January 2002 Monthly Operating Report for Nine Mile Point Nuclear Station, Unit 2
ML020650279
Person / Time
Site: Nine Mile Point 
(NPF-069)
Issue date: 02/07/2002
From: Peckham M
Constellation Nuclear
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NMP2L 2048
Download: ML020650279 (4)


Text

P.O. Box 63 Lycoming, New York 13093 Constellation Nuclear Nine Mile Point Nuclear Station February 7, 2002 A Member of the NMIP2L 2048 Constellation Energy Group U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555

'RE:

Nine Mile Point Unit 2 Docket No. 50-410 NPF-69

Subject:

Monthly Operating Report for January 2002 Gentlemen:

Submitted herewith is the Operating Data Report, the Unit Shutdowns, and Summary of Operating Experience for January 2002.

Ver

yours, M. F. Peckham Unit 2 Plant General Manager MFP/cld Attachments cc:

Mr. H. J. Miller, NRC Regional Administrator, Region I Mr. G. K. Hunegs, NRC Senior Resident Inspector Records Management

NIAGARA MOHAWK POWER CORPORATION NINE MILE POINT NUCLEAR STATION UNIT #2

SUMMARY

OF OPERATING EXPERIENCE Nine Mile Point Unit Two operated with a capacity factor (MDC) of 101.63% and an availability factor of 100.00% for the month of January 2002.

On January 6, 2002 at 1203 hours0.0139 days <br />0.334 hours <br />0.00199 weeks <br />4.577415e-4 months <br />, a planned power reduction to 90% was performed for a control rod pattern adjustment. The plant was returned to full power at 1506 hours0.0174 days <br />0.418 hours <br />0.00249 weeks <br />5.73033e-4 months <br /> the same day.

On January 19, 2002 at 0000 hours0 days <br />0 hours <br />0 weeks <br />0 months <br />, Operations commenced a planned power reduction to 55% to remove the "B" feedwater pump from service and to place the "A" feedwater pump in service. Full power operation was resumed at 0430 hours0.00498 days <br />0.119 hours <br />7.109788e-4 weeks <br />1.63615e-4 months <br /> on January 20.

On January 204 at 2200 hours0.0255 days <br />0.611 hours <br />0.00364 weeks <br />8.371e-4 months <br />, a power reduction to 90% was performed for a control rod pattern adjustment. This power reduction was planned as part of the restoration from the feedwater pump exchange. 100% power was achieved at 0109 hours0.00126 days <br />0.0303 hours <br />1.802249e-4 weeks <br />4.14745e-5 months <br /> on January 21, 2002.

On January 30, 2002 at 2303 hours0.0267 days <br />0.64 hours <br />0.00381 weeks <br />8.762915e-4 months <br />, a planned power reduction to 90% was performed for a control rod pattern adjustment. The plant was returned to full power at 0225 hours0.0026 days <br />0.0625 hours <br />3.720238e-4 weeks <br />8.56125e-5 months <br /> on January 31, 2002.

There were no challenges to the safety relief valves during this reporting period.

OPERATING DATA REPORT DOCKET NO.: 50410 DATE: 02/04/02 PREPARED BY: T. McMahon TELEPHONE: (315) 349-4045 OPERATING STATUS Unit Name:

Reporting Period:

Design Electrical Rating (MWe)

Maximum Dependable Capacity (Net MWe):

3. Number of Hours Reactor was Critical
4. Hours Generator On-Line
5. Reactor Reserve Shutdown Hours
6. Net Electrical Energy Gen. (MWH)

Nine Mile Point Unit #2 January 2002 1143.3 1119.8 This Month 744.0 744.0 0.0 846,684.6

1.

2.

Yr-to-Date 744.0 744.0 0.0 846,684.6 Cumulative 95,947.2 93,125.0 0.0 96,905,017.4

UNIT SHUTDOWNS APPENDIX B REPORTING PERIOD - January 2002 Prepared by: T. McMahon DOCKET NO: 50-410 UNIT NAME: NMP#2 DATE: 02/04/02 TELEPHONE: (315) 349-4045 Duration Method of Cause & Corrective Actions No.

Date Type (Hours)

Reasons Shutting Down 2 Comments F:Forced S: Scheduled

-- NONE--

Reason:

A-Equipment Failure (Explain)

B-Maintenance or Test C-Refueling D-Regulatory Restriction E-Operator Training & License Exam F-Administrative G-Operational Error (Explain)

H-Other (Explain)

Method:

1-Manual 2-Manual Trip/Scram 3-Automatic Trip/Scram 4-Continuation 5-Other (Explain)