December 2001 Monthly Operating Report for Kewaunee Nuclear Power Plant
ML020350402
Person / Time
Site: Kewaunee Dominion icon.png
Issue date: 01/10/2002
From: Coutu T
Nuclear Management Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NRC-02-006
Download: ML020350402 (5)


Text

Committed to Nuclear Excellen>W Kewaunee Nuclear Power Plant N490 Highway 42 Kewaunee, Wl 54216-9511 920.388.2560 Point Beach Nuclear Plant 6610 Nuclear Road Two Rivers, Wl 54241 920.755.2321 Kewaunee / Point Beach Nuclear Operated by Nuclear Management Company, LLC NRC-02-006 January 10, 2002 10 CFR 50.36 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555 Ladies/Gentlemen:

DOCKET 50-305 OPERATING LICENSE DPR-43 KEWAUNEE NUCLEAR POWER PLANT MONTHLY OPERATING REPORT The narrative "Summary of Operating Experience" and completed forms covering plant and component availability for the Kewaunee Nuclear Power Plant for December 2001 are enclosed in accordance with Technical Specification 6.9.a.3.

Sincerely, KZL4J Thomas Coutu Thomas Coutu Manager-Kewaunee Plant MLA Enc.

cc -

US NRC - Region III NRC Senior Resident Inspector INPO Records Center PSCW - Sharon Henning

KEWAUNEE NUCLEAR POWER PLANT - DOCKET 50-305

SUMMARY

OF OPERATING EXPERIENCE December 2001 Unit continued to be shut down for 2001 Refueling/Maintenance/SGR Outage until December 4. G-1 was closed at 1935, full power (100%) was reached on December 19 at 1625. The unit continues to operate at 100%, steady state power.

Maintenance Group Activities for the Month Instrument and Control Group Activities for the Month I&C completed the following work orders for December:

"* Repaired several core exit thermocouple detector/indication problems

"* Repaired fitting leak on primary system transmitter

"* Installed DCR 3338 for pressure switches on SW header for pressure controls utilizing SW-4A and SW-4B

"* Replaced and repaired a temperature signal converter module in Foxboro protection rack

"* Supported Reactor Physics testing utilizing spare detector and N-43 detector

"* Repaired a leaking Swagelok fitting near RC-704 on Reactor head

"* Supported replacement of welded Swagelok fitting on S/G level transmitter condensing pot due to damaged fitting

"* Supported plant startup which included venting of transmitters on primary and secondary side

"* Corrected the sensing line misalignment on steam flow transmitter

"* Replaced the circuit board in N-43 drawer due to sticking test pushbutton

"* Replaced a pressure gauge on service water pump

"* Repaired module mounting screw holes in Foxboro racks

"* Recalibrated the Foxboro module for temperature setpoint 2, TC405L

"* Replaced solenoid coil on "A" main feedwater regulating valve and "A" main feedwater bypass valve due to EQ Electrical Maintenance Performed preventative maintenance and surveillance procedures on the following equipment:

"* Buses 1 & 2 UV/UF Relays

"* SP42-320A & B Auto Sequencer Relays

"* Reactor Trip Breakers

"* Buses 5 & 6 UV Relays

"* Station Batteries

"* Substation Batteries

"* Substation Inspection Work Orders:

"* Inverter BRA-111 Repair

"* Inverters BRA-112, BRB-11 & 112 Frequency Adjustments

"* Demobilize SGR Facilities

"* Demobilize Ecolochem Trailers & Equipment Mechanical Maintenance

"* Installed insulation on the Pressurizer Surge Line and B Reactor Coolant Pump left during the outage

"* Installed a new actuator and valve on SW-301B, Emergency Diesel Generator B Service Water Return Isolation

"* Commenced trouble shooting 1B2 Traveling Water Screen

"* Performed PM's on the Charging Pump Dampeners

"* Replaced the mechanical seal on 1B Spent Fuel Pump

AVERAGE DAILY UNIT POWER DOCKET NO-50-305 UNIT-KEWAUNEE COMPLETED BY-M. L.

