unit 1, and Attachments 2A and 2B for Unit 2. They incorporate the guidance of NRC Regulatory Guide 1.16 (Revision 4), and cover the period January 1, 2001 through December 31, 2001.

Please refer any questions regarding these reports to Mr. David Barcomb, Unit 2 Radiation Protection Manager, at (315) 349-4217.

Sincerely,

~hn T.Conway Site Vice President JTC/IAA/cld Attachments xc:

Mr. H. J. Miller, Regional Administrator, Region I Mr. G. K. Hunegs, Senior Resident Inspector Mr. P.S. Tam, Senior Project Manager, NRR (2 copies)

Records Management ij165('

ATTACHMENT 1A Nine Mile Point Nuclear Station Unit # 1 DPR-63 2001 Regulatory Guide 1.16 Report Numbers of Personnel > 100 mrem Exposure Totals (mrem)

Work & Job Function Station Utility Contract Total Station Utility Contract Total Employees Employees

& Others Employees Employees Employees

& Others mili-Rems Reactor Operations & Surv.

Maintenance Personnel 0

0 8

8 0

0 147 147 Operating Personnel 51 1

1 53 5,883 13 106 6,002 Health Physics Personnel 4

0 0

4 26 0

0 26 Engineering Personnel 2

0 0

2 35 0

0 35 Supervisory Personnel 0

0 0

0 0

0 0

0 Total 57 1

9 67 5,944 13 253 6,210 Routine Maintenance Maintenance Personnel 111 0

322 433 30,932 0

81,279 112,211 Operating Personnel 50 0

2 52 11,010 0

8 11,018 Health Physics Personnel 46 0

13 59 13,081 0

4,196 17,277 Engineering Personnel 20 0

23 43 2,576 0

3,530 6,106 Supervisory Personnel 11 0

9 20 2,892 0

816 3,708 Total 238 0

369 607 60,491 0

89,829 150,320 In-Service Inspection Maintenance Personnel 7

0 138 145 36 0

26,796 26,832 Operating Personnel 4

0 0

4 36 0

0 36 Health Physics Personnel 4

0 4

8 9

0 115 124 Engineering Personnel 6

0 15 21 259 0

3,877 4,136 Supervisory Personnel 0

0 2

2 0

0 522 522 Total 21 0

159 180 340 0

31,310 31,650 Special Maintenance Maintenance Personnel 45 0

202 247 3,106 0

35,337 38,443 Operating Personnel 23 0

0 23 390 0

0 390 Health Physics Personnel 15 0

2 17 352 0

148 500 Engineering Personnel 4

0 11 15 134 0

1,416 1,550 Supervisory Personnel 5

0 5

10 363 0

1,169 1,532 Total 92 0

220 312 4,345 0

38,070 42,415 Waste Processing Maintenance Personnel 0

0 0

0 0

0 0

0 Operating Personnel 8

0 2

10 3,309 0

471 3,780 Health Physics Personnel 16 0

1 17 613 0

22 635 Engineering Personnel 0

0 0

0 0

0 0

0 Supervisory Personnel 2

0 0

2 45 0

0 45 Total 26 0

3 29 3,967 0

493 4,460 Refueling Maintenance Personnel 11 0

40 51 122 0

4,757 4,879 Operating Personnel 3

0 0

3 12 0

0 12 Health Physics Personnel 8

0 2

10 347 0

102 449 Engineering Personnel 3

0 5

8 97 0

167 264 Supervisory Personnel 1

0 1

2 9

0 108 117 Total 26 0

48 74 587 0

5,134 5,721 Summary by Job Function Maintenance Personnel 174 0

710 884 34,196 0

148,316 182,512 Operating Personnel 139 1

5 145 20,640 13 585 21,238 Health Physics Personnel 93 0

22 115 14,428 0

4,583 19,011 Engineering Personnel 35 0

54 89 3,101 0

8,990 12,091 Supervisory Personnel 19 0

17 36 3,309 0

2,615 5,924 Grand Total 460 1

808 1,269 75,674 13 165,089 240,776 Note: Workers may be counted in more than one category. Exposure totals are rounded numbers.

