P Duke W Energy.
Duke Energy Corporation McGuire Nuclear Station 12700 Hagers Ferry Road Huntersville, NC 28078-9340 (704) 875-4800 OFFICE (704) 875-4809 FAX H. B. Barron Vice President March 20, 2002 U. S. Nuclear Regulatory Commission Document Control Desk Washington, D.C. 20555
Subject:
McGuire Nuclear Station Docket Nos. 50-370 Unit 2 Steam Generators EOC-14 Refueling Outage Pursuant to Technical Specification 5.6.8 part a and part b, the following information is submitted:
- 1) The following quantity of tubes were inspected from either side of the generator:
B C
C Quantity 6630 29 6632 79 Inspection Method Bobbin MRPC Bobbin MRPC
- 2) The following information is submitted concerning indications of tube imperfections.
(The attached lists identify the tubes with imperfections, their locations and their size.)
Steam Generator Attachment B
C
- 3) There were no tubes removed from service by plugging.
H. B. Barron I
AýVxzc,(ýý 1\\ 0 0ý
U. S. Nuclear Regulatory Commission March 20, 2002 Page 2 cc:
Mr. L. A Reyes Regional Administrator, Region II U. S. Nuclear Regulatory Commission 61 Forsyth St., SW, Suite 23T85 Atlanta, Georgia 30323 Mr. R. E. Martin, Project Manager Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D.C. 20555 Mr. Scott Shaeffer Senior NRC Resident Inspector McGuire Nuclear Station
U. S. Nuclear Regulatory Commission March 20, 2002 Page 3 bxc:
EC050-ELL RGC File Randy Klein - MGO1MM Emma Currence Master File
-Framatome ANP Inc.
Customer Name: McGuire
- Unit 2 Replacement 03/18/02 13:43:39 Component: S/G B Indications of Imperfection ROW COL VOLTS 2
123 0.65 9
130 0.20 12 85 0.30 25 24 0.35 47 80 0.27 49 70 0.35 49 82 0.71 54 73
- 0. 14 54 83 0.15 58 71 0.37 0.58 62 61 1.58 62 93 0.23 0.15 64 77
- 0. 18 66 83
- 0. 19 68 71 0.33 70 67 0.18 0.26 72 53 0.37 72 89 0.13 0.10 73 66 0.14 0.24 75 108 0.22 76 77 0.53 77 66 0.12 0.28 78 61 0.18 0.17 78 77 0.17 79 66 0.15 80 67 0.23 0.23 81 78 0.21 84 67 0.24 0.15 85 64 0.32 0.17 87 66 0.14 0.19 87 78 0.20 89 72 0.27 90 67 0.32 0.41 0.08 0.60 91 60 0.24 0.18 91 66 0.15 0.18 91 68 0.16 0.12 93 114 1.14 0.22 0.11 95 114 1.39 0.21 0.i0 98 75 0.14 0.09 99 74 0.28 0.16 99 80 1.17 100 95 0.47 101 66 0.15 0.17 102 61 0.30 0.47 103 76 0.13 0.15 104 49 0.25 105 66 0.27 0.33 DEG CHN IND %TW LOCATION 42 83 78 76 88 84 18 86 93 91 96 16 92 18 81 84 131 0
0 86 77 0
0 0
66 97 0
0 0
0 99 0
0 0
87 0
0 108 0
0 0
85 74 0
0 0
84 0
0 0
0 0
0 164 87 91 160 68 94 76 10 53 0
72 71 0
0 0
0 115 0
91 0
0 HNI HNI ADI HNI HNI HNI 1 HNI HNI HNI ADI ADI HNI 2
TWD 6 3 TWD 5 ADI HNI 1 HNI 2
TWD 5 3
TWD 8 HNI 2
TWD 4 3 TWD 3 2 TWD 4 3 TWD 7 HNI HNI 2 TWD 3 3 TWD 8 2 TWD 5 3 TWD 5 2 TWD 5 2 TWD 4 3 TWD 8 2 TWD 6 2
TWD 6 3 TWD 9 2
TWD 4 3 TWD 7 2
TWD 5 3 TWD 5 2
