March 14, 2002 MEMORANDUM TO:

Anthony J. Mendiola, Chief, Section 2 Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation FROM:

Stephen Sands, Project Manager, Section 2 /RA/

Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation

SUBJECT:

FORTHCOMING PUBLIC MEETING WITH INTERESTED EXTERNAL STAKEHOLDERS DATE & TIME:

Wednesday, March 20, 2002 1:00 p.m. to 5:00 p.m.

LOCATION:

U.S. Nuclear Regulatory Commission One White Flint North 11555 Rockville Pike, Commission Meeting Room*

Rockville, Maryland PURPOSE:

To discuss current knowledge relating to the recently identified degradation of the reactor vessel head at the Davis-Besse Nuclear Power Station PARTICIPANTS:

NRC B. Sheron J. Strosnider W. Bateman J. Zwolinski R. Barrett, et al Docket No. 50-346 cc: See next page CONTACT:

Stephen Sands, 301-415-3154 or Douglas Pickett, 301-415-1364

  • Stakeholders wishing to participate via telephone may call the bridge at (301) 231-5539 or (800) 638-8081 and enter passcode 5315# at the prompt. Fifty tie-in lines will be available. If difficulties are experienced, dial (800) 368-5642 and request the operator to add you to the conference call.

March 14, 2002 MEMORANDUM TO:

Anthony J. Mendiola, Chief, Section 2 Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation FROM:

Stephen Sands, Project Manager, Section 2 /RA/

Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation

SUBJECT:

FORTHCOMING PUBLIC MEETING WITH INTERESTED EXTERNAL STAKEHOLDERS DATE & TIME:

Wednesday, March 20, 2002 1:00 p.m. to 5:00 p.m.

LOCATION:

U.S. Nuclear Regulatory Commission One White Flint North 11555 Rockville Pike, Commission Meeting Room*

Rockville, Maryland PURPOSE:

To discuss current knowledge relating to the recently identified degradation of the reactor vessel head at the Davis-Besse Nuclear Power Station PARTICIPANTS:

NRC B. Sheron J. Strosnider W. Bateman J. Zwolinski R. Barrett, et al Docket No. 50-346 cc: See next page CONTACT:

Stephen Sands, 301-415-3154 or Douglas Pickett, 301-415-1364

  • Stakeholders wishing to participate via telephone may call the bridge at (301) 231-5539 or (800) 638-8081 and enter passcode 5315# at the prompt. Fifty tie-in lines will be available. If difficulties are experienced, dial (800) 368-5642 and request the operator to add you to the conference call.

Distribution:

PUBLIC KJohnson AMendiola PMNS OGC PD3-2 r/f THarris SSands WBateman ACRS BSheron AHiser CLipa SBajwa OPA Zwolinski/Marsh HNieh DPickett JStrasma G:\\PDIII-2\\DAVISBES\\Meeting Notice 03-20-02.wpd ADAMS Accession Number: ML020730024

  • SEE PREVIOUS CONCURRENCE OFFICE PM:LPD3-2 LA:LPD3-2 SC:EMCB SC:LPD3-2 D:LPD3 NAME SSands THarris
  • WBateman AMendiola SBajwa DATE 03/14/02 03/14/02 03/13/02 03/14/02 03/14/02 OFFICIAL RECORD COPY

Distribution for Meeting Notice dated:

Hard Copy:

E-mail:

PDIII-2 r/f PMNS OGC OPA ACRS JShea OWFN Receptionist SRosenberg TWFN Receptionist BSheron JStrosnider/RBarrett BBateman AHiser KKarwoski ALee JZwolinski/TMarsh GHolahan/SBlack MReinhart SLong AMendiola SBajwa SSands DPickett GGrant, R3

Davis-Besse Nuclear Power Station, Unit 1 cc:

Mary E. OReilly Dennis Clum FirstEnergy Radiological Assistance Section Supervisor 76 South Main Street Bureau of Radiation Protection Akron, OH 44308 Ohio Department of Health P.O. Box 118 Manager - Regulatory Affairs Columbus, OH 43266-0118 FirstEnergy Nuclear Operating Company Davis-Besse Nuclear Power Station Carol OClaire, Chief, Radiological Branch 5501 North State - Route 2 Ohio Emergency Management Agency Oak Harbor, OH 43449-9760 2855 West Dublin Granville Road Columbus, OH 43235-2206 Director Zack A. Clayton Ohio Department of Commerce DERR Division of Industrial Compliance Ohio Environmental Protection Agency Bureau of Operations & Maintenance P.O. Box 1049 6606 Tussing Road Columbus, OH 43266-0149 P.O. Box 4009 Reynoldsburg, OH 43068-9009 State of Ohio Public Utilities Commission Regional Administrator 180 East Broad Street U.S. Nuclear Regulatory Commission Columbus, OH 43266-0573 801 Warrenville Road Lisle, IL 60523-4351 Attorney General Department of Attorney Michael A. Schoppman 30 East Broad Street Framatome ANP Columbus, OH 43216 1911 N. Ft. Myer Drive Rosslyn, VA 22209 President, Board of County Resident Inspector Commissioners of Ottawa County U.S. Nuclear Regulatory Commission Port Clinton, OH 43252 5503 North State Route 2 Oak Harbor, OH 43449-9760 Plant Manager, Randel J. Fast FirstEnergy Nuclear Operating Company Davis-Besse Nuclear Power Station 5501 North State - Route 2 Oak Harbor, OH 43449-9760