ATTACHMENT 1B 2001 Nine Mile Point - Unit # 1 Description of Special Maintenance Activities Job Description CRD-1 06/108 Valve Replacement Modification Work Installation Of New Acoustic Valve Monitoring System Cable And Conduit Replace PRV-33-145 Modification Hydrogen Water Chemistry Installation Related Work in Reactor Water Clean Up Rooms MSIV-01-02 Repair/Modification IV-40-01/IV-40-10 Modification Ni 025 Installation of New Reactor Water Clean Up Vent and Drain Valves Replace IV-33-02R and Install New Valve Install Weld-O-Lets in Storage Pit Drain Line R15/R16 Sump Level Control Modification Vacuum Breaker Modification

ATTACHMENT 2A

.Nine Mile Point Nuclear Station Unit # 2 NPF-69 2001 Regulatory Guide 1.16 Report Numbers of Personnel > 100 mrem Exposure Totals (mrem)

Work & Job Function Station Utility Contract Total Station Utility Contract Total Employees Employees

& Others Employees Employees Employees

& Others mili-Rems Reactor Operations & Surv.

Maintenance Personnel 24 0

1 25 679 0

4 683 Operating Personnel 48 1

1 50 6,096 149 230 6,475 Health Physics Personnel 14 0

1 15 152 0

8 160 Engineering Personnel 2

0 0

2 4

0 0

4 Supervisory Personnel 2

0 0

2 6

0 0

6 Total 90 1

3 94 6,937 149 242 7,328 Routine Maintenance Maintenance Personnel 105 0

68 173 22,720 0

3,725 26,445 Operating Personnel 58 1

2 61 5,286 47 303 5,636 Health Physics Personnel 42 0

4 46 9,480 0

588 10,068 Engineering Personnel 17 0

4 21 1,275 0

655 1,930 Supervisory Personnel 10 0

1 11 816 0

43 859 Total 232 1

79 312 39,577 47 5,314 44,938 In-Service Inspection Maintenance Personnel 0

0 2

2 0

0 58 58 Operating Personnel 0

0 0

0 0

0 0

0 Health Physics Personnel 1

0 0

1 8

0 0

8 Engineering Personnel 1

0 0

1 22 0

0 22 Supervisory Personnel 0

0 0

0 0

0 0

0 Total 2

0 2

4 30 0

58 88 Special Maintenance Maintenance Personnel 61 0

30 91 5,879 0

1,919 7,798 Operating Personnel 11 0

0 11 133 0

0 133 Health Physics Personnel 11 0

0 11 405 0

0 405 Engineering Personnel 5

0 2

7 93 0

384 477 Supervisory Personnel 5

0 0

5 674 0

0 674 Total 93 0

32 125 7,184 0

2,303 9,487 Waste Processing Maintenance Personnel 25 0

8 33 843 0

764 1,607 Operating Personnel 19 0

1 20 1,674 0

483 2,157 Health Physics Personnel 18 0

3 21 1,397 0

30 1,427 Engineering Personnel 3

0 0

3 16 0

0 16 Supervisory Personnel 2

0 0

2 72 0

0 72 Total 67 0

12 79 4,002 0

1,277 5,279 Refueling Maintenance Personnel 17 0

7 24 374 0

20 394 Operating Personnel 0

0 0

0 0

0 0

0 Health Physics Personnel 5

0 0

5 29 0

0 29 Engineering Personnel 1

0 1

2 2

0 2

4 Supervisory Personnel 0

0 0

0 0

0 0

0 Total 23 0

8 31 405 0

22 427 Summary by Job Function Maintenance Personnel 232 0

116 348 30,495 0

6,490 36,985 Operating Personnel 136 2

4 142 13,189 196 1,016 14,401 Health Physics Personnel 91 0

8 99 11,471 0

626 12,097 Engineering Personnel 29 0

7 36 1,412 0

1,041 2,453 Supervisory Personnel 19 0

1 20 1,568 0

43 1,611 Grand Total 507 2

136 645 58,135 196 9,216 67,547 Note: Workers may be counted in more than one category. Exposure totals are rounded numbers.

ATTACHMENT 2B 2001 Nine Mile Point - Unit # 2 Description of Special Maintenance Activities Job Description Spent Fuel Pool Rack Expansion Project Install New Design Rotary Variable Differential Transmitter Coupling on 2RCS*HYV1 7A and 2RCS*HYV17B Install Backup Rotary Variable Differential Transmitter Position Indication Modification N2-97-081 on 2RCS*HYV1 7A and 2RCS*HYV1 7B Install Rotary Variable Differential Transmitter (RVDT) Temporary Vibration and Temperature Monitoring Instrumentation for 2RCS-HYV1 7A-RVDT and 2RCS-HYV1 7B-RVDT Install Rotary Variable Differential Transmitter Monitoring Camera at 2RCS*HYV17A and 2RCS*HYV1 7B Furmanite Repair 2MSS-AOV85A Install New Forward Viewing Camera On Refueling Bridge