Duke Duke Energy Energy Oconee Nuclear Station 7800 Rochester Highway Seneca, SC 29672 W. R. McCollum, Jr.
(864) 885-3107 OFFICE Vice President (864) 885-3564 FAx March 20, 2002 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555
Subject:
Duke Energy Corporation Oconee Nuclear Station, Unit 1,2,3 Docket Nos.
50-269,
- 270, 287 Third Ten Year Inservice Inspection Interval Request for Relief No.01-001 (TAC MB1706)
On April 5,
- 2001, Duke Energy Corporation (Duke) submitted Request for Relief No.
01-01 pursuant to 10 CFR 50.55a(g)
(5) (iii) and 50.55a(g) (6) (i).
This request was for eleven (11) components for which Duke personnel determined it is impractical to meet the volumetric requirements for ultrasonic examination of certain specified welds due to piping/vessel geometry, interferences, and existing examination technology.
The request sought relief to accept the portions of the weld volume that can be practically examined.
Through subsequent discussions with the Staff, Duke has concluded that a portion of the request was confusing and poorly worded.
In order to clarify our request, please replace the existing Section III, "Code Requirement from which Relief is Requested" with the new Section III provided on the attachment to this letter.
If there are any questions or further information is needed you may contact R.
P.
Todd at (864) 885-3418.
Very truly yours,
- W~et~ lum.Jr.
W..
c)llum '
Site Vice P
- ident Attachment
U.
S. Nuclear Regulatory Commission March 20, 2002 Page 2 xc w/att: L.
A. Reyes, Regional Administrator U.S. Nuclear Regulatory Commission, Region II Atlanta Federal Center 61 Forsyth St.,
- SWW, Suite 23T85
- Atlanta, GA 30303 L.
N. Olshan, Project Manager, Section 1 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation U.
S. Nuclear Regulatory Commission Washington, DC 20555-0001 Scott Freeman Acting NRC Senior Resident Inspector Oconee Nuclear Station Mr. Virgil Autrey Division of Radioactive Waste Management Bureau of Land and Waste Management SC Dept. of Health & Environmental Control 2600 Bull St.
- Columbia, SC 29201
ATTACHMENT Ill.
Code Requirement from which Relief is Requested:
Examination Cateciory B-D: Relief is requested from the requirement to scan the entire examination volume as shown in figure IWB-2500-7.
Examination Category C-B: Relief is requested from the requirement to scan the entire examination volume as shown in figure IWC-2500-4 (a) or (b).
Examination Category B-J: Relief is requested from the requirement to examine 100% of volume C-D-E-F of IWB-2500-8.
Examination Category C-F-i: Relief is requested from the requirement to examine 100% of volume C-D-E-F of IWC-2500-7.