ML020350442
| ML020350442 | |
| Person / Time | |
|---|---|
| Site: | Nine Mile Point |
| Issue date: | 01/09/2002 |
| From: | Hopkins L Constellation Nuclear |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| NMP1L 1635 | |
| Download: ML020350442 (4) | |
Text
P.O. Box 63 Lycoming, New York 13093 Constellation Nuclear Nine Mile Point January 9, 2002 Nuclear Station NMP1L 1635 A Member of the Constellation Energy Group U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 RE:
Nine Mile Point Unit 1 Docket No. 50-220 DPR-63
Subject:
Monthly Operating Report for December 2001 Gentlemen:
Submitted herewith are the Operating Data Report, Unit Shutdowns, and a Narrative of Operating Experience for December 2001 for the Nine Mile Point Nuclear Station Unit 1.
Submittal of this information complies with Section 6.9.1.c of the Unit 1 Technical Specifications.
Very truly yours, Lawrence A. Hopkins Unit 1 Plant General Manager LAH/cld Attachments cc:
Mr. H. J. Miller, NRC Regional Administrator, Region I Mr. G. K. Hunegs, NRC Senior Resident Inspector Records Management
ATTACHMENT A OPERATING DATA REPORT DOCKET NO: 50-220 DATE: 1/04/02 PREPARED BY: P. E. Netusil TELEPHONE: (315) 349-7935 OPERATING STATUS Unit Name: Nine Mile Point Unit #1 Reporting Period: December 2001 Design Electrical Rating: (Net MWe)
Maximum Dependable Capacity: (Net MWe) 613 565 Critical Hours Hours Generator On-Line Unit Reserve Shutdown Hours Net Electrical Energy Generated (MWH)
This Month 744.0 744.0 0.0 458,009.0 Yr-to-Date 7,462.1 7,377.9 0.0 4,378,007.0 Cumulative 197,022.1 192,668.2 20.4 107,030,819.0 3
4 5
6
ATTACHMENT B UNIT SHUTDOWNS REPORTING PERIOD - DECEMBER 2001 (1)
Reason A.
Equipment Failure (Explain)
B.
Maintenance or Test C.
Refueling D.
Regulatory Restriction E.
Operator Training/License Examination F.
Administrative G.
Operational Error (Explain)
H.
Other (Explain)
- NOTE: Sequential numbering used.
DOCKET NO: 50-220 UNIT NAME: NMP1 DATE: 1/04/02 PREPARED BY: P. E. Netusil TELEPHONE: (315) 349-7935 (2)
Method
- 1.
Manual
- 2.
Manual Trip/Scram
- 3.
Automatic Trip/Scram
- 4.
Continuation
- 5.
Other (Explain)
TYPE NO.*
DATE F: FORCED DURATION REASONS' METHOD OF SHUTTING CAUSE & CORRECTIVE ACTIONS
&: SCHEDULED (HOURS)
DOWN2 COMMENTS No shutdown occurred in December 2001
ATTACHMENT C NARRATIVE OF OPERATING EXPERIENCE DOCKET NO: 50-220 UNIT NAME: NMP1 DATE: 1/04/02 PREPARED BY: P. E. Netusil TELEPHONE: (315) 349-7935 The unit operated during the month of December, 2001 with a Net Electrical Design capacity factor of 100.4 percent. There were no challenges to the electromatic relief valves or safety valves during the operating period.