TWD 5 HNI HNI 3 TWD 11 2
TWD 11 2
TWD 2 2 VOL 3 TWD 9 2 TWD 5 3
TWD 5 2 TWD 5 3
TWD 6 2 TWD 3 PLP PLP PLP PLP PLP PLP 2 TWD 4 3 TWD 2 2 TWD 8 3 TWD 6 HNI HNI 3 TWD 6 2 TWD 4 3 TWD 11 2 TWD 12 2 TWD 4 3 TWD 6 HNI 2 TWD 7 3 TWD 10 08H 03H 08C 06C 04H 01H 09C 05H 04H 02H 06H 09C FB5 FB5 05H 05H CBH FB5 FB5 01H FB8 FB8 FB4 FB4 04H 02C FB4 FB4 FB5 FB5 FB2 FB4 FB3 FB3 FBS FB4 FB4 FB7 FB7 FB3 FB3 01C 09C FB4 FB4 FB5 FB5 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB6 FB6 FB4 FB4 08C TSH FB3 FB3 FB4 FB4 FB3 FB3 04H FB3 FB3 EXT EXT UTIL 1 UTIL 2 CAL # LEG
+30.70
+18.51
+36.49
+34.56
+30.70
+27.87
+12.11
+13.51
+16. 44
+20.55
+14.06
+13.02
+1.64
+2.05
+12.09
+10.77
+3.03
+0.56
+0.35
+24.66
+1.22
+0.83
+0.58
+0.73
+24.41
+20.64
+0.49
+0.69
-1.89
-1.89
+0.81
+0.58
-1.75
-1.75
+0.98
+1. 67
+1. 67
+0.59
+0. 62
+0.70
+0.51
+31.78
+15.20
-1.09
-0.73
-1.07
-1.25
-0.68
-0.53
+0.62
+0.64
+0.60
+0.60
+7.13
+6.89
+7. 69
+6.76
+6.80
+7.
63
+1.80
+1.85
+1.00
+1.02
+31.55
+8.73
+0.67
+0.56
-1.13
-1.20
+1.69
+1.69
+25.66
+0.70
+0.70 O9W 090 TEC TEN TEC TEK TEC TEC T EC TEN T EN TEN TEN FES TEC TEC TEN TEC FE S TEN TEC FEE TEC FE 4 TEC TEC TEC FE 4 TEC FE 4 TEC T EC FE2 TEC TEC FE 4 TEC FE7 TEC 09H TEC TEC TEN FE 4 TEC TEC FE S FE 3 TEC FE3 TEC FE 3 TEC TEC FE 3 FE 3 TEC FE 3 FE 3 T EC FEE T EC FE 4 T EC TEC FE 3 T EC FE 4 T EC TEC FE3 TEN TEC FE 3 TEH TEH TEH TEC TEH TEC TEH TEH TEH TEC TEC TEC TEC FB5 TEH TEH TEC TEH FB5 TEC TEH FB8 TEH FB4 TEH TEH TEH FB4 TEH FB5 TEH TEH FB3 TEH TEH FB5 TEH FB7 TEH FB3 TEH TEH TEC FB4 TEH TEH FB5 FB3 TEH FB3 TEH FB3 TEH TEH FB4 FB4 TEH FB4 FB4 TEH FB6 TEH FB4 TEH TEH FB3 TEH FB4 TEH TEH FB4 TEC TEH FB3 WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 50 48 26 41 24 33 26 24 28 35 35 53 91 99 24 28 33 100 108 21 76 97 100 108 18 8
100 108 100 108 76 100 106 100 76 106 100 97 100 106 100 6
27 106 100 100 101 106 100 106 100 106 100 20 108 108 18 108 108 76 97 76 106 12 14 106 100 106 100 76 106 19 100 108 WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR HOT HOT HOT COLD HOT COLD HOT HOT HOT COLD COLD COLD COLD COLD HOT HOT COLD HOT HOT COLD HOT COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD HOT HOT HOT HOT COLD HOT HOT HOT COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD HOT HOT Page 1 of 2 PROBE 560BP 560BP 560RD 560RD 560RD 5 60RD 560RD 560RD 560RD 560UL 560UL 560RD 560RD 460SI 560RD 560RD 560RD 560UL 540SI 560UL 560BP 540SI 560UL 540SI 560RD 560RD 560UL 540SI 560UL 540SI 560BP 560UL 540SI 560UL 560BP 540SI 560UL 540SI 560UL 540SI 560UL 560RD 560RD 540SI 56OUL 560UL 460SI 540SI 560UL 540SI 560UL 540SI 560UL 560RD 540SI 540SI 560RD 540SI 540SI 560BP 540SI 560BP 540SI 560RD 560RD 540SI 560UL 540SI 560UL 560BP 540SI 560UL 560UL 540SI
Framatome ANP Inc.