ANDERSON TELEPHONE-920-388-8453 LEVEL REPORT MONTH DAY 1

2 3

4 5

6 7

8 9

10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31

DECEMBER, 2001 AVERAGE DAILY POWER LEVEL (MWE-NET) 0 0

24 18 131 132 213 385 388 438 484 483 483 504 508 508 525 529 525 529 533 525 533 525 533 529 529 529 529 529 533

DOCKET NO:

UNIT NAME:

DATE:

COMP BY:

TELEPHONE:

50-305 Kewaunee January 10, 2002 Mary L. Anderson 920-388-8453 UNIT SHUTDOWNS AND POWER REDUCTIONS REPORT MONTH - DECEMBER 2001 METHOD SYSTEM & COMPONENT CODES F: FORCED S: SCHEDULED A-Equipment Failure (explain)

B-Maintenance or Test C-Refueling D-Regulatory Restriction E-Operator Training & License Examination F-Administrative G-Operational Error (explain)

H-Other (explain) 1-Manual 2-Manual Scram 3-Automatic Scram 4-Continuations 5-Load Reductions 9-Other From NUREG-0161 LER NO.

DATE TYPE DURATION REASON METHOD NO.

SYS COMPONENT COMMENTS Cycle XXIV-XXV Refueling Outage continued through 12/04. G-l was closed at 1935, full 4

12-01-01 S

80.2 C

4 N/A ZZ ZZZZZZ power was achieved on 12/19 at 1625. The unit continues to operate at 100% power, steady state operation.

1 4-1 4

1-1 1

I I

4-1 4

+

I I

I 1 _____

+/- ____

a ____

a ___________

TYPE REASON

OPERATING DATA REPORT DOCKET NO-50-305 COMPLETED BY-M. L. ANDERSON TELEPHONE-920-388-8453 OPERATING STATUS 1 UNIT NAME KEWAUNEE 2 REPORTING PERIOD

DECEMBER, 2001 3 LICENSED THERMAL POWER (MWT) 1650 4 NAMEPLATE RATING (GROSS MWE) 560 5 DESIGN ELECTRICAL RATING (NET MWE) 535 6 MAXIMUM DEPENDABLE CAPACITY (GROSS MWE) 537 7 MAXIMUM DEPENDABLE CAPACITY (NET MWE) 511 8 IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS NUMBER None 9 POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE) 10 REASONS FOR RESTRICTIONS, IF ANY THIS MONTH YR-TO-DATE CUMULATIVE 11 HOURS IN REPORTING PERIOD 12 NUMBER OF HOURS REACTOR WAS CRITICAL 13 REACTOR RESERVE SHUTDOWN HOURS 14 HOURS GENERATOR ON-LINE 15 UNIT RESERVE SHUTDOWN HOURS 16 GROSS THERMAL ENERGY GENERATED (MWH) 17 GROSS ELECTRICAL ENERGY GENERATED (MWH) 18 NET ELECTRICAL ENERGY GENERATED (MWH) 19 UNIT SERVICE FACTOR 20 UNIT AVAILABILITY FACTOR 21 UNIT CAPACITY FACTOR (USING MDC NET) 22 UNIT CAPACITY FACTOR (USING DER NET) 23 UNIT FORCED OUTAGE RATE 24 SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS N/A NOTES G-1 was closed on 12/04 @ 1935 Full power was reached on 12/19 @ 1625 Unit continues to operate at 100% power 3 THROUGH 7) SINCE LAST REPORT, GIVE REASONS 744 723.8 0.0 663.8 0.0 950489 319300 303281 89.2 89.2 79.8 76.2 0.0 8760 7080.7 0.0 7010.8 0.0 10974485 3641400 3461717 80.0 80.0 77.3 73.9 0.5 241466 204965.9 2330.5 202778.5 10.0 320664483 106328900 101173497 84.0 84.0 81.8 78.3 1.7 25 IF SHUT DOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP -

N/A