REACTOR COOLANT SYSTEM ISOLATED LOOP STARTUP LIMITING CONDITION FOR OPERATION 3.4.1.6 A reactor coolant loop shall remain isolated with power removed from the associated RCS loop stop valve operators until:
- a.
The temperature at the cold leg of the isolated loop is within 20°F of the highest cold leg temperature of the operating loops, and
- b.
The boron concentration of the isolated loop is greater than or equal to the boron concentration required by Specifications 3.1.1.1.2 or 3.1.1.2 for MODE 5 or Specification 3.9.1.1 for MODE 6.
APPLICABILITY:
MODES 5 and 6.
ACTION:
- a.
With the requirements of the above specification not satisfied, do not open the isolated loop stop valves.
SURVEILLANCE REQUIREMENTS 4.4.1.6.1 The isolated loop cold leg temperature shall be determined to be within 20°F of the highest cold leg temperature of the operating loops within 30 minutes prior to opening the cold leg stop valve.
4.4.1.6.2 The isolated loop boron concentration shall be determined to be greater than or equal to the boron concentration required by Specifications 3.1.1.1.2 or 3.1.1.2 for MODE 5 or Specification 3.9.1.1 for MODE 6 within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> prior to opening the hot or cold leg stop valve.