Customer Name: McGuire -
Unit 2 Replacement Indications of Imperfection QUERY:
QueryMl DEG CHN 115 P 2 0
P 3 0
P 2 0
P 3 0
P 3 0
P 2 IND TWD TWD TWD TWD TWD TWD
%TW 3
5 2
5 9
10 LOCATION FB6
+1.79 FB6
+1.69 FB3
+0.62 FB3
+0.62 FB4
+1.22 FB4
+0.64 03/18/02 13:43:39 Component:
S/G B EXT TEC FB6 TEC FB3 FB4 TEC EXT TEH FB6 TEH FB3 FB4 TEH UTIL 1 UTIL 2 CAL #
WAR WAR WAR WAR WAR WAR Total Tubes 50 Total Records:
80 ROW 106 107 108 COL 75 66 61 VOLTS 0.12 0.17 0.10 0.17 0.26 0.36 Page 2 of 2 PROBE 560BP 540SI 56OUL 540SI 540SI 560UL LEG HOT COLD HOT HOT HOT HOT 76 97 100 108 106 100
McGUIRE UNIT 2 SIG B REPAIR LETTER RFO-02 STEAM G ENERATOR B
RMQW L
COMMENTS No Tubes To Be Repair Independent QDA Review Analysts:
Carson R. Black III Prepared & Approved By:
Ronald D. Sm eth-rs ECT Concurrence:
Framatome ANP Inc.
Customer Name: McGuire - Unit 2 Replacement 03/18/02 13:47:57 Component: S/G C Indications of Imperfection ROW 1
1 2
7 11 13 27 27 43 47 48 48 49 49 51 53 54 54 54 56 57 57 58 58 58 58 59 60 61 61 61 61 62 62 63 63 64 65 65 66 66 68 68 68 68 68 68 69 71 71 72 75 78 80 80 80 COL VOLTS 28 1.22 128 11.08 11 1.16 6
1.16 52 0.15 128 1.09 30 0.85 44
- 0. 15 0.12 60 0.16 50 0.23 71 1.25 77 0.04 0.15 34 0.23 0.16 46 0.22 0.16 86 0.22 94 0.17 0.28 67 0.19 0.22 75 0.14 91 0.07 61 0.17 0.20 82 0.09 0.21 90 0.35 51 0.10 79 0.17 0.18 89 0.33 91 0.26 92 0.14 91 0.26 64 0.18 0.22 80 0.17 0.22 90 0.28 92 0.15 89 0.17 91 0.18 60 0.14 0.16 92 0.10 91 0.17 54 0.11 90 0.19 89 0.12 91 0.17 15 0.49 0.24 49 0.18 53 0.17 63 0.15 85 0.29 91 0.12 90 0.15 64 0.11 88 0.46 0.22 73 0.25 0.16 66 0.10 0.08 67 0.16 0.06 45 0.42 67 0.58 0.38 79 0.14 0.25 EXT UTIL I UTIL 2 DEG 257 179 65 258 86 259 78 86 84 87 0
67 0
0 86 72 79 74 0
0 0
0 0
0 65 0
0 0
0 55 0
0 0
56 54 59 59 0
0 0
0 52 50 61 52 0
0 60 50 0
51 51 54 80 50 0
0 0
0 56 58 0
0 0
165 0
27 0
135 0
70 109 0
133 0
CHN 7
1 6
7 6
7 6
6 6
6 P 2 6
P 2 P 3 6
6 6
6 P 2 P 2 P 3 P 2 P 3 P 2 7
P 2 P 3 P 2 P 3 7
P 2 P 2 P 3 7
7 7
7 P 2 P 3 P 2 P 3 7
7 7
