April 2, 2002 MEMORANDUM TO:

Jack Rosenthal, Chief Safety Margins and Systems Analysis Branch FROM:

Gene Rhee

/RA/

Safety Margins and Systems Analysis Branch

SUBJECT:

PERMISSION TO ISSUE AN ANALYSIS REPORT ON PTS I would like to issue as our Branch document the attached draft report on the comparison between TRAC-M Version 3782 and RELAP5 Mod 3.2.2 Gamma calculations of selected pressurized thermal shock scenarios of the Oconee Unit 1 Plant. David Bessette reviewed the report, and his comments have been incorporated in the report. Please let me know as soon as possible whether I can proceed to issue it.

Attachment:

Draft Report on TRAC-M and RELAP5 Calculation Comparisons ADAMS ML020930525 Approved:

Signed Jack E. Rosenthal 04/02/02 APPROVED AS FINAL Jack Rosenthal, Chief, SMSAB Date

April 2, 2002 MEMORANDUM TO:

Jack Rosenthal, Chief Safety Margins and Systems Analysis Branch FROM:

Gene Rhee

/RA/

Safety Margins and Systems Analysis Branch

SUBJECT:

PERMISSION TO ISSUE AN ANALYSIS REPORT ON PTS I would like to issue as our Branch document the attached draft report on the comparison between TRAC-M Version 3782 and RELAP5 Mod 3.2.2 Gamma calculations of selected pressurized thermal shock scenarios of the Oconee Unit 1 Plant. David Bessette reviewed the report, and his comments have been incorporated in the report. Please let me know as soon as possible whether I can proceed to issue it.

Attachment:

Draft Report on TRAC-M and RELAP5 Calculation Comparisons ADAMS ML020930525 Approved:

Signed Jack E. Rosenthal 04/02/02 APPROVED AS FINAL Jack Rosenthal, Chief, SMSAB Date Distribution:

SMSAB R/F GRhee R/F CAder PNorian ADAMS Package ML020940055 C:\\ORPCheckout\\FileNET\\ML020940148.wpd OAR in ADAMS? (Y or N) Y ADAMS ACCESSION NO.: ML020940148 TEMPLATE NO. RES-006 Publicly Available? (Y or N) Y DATE OF RELEASE TO PUBLIC 04/08/02 SENSITIVE? No To receive a copy of this document, indicate in the box: "C" = Copy without enclosures "E" = Copy with enclosures "N" = No copy OFFICE SMSAB SMSAB C:SMSAB NAME GRhee:mb ANotafrancesco JRosenthal DATE 04/02/02*