ECCS Instrumentation 3.3.5.1 Table 3.3.5.1-1 (page 4 of 5)

Emergency Core Cooling System Instrumentation Applicable Conditions Modes or Required Referenced Other Channels From Specified Per Required Surveillance Allowable Function Conditions Function Action A.1 Requirements Value

3. HPCI System (continued)
e. Suppression Pool Water Level - High 1,

2 (c), 3(c)

f. High Pressure Coolant 1

Injection Pump Discharge Flow - Low 2(c), 3 (c)

(Bypass)

4. Automatic Depressurization System (ADS) Trip logic A
a. Reactor Vessel Water Level - Low Low Low
b. Automatic Depressurization System Timer
c. Reactor Vessel Water Level - Low (Confirmatory)
d. Core Spray Pump Discharge Pressure - High
e. Low Pressure Coolant Injection Pump Discharge Pressure High 1,

2 (d), 3 (d) 1, 2 (d), 3 (d) 1, 2 (d), 3 (d) 1, 2 (d), 3 (d) 1, 2 (d) 3 (d) 2 1

1 2

4 G

H SR 3.3.5.1.1 SR 3.3.5.1.3 SR 3.3.5.1.8 SR 3.3.5.1.9 SR 3.3.5.1.3 SR 3.3.5.1.8 SR 3.3.5.1.9 G

SR 3.3.5.1.1 SR 3.3.5.1.3 SR 3.3.5.1.8 SR 3.3.5.1.9 H

SR 3.3.5.1.3 SR 3.3.5.1.8 SR 3.3.5.1.9 H

SR 3.3.5.1.3 SR 3.3.5.1.8 SR 3.3.5.1.9

_> 38.3 inches

< 125 seconds 2 166.1 Inches

Ž 114.2 psig and

< 177.0 psig S103.8 psig and

  • 147.0 psig Amendment No. 245 2

D 1

E SR 3.3.5.1.3 SR 3.3.5.1.8 SR 3.3.5.1.9 SR 3.3.5.1.3 SR 3.3.5.1.8 SR 3.3.5.1.9

< 5.9 inches

>_ 264.2 gpm and 2025.1 gpm 1

(continued)

(c) With reactor steam dome pressure > 150 psig.

(d) With reactor steam dome pressure > 100 psig.

DAEC 3.3-44

ECCS Instrumentation 3.3.5.1 Table 3.3.5.1-1 (page 5 of 5)

Emergency Core Cooling System Instrumentation Applicable Conditions Modes or Required Referenced Other Channels From Specified Per Required Surveillance Allowable Function Conditions Function Action A.1 Requirements Value

5. ADS Trip Logic B
a. Reactor Vessel Water Level - Low Low Low
b. Automatic Depressurization System Timer
c. Reactor Vessel Water Level - Low (Confirmatory)
d. Core Spray Pump Discharge Pressure - High
e. Low Pressure Coolant Injection Pump Discharge Pressure - High 1,

2 (d), 3 (d) 1, 2 (d), 3 (d) 1, 2 (d), 3 (d) 1, 2 (d), 3 (d) 1, 2 (d), 3 (d) 2 G

1 H

1 G

2 H

4 H

SR 3.3.5.1.1 SR 3.3.5.1.3 SR 3.3.5.1.8 SR 3.3.5.1.9 SR 3.3.5.1.3 SR 3.3.5.1.8 SR 3.3.5.1.9 SR 3.3.5.1.1 SR 3.3.5.1.3 SR 3.3.5.1.8 SR 3.3.5.1.9 SR 3.3.5.1.3 SR 3.3.5.1.8 SR 3.3.5.1.9 SR 3.3.5.1.3 SR 3.3.5.1.8 SR 3.3.5.1.9 S38.3 inches

  • 125 seconds 1

_> 166.1 inches

Ž 114.2 psig and 177.0 psig 103.8 psig and

_< 147.0 psig (d) With reactor steam dome pressure > 100 psig.

Amendment No. 245 DAEC 3.3-45