7 P 2 P 3 7
7 P 2 7
7 7
6 6
P 2 P 2 P 2 P 2 7
7 P 2 P 3 P 2 P 3 P 2 P 3 P 2 P 3 P 2 6
P 3 P 2 P 3 P 2 Page 1 of 3 IND PLP DNT ADI PLP ADI PLP HNI HNI HNI HNI TWD HNI TWD TWD ADI ADI HNI HNI TWD TWD TWD TWD TWD TWD PLP TWD TWD TWD TWD PLP TWD TWD TWD PLP PLP PLP PLP TWD TWD TWD TWD PLP PLP PLP PLP TWD TWD PLP PLP TWD PLP PLP PLP HNI HNI TWD TWD TWD TWD PLP PLP TWD TWD TWD TWD TWD TWD TWD TWD TWD ADI TWD TWD TWD TWD
%TW LOCATION 07H CBH 04C 06H 01C 06C 03H 01H 01H 01H 6
FB4 01H 1
FB5 2
FB5 02H 02H 02C 02C 5
FB4 4
FB5 4
FB5 5
FB4 4
FB4 3
FB4 TSC 5
FB5 3
FB5 2
FB3 3
FB3 TSC 3
FB4 4
FB5 3
FB4 4
FB4 4
FB5 3
FB5 2
FB5 TSC TSC 3
FB5 5
FB4 4
FB5 7
FB5 TSC TSC 3
FB5 9
FB5 6
FB5 6
FB4 4
FB4 2
FB4 2
FB4 4
FB5 1
FB5 08H 13 FB5 10 FB5 3
FB4 6
FB4 EXT
+3.64 09C
+6.23 09C
+32.04 CBC
+7.82 09C
+7.14 TEC
+20.44 TEH
+13.06 TO+24.71 TEC
+25.53 TEC
+23.64 TEC
+5.69 TEC
+0.56 TEC
+20.16 TEC
+1.59 TEH
+1.49 B5
+21.67 TEC
+19.11 TEC
+7.74 TEC
+8.60 TEC
-1.60 TEH
+1.63 TEH
+1.68 FB5
-1.63 TEC
-1.66 FB4
+0.97 TEH
+11.47 TEH
+1.65 TEC
+1.53 FB5
-1.57 TEH
-1.52 FB3
+11.50 TEH
-1.20 TEC
+1.54 TEH
+1.54 FB5
+11.55 TEH
+11.45 TEH
+11.50 TEH
+1i.66 TEH
-1.69 TEC
-1.80 FB4
-0.94 TEH
-1.04 FB5
+11.56 TEH
+11.46 TEH
+11.53 TEH
+11.42 TEH
+0.80 TEC
+0.64 FB5
+11.52 TEH
+11.68 TEH
+0.82 TEC
+11.49 TEH
+11.50 TEH
+11.47 TEH
+19.14 TEC
+14.81 TEC
-0.60 TEC
+1.07 TEC
-1.71 TEC
+0.94 TEH
+11.47 TEH
+11.56 TEH
+1.19 TEC
+1.51 FB5
+1.42 TEC
-0.97 FB4
-0.98 TEC
-1.18 FB4
-1.01 TEC
-0.90 FB5
-0.93 TEC
+32.97 TEC
+1.35 FB5
+1.22 TEC
-1.86 FB4
-1.68 TEC TEH TEH TEC TEH TEH TEC TEH TEH TEH TEH TEH TEH TEC FB5 TEH TEH TEH TEH TEC TEC FB5 TEH FB4 TEC TEC TEH FB5 TEC FB3 TEC TEH TEC FB5 TEC TEC TEC TEC TEH FB4 TEC FB5 TEC TEC TEC TEC TEH FB5 TEC TEC TEH TEC TEC TEC TEH TEH TEH TEH TEH TEC TEC TEC TEH FB5 TEH FB4 TEH FB4 TEH FB5 TEH TEH
£B5 TEH FB4 TEH WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR CAL #
