January 18, 2002 Mr. J. A. Scalice Chief Nuclear Officer and Executive Vice President Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, Tennessee 37402-2801

SUBJECT:

WATTS BAR NUCLEAR PLANT, UNIT 1 REACTOR VESSEL FRACTURE TOUGHNESS TESTING COMPLETION OF J-R CURVE TESTING FOR CAPSULE W SPECIMENS (TAC NO. MB2335)

Dear Mr. Scalice:

Watts Bar License Condition C.(5) Reactor Vessel Fracture Toughness Testing specifies, in part, that Supplemental fracture toughness testing (J-R) will be performed in accordance with a testing procedure that has been previously reviewed and approved by the NRC staff on Surveillance Capsule W specimens (removed from Cycle 3 Refueling Outage) and Capsule X specimens (to be removed from Cycle 5 Refueling Outage).

The U.S. Nuclear Regulatory Commissions (NRCs) letter of August 1, 2001, documented our verbal approval of your Capsule W specimen testing procedure and plan prior to you testing irradiated specimens on July 18, 2001. On October 9, 2001, you submitted the Surveillance Capsule W specimen test results to us.

With the successful completion of J-R curve testing for Capsule W specimens, I am closing TAC number MB2335. We will review and evaluate your Surveillance Capsule W specimen test results and assess your J-R curve data under a new TAC number. I will send you a letter documenting our review of your J-R curve data later. Please contact me if you have any questions.

Sincerely,

/RA/

L. Mark Padovan, Project Manager, Section 2 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-390 cc: See next page

January 18, 2002 Mr. J. A. Scalice Chief Nuclear Officer and Executive Vice President Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, Tennessee 37402-2801

SUBJECT:

WATTS BAR NUCLEAR PLANT, UNIT 1 REACTOR VESSEL FRACTURE TOUGHNESS TESTING COMPLETION OF J-R CURVE TESTING FOR CAPSULE W SPECIMENS (TAC NO. MB2335)

Dear Mr. Scalice:

Watts Bar License Condition C.(5) Reactor Vessel Fracture Toughness Testing specifies, in part, that Supplemental fracture toughness testing (J-R) will be performed in accordance with a testing procedure that has been previously reviewed and approved by the NRC staff on Surveillance Capsule W specimens (removed from Cycle 3 Refueling Outage) and Capsule X specimens (to be removed from Cycle 5 Refueling Outage).

The U.S. Nuclear Regulatory Commissions (NRCs) letter of August 1, 2001, documented our verbal approval of your Capsule W specimen testing procedure and plan prior to you testing irradiated specimens on July 18, 2001. On October 9, 2001, you submitted the Surveillance Capsule W specimen test results to us.

With the successful completion of J-R curve testing for Capsule W specimens, I am closing TAC number MB2335. We will review and evaluate your Surveillance Capsule W specimen test results and assess your J-R curve data under a new TAC number. I will send you a letter documenting our review of your J-R curve data later. Please contact me if you have any questions.

Sincerely,

/RA/

L. Mark Padovan, Project Manager, Section 2 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-390 cc: See next page DISTRIBUTION:

PUBLIC PDII-2 R/F RCorreia BClayton (Hard Copy)

MPadovan AHiser OGC ACRS PFredrickson, RII HBerkow ADAMS ACCESSION NO. ML020180165 OFFICE PDII-2/PM PDII-2/LA PDII-2/SC NAME MPadovan BClayton RCorreia DATE 1/17/02 1/17/02 1/18/02 OFFICIAL RECORD COPY

Mr. J. A. Scalice Tennessee Valley Authority WATTS BAR NUCLEAR PLANT cc:

Mr. Karl W. Singer, Senior Vice President Nuclear Operations Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. John R. Rupert, Vice President (Acting)

Engineering & Technical Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. William R. Lagergren, Site Vice President Watts Bar Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Spring City, TN 37381 General Counsel Tennessee Valley Authority ET 10H 400 West Summit Hill Drive Knoxville, TN 37902 Mr. Robert J. Adney, General Manager Nuclear Assurance Tennessee Valley Authority 5M Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. Mark J. Burzynski, Manager Nuclear Licensing Tennessee Valley Authority 4X Blue Ridge 1101 Market Street Chattanooga, TN 37402-2801 Mr. Paul L. Pace, Manager Licensing and Industry Affairs Watts Bar Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Spring City, TN 37381 Mr. Larry S. Bryant Manager Watts Bar Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Spring City, TN 37381 Senior Resident Inspector Watts Bar Nuclear Plant U.S. Nuclear Regulatory Commission 1260 Nuclear Plant Road Spring City, TN 37381 Rhea County Executive 375 Church Street Suite 215 Dayton, TN 37321 County Executive Meigs County Courthouse Decatur, TN 37322 Mr. Lawrence E. Nanney, Director Division of Radiological Health Dept. of Environment & Conservation Third Floor, L and C Annex 401 Church Street Nashville, TN 37243-1532 Ms. Ann Harris 305 Pickel Road Ten Mile, TN 37880