Tennessee Valley Authority, Post Office Box 2000, Spring City, Tennessee 37381-2000 MAR 1 2.2002 10 CFR 50.4 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555 Gentlemen:
In the Matter of
)
Docket No. 50-390 Tennessee Valley Authority
)
WATTS BAR NUCLEAR PLANT (WBN) -UNIT 1-REPORT OF U1C4 REFUELING OUTAGE STEAM GENERATOR TUBE INSPECTION (F*) IN ACCORDANCE WITH WBN TECHNICAL SPECIFICATION (TS) 5.9.9 In accordance with WBN TS 5.9.9, this report provides the results of WBN Unit 1 steam generator (SG) tube inspections for three tubes having indications which may remain in service using the F* alternate repair criteria. As required by the WBN TS, the data below includes identification of these tubes, the uppermost elevation of the degradation, and the extent of the degradation.
Location of SG Row Column Indication Crack Tip Length BRT 3
19 75 PWSCC Axial
> 2" below TTS HTS+0.00 3
22 79 PWSCC Axial
> 2" below TTS HTS-0.13 3
38 18 OD Volumetric HTS-2.15 0.23" HTS-0.13 Acronyms:
BRT - Bottom of Roll Transition HTS - Hot Leg Top of Tube Sheet OD - Outside Diameter PWSCC - Primary Water Stress Corrosion Cracking TTS - Top of Tube Sheet
U.S. Nuclear Regulatory Commission Page 2 MAR 1 2 2002 If you have any questions about this report, please contact me at (423) 365-1824.
Paul L. Pace, Manager Licensing and Industry Affairs cc: See page 3 r
t U.S. Nuclear Regulatory Commission Page 3 HARI 12 2002 cc:
NRC Resident Inspector Watts Bar Nuclear Plant 1260 Nuclear Plant Road Spring City, Tennessee 37381 Mr. L. Mark Padovan, Senior Project Manager U.S. Nuclear Regulatory Commission MS 08G9 One White Flint North 11555 Rockville Pike Rockville, Maryland 20852-2738 U.S. Nuclear Regulatory Commission Region II Sam Nunn Atlanta Federal Center 61 Forsyth St., SW, Suite 23T85 Atlanta, Georgia 30303