38 46 73 36 34 31 16 30 30 62 84 56 103 104 18 18 32 32 103 103 104 84 102 103 49 84 104 103 104 51 84 103 104 51 49 49 47 84 102 103 104 51 47 51 49 84 104 49 47 84 51 51 49 18 18 84 84 84 103 47 51 90 102 90 100 90 100 90 100 90 74 100 90 100 90 LEG HOT HOT COLD HOT HOT COLD HOT HOT HOT HOT HOT HOT COLD HOT HOT HOT HOT HOT COLD COLD HOT HOT HOT COLD COLD HOT HOT COLD HOT COLD HOT COLD HOT COLD COLD COLD COLD HOT HOT COLD HOT COLD COLD COLD COLD HOT HOT COLD COLD HOT COLD COLD COLD HOT HOT HOT HOT HOT COLD COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT PROBE 560BP 560BP 5 60RD 560BP 560RD 560RD 560RD 560RD 560RD 560UL 560BP 560UL 560RD 520SI 560RD 560RD 560RD 560RD 560RD 5 60RD 520SI 5 60BP 520SI 560RD 560RD 560BP 520SI 560RD 520SI 560RD 560BP 560RD 520SI 560RD 560RD 560RD 56ORD 560BP 520SI 560RD 520SI 560RD 560RD 560RD 560RD 560BP 520SI 56ORD 560RD 560BP 560RD 560RD 560RD 560RD 5 60RD 560BP 560BP 560BP 560RD 560RD 560RD 560BP 520SI 560BP 540SI 560BP 540SI 560BP 540SI 560BP 560BP 540SI 560BP 540SI 560BP
- Framatome ANP Inc.
Customer Name: McGuire - Unit 2 Replacement Indications of QUERY: QueryMl ROW COL VOLTS 81 64 0.39 0.21 82 61 0.08 0.03 82 79 0.08 0.19 82 85 0.13 0.24 86 65 0.12 0.03 86 79 0.11 0.20 86 89 0.10 0.09 87 84 0.08 88 85 0.15 0.21 90 61 0.19 0.13 90 117 0.84 92 73 0.15 0.18 93 80 0.15 0.19 94 87 0.14 0.23 95 76 0.18 0.13 96 83 0.23 0.12 98 79 0.16 98 85 0.21 0.29 98 89 0.14 99 86 0.32 0.28 101 80 0.25 0.30 102 77 0.27 0.19 104 57 1.15 105 78 0.17 105 84 0.12
- 0. 23 107 78 0.08 0.17 107 80 0.10 0.17 108 75 0.10 0.10 110 77 0.09 0.13 110 79 0.06 0.05 110 91 0.20 0.07 111 80 0.14 0.07 0.03 112 73 2.63 1.56 113 72 0.72 2.18 114 83 0.12 0.07 115 76 0.13 0.12 03/18/02 13:47:57 Component: S/G C Imperfection DEG CHN IND 15 P 3 TWD 0
P 2 TWD 12 P 3 TWD 0
P 2 TWD 15 P 3 TWD 0
P 2 TWD 56 P 2 TWD 0
P 3 TWD 166 P 3 TWD 0
P 2 TWD 111 P 3 TWD 0
P 2 TWD 34 P 3 TWD 0
P 2 TWD 0
P 2 TWD 151 P 3 TWD 0
P 2 TWD 0
P 2 TWD 0
P 3 TWD 61 6
HNI 133 P 3 TWD 0
P 2 TWD 163 P 3 TWD 0
P 2 TWD 23 P 3 TWD 0
P 2 TWD 44 P 3 TWD 0
P 2 TWD 85 P 2 TWD 0
P 3 TWD 83 6
ADI 159 P 3 TWD 0
P 2 TWD 82 6
ADI 124 P 3 TWD 0
P 2 TWD 146 P 3 TWD 0
P 2 TWD 43 P 3 TWD 0
P 2 TWD 77 6
HNI 0
P 2 TWD 131 P 3 TWD 0
P 2 TWD 196 P 3 TWD 0
P 2 TWD 163 P 3 TWD 0
P 2 TWD 8
P 3 TWD 0
P 2 TWD 0
P 3 TWD 0
P 2 TWD 8
P 3 TWD 0
P 2 TWD 71 P 3 TWD 0
P 2 TWD 17 P 3 TWD 169 P 3 TWD 0
P 2 TWD 144 7 PLP 63 7
PLP 52 7
PLP 144 7 PLP 92 P 3 TWD 0
P 2 TWD 99 P 3 TWD 0
P 2 TWD
%TW LOCATICO 9
FB4 6
FB4 2
FB5 1
FB5 2
FB4 5
FB4 3
FB5 4
FB5 3
FB5 1
FB5 3
FB4 5
FB4 3
FB4 2
FB4 2
FB5 4
FB4 5
FB4 5
FB4 5
FB4 09H 4
FB5 5
FB5 5
FB7 5
FB7 4
FB5 6
FB5 6
FB4 3
FB4 6
FB5 5
FB5 01H 7
FB5 7
FB5 01H 10 FB4 7
FB4 8
FB4 8
FB4 9
FB3 5
FB3 06C 4
FB4 4
FB4 6
FB4 2
FB3 4
FB3 3
FB7 4
FB7 3
FB4 3
FB4 2
FB3 3
FB3 2
FB7 1
FB7 6
FB4 2
FB4 4
FB4 2
FB4 1
FB4 TSH TSH TSH TSH 4
FB4 2
FB4 4
FB3 3
FB3 EXT
+1.28 FB4
+l.22 TEC
-1.55 FB5
-1.48 TEC
-1.58 FB4
-1.60 TEC
-0.71 TEC
-0.84 FB5
-0.61 FB5
-0.63 TEC
-1.79 FB4
-1.68 TEC
+1.51 FB4
+1.39 TEC
+0.76 TEC
-1.57 FB4
-1.71 TEC
-0.93 TEC
-1.05 FB4
+10.17 TEH
-0.76 FB5
-0.79 TEC
+1.79 FB7
+1.86 TEC
+1.48 FB5
+1.68 TEC
-0.70 FB4
-0.73 TEC
-1.31 TEC
-1.26 FB5
+19.29 TEH
-1.54 FB5
-1.69 TEC
+20.53 TEH
+0.75 FB4
+0.68 TEC
+0.77 FB4
+0.58 TEC
+0.56 FB3
+0.52 TEC
+29.03 TO+16.71 TEC
+1.33 TEC
+0.74 FB4
+0.68 TEC
+1.65 FB3
+1.86 TEC
+1.66 FB7
+1.86 TEC
-1.68 FB4
-1.75 TEC
+0.58 FB3
+0.71 TEC
+0.59 FB7
+0.58 TEC
+1.30 FB4
+1.37 TEC
-1.05 FB4
+1.21 FB4
+1.34 TEC
+13.87 TSH
+13.65 TEH
+13.91 TEC
+13.81 TSH
-1.50 FB4
-1.47 TEC
+1.59 FB3
+1.80 TEC EXT FB4 TEH FB5 TEH FB4 TEH TEH FB5 FB5 TEH FB4 TEH FB4 TEH TEH FB4 TEH TEH FB4 TEC FB5 TEH FB7 TEH FB5 TEH FB4 TEH TEH FB5 TEC FBS TEH TEC FB4 TEH FB4 TEH FB3 TEH TEH TEH FB4 TEH FB3 TEH FB7 TEH FB4 TEH FB3 TEH FB7 TEH FB4 TEH FB4 FB4 TEH 01H TEC TEH 01H FB4 TEH FB3 TEH UTIL WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR HR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR i UTIL 2 CAL #
100 90 100 90 100 90 90 104 100 90 100 90 100 90 90 100 90 90 117 11 98 90 96 90 96 90 96 90 90 117 23 96 90 17 96 90 96 90 96 90 68 90 96 90 96 90 96 90 96 90 96 90 96 90 96 90 96 96 90 92 21 64 92 96 90 96 90 Total Tubes 92 Total Records: 142 Page 2 of 3 LEG HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD COLD HOT HOT COLD HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT HOT COLD HOT HOT HOT HOT HOT HOT PROBE 540SI 560BP 540SI 560BP 540SI 560BP 560BP 520SI 540SI 560BP 540SI 560BP 540SI 560BP 560BP 540SI 560BP 560BP 540SI 560RD 540SI 560BP 540SI 560BP 540SI 560BP 540SI 560BP 560BP 540SI 560RD 540SI 560BP 560RD 540SI 5 60BP 540SI 560BP 540SI 560BP 560BP 560BP 540SI 560BP 540SI 560BP 540SI 560BP 540SI 560BP 540SI 560BP 540SI 560BP 540SI 560BP 540SI 540SI 560BP 540SI 5 60RD 560BP 540SI 540SI 560BP 540SI 560BP
Framatome ANP Inc.
Customer Name: McGuire -
Unit 2 Replacement Indications of Imperfection QUERY: QueryMl ROW COL VOLTS DEG CHN IND %TW LOCATION 03/18/02 13:47:57 Component: S/G C EXT EXT UTIL 1 UTIL 2 CAL # LEG Page 3 of 3 PROBE
McGUIRE UNIT 2 S/G C REPAIR LETTER RFO-02 STEAM GENERATOR RW COL C
COMMENTS No Tubes To Be Repair Independent QDA Review Analysts:
Prepared & Approved By:
Ronald D. Smathers ECT Concurrence:
I
Compliance Functional Area Manual 3.13 COLR Rev. 3, Page 1 of 1 NEW/REVISED COLR IMPLEMENTATION AND DISTRIBUTION SHEET CNS
_ MNS _ONS UNITNO. __
2 3
Affected COLR Revision:
SECTION 1 - COLR IMPLEMENTATION COLR IMPLEMENTATION INSTRUCTIONS AS SPECIFIED IN THE ENGINEERING INSTRUCTION Must include implementation time frame and transition requirements (if applicable):
I,
. Ck-..,(5,Iv Vbr Q Quoo SECTION 2 - COLR DISTRIBUTION ACKNOWLEDGMENT OF RECEIPT OF COLR REVISION CONTROL ROOM Date:
OPERATIONS SUPPORT Date:
OPERATIONS TRAINING Date:
REACTOR GROUP Date:
CHEMISTRY Date:
I&E Date:
s4 LOCAL, IT Date:_
After signig above, return this form to:
in Regulatory Compliance.
FINAL REGULATORY COMPLIANCE SIGNOFF The COI.R reision has been implemented at the site in accordance with instruction,, contained in the COL[R document. Distribution to the above locations has been completed.
Regulatory Compliance Date 